3rd Generation of Basic/Smart/Smart Plus/Intelligent Charger-32A User Manual Revision 1.11 User Manual Rev 1.11 Basic/Smart/Smart Plus/Intelligent Charger-32A 1 User Manual Rev 1.11 IMPORTANT SAFETY INSTRUCTIONS This document contains instructions and warnings that must be followed when installing and using the Electric Vehicle Supply Equipment (EVSE). Before installing or using the EVSE, read this entire document as well as WARNING and CAUTION markings in this document. Safety Instructions The symbols used have the following meaning:
WARNING: RISK OF PERSONAL INJURY WARNING: RISK OF ELECTRIC SHOCK WARNING: RISK OF FIRE CAUTION: RISK OF DAMAGE TO THE EQUIPMENT The charge point must be installed only by licensed electricians. Make sure that the materials used and the installation procedures follow local building codes and safety standards. The information provided in this manual in no way exempts the user of responsibility to follow all applicable codes or safety standards. This document provides instructions for the charge point and should not be used for any other product. Before installation or use of this product, review this manual carefully and consult with a licensed contractor, licensed electrician, or trained installation expert to make sure of compliance with local building codes and safety standards. Basic/Smart/Smart Plus/Intelligent Charger-32A 2 User Manual Rev 1.11 Repair and Maintenance Clause Only licensed electricians can repair or maintain the charge point. It is forbidden for general users to repair or maintain it. Turn off input power before repair or maintenance the charge point. Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
-
-
-
-
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with greater than 20cm between the radiator & your body. Basic/Smart/Smart Plus/Intelligent Charger-32A 3 User Manual Rev 1.11 Industry Canada statement:
This device complies with ISEDs license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d ISED applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) le dispositif ne doit pas produire de brouillage prjudiciable, et (2) ce dispositif doit accepter tout brouillage reu, y compris un brouillage susceptible de provoquer un fonctionnement indsirable. Radiation Exposure Statement:
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with greater than 20cm between the radiator & your body. Dclaration d'exposition aux radiations:
Cet quipement est conforme aux limites d'exposition aux rayonnements ISED tablies pour un environnement non contrl. Cet quipement doit tre install et utilis plus de 20 cm entre le radiateur et votre corps. WARNING: RISK OF ELECTRIC SHOCK Basic precautions should always be followed when using electrical products, including the following:
Read all the instructions before using this product. This device should be supervised when used around children. Do not put fingers into the EV connector. Do not uses this product if the flexible power cord or EV cable is frayed, has broken insulation, or any other signs of damage. Do not use this product if the enclosure or the EV connector is broken, cracked, open, or shows any other indication of damage. WARNING: RISK OF ELECTRIC SHOCK Improper connection of the equipment grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly ground-ed. Basic/Smart/Smart Plus/Intelligent Charger-32A 4 User Manual Rev 1.11 WARNING: RISK OF ELECTRIC SHOCK Do not touch live electrical parts. Incorrect connections may cause electric shock. WARNING: This equipment is intended only for charging vehicles that do not require ventilation during charging. Please refer to your vehicles owners manual to determine ventilation requirements. WARNING: Do not use extender cables to increase the length of the charging cable. Maximum length is limited to 25 feet by the National Fire Protection Agency. WARNING: Do not drag the charge point by input power cord. SAVE THESE INSTRUCTIONS Basic/Smart/Smart Plus/Intelligent Charger-32A 5 Contents User Manual Rev 1.11 1 Introduction .......................................................................................................................................... 9 Product view ............................................................................................................................... 9 2 Specifications ...................................................................................................................................... 15 Product specifications ............................................................................................................... 15 3 Installation .......................................................................................................................................... 17 Before installation ..................................................................................................................... 17 3.1.1 Safety check ................................................................................................................. 17 3.1.2 Grounding instructions ................................................................................................ 17 Tools & parts required for installation ...................................................................................... 18 Install the SIM card (for IC3 only) ............................................................................................. 18 Install the charge point ............................................................................................................. 23 Input cord connection (for SC3+/IC3 only) ............................................................................... 26 Install the holster ...................................................................................................................... 29 Getting started (for SC3/SC3+/IC3 only) ................................................................................... 32 3.7.1 Setting up the local network ........................................................................................ 32 3.7.2 Log in ............................................................................................................................ 34 Web-page overview (for SC3/SC3+/IC3 only) ........................................................................... 35 3.8.1 Menu overview ............................................................................................................ 35 3.8.2 Configuration menu ..................................................................................................... 36 3.8.3 Maintenance menu ...................................................................................................... 37 3.8.4 EVSE Status ................................................................................................................... 38 3.8.5 LLM Status menu [support only on SC3+/IC3] ............................................................. 39 3.8.6 Security menu .............................................................................................................. 40 Configuration ............................................................................................................................ 41 Basic/Smart/Smart Plus/Intelligent Charger-32A 6 User Manual Rev 1.11 3.9.1 Factory settings ............................................................................................................ 41 3.9.2 Station settings............................................................................................................. 42 3.9.3 OCPP settings ............................................................................................................... 44 3.9.4 Communication settings .............................................................................................. 51 Maintenance ............................................................................................................................. 59 3.10.1 Reboot .......................................................................................................................... 59 3.10.2 Firmware upgrade ........................................................................................................ 62 EVSE Status ............................................................................................................................... 63 LLM Status (SC3+/IC3 support only) ......................................................................................... 64 3.12.1 LLM information ........................................................................................................... 64 3.12.2 Gateway/Client group table ......................................................................................... 65 Security ..................................................................................................................................... 66 3.13.1 Change password ......................................................................................................... 66 4 Operations .......................................................................................................................................... 67 Charging status indicators ......................................................................................................... 67 Authorization (for SC3+/IC3 only) ............................................................................................. 68 4.2.1 Online Authorization .................................................................................................... 68 4.2.2 Local Authorization ...................................................................................................... 68 Charging an Electric Vehicle (EV) .............................................................................................. 69 4.3.1 Plug and Charge ........................................................................................................... 69 4.3.2 RFID card (for SC3+/IC3 only) ....................................................................................... 70 Stop charging ............................................................................................................................ 70 4.4.1 Interrupt charging ........................................................................................................ 70 4.4.2 Auto restart .................................................................................................................. 70 4.4.3 Power outage recovery ................................................................................................ 70 General care .............................................................................................................................. 71 Basic/Smart/Smart Plus/Intelligent Charger-32A 7 User Manual Rev 1.11 Customer support ..................................................................................................................... 71 Basic/Smart/Smart Plus/Intelligent Charger-32A 8 User Manual Rev 1.11 1 Introduction This user manual applies to 32A Level 2 AC Charger for Plug-in Electric Vehicles (PEVs) and Battery Electric Vehicles (BEVs). The Level 2 Electric Vehicle Supply Equipment (EVSE) with 32A capabilities will be used in North America. It can provide a shorter charging time than the traditional 16A EVSE.
