submitted | available | document details (if available) | source link |
---|---|---|---|
emcteam Acrobat Distiller 7.0.5 (Windows) |
various | WLAN SAR POWER | Test Report | 107.80 KiB |
Only for SAR Test Report Test Report no.:
Number of pages:
Testing laboratory:
FCC listing no.:
IC recognition no.:
Tested devices/
accessories:
FCC ID:
Supplement reports:
Testing has been carried out in accordance with:
Documentation:
Test Results:
Date and signature for the contents:
WLAN Radiated Peak Output Power Test Report RM-322_WLAN power for SAR.doc Date of Report:
8 06.09.2007 Thomas Reitmayer Customers Contact person:
Customer:
TCC Nokia Salo Laboratory P.O. Box 86 Joensuunkatu 7H / Kiila 1B FIN-24101 SALO, FINLAND Tel. +358 (0) 7180 08000 Fax. +358 (0) 7180 45220 533467 5385 Phone RM-322 / Battery BL-4C, Headset HS-47 and AC- Charger AC-5 Nokia Corporation Lise Meitner Strasse 10 89081 ULM GERMANY Tel. +49 731 1754 0 Fax. +49 731 1754 6800 IC:
PPIRM-322
-
See section "Test method and limit". WLAN Radiated peak output power results are used only for SAR Test Report. 661U-RM322 The test report must always be reproduced in full; reproduction of an excerpt only is subject to written approval of the testing laboratory. The documentation of the testing performed on the tested devices is archived for 15 years at TCC Nokia. The EUT complies with the requirements in respect of all parameters subject to the test. The test results relate only to devices specified in this document. Sami Lehtonen, System Manager WLAN Radiated Peak Output Test Report
/ Template Version 1.0 T:\Projects\RM-322\EMC\Results\FCC\RM-322_WLAN power for SAR.doc Copyright TCC Nokia 1 (8) TCC Nokia Salo Laboratory P.O. Box 86 Joensuunkatu 7H / Kiila 1B FIN-24101 SALO, FINLAND Tel. +358 (0) 7180 08000 Fax. +358 (0) 7180 45220 Only for SAR Test Report 1. Summary for WLAN Radiated Peak Output Power Test Report Date of receipt Testing completed The customer's contact person Thomas Reitmayer Test Plan referred to Notes Document name 14.08.2007 05.09.2007 T:\Projects\RM-322\TestPlan_RS\RS_Testplan_RM-322.xls
-
T:\Projects\RM-322\EMC\Results\FCC\RM-322_WLAN power for SAR.doc 1.1. EUT and Accessory Information The EUT is a 3-band (GSM900/1800/1900) mobile phone with Bluetooth and WLAN. WLAN is tested with maximum rated TX power. Product Phone Battery Headset AC- Charger Type RM-322 BL-4C HS-47 AC-5E SN 004401/01/363512/9 0670389382066N524F1AW00990 0694579710112103438 3943497104090614233;0675540 HW MV 0211
-
-
4
-
-
4.1
-
SW pr3.50.1
-
-
-
DUT 12151 12154 12208 12209 1.2. Summary of Test Results WLAN Radiated peak output power for SAR Test Report Name of the test PASSED FAILED NP The EUT complies with the essential requirements in the standard. The EUT does not comply with the essential requirements in the standard. The test was not performed by the TCC Nokia Salo Laboratory. Result PASSED WLAN Radiated Peak Output Test Report
/ Template Version 1.0 T:\Projects\RM-322\EMC\Results\FCC\RM-322_WLAN power for SAR.doc Copyright TCC Nokia 2 (8) TCC Nokia Salo Laboratory P.O. Box 86 Joensuunkatu 7H / Kiila 1B FIN-24101 SALO, FINLAND Tel. +358 (0) 7180 08000 Fax. +358 (0) 7180 45220 Only for SAR Test Report CONTENTS 1. Summary for WLAN Radiated Peak Output Power Test Report .............................2 1.1. EUT and Accessory Information ............................................................................................2 1.2. Summary of Test Results.......................................................................................................2 2. Radiated peak output power......................................................................................4 Test setup ..............................................................................................................................4 2.1. Test method and limit.............................................................................................................4 2.2. 2.3. Test results.............................................................................................................................6 3. Test Equipment...........................................................................................................7 3.1. Conducted measurements .....................................................................................................7 3.2. Radiated measurements ........................................................................................................7 WLAN Radiated Peak Output Test Report
