Air Quality Multi Sensor PAT05 The PAT05 multi-sensor is a device that allows you to check the air quality in your home, as well as detect temperature and humidity. The PAT05 Multi-sensor is easy to use and very convenient for your home. Just set the sensor on the wall of the rooms you would like to control, and you are ready to go. Moreover, the PAT05 can be integrated to other Z-Wave certified devices, and controlled with Philio app Home Mate 2. You can now protect your family and make sure there are no gas leaks or moisture that can harm those you love the most. Set up your PAT05 to send regular notifications and take control even when not at home. This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-
Wave Plus messages to communicate to other security enabled Z-Wave Plus products. Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-WaveTM enabled networks. The product supports Over The Air(OTA) feature for the products firmware upgrade. This product can be included and operated in any Z-WaveTM network with other Z-
WaveTM certified devices from other manufacturers and/or other applications. All non-
battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. The device adopt the Z-WaveTM 500 series chip, when your Z-WaveTM network system is all made by Z-WaveTM 500 series devices. The network system will have the advantages as below. Notice:
Once you have completed the setup process, Please allow for a 7-Day settling period for the sensors to adjust to their new environment and to observe a typical cycle of air quality, based on your activity within a 1 week period. Add to/Remove from Z-WaveTM Network There are two tamper keys in the device, one is in the back side, another is in the front side. Both of them can add, remove, reset or association from Z-WaveTM network. The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to Add/Remove/associate devices Notice: Including a node ID allocated by Z-WaveTM Controller means Add or Inclusion. Excluding a node ID allocated by Z-WaveTM Controller means Remove or Exclusion. Function Add
(Inclusion) 1 Description 1. Have Z-WaveTM Controller entered inclusion mode. 2. Pressing tamper key three times within 2 seconds to enter the node ID allocated by Z-Wave Controller means exclusion. inclusion mode. 3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds. 1. Have Z-WaveTM Controller entered exclusion mode. 2. Pressing tamper key three times within 2 seconds to enter the exclusion mode. Node ID has been excluded. Remove
(Exclusion) 1. Pressing Include button of PAT05 three times within 2 2. seconds will enter inclusion mode. Within 1 second, press Include button of PAT05 again for 5 seconds. Reset 1. Product has a DSK string, you can key in first five digit to increment smart start process, or you can scan QR code. 2. SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity. SmartStart Association
Failed or success in including/excluding the node ID can be viewed from the Z-
Wave Controller. Z-WaveTM Message Report
* eCO2 Report:
When the eCO2 detected state changed, the device will unsolicited to send the Sensor Multilevel Report to the nodes in the group 1. Sensor Type: eCO2 (0x11)
*** eCO2 Differential percent Report***
This function default is enabled, to disable this function by setting the configuration NO.17 to 0. In the default, when the eCO2 is changed to percentage, the device will report eCO2 information to the nodes in the group 1. Caution 1: If the configuration No.3, No.4, No.5, No.6 and No.7 is setting to 0 this functionality is useless.
* TVOC Report:
When the TVOC detected state changed, the device will unsolicited to send the Sensor Multilevel Report to the nodes in the group 1. Sensor Type: TVOC (0x27)
*** TVOC Differential percent Report ***
This function default is enabled, to disable this function by setting the configuration NO.18 to 0. 1. The PAT05 is an always listening Z-Wave device, so In the default, when the TVOC is changed to percentage, the device will report TVOC associations may be added or removed by a controller at any time. Or If your controller requires to have the PAT05 send a information to the nodes in the group 1.
'node information frame' or NIF for associations, then Caution 1: If the configuration No.8, No.9, No.10, No.11 and No.12 is setting to 0 or pressing the On/Off button three times within 2 seconds will cause the PAT05 to send its NIF. 100, this functionality is useless.
Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a 2
* Timing Report:
Z-Wave Configuration Settings Beside the event triggered could report message, the device also support the timing unsolicited report of the status. Notice:
eCO2 report: Every 3 minute report once in default.
* All of the configuration, the data size is 1. It could be changed by setting the configuration NO. 14.
* The configuration mark with star(*), means after the remove the setting still keep, TVOC report: Every 6 hours report once in default. don't reset to factory default. Unless the user execute the RESET procedure. It could be changed by setting the configuration NO. 15.