!!! Any unauthorized modifications will void the manufacturers warranty. !!!
Product view Different models of 3rd Generation of Charger:
Basic Charger-32A (BC3) Smart Charger-32A (SC3) Intelligent Charger-32A (IC3) Smart Charger Plus-32A (SC3+) Figure 1-1 Front view Basic/Smart/Smart Plus/Intelligent Charger-32A 9 Box Contents User Manual Rev 1.11 See the table for content differences of three models. Figure 1-2 Box contents Table 1-1 Accessories in the box Description QTY Remark 1 Basic Charger-32A (BC3) Smart Charger-32A (SC3) Smart Charger Plus-32A (SC3+) Intelligent Charger-32A (IC3) 2 Mounting Bracket 3 4 Holster ASSY Screw Bag Charging Plug OLED Display Charging Plug OLED Display Charging Plug OLED Display Input Power Cord RFID Icon Input Power Cord RFID Icon Input Power Cord RFID Icon Attached to the back of the charge point With Hook x1, Holster x1 & M4xL15 tapping screw x2 With #12xL50 tapping screw x4 1 1 1 1 Basic/Smart/Smart Plus/Intelligent Charger-32A 10 User Manual Rev 1.11 Box Opening Process (Take Intelligent Charger-32A as example.) 1. Open the carton and remove the upper partition. Figure 1-3 Opening the carton Figure 1-4 Charge point device Basic/Smart/Smart Plus/Intelligent Charger-32A 11 User Manual Rev 1.11 2. Take out the charge point and upturn middle partition. The charging plug is in the bottom of the carton. Figure 1-5 Take out the charge point Figure 1-6 Charging plug Basic/Smart/Smart Plus/Intelligent Charger-32A 12 User Manual Rev 1.11 3. The hook and holster is placed inside the right of the middle partition. Figure 1-7 Accessories inside the middle partition Figure 1-8 Hook and holster Basic/Smart/Smart Plus/Intelligent Charger-32A 13 User Manual Rev 1.11 4. Release the bottom screw, then the wall mounting bracket can be removed. Figure 1-9 Release the screw Figure 1-10 Remove the mounting bracket Basic/Smart/Smart Plus/Intelligent Charger-32A 14 User Manual Rev 1.11 2 Specifications Product specifications
(Note: Certification in process) Item Application Voltage (Vac) Frequency (Hz) Current (Rms) Charging Connector Charging Cable Length Metering Accuracy Real Time Clock Indications Wi-Fi Cellular RFID Display Data Protocol Operation Temp. Storage Temp. Mounting Type Wiring Type IP Performance Impact Resistance Dimension (H x W x D, inch) Table 2-1 Product specifications BC3 SC3 SC3+
IC3 Residential Commercial 208/240VAC, Single Phase 60 Hz 32 A SAE J1772 Type 1 25 ft. (18 ft. optional) Embedded 3%
Yes (7 days) N/A N/A Green Steady: Ready Green Flashing (Fast): Authorized, wait for EV Connect Green Flashing (Slow): Suspend (Occupying) Blue Flashing (Slow): Charging Red Steady: Unrecoverable Fault Red Flashing (Slow): Recoverable Fault Yellow Steady: Out of Service Yellow Flashing (Slow): Booting / Firmware Upgrading Remark Fast Flash: On Time 300ms, Off Time 200ms, 2Hz Slow Flash: On Time 1200ms, Off Time 800ms, 0.5Hz 802.11 b/g/n N/A N/A N/A LTE Cat. 1
(AT&T or Verizon) ISO 14443 A/B, ISO 15693, NFC, N/A 116(L)*8.5(W)*37(H)mm, 5.57mm CHARAXTER HEIGHT, 5*8 NEMA interoperability protocol N/A DOT MATRIX, OLED 20x2 OCPP 1.6
-30 ~ 50 / -22 ~ 122
-40 ~ 70 / -40 ~ 158 Wall mount / Pole mount (optional) NEMA 6-50 Hard-wired NEMA 4 IK10 11.14 x 7.56 x 3.11 Basic/Smart/Smart Plus/Intelligent Charger-32A 15 User Manual Rev 1.11 Item Web Portal Management Console Management Certification BC3 N/A N/A SC3 SC3+
Yes Yes UL 50/991/1449/1998/2231/2594 IC3 FCC Part 15B FCC Part 15.225 (RFID 13.56MHz) FCC Part 15.247 (WLAN 2.4GHz) N/A FCC Part 27
(AT&T) or FCC Part 27
(Verizon) Basic/Smart/Smart Plus/Intelligent Charger-32A 16 User Manual Rev 1.11 3 Installation Before installation 3.1.1 Safety check CAUTION: Disconnect the power supply before installing or repairing the charge point. Failure to do so may result in physical injury or damage to the power supply system and the charge point. The charge point must be installed only by a licensed electrician in accordance with the provisions of the local electrical industry construction and should comply with national electrical codes and standards. Before installing the charge point, make sure you have read all of these instructions in this manual and fully understand its contents. Appropriate protection is required when connecting to a main switchboard. The tools and parts used as outlined in the section Tools & parts required for installation. 3.1.2 Grounding instructions The charge point must be implemented equipment grounding through a permanent wiring system or an equipment grounding conductor. Use a wire with a dedicated grounding wire and a ring terminal and connected to the equipment ground terminal block for grounding. Basic/Smart/Smart Plus/Intelligent Charger-32A 17 User Manual Rev 1.11 Tools & parts required for installation Table 3-1 Tools & parts required for installation Tool QTY Model Size Supplier Remark Mounting Bracket Holster ASSY Screw Wire, Copper Heat Shrink Tube Terminal Conduit Torx Screwdriver Philips Screwdriver Hexagon Socket Torque Wrench 1 1 4 3 3 3 1 1 1 1 1 All All All SC3+
/IC3 SC3+
/IC3 SC3+
/IC3 SC3+
/IC3 All All All All 194x109x9 mm Model Accessories 58x58x70 mm Tapping: #12 Mechanical: M6 Commercially Available Model Accessories Model Accessories Fasten charge point to the wall Hold EV charging plug Fasten Mounting Bracket &
Hook 8 AWG Commercially Available UL1015 (recommended) For 8 AWG wire Commercially Available Protect wires & terminals For 8 AWG wire Commercially Available Connect input wires to the terminal block 1 inch Commercially Available Protect power cable T20 PH3 5/16 35 kgf-cm min Commercially Available Commercially Available Commercially Available Commercially Available Tighten #12 Tapping screws Install the SIM card (for IC3 only) 1. Disassemble top cover 1-1 Loosen the star screws (x5). Basic/Smart/Smart Plus/Intelligent Charger-32A 18 User Manual Rev 1.11 Figure 3-1 Five screws in the Base Cover position 2. Find SIM card socket Figure 3-2 Position of SIM card socket Basic/Smart/Smart Plus/Intelligent Charger-32A 19 3. Insert SIM card User Manual Rev 1.11 Figure 3-3 SIM card socket and cover Open/Close direction 3-1. Push down the cover to open SIM card socket. Figure 3-4 Open SIM card socket 3-2. Prepare the SIM card. (Use micro-SIM, 15mm x 12mm.) Basic/Smart/Smart Plus/Intelligent Charger-32A 20 User Manual Rev 1.11 Figure 3-5 Prepare the SIM card