/ Template Version 1.0 T:\Projects\RM-322\EMC\Results\FCC\RM-322_WLAN power for SAR.doc Copyright TCC Nokia 3 (8) TCC Nokia Salo Laboratory P.O. Box 86 Joensuunkatu 7H / Kiila 1B FIN-24101 SALO, FINLAND Tel. +358 (0) 7180 08000 Fax. +358 (0) 7180 45220 Only for SAR Test Report 2. Radiated peak output power EUT with DUT number Accessories with DUT numbers Operation Voltage [V] / [Hz]
Result Remarks Temp [C] / Humidity [%RH] /
Air Pressure [kPa]
Date of measurements Measured by RM-322, DUT 12151 BL-4C, DUT 12154; HS-47, DUT12208;
AC-5E, DUT 12209 115 / 60 PASSED
-
19 / 40 / 99.8 04.09.2007 Sami Lehtonen 2.1. Test setup Communication Tester Tower / table controller EUT Receiver 2.2. Test method and limit The measurement is performed in the Anechoic Chamber with absorbers on the floor and measuring antenna at fixed height using 2-axis EUT position system. The turntable is rotated 360 degrees and this is repeated for both horizontal and vertical receive antenna polarizations. The EUT is placed on a nonconductive plate at 170 cm height. The substitution method is used. Substitution values at each frequencies are measured beforehand and saved to the test software. WLAN Radiated Peak Output Test Report
/ Template Version 1.0 T:\Projects\RM-322\EMC\Results\FCC\RM-322_WLAN power for SAR.doc Copyright TCC Nokia 4 (8) TCC Nokia Salo Laboratory P.O. Box 86 Joensuunkatu 7H / Kiila 1B FIN-24101 SALO, FINLAND Tel. +358 (0) 7180 08000 Fax. +358 (0) 7180 45220 Only for SAR Test Report The substitution corrections are obtained as described below:
ASUBST = PSUBST_TX - PSUBST_RX - LSUBST_CABLES + GSUBST_TX_ANT Where ASUBST is the final substitution correction including receive antenna gain. PSUBST_TX is signal generator level, PSUBST_RX is receiver level, LSUBST_CABLES is cable losses including both TX and RX cables and GSUBST_TX_ANT is substitution antenna gain. The measurement results are obtained as described below:
P [dBm] = PMEAS + ATOT Where PMEAS is receiver reading in dBm and ATOT is total correction factor including cable loss and substitution correction (ATOT = LCABLES + ASUBST). Limits for radiated peak output power measurements Limit [W]
Frequency range [MHz[
Limit [dBm]
2400 2483.5 1 30 WLAN Radiated Peak Output Test Report
/ Template Version 1.0 T:\Projects\RM-322\EMC\Results\FCC\RM-322_WLAN power for SAR.doc Copyright TCC Nokia 5 (8) TCC Nokia Salo Laboratory P.O. Box 86 Joensuunkatu 7H / Kiila 1B FIN-24101 SALO, FINLAND Tel. +358 (0) 7180 08000 Fax. +358 (0) 7180 45220 Only for SAR Test Report 2.3. Test results 2.3.1 DSSS mode, QPSK modulation, 11 Mbps data rate Channel / fC [MHz] EIRP [dBm] EIRP [W] PMEAS [dBm] ATOT [dB] Polarisation 1 / 2412 7 / 2442 11 / 2462 Result PASSED VERTICAL VERTICAL PASSED HORIZONTAL PASSED
- 26.90
- 28.00
- 28.70 49.30 49.70 49.20 0.174 0.148 0.112 22.40 21.70 20.50 WLAN Radiated Peak Output Test Report
/ Template Version 1.0 T:\Projects\RM-322\EMC\Results\FCC\RM-322_WLAN power for SAR.doc Copyright TCC Nokia 6 (8) TCC Nokia Salo Laboratory P.O. Box 86 Joensuunkatu 7H / Kiila 1B FIN-24101 SALO, FINLAND Tel. +358 (0) 7180 08000 Fax. +358 (0) 7180 45220 Only for SAR Test Report 3. 3.1. Eq. No 1742 1759 1872 1916 2039 2060 2068 2097 2111 2156 2206 2335 2347 2352 2359 2360 2362 2388
-