* The reserve bit or not supported bit is allowed any value, but no effect. Notice: The configuration NO. 14 and 15 could be setting to zero to disable the auto report. And the configuration NO. 16 could change the tick interval, the default value is 3, if setting to 1, that means the minimum auto report interval will be one minute. Security Network The device support the security function. When the device included with a security controller, the device will auto switch to the security mode. In the security mode, the follow commands need using Security CC wrapped to communicate, otherwise it will not response. COMMAND_CLASS_VERSION_V3 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_NOTIFICATION_V8 COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 COMMAND_CLASS_SENSOR_MULTILEVEL_V11 3 NO
. Name Def. Valid Description NO
. Name Def. Valid Description 3 eCO2 Threshold line 1 eCO2 difference return:
6 1 ~ 100 The Unit is 100ppm. 4 5 6 7 8 9 10 11 12 eCO2 Threshold line 2 8 1 ~ 100 eCO2 Threshold line 3 10 1 ~ 100 eCO2 Threshold line 4 16 1 ~ 100 eCO2 Threshold line 5 TVOC Threshold line 1 TVOC Threshold line 2 TVOC Threshold line 3 30 1 ~ 100 1 2 6 1 ~ 100 1 ~ 100 1 ~ 100 TVOC Threshold line 4 22 1 ~ 100 TVOC Threshold line 5 55 1 ~ 100 0 means turn off eCO2 detected function. eCO2 difference return:
The Unit is 100ppm. 0 means turn off eCO2 detected function. eCO2 difference return:
The Unit is 100ppm. 0 means turn off eCO2 detected function. eCO2 difference return:
The Unit is 100ppm. 0 means turn off eCO2 detected function. eCO2 difference return:
The Unit is 100ppm. 0 means turn off eCO2 detected function. TVOC difference return:
The Unit is 100ppb. 0 means turn off TVOC detected function. TVOC difference return:
The Unit is 100ppb. 0 means turn off TVOC detected function. TVOC difference return:
The Unit is 100ppb. 0 means turn off TVOC detected function. TVOC difference return:
The Unit is 100ppb. 0 means turn off TVOC detected function. TVOC difference return:
The Unit is 100ppb. 0 means turn off TVOC detected function. 13 Customer 1 All Customer function switch, using bit
(*) Function control. 1 0 0 0 0 0 0 0 range is from 0x00 ~ 0xFF. Bit0: Tamper On/Off (1:On, 0:Off) Bit1: Reserve. Bit2: Reserve. Bit3: Reserve. Bit4: Reserve. Bit5: Reserve. Bit6: Reserve. Bit7: Reserve. 14 ECO2 Auto Report Time 1 0 ~ 127 0 means turn off auto report battery. The default value is 1. The tick time can The interval time for auto report the eCO2. setting by the configuration No.16. The interval time for auto report the TVOC. 1 0 ~ 127 0 means turn off auto report illumination. 15 TVOC Auto Report Time 16 Auto Report Tick Interval 3 0 ~ 0xFF The default value is 1. The tick time can setting by the configuration No.16. The interval time for auto report each tick. Setting this configuration will effect configuration No.14 and No.15. The unit is 1 minute. Caution1: Setting to 0 means turn off all auto report function. Caution2: The value is unsigned byte, the range is from 0x00 ~ 0xFF. Caution: The value is unsigned byte, the 17 eCO2 10 1~100% The eCO2 Differential to report. 4 NO
. Name Def. Valid Description 0 means turn off this function. The unit is percentage. Configuration Notification Firmware Update Meta Data Enable this function the device will detect Supervision Differential percent Report TVOC every percentage. And when the lightSensor is over 10 percentage, it will continue report. The TVOC Differential to report. 0 means turn off this function. The unit is percentage. 1 8 4 1 2 Highest granted Security Class Highest granted Security Class Highest granted Security Class None None Transport Service Sensor multilevel 11 Highest granted Security Class Over The Air (OTA) Firmware Update 18 Differential 10 1~100%
Enable this function the device will detect The device supports Z-Wave firmware update via OTA. percent Report every percentage. Before starting the update, please remove the front case of the device otherwise the Z-Wave Supported Command Class And when the lightSensor is over 10 percentage, it will continue report. hardware check will fail. Let the controller into firmware update mode, and press the front tamper key once to start the update. After firmware download is completed, the LED light will flash intermittently. Command Class Version Required Security Class Z-Wave Plus Info Version Manufacturer Specific Security 2 Device Reset Locally Association Association Group Information Powerlevel Basic 2 3 2 1 1 2 1 1 1 None Highest granted Security Class Highest granted Security Class None Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class Highest granted Security Class Overview 5 Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. Philio Technology Corporation 8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan(R.O.C) www.philio-tech.com Specifications Rated Voltage DC5V from USB Range Minimum 40M in door and 100M in outdoor line of sight Operating Temperature
-10C ~ 40C (85% humidity) Storage Temperature Location Dimension TVOC eCO2 Frequency Range
-20 C ~ 60C Indoor use only 65(L) x 44.1 (W) x 56.3 (H) mm 0-60000ppb 400-60000ppm (estimates carbon dioxide level
(eCO2)) 868.40MHz; 869.85MHz (EU) 908.40MHz; 916.00MHz (USA/Canada) 916MHz (Israel) RF Maximum Power (peak) +5dBm (peak) for EU RED directive RF Maximum Power
(Average)
-10dBm (Average) for EU RED directive RF Modulation Type FSK (Frequency-Shift Keying) FCC ID RHHPAT05 6 Warning Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new once, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge. FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from Increase the separation between the equipment and receiver. that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 7
This product uses the FCC Data API but is not endorsed or certified by the FCC