. Basic/Smart/Smart Plus/Intelligent Charger-32A 21 User Manual Rev 1.11 3-3. Insert the SIM card. Figure 3-6 Insert the SIM card 3-4. Close the SIM card socket and push the cover toward lock direction to lock the cover. Figure 3-7 Lock SIM card socket cover 3-5. Reassemble the top cover. Please refer to the following torque. SIM card installation is completed. Screw M4 Torque 16 kgf.cm 13.88 lb-in Basic/Smart/Smart Plus/Intelligent Charger-32A 22 User Manual Rev 1.11 Install the charge point 1. Secure the main body mounting bracket to the wall with appropriate screw. Follow applicable accessibility requirements for the mounting position. The unit shall be stored or located at a sufficient height. For indoor site, it is not lower than 18 (450 mm) and not higher than 4 (1.2m). For outdoor site, it is not lower than 24 (600 mm) and not higher than 4 (1.2m). Refer to Article 625, NEC. The mounting bracket has ten screw holes. If only two screws be used to fasten the mounting bracket, the screws should pass through the middle two screw holes of the mounting bracket. The other screw holes are reserved for the user. Figure 3-8 Fixing mounting bracket Figure 3-9 Screw holes of mounting bracket Screw suggestion:
a. For masonry walls, use M6 mechanical screws. (Commercially available) b. For finished walls supported by wood studs, use 1/4or M6 tapping screws. (Commercially available) c. Please use following torque force. Screw M6
#12 Torque 25 kgf.cm min 25 kgf.cm min 21.7 lb-in min 21.7 lb-in min Basic/Smart/Smart Plus/Intelligent Charger-32A 23 User Manual Rev 1.11 2. Mount charge point onto mounting bracket and lock the screw. 2-1. Put the charge point on the mounting bracket. 2-2. Fix charge point on mounting bracket by M4 screw and screw washer. 2-3. Please refer to the following torque. Screw M4 Torque 16 kgf.cm 13.88 lb-in Figure 3-10 Charge point and mounting bracket Figure 3-11 Screw locking position Basic/Smart/Smart Plus/Intelligent Charger-32A 24 User Manual Rev 1.11 3. Plug in the power cord. (BC3/SC3 ONLY) The outlet should be located at 20-26 inch from the ground. Refer to the installation template to decide where to install the charge point. Figure 3-12 Plug in the power cord Basic/Smart/Smart Plus/Intelligent Charger-32A 25 User Manual Rev 1.11 Input cord connection (for SC3+/IC3 only) 1. Choose the appropriate conduit in accordance with all applicable state, local and national electrical codes and standards. Figure 3-13 Conduit. Figure 3-14 Right angle conduit 2. Clamp copper terminal to connect copper wire. The clamp point is covered by heat shrink tube for protecting. 2-1 Refer to the following wire specification. Use conductor type other than RHH, RHW and RHW-2 with outer covering. Model Terminal Conductor Rating Smart Charger Plus-32A Intelligent Charger-32A L1, L2,G 8 AWG 90C copper wire Figure 3-15 Copper terminal, heat shrink tube and copper wire. Basic/Smart/Smart Plus/Intelligent Charger-32A 26 User Manual Rev 1.11 3. Electrical wiring to the charge point. 3-1. Disassemble top cover. 3-2. Use Philips screwdriver to release terminal screws. 3-3. Fold the wire end to pass through the conduit and insert them into the input hole. 3-4. Fix the copper wire on the corresponding terminal block. The wiring instruction is printed in front of the terminal block (L1/L2/G). 3-5. Use the following torque to connect the wire terminal to the terminal block. Screw M4 Torque 16 kgf.cm 13.88 lb-in Figure 3-16 Input wiring CAUTION: To reduce the risk of fire, connect only to a circuit provided with 40 amperes maximum branch circuit overcurrent protection in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code, Part I, C22.1. Basic/Smart/Smart Plus/Intelligent Charger-32A 27 User Manual Rev 1.11 Model Current Rating Smart Charger Plus-32A Intelligent Charger-32A 32 A 3-6. Lock the conduit on the enclosure. Please refer to the following torque. 3-7. Reassemble top cover. Please refer to the following torque. Conduit 1 Torque 35 kgf.cm 30.36 lb-in Screw M4 Torque 16 kgf.cm 13.88 lb-in Basic/Smart/Smart Plus/Intelligent Charger-32A 28 User Manual Rev 1.11 Install the holster 1. Separate the holster from hook. Figure 3-17 Separate the holster 2. Fasten the hook on the wall with appropriate screws. 2-1. For finished walls supported by wood studs, use #12 tapping screws (x2). 2-2. The recommend torque is 25 kgf.cm (21.7 lb-in). Figure 3-18 Secure the hook Basic/Smart/Smart Plus/Intelligent Charger-32A 29 User Manual Rev 1.11 3. Make the holster face up and combine with the hook. Figure 3-19 Secure the holster 4. Rotate the holster down totally. Figure 3-20 Rotate the holster Basic/Smart/Smart Plus/Intelligent Charger-32A 30 User Manual Rev 1.11 5. Keep the holster in this state and tighten screws completely. Figure 3-21 Lock screws 6. Place EV charging plug on the holster. Figure 3-22 Place EV charging plug. Basic/Smart/Smart Plus/Intelligent Charger-32A 31 User Manual Rev 1.11 Getting started (for SC3/SC3+/IC3 only) 3.7.1 Setting up the local network Firstly, connect a computer to the charge point using an Ethernet cable. Figure 3-23 Location of Ethernet RJ-45 port Basic/Smart/Smart Plus/Intelligent Charger-32A 32 User Manual Rev 1.11 Secondly, set up a dynamic IP Address on your computer. For windows system, choose Obtain an IP address automatically in Internet Protocol Version 4 (TCP/IPv4) Properties dialog like the following figure. Basic/Smart/Smart Plus/Intelligent Charger-32A 33 3.7.2 Log in User Manual Rev 1.11 Open a web browser (Internet Explorer for example) and enter the IP address of SC3/SC3+/IC3. Please enter the text below in the address field of the browser and press enter. http://192.168.199.1 If Netwrok Mode is Gateway and Group Use External Gateway is No. or http://192.168.100.1 Any other Netwrok Mode. Now you should see the login screen:
To be able to configure the charge point you should enter admin in the user name box. The default password is howru2RU2IC3. Basic/Smart/Smart Plus/Intelligent Charger-32A 34 User Manual Rev 1.11 Web-page overview (for SC3/SC3+/IC3 only) 3.8.1 Menu overview To navigate via the web browser, use the menu items available: Configuration, Maintenance, EVSE Status, LLM Status, and Security. Logout button Menu List Basic/Smart/Smart Plus/Intelligent Charger-32A 35 User Manual Rev 1.11 3.8.2 Configuration menu When you choose the Configuration menu, a sub menu will appear:
The Factory Settings tab is used to display the information of the charge point. The Station Settings tab is used to set up the configuration regarding to the charge point itself. The OCPP Settings tab is used to set up the custom properties for uses in OCPP 1.6 services. The Communication Settings tab is used to set up the network connection and load management. Basic/Smart/Smart Plus/Intelligent Charger-32A 36 User Manual Rev 1.11 3.8.3 Maintenance menu When you choose the Maintenance menu, a sub menu will appear:
The Command screen can be used to restart the charge point and reset settings to Manufacturing default. The Charging Profile Data screen can be used to show and clear charging profiles including Charge Point Max Profile, Tx Default Profile and Tx Profile. Charging Profile is defined in OCPP 1.6 specification. The Local Authorization screen can be used to display and clear the Local Authorization List and Authorization Cache List. Both lists are defined in OCPP 1.6 specification. The Firmware Upgrade screen can be used to upgrade the firmware of the charge point. Basic/Smart/Smart Plus/Intelligent Charger-32A 37 3.8.4 EVSE Status User Manual Rev 1.11 When you choose the EVSE Status menu, a sub menu will appear:
