1.0 Shibano CMWC1ZZABF EVK User Guide This document explains how to control Murata CMWC1ZZAAF. 1. Module introduction CMWC1ZZAAF, CMWC1ZZABF is a hostless wifi module which integrate wifi drvier and TCP/IP stack. The operation temperature is -20~+75degree. 2. Operation Manual EVK set up is shown in figure1. Figure1
<Set up>
1. Connect EVK and PC through USB cable UART-USB converter board USB cable to PC PC Type AAF UART WiFi module CMWC1ZZABF EVK User Guide 2. Install USB-UART converter driver (FTDI D2xx driver). Customer can download from below website. http://www.ftdichip.com/Drivers/D2XX.htm 3. Please open device manager. Customer can see USB Serial Port if driver install is succeeded. 4. Please open properties of USB serial port and change port setting as below. CMWC1ZZABF EVK User Guide CMWC1ZZABF EVK User Guide 5. Please open UART communication tool on PC such as hyper terminal. And use same port setting as 4. After connection is done, enter help, then module responds console command list. Customer can refer to command list and change setting by themselves. Page 6 of 17 CMWC1ZZABF EVK User Guide
<Sample application 1> Module control by console mode and webpage 1. If customer enters start_prov, EVK starts default access point(AP) mode setting. SSID: muRata_Hostless_Wifixxxxxxxxxxxx, xxxxxxxxxxxx is EVK mac address Security: none DHCP: available IP address: 192.168.1.1 If customer wants to change setting by themselves, pls enter stop_prov. 2. Customer can connect EVK from WiFi client(PC or smartphone, etc). Password is 12345678. Page 7 of 17 CMWC1ZZABF EVK User Guide 3. Customer can access webpage inside EVK. And change EVK setting to connect with other AP. URL: 192.168.1.1 Click Scan and select network. Page 8 of 17 CMWC1ZZABF EVK User Guide 4. Join AP network. Join WUART-Demo in this document, password is 1234567890 First, please enter AP password then click join. In actual case, customer can select any AP. After you joined WiFi network, EVK is not in AP mode and changed to client, so EVK and WiFi client will be disconnected. Page 9 of 17 CMWC1ZZABF EVK User Guide 5. You will see attached message from UART port after joined network after joined AP. EVK connects to AP now then EVK becomes client mode. EVK owns IP: 192.168.1.103 in this document. (Different IP address may be assigned in actual case, please confirm IP address.) Customer can check IP address at EVK through APs setting webpage too. 6. Connect to same AP with EVK(WUART-Demo) from other client(ex. PC), Page 10 of 17 CMWC1ZZABF EVK User Guide 7. Access 192.168.1.103 and you will see attached web page. Click any button then you will see received message from UART. Page 11 of 17 CMWC1ZZABF EVK User Guide
<Sample application 2> TCP Server Client demo 0. Please follow same procedure as <sample application 1>, 8. Connect to same AP with EVK(WUART-Demo) from other client(ex. PC), 1. Murata provides TCP server-client demo tool. (CAsySocket_s.exe) Please open the .exe file and you will see below GUI. 2. Please enter PC side IP address, its 192.168.1.101 in this document and please input server port number in random(1234 in this document). And click 3 Please send tcp_connect to EVK. tcp_connect [server ip] [sever port], server ip and server port should be same as the one which you enter into CAsySocket_s. Page 12 of 17 CMWC1ZZABF EVK User Guide 4. After connection success, CAsySocket_s receives the packet from EVK via WiFi AP. 5. Customer can receive packet from server to EVK via AP. This case, enter muRata China then click button in CAsySocket_s. Then customer can check EVK received packed by tcp_read Page 13 of 17 CMWC1ZZABF EVK User Guide 6. Customer can send packet from EVK to server. Page 14 of 17 CMWC1ZZABF EVK User Guide
<Appendix>
Console Commands:
help [<command> [<example_num>]]
- Print help message or command example. dhcpc
- Perform DHCP as a client to obtain an IP address. get_mac_addr
- Get the device MAC address. get_rssi