3.2. Eq. No 1748 1749 1875 1917 1933 1938 2006 2009 2019 2027 2028 2029 2043 2047 2051 2057 Test Equipment Conducted measurements Equipment EMI Test Receiver LISN 50 H Thermo- Hygrograph Radio Communication tester Power Supply LISN 50 H CDN-Antenna line Pulse Limiter Multimeter Digital Radio Communication Tester Signal generator GPIB Switch 2 to 1 Digital Radio Communication Tester Spectrum Analyzer Temperature Test system Serial Bus Converter Power Supply Bluetooth Tester RF Emission Software Radiated measurements Equipment Log. per. Antenna Log. per. Antenna Thermo- Hygrograph Radio Communication tester Precision half-wave dipole antennas Precision half-wave dipole antennas Radiation Reference Source Signal generator Multimeter Coupling and Decoupling Network Coupling and Decoupling Network Power Supply Band Reject Filter Band Reject Filter High Pass Filter Log. per. Antenna Type ESMI ESH3-Z5 00.02520.150700 CMTA84 PL330QMD ESH3-Z5 S1 ESH3-Z2 TX3 CMU200 SMX
-
CMU200 FSP VT4002 Serial 488A NGPX 70/5 CBT ES-K1 v.1.71 Type HL025 HL025 00.02520.150700 CMTA84 HZ-13 HZ-12 VSQ SMP 22 34401A M2 (modified) DC1 M3 (modified) DC2 Manufacturer R&S R&S Lambrecht R&S THURLBY R&S NMP R&S Tektronix R&S Used in 15C, 15B 15C, 15B 15C, 15B 15C, 15B 15C, 15B 15C, 15B 15C, 15B 15C, 15B 15C, 15B 15C, 15B R&S National Instruments R&S 15C, 15B 15C, 15B 22/24, 15C, 15B R&S Vtsch Industrietechnik IO Tech R&S R&S R&S 22/24, 15C 22/24 22/24 22/24 15C, 15B 22/24, 15C, 15B Manufacturer R&S R&S Lambrecht R&S R&S R&S MEB R&S HP MEB MEB Used in 22/24, 15C 22/24, 15C 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C 22/24, 15C 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C 22/24, 15C PL330 THURLBY WRCA824/849-0,2-6SS Wainwright WRCC1800/2000-0.2-
Wainwright 10SS 4HC1700-1-KK HL025 R&S R&S WLAN Radiated Peak Output Test Report
/ Template Version 1.0 T:\Projects\RM-322\EMC\Results\FCC\RM-322_WLAN power for SAR.doc Copyright TCC Nokia 7 (8) TCC Nokia Salo Laboratory P.O. Box 86 Joensuunkatu 7H / Kiila 1B FIN-24101 SALO, FINLAND Tel. +358 (0) 7180 08000 Fax. +358 (0) 7180 45220 Only for SAR Test Report Eq. No 2109 2110 2112 2116 2133 2134 2135 2138 2140 2142 2144 2150 2176 2180 2188 2330 2334 2348 2349 2350 2361 2398 2363 2364 2365 2366 2384 2388
-
Equipment Power Supply Multimeter Multimeter Controller Power Meter Power Sensor Coupling and Decoupling Network Ultra Broadband Antenna Biconical Antenna Log.-per.-dipol Antenna Attenuator High Pass Filter Coupling and Decoupling Network Digital Radio Communication Tester Preamplifier EMI Test receiver GPIB Switch 2 to 1 Yaesu controller Computer controller (Yaesu) Preamplifier Anechoic chamber Horn antenna Band Reject Filter Band Reject Filter Relay Switch Unit Relay Switch Unit Band Reject Filter Bluetooth Tester RF Emission Software Type PL330QMD 34401A TX3 EMCO MODEL 2090 NRVS NRV-Z32 CDN 801-M3 HL562 EMCO93110B 3146 6803.17B F-15041 CDN 801-M3 CMU200 Manufacturer THURLBY HP Tektronix ETS R&S R&S LTHI Used in 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C 22/24, 15C 22/24, 15C, 15B R&S EMCO EMCO Huber-Suhner RLC ELECTRONICS 22/24, 15C LTHI 22/24, 15C, 15B 22/24, 15C 22/24, 15C 22/24, 15C, 15B 22/24, 15C, 15B R&S MITEQ Euroshield AFS4-00100300-20-23P-
6 R&S ESIB26 National Instruments
-
YAESU G-1000DXC GS-232B YAESU AMF-6D-020180-29-20P MITEQ 3 meter semi/full anechoic chamber HF906 WRCG 832/838-
825/845/5SS WRCG1877/1883 -
1870/1890-40/6SS TS-RSP TS-RSP WRCG832/838-825/845-
40/5SS CBT ES-K1 v.1.71 R&S R&S Wainwright R&S Wainwright Wainwright R&S R&S 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C, 15B 22/24, 15C 22/24, 15C, 15B 22/24, 15C 22/24 22/24 22/24, 15C, 15B 22/24, 15C, 15B 22/24 15C, 15B 22/24, 15C, 15B WLAN Radiated Peak Output Test Report
/ Template Version 1.0 T:\Projects\RM-322\EMC\Results\FCC\RM-322_WLAN power for SAR.doc Copyright TCC Nokia 8 (8) TCC Nokia Salo Laboratory P.O. Box 86 Joensuunkatu 7H / Kiila 1B FIN-24101 SALO, FINLAND Tel. +358 (0) 7180 08000 Fax. +358 (0) 7180 45220
This product uses the FCC Data API but is not endorsed or certified by the FCC