The Electric Vehicle Supply Equipment Status can be used to show the information of EVSE. Usually these information are only for diagnostic use. Basic/Smart/Smart Plus/Intelligent Charger-32A 38 User Manual Rev 1.11 3.8.5 LLM Status menu [support only on SC3+/IC3]
When you choose the LLM Status menu, a sub menu will appear:
The Local Load Management Status screen shows the Local Load Management (LLM) settings and current Master/Slave group member list. Basic/Smart/Smart Plus/Intelligent Charger-32A 39 User Manual Rev 1.11 3.8.6 Security menu When you choose the Security menu, a sub menu will appear:
The Change Password screen can be used to change the password of users for this web portal. Basic/Smart/Smart Plus/Intelligent Charger-32A 40 Configuration 3.9.1 Factory settings User Manual Rev 1.11 Clicking on the Configuration and then Factory Settings link will bring up the following screen:
Basic Information Charge Point Vendor The vendors name of the charge point. Charge Point Model The models name of the charge point. Charge Point Serial Number The unique serial number of the charge point. Hardware Version The hardware version of the charge point. Firmware Version The software version of the charge point. Meter Type The meter type of the charge point. Reader Type The reader type of the charge point. [Support only on SC3+/IC3]
DSMR Type The DSMR type of the charge point. Production Date The production date of the charge point. Basic/Smart/Smart Plus/Intelligent Charger-32A 41 Charging Connector Information User Manual Rev 1.11 Number Of Connectors Number of connectors of the charge point. Connector Type* Indicates type 1 or type 2 cable installed in the charge point. Max Amperage Connector The maximum charging current of the connector capability.
* A charge point may have multiple connectors installed. For our product, there is only one connector on them. 3.9.2 Station settings Clicking on the Configuration and then Station Settings link will bring up the following screen. Since the page is too long to display, we separate it to 2 screens. On this page you can change the properties of the charge point. Click the Apply button at the right side of the property when the value is changed. Warning Settings Temperature Low Value in Celsius at which the charge point will send a temperature low warning message. Temperature High Value in Celsius at which the charge point will send a temperature high warning message. Basic/Smart/Smart Plus/Intelligent Charger-32A 42 User Manual Rev 1.11 Voltage Low Value at which the charge point will send an under voltage warning message. Voltage High Value at which the charge point will send an over voltage warning message. General Settings Output Power Type AC or DC output power. In our product, this value is always AC. Power Phase Connected Input power phase connected to the charge point to indicate single phase or three phases. This value is always 1. Max Amperage HW Setting The DIP switches (Hardware) settings to indicate the maximum charging current. Max Amperage FW Setting The software settings to indicate the maximum charging current. PWM Amperage The PWM setting for charging current when the charge point is online. This signal is to tell EV how much current is allowed to use. Real Amperage The real-time charging current detected by the charge point. Cold Load Pickup Max Delay Default cold load pickup delay is 120s ~ 720s. The max value could be changeable by this property. Basic/Smart/Smart Plus/Intelligent Charger-32A 43 User Manual Rev 1.11 Plug and Charge ID If the value is present, the charge point needs to support plug and charge scenario by using the specific identifier. If absent, authorization for each session is required. This ID must be 8 or more characters. Reservation Supported If true, the charge point will support reservation related messages from Central System. Resume Charge After Reboot Indicate if the charge point resumes charging after power recycle. If true, the charge point will resume charging according to UL regulations. If false, the charge point will not resume charging. RFID Reader Indicate if RFID reader is available. [Support only on SC3+/IC3]
Ventilation Required Indicate if ventilation equipment is required. If set this option to yes, a ventilation fault will occur when the EV report for need ventilation equipment. Recommend setup value are shown below according to the place and ventilation equipment available or not. Place Ventilation Equipment Available Ventilation Equipment Not Available Indoor Outdoor No No Yes No Skip Heartbeat Message Indicate if Heartbeat message is skipped if any other message is sent successfully during a heartbeat interval. Other Information Last Boot Time Show last boot time. 3.9.3 OCPP settings Basic/Smart/Smart Plus/Intelligent Charger-32A 44 User Manual Rev 1.11 Clicking on the Configuration and then OCPP Settings link will bring up the following screen, since the page is too long to display, please using scrollbar to check remaining pages. On this page you can change the properties just for the charge point. Click the Apply button at the right side of the property when the value is changed. Remote Control Settings Remote Control Type: The remote control mode accept by SC3+/IC3. Options are APP: SC3+/IC3 can be remote controlled by mobile APP. OCPP: SC3+/IC3 can be remote controlled by OCPP 1.6 protocol. APP+OCPP: Both APP and OCPP are accepted by SC3+/IC3. Service Settings Basic/Smart/Smart Plus/Intelligent Charger-32A 45 User Manual Rev 1.11 Charge Point ID The identity of the charge point as known in the OCPP Central System. Protocol Name The name and version of OCPP is running in the charge point. Central System URL The URL of the OCPP v1.6 Central System service. Basic Auth ID The ID for BASIC authentication in HTTPS (SSL/TLS) connections. Basic Auth Password The password for BASIC authentication in HTTPS (SSL/TLS) connections. FTP Server Username The username of the FTP Server for OCPP to download firmware files and upload diagnostic file. FTP Server Password The password of the FTP Server for OCPP to download firmware files and upload diagnostic file. Message Transport Layer Select the transport layer of the OCPP service that will be used. For Intelligent Charger-32A, the available option is WS and WSS. WS: Connection from charge point to OCPP Server uses WebSocket protocol. WSS: Connection from charge point to OCPP Server uses Secure WebSocket protocol. Boot Notification Interval Interval of re-sending BootNotification.req if not accepted by Central System. Boot Notification Retries Number of times to retry sending BootNotification.req.