- Get the received signal strength of the AP (client mode only). join <ssid> <open|wpa|wpa2> [key] [ip netmask gateway]
- Join an AP. DHCP assumed if no IP address provided join_default
- Join the AP 'YOUR_AP_SSID' and obtain an IP address using DHCP join_specific <ssid> <bssid> <channel> <open|wpa|wpa2> <key> [ip netmask gateway]
- Join a specific AP. DHCP assumed if no IP address provided leave
- Leave an AP. powersave <1|0>
- Enable/disable powersave mode. scan
- Scan all enabled channels and print a list of APs found. set_ip <ip> <netmask> <gateway>
- Set a static IP. set_tx_power <0-32>
- Set the tx power in dBm. get_tx_power
- Gets the tx power in dBm. status
- Print status of the Wi-Fi and network interfaces. start_ap <ssid> <open|wpa|wpa2> <key> <channel>
- Start AP mode. stop_ap
- Stop AP mode. wifi_on
- Turn Wi-Fi device on. wifi_off
- Turn Wi-Fi device off. wifi_reset
- Reset the Wi-Fi device. antenna <0|1|3>
- Antenna selection. 3 = Auto set_country <country code>
Page 15 of 17 CMWC1ZZABF EVK User Guide
- Set country. ping <destination>
- Pings the specified IP or Host. start_dhcpd
- Starts a DHCP daemon. stop_dhcpd
- Stops the DHCP daemon. get_random
- Get a random number. join_wps <pbc|pin> [pin] [<ip> <netmask> <gateway>]
- Join an AP using WPS tcp_test_tx_server
- Waits for connection then sends TCP packets. tcp_test_rx_server
- Waits for connection then receives TCP packets. tcp_test_tx_client [server ip]
- Connects to a server then sends TCP packets. tcp_test_rx_client [server ip]
- Connects to a server then receives TCP packets. tcp_connect [server ip] [sever port]
- Connects to a server then receives TCP packets. tcp_disconnect
- Connects to a server then receives TCP packets. tcp_write [payload]
- Write to the server throug the TCP socket opened in tcp_connect. tcp_read [timeout]
- Read from the server throug the TCP socket opened in tcp_connect. start_prov
- Starts the provisioning demo mode. stop_prov
- Stops the provisioning demo mode. Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the Page 16 of 17 CMWC1ZZABF EVK User Guide user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna; Increase the separation between the equipment and receiver; Connect the equipment into an outlet on a circuit different from that to which the receiver is connected; Consult the dealer or an experienced radio/TV technician for help. In accordance with FCC Part 15C, this module is listed as a Limited Modular Transmitter device. Therefore, the final host product must be submitted to [Sychip] for confirmation that the installation of the module into the host is in compliance with the regulations of FCC and IC Canada. Specifically, if an antenna other than the model documented in the Filing is used, a Class 2 Permissive Change must be filed with the FCC. Changes or modifications not expressly approved by the manufacturer could void the users authority to operate the equipment. FCC Label Instructions The outside of final products that contains this module device must display a label referring to the enclosed module. This exterior label can use wording such as the following: Contains Transmitter Module FCC ID: [VPYABF] or Contains FCC ID:
[VPYABF]. Any similar wording that expresses the same meaning may be used. To satisfy FCC RF Exposure requirements for mobile and base station transmission devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during operation. To ensure compliance, operation at closer than this distance is not recommended. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. For final installation :
Only the antenna shown in the filing may be used If the final device is made available to non-professional users, then the antenna must either be inside the host device enclosure, or changing the antenna must be made impossible by using a glue which will make it necessary to break the antenna connector when trying to remove it. End of document Page 17 of 17
This product uses the FCC Data API but is not endorsed or certified by the FCC