-1 means unlimited 0 means dont retry. PDU Timeout Interval until the charge point stop waiting for a PDU response. Download Firmware Interval Interval of downloading firmware from Central System. Download Firmware Retries Number of times to retry downloading firmware. Upload Diagnostics Interval Interval of uploading diagnostic file to Central System. Upload Diagnostics Retries Number of times to retry uploading diagnostic file. Basic/Smart/Smart Plus/Intelligent Charger-32A 46 User Manual Rev 1.11 OCPP1.6 Settings These settings are defined and request for support in OCPP 1.6 sepcification. AllowOfflineTxForUnknownId If set to yes, an unknown ID (not in Authorization and Cache List) will be accepted and start the charging session when charge point is not connected to central system. AuthorizationCacheEnabled Charge point supports an Authorization Cache or not. AuthorizeRemoteTxRequests Whether a remote request to start a transaction in the form of a RemoteStartTransaction.req message should be authorized beforehand like a local action to start a transaction. BlinkRepeat Number of times to blink the charge point lighting when signaling. This value is not changeable for our product. ClockAlignedDataInterval Size (in seconds) of the clock-aligned data interval. This is the size (in seconds) of the set of evenly spaced aggregation intervals per day, starting at 00:00:00 (midnight). ConnectionTimeOut Interval until incipient charging session is automatically canceled due to failure of EV user to insert the charging cable connector(s) into the appropriate connector(s). GetConfigurationMaxKeys Maximum number of requested configuration keys in a GetConfiguration.req PDU. Basic/Smart/Smart Plus/Intelligent Charger-32A 47 User Manual Rev 1.11 HeartBeatInterval Defines the heartbeat interval. LightIntensity Percentage of maximum intensity at which to illuminate the charge point lighting. This value is not changeable for our product. LocalAuthorizeOffline Whether the charge point, when offline, will start a transaction for locally-
authorizedidentifiers. LocalPreAuthorize Whether the charge point, when online, will start a transaction for locally authorized identifiers without waiting for or requesting an Authorize.conf from Central System. MaxEnergyOnInvalidId Maximum energy in Watt-hour (Wh) delivered when an identifier is invalidated by Central System after start of a transaction. MeterValuesAlignedData Clock-aligned measurand(s) to be included in a MeterValues.req PDU, every ClockAlignedDataInterval seconds. Supported value are Current.Import, Energy.Active.Import.Register, and Temperature, Voltage or any combination of these 4 value. MeterValuesAlignedDataMaxLength Maximum number of items in a MeterValuesAlignedData configuration key. MeterValuesSampledData Sampled measurands to be included in a MeterValues.req PDU, every MeterValueSampleInterval seconds. Supported value are Current.Import, Energy.Active.Import.Register, and Temperature, Voltage or any combination of these 4 value. MeterValuesSampledDataMaxLength Maximum number of items in a MeterValuesSampledData configuration key. MeterValueSampleInterval Interval between sampling of metering (or other) data, intended to be transmitted by "MeterValues" PDUs MinimumStatusDuration The minimum duration that a charge point or connector status is stable before a StatusNotification.req PDU is sent to Central System. NumberOfConnectors The number of physical charging connectors of this charge point. ResetRetries Number of times to retry an unsuccessful reset of the charge point. ConnectorPhaseRotation The phase rotation per connector in respect to the connectors energy meter. This is not supported by our product since it is single phase power input and the value will always be NotApplicable. Basic/Smart/Smart Plus/Intelligent Charger-32A 48 User Manual Rev 1.11 ConnectorPhaseRotationMaxLength Maximum number of items in a ConnectorPhaseRotation configuration key. StopTransactionOnEVSideDisconnect When set to true, the charge point SHALL administratively stop the transaction when the cable is unplugged from the EV. StopTransactionOnInvalidId Whether the charge point will stop an ongoing transaction when it receives a non-accepted authorization status in a StartTransaction.conf for this transaction. StopTxnAlignedData Clock-aligned periodic measurand(s) to be included in the TransactionData element of StopTransaction.req MeterValues.req PDU for every ClockAlignedDataInterval of the charging session. Supported value are Current.Import, Energy.Active.Import.Register, and Temperature, Voltage or any combination of these 4 value. StopTxnAlignedDataMaxLength Maximum number of items in a StopTxnAlignedData configuration key. Basic/Smart/Smart Plus/Intelligent Charger-32A 49 User Manual Rev 1.11 StopTxnSampledData Sampled measurands to be included in the TransactionData element of StopTransaction.req PDU, every MeterValueSampleInterval seconds from the start of the charging session. Supported value are Current.Import, Energy.Active.Import.Register, and Temperature, Voltage or any combination of these 4 value. StopTxnSampledDataMaxLength Maximum number of items in a StopTxnSampledData configuration key. SupportedFeatureProfiles A list of supported Feature Profiles. Possible profile identifiers: Core, FirmwareManagement, LocalAuthListManagement, Reservation, SmartCharging and RemoteTrigger. SupportedFeatureProfilesMaxLength Maximum number of items in a SupportedFeatureProfiles configuration key. TransactionMessageAttempts How often the charge point should try to submit a transaction-related message when Central System fails to process it. TransactionMessageRetryInterval How long the charge point should wait before resubmitting a transaction-related message that Central System failed to process. UnlockConnectorOnEVSideDisconnect When set to true, the charge point SHALL unlock the cable on charge point side when the cable is unplugged at the EV. This is not supported by our product since it is plug type and no connector locker. WebSocket Ping Interval Define the ping pong interval for WebSocket protocol. LocalAuthListEnabled Whether the Local Authorization List is enabled. LocalAuthListMaxLength Maximum number of identifications that can be stored in the Local Authorization List. SendLocalListMaxLength Maximum number of identifications that can be send in a single SendLocalList.req. ReserveConnectorZeroSupported If this configuration key is present and set to true: The charge point support reservations on connector 0. ChargeProfileMaxStackLevel Max Stack Level of a Charging Profile. The number defined also indicates the max allowed number of installed charging schedules per Charging Profile purposes. ChargingScheduleAllowedChargingRateUnit A list of supported quantities for use in a Charging Schedule. This value will always be 'Current' for our product. Basic/Smart/Smart Plus/Intelligent Charger-32A 50 User Manual Rev 1.11 ChargingScheduleMaxPeriods Maximum number of periods that may be defined per Charging Schedule. ConnectorSwitch3to1PhaseSupported If defined and true, this charge point supports switching from 3 to 1 phase during a charging session. This is not supported by our product since it is single phase power input MaxChargingProfilesInstalled Maximum number of charging profiles installed at a time. 3.9.4 Communication settings Clicking on the Configuration and then Communication Settings link will bring up the following screen. Since the page is too long to display, we separate it to couple screens. On this page you can set up the network connection. To finish, click the Apply button. Network Mode Specifies if enable the Local Proxy function. Available options are Gateway, Client and Direct. Direct: Use charge point as a single device. Basic/Smart/Smart Plus/Intelligent Charger-32A 51 User Manual Rev 1.11 Gateway: Use charge point as a gateway charge point. Gateway connected to OCPP 1.6 Server via cellular or Wi-Fi and connected to other charge points (called Client) via Wi-Fi and forms a local charge points group. This group is also a LAN (Local Area Network). Client: Use charge point as a client charge point. Client connected to Gateway via Wi-Fi. Client connected to OCPP1.6 Server through gateway charge point (via cellular or Wi-Fi) and Gateway will dispatch incoming remote command to proper client charge points (or Gateway itself). NOTE Network mode are used to change how a group SC3/SC3+/IC3 connecting to the internet. If a charge points network mode is Client, then there must be a Gateway in this group and all client charge points are connected to the internet via Gateway. These chargers form a Gateway/Client group. In this group there is exact one Gateway and all other charge points are Client. Basic/Smart/Smart Plus/Intelligent Charger-32A 52 User Manual Rev 1.11 Gateway LAN IP The IP of master in LAN. This value cannot be modified by users. Gateway LAN Port (SOAP) The listen port for OCPP SOAP client server. This value cannot be modified by users. Max Group Size The maximum number of charge points allowed in a group/LAN. This value cannot be modified by users. Gateway Serial Number The serial number of the charge point which acts as a Gateway. Group Use External Gateway Gateway/Client mode use external gateway as a local network group or not (use Gateway IC3). NOTE A Gateway charge point can choose using Wi-Fi or Cellular to connect to the internet by change
'Group Use External Gateway' setting. If set to Yes, a Gateway will use Cellular, or it will use Wi-Fi. When changed this setting, the 'Connectivity' option will automatically change as well. All charge point in this Gateway/Client group must have the same 'Group Use External Gateway'
setting, i.e. all charge points must set this option to Yes (including Gateway and Client) when we want to use an external Wi-Fi AP to connect to internet. In this case, all charge points must also use the same Wi-Fi settings (SSID, password) for the external Wi-Fi AP. Hide AP SSID Options for hiding SSID of this charge point or not. For our product this option is always off. Connectivity Specifies whether the charge point should always be connected to Internet using None, Auto, Wi-Fi, or Cellular. Default value is Auto. [Cellular: IC3 support only] When Network Mode is Direct, all option are available. If it is not, then Connectivity will be set with the following rule:
Network Mode Group Use External Gateway = Yes Group Use External Gateway = No Gateway Client Wi-Fi Wi-Fi Cellular Wi-Fi Wi-Fi setting will be disabled and Client will setup Wi-Fi to connect to Basic/Smart/Smart Plus/Intelligent Charger-32A 53 User Manual Rev 1.11 Gateway indicated by 'Gateway Serial Number'
Active Device Status Active Device Current active network device. Possible value are None, Wi-Fi or Cellular Active IP Address Current active IP address. There will be value here only if connected to a network. Active Netmask Current active netmask address. There will be value here only if connected to a network. Active Gateway Current active gateway IP address. There will be value here only if connected to a network and network provide this data. Active Primary DNS Current active primary DNS IP address. There will be value here only if connected to a network and network provide this data. Active Secondary DNS Current active secondary DNS IP address. There will be value here only if connected to a network and network provide this data. Wi-Fi Settings SSID The SSID name of Wi-Fi Access Point. Press Scan button to scan and receive current detectable Wi-Fi signal. Security The encryption of Wi-Fi Access Point. Options are None, WEP, WPA-PSK, WPA2-PSK, WPA-
PSK+WPA2-PSK and Auto. Password The password of Wi-Fi Access Point. BSSID The MAC Address of Wi-Fi Access Point. If your Access Point is hidden SSID, please enter this address. Basic/Smart/Smart Plus/Intelligent Charger-32A 54 User Manual Rev 1.11 Wi-Fi MAC Address Display Wi-Fi device hardware MAC address. Wi-Fi Signal Strength Display the wireless signal strength of Wi-Fi in percentage (%). Station Only If "Station Only" is ON, the charger will stay in station mode always. If "Station Only" is OFF, it will go into AP mode after 5 times retrying to connect the external Wi-Fi AP. Note:
The Station Only option only work if remote control type is OCPP. If the remote control type is APP it keeps original behavior (retry 5 times and go to AP mode) no matter what Station Only option selected. Cellular Settings [Support only on IC3]
MNC The Mobile Network Code of cellular service provider. There will be no data here if no 3G/LTE signal. ICCID The ICCID of the modems SIM card. There will be no data here if no SIM card inserted. IMSI The IMSI of the modems SIM card. There will be no data here if no SIM card inserted. IMEI The IMEI (International Mobile Equipment Identity) of the modem. MEID The MEID (Mobile Equipment Identifier) of the modem. Basic/Smart/Smart Plus/Intelligent Charger-32A 55 User Manual Rev 1.11 Cellular APN This is the gateway for all cellular traffic. Contact your cellular operator for information about this. For AT&T and Verizon LTE service, just leave it blank since the apn name is built-in in the modem. APN Username This is the user name your ISP has assigned to you (optional). APN Password Password to log into the ISP network (optional). Dial Number Phone number to dial for cellular network. PIN Code PIN code for the modems SIM card (optional). 4 digit number. Primary DNS The primary Domain Name Server (optional). Secondary DNS The secondary Domain Name Server (optional). Cellular Signal Strength The strength of cellular signal in dBm. Local Load Management (LLM) Settings [Support only on SC3+/IC3]
Local load management is the process of balancing the supply of electricity on the network with the electrical load by adjusting or controlling the load of each charge point in a local group which is based on Gateway/Client architecture. The Gateway IC3 must be manually set to the maximum current limitations so that it will dynamically adjust output current in each Client SC3+/IC3 by charging policy. When LLM function is on, all charge points will request for charging to Gateway, and Gateway will calculate the proper current limit and reply to each Client. Each charge point will only allow charging when received a current limit from Gateway. If disconnection occurred between a Client and Gateway then the Client will use fallback value as the limitation. Local Load Management Enable or disable Local Load Management function. This function can only be enabled in a Gateway or Client charge point. Basic/Smart/Smart Plus/Intelligent Charger-32A 56 User Manual Rev 1.11 HINT: If user changes Network Mode setting, then related settings will also change automatically such as Connectivity, Local Load Management. The default value is as follow:
Direct Not used Gateway LAN IP Not used Gateway LAN Port Max Group Number Not used Group Use External Gateway Not used Not used Gateway Serial Number Auto Connectivity Disable, not changeable Local Load Management Client Gateway Default value, not changeable Not used Default value, not changeable Not used Default value, not changeable Not used Yes or No Yes or No Not used Used Wi-Fi, not changeable Wi-Fi or Cellular Enable Enable Charging Policy The charging policy for LLM Gateway to decide the charging current for each charge point. Valid options are:
1) UD (default): Uniform Distribution. The maximum amperage is divided by total numbers of charging EV, i.e. each EV will use the same charging current. 2) FIFS: First In First Serve. Group ID An identity of the LLM group. A slave with different group identity will be rejected when attempting to connect to Gateway. Group Size The total number of charge points in the LLM group. This value is only used in Gateway. Max Amperage Grid Connection Total ampere of each phase allowed loading for the group of charge points at the same time. This value is only used in Gateway. Fallback Current The fallback current when Client is not able to communicate with Gateway. Gateway will overwrite fallback current in Client with its own value when Client connected to Gateway. Basic/Smart/Smart Plus/Intelligent Charger-32A 57 User Manual Rev 1.11 Note Any option followed by a star mark (*) means the setting need to reboot to take effect. When these value changed and applied the web portal will display a reminder message box for rebooting the charge point. Basic/Smart/Smart Plus/Intelligent Charger-32A 58 User Manual Rev 1.11 Maintenance This page includes some maintenance functions. 3.10.1 Reboot Command Reboot: To restart the charge point. Reset to MFG default: To reset to the factory default settings. Charging Profile Data HINT: Charging Profile is defined in OCPP 1.6 specification for smart charging. A charging profile consists of a charging schedule, which is basically a list of time intervals with their maximum charge power or current, and some values to specify the time period and recurrence of the schedule. Show All Charging Profile Data: To show the list of Charging Profiles. There will be a display window. The data display here is a RAW data, usually for diagnostic use. Basic/Smart/Smart Plus/Intelligent Charger-32A 59 User Manual Rev 1.11 Clear All Charging Profile Data: To clear all Charging Profile data. Local Authorization HINT: Local authorization is defined in OCPP 1.6 specification. There are two local list: Local Authorization List and Authorization Cache List. The Local Authorization List is a list of identifiers that can be synchronized with the Central System. An Authorization Cache autonomously maintains a record of previously presented identifiers that have been successfully authorized by the Central System. Show Local Authorization List: To show the list of Local Authorization. Each line of the list shown below indicates a RFID card info. The syntax is CARD_IDTAG|EXPIRY_DATE|PARENT_CARD_IDTAG|CARD_STATUS Basic/Smart/Smart Plus/Intelligent Charger-32A 60 User Manual Rev 1.11 Clear Local Authorization List: To clear the list of Local Authorization. Upload List: Upload a csv file which including card info to Local Authorization List. A csv file is a plain text file which each line represent a RFID card info. The format of a card info is as follow:
CARD_IDTAG,EXPIRY_DATE,PARENT_CARD_IDTAG,CARD_STATUS CARD_IDTAG: 8 ~ 20 character RFID card ID tag combined with alphabet or numbers. EXPIRY_DATE: The date at which idTag should be removed from the Authorization Cache. Format is YYYY-MM-DDThh:mm:ss.ttt which indicates a date in AD. Example: 2019-12-31T16:00:00.000 PARENT_CARD_IDTAG: the parent-identifier of the card. The format is same as CARD_IDTAG. CARD_STATUS: This contains whether the idTag has been accepted or not by the Central System. Valid options are Accepted, Blocked, Expired or Invalid. This string is case sensitive. Sample data: 0123456789ABCD,2019-12-31T16:00:00.000,PARENTID,Accepted Show Authorization Cache List: To show the list of Authorization Cache. Each line of the list shown below indicates a cached RFID card info. The syntax is CARD_IDTAG|EXPIRY_DATE|PARENT_CARD_IDTAG|CARD_STATUS|CACHED_DATE Basic/Smart/Smart Plus/Intelligent Charger-32A 61 User Manual Rev 1.11 Clear Authorization Cache List: To clear the list of Authorization Cache. Upload Cache: Upload a csv file which including cached card info to Authorization Cache List. A csv file is a plain text file which each line represent a cached RFID card info. The format of a cached card info is as follow:
CARD_IDTAG,EXPIRY_DATE,PARENT_CARD_IDTAG,CARD_STATUS,CACHED_DATE CARD_IDTAG: 8 ~ 20 character RFID card ID tag combined with alphabet or numbers. EXPIRY_DATE: The date at which idTag should be removed from the Authorization Cache. Format is YYYY-MM-DDThh:mm:ss.ttt which indicates a date in AD. Example: 2019-12-31T16:00:00.000 PARENT_CARD_IDTAG: the parent-identifier of the card. The format is same as CARD_IDTAG. CARD_STATUS: This contains whether the idTag has been accepted or not by the Central System. Valid options are Accepted, Blocked, Expired or Invalid. This string is case sensitive. CACHED_DATE: The date that the idTag be cached. Format is identical to EXPIRY_DATE. Sample data: 0123456789ABCD,2019-12-31T16:00:00.000,PARENTID,Accepted,2018-3-22T16:00:00 3.10.2 Firmware upgrade To upgrade the firmware of the charge point, you need to download the upgrade image file to your local hard disk, and then click the Choose File button to locate the firmware file on your computer. Once you have selected the new firmware file, click the Upload button to start the upgrade process. After s successful upgrade, the web portal will be log out and charge point will reboot. Although the web portal does not forbid upload firmware to previous version, but since the design of firmware upgrade file is including all backward modifications, downgrading firmware may cause unpredicted problem and is not recommended. Basic/Smart/Smart Plus/Intelligent Charger-32A 62 User Manual Rev 1.11 EVSE Status To check the specific information of EVSE, you can click the corresponding buttons:
Show Control Unit State: To display the information of the control unit of charge point. Mostly the function regarding to charging and safety. Show Network Unit State: To display the information of the network board of charge point. Mostly the function regarding to network connection and remote management. Show Net Profile State: To display the information of the network connectivity and settings of charge point. Show Device State: To display the information of the device service/connection between charge point and OCPP server/network connectivity. Basic/Smart/Smart Plus/Intelligent Charger-32A 63 User Manual Rev 1.11 LLM Status (SC3+/IC3 support only) 3.12.1 LLM information This page shows the Local Load Management information of the charge point. For more LLM description, please refer to section 3.9.4. Network Operation Mode: Indicates the charge point is in Direct mode, a Gateway or a Client. LLM Mode: Indicates Local Load Management function is enabled or disabled. Network Status: Indicates if the charge point is online or not. Gateway Status: Indicates if the charge point is connected to the Gateway if its a Client. For Direct and Gateway, it always shows Connected to Gateway. Network Active Device: Indicates the Network connected via which device. It could be Offline, Wi-Fi or Cellular. Local Load Management Status: Display connected charge points, total charge points, Group ID of the LLM group as well as a full table of detail information each charge point if this charge point is Gateway. Basic/Smart/Smart Plus/Intelligent Charger-32A 64 User Manual Rev 1.11 3.12.2 Gateway/Client group table If the charge point is Gateway, the following LLM Group Table is present. Index: The order of the charge point. The index is first connected to Gateway first showed. Serial Number: The serial number (Charge Point Identity) of each charge point. IP: The private local IP address in LLM group of each charge point. Wire Type: The power source wire type of each charge point. Request: The requested current of each charge point PWM: The PWM (charger allowed) current of each charge point Phase 1, Phase 2, Phase 3: The real current loaded by the vehicles of each charge point. For Intelligent Charger-32A only Phase 1 has current. Basic/Smart/Smart Plus/Intelligent Charger-32A 65 User Manual Rev 1.11 Security 3.13.1 Change password To change password, first choose user you want to change password. There are two default users admin and maintain. Only admin user can access Security Page. Enter old password and new password then press Apply button to change password of the user. To reset password of all users, press Reset password of all users button. Basic/Smart/Smart Plus/Intelligent Charger-32A 66 User Manual Rev 1.11 4 Operations Charging status indicators Table 4-1 Charging status indicators LED Indicator Description Definition Not illuminated Power Off Green Steady Ready Green Flashing Flashing green (Fast): Authorized, wait for EV Connect Flashing green (Slow): Suspend (Occupying) Blue Flashing Flashing blue (Slow): Charging Red Steady Unrecoverable Fault Red Flashing Recoverable Fault Purple Steady Reserved (from OCPP Service) Yellow Steady Out of Service Yellow Flashing Booting / Firmware Upgrading Basic/Smart/Smart Plus/Intelligent Charger-32A 67 User Manual Rev 1.11 Authorization (for SC3+/IC3 only) Before the owner of an electric vehicle can start or stop charging, the Charge Point has to authorize the operation. 4.2.1 Online Authorization Description:
Generally, before the owner of an electric vehicle can start or stop charging, the EVSE has to authorize the operation. The EVSE SHALL only supply energy after authorization. 4.2.2 Local Authorization Description:
Synchronized with the Central System when EVSE is Online. To improve the experience for users, the EVSE MAY support local authorization when EVSE is offline, and faster authorization response time when communication between Charge Point and Central System is slow. Basic/Smart/Smart Plus/Intelligent Charger-32A 68 User Manual Rev 1.11 Charging an Electric Vehicle (EV) Choices of start charging are as below:
4.3.1 Plug and Charge Insert the charging plug into the EV 1. 2. Charging session started Figure 4-1 Connect the charging plug to the EV Basic/Smart/Smart Plus/Intelligent Charger-32A 69 User Manual Rev 1.11 4.3.2 RFID card (for SC3+/IC3 only) Insert the charging plug into the EV 1. 2. Swipe card 3. Waiting for authorizing 4. Charging session started Stop charging 1. Unplug any time (disconnect the charging plug from EV to stop charging session) 2. Session ended (please return the connector to the holster) 4.4.1 Interrupt charging Please refer to STOP CHARGING section for more information. 4.4.2 Auto restart When a charging session is interrupted due to a temporary error condition, the charge point will automatically restart charging when the cause of the temporary error condition returns to normal. Status indicator lights remain flashing RED until the error condition is resolved. Temporary error conditions include: Over Current, Over Voltage, Under Voltage, and Over Temperature. For Over Current conditions: The charging session will be stop while OC occurs. After recovery from OC for 30 seconds, the charge point will automatically restart charging for three times. When charging session stopped due to CCID trip, the charge point will try to restart after 15 minutes for 3 times. 4.4.3 Power outage recovery When power resumes after an outage, the charge point restarts automatically with a delay ranging from 120 to 720 seconds. The delay is designed to avoid impacting the utility grid when multiple charge points are in the same area attempting to resume charging simultaneously. Basic/Smart/Smart Plus/Intelligent Charger-32A 70 General care User Manual Rev 1.11 The exterior of the charge point is designed to be waterproof and dust proof. To ensure proper maintenance of the charge point, follow these guidelines:
Despite the water resistance of the enclosure, when cleaning it is preferred to not direct streams of water at the unit. Clean with a soft, damp cloth. Make sure the charging plug is put back in the holster after charging to avoid damage. Ensure the power cable is stored on the charge point after use to avoid damage. If the power cable or the charging plug is damaged, please contact Customer Support. Customer support Please contact your reseller directly for technical support. Basic/Smart/Smart Plus/Intelligent Charger-32A 71