submitted | available | document details (if available) | source link |
---|---|---|---|
March 02 2016 | April 02 2016 |
various | RF Exposure Information (MPE) rev 2 | RF Exposure Info | 64.46 KiB | March 02 2016 / April 02 2016 |
RF Exposure Report Report No.: SA151111D09 FCC ID: P27NA502 Test Model: NA502 Series Model: NA502xxxxxxxx, G450xxxxx, VeraPlusxxxxx (The x in model name can be 0 to 9, A to Z, blank or - , for marking purpose) Received Date: Nov. 11, 2015 Test Date: Nov. 16 ~ Dec. 18, 2015 Issued Date: Dec. 25, 2015 Applicant: Sercomm Corp. Address: 8F, No. 3-1, YuangQu St., NanKang, Taipei 115, Taiwan, R.O.C. (NanKang Software Park) Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
(R.O.C.) This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: SA151111D09 Reference No.: 150903D02 Page No. 1 / 6 Report Format Version: 6.1.1 Table of Contents Release Control Record .................................................................................................................................. 3 Certificate of Conformity ...................................................................................................................... 4 1 RF Exposure .......................................................................................................................................... 5 2 Limits For Maximum Permissible Exposure (MPE) ............................................................................. 5 2.1 2.2 MPE Calculation Formula ................................................................................................................... 5 2.3 Classification ....................................................................................................................................... 5 Calculation Result Of Maximum Conducted Power .......................................................................... 6 3 Report No.: SA151111D09 Reference No.: 150903D02 Page No. 2 / 6 Report Format Version: 6.1.1 Release Control Record Issue No. SA151111D09 Description Original release. Date Issued Dec. 25, 2015 Report No.: SA151111D09 Reference No.: 150903D02 Page No. 3 / 6 Report Format Version: 6.1.1 1 Certificate of Conformity Product: Multiple RF Home Gateway Brand: Sercomm, MiOS Test Model: NA502 Series Model: NA502xxxxxxxx, G450xxxxx, VeraPlusxxxxx (The x in model name can be 0 to 9, A to Z, blank or - , for marking purpose) Sample Status: Engineering sample Applicant: Sercomm Corp. Test Date: Nov. 16 ~ Dec. 18, 2015 Standards: FCC Part 2 (Section 2.1091) KDB 447498 D03 KDB 447498 D01 IEEE C95.1 The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the samples EMC characteristics under the conditions specified in this report. Prepared by :
:
Approved by Report No.: SA151111D09 Reference No.: 150903D02 Annie Chang / Senior Specialist
, Date:
Dec. 25, 2015 Rex Lai / Assistant Manager
, Date:
Dec. 25, 2015 Page No. 4 / 6 Report Format Version: 6.1.1 2 RF Exposure 2.1 Limits For Maximum Permissible Exposure (MPE) Frequency Range
(MHz) Electric Field
(mW/cm2) Strength (V/m) Limits For General Population / Uncontrolled Exposure Magnetic Field Strength (A/m) Power Density Average Time
(minutes) 300-1500 1500-100,000 F = Frequency in MHz 2.2 MPE Calculation Formula F/1500 1.0 30 30 Pd = (Pout*G) / (4*pi*r2) where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 2.3 Classification The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Report No.: SA151111D09 Reference No.: 150903D02 Page No. 5 / 6 Report Format Version: 6.1.1 3 Calculation Result Of Maximum Conducted Power Function Frequency Band Max Power
(dBm) Antenna Gain
(dBi) Distance
(cm) WLAN 2412 ~ 2462MHz WLAN 5180 ~ 5240MHz WLAN 5475 ~ 5825MHz BT LE 2402 ~ 2480MHz Zigbee 2405 ~ 2480MHz 28.27 19.99 18.82
-2.17 18.89 Z-Wave 908.40MHz
-12.83 7.11 7.01 7.01 3.6 4 0 20 20 20 20 20 20 Power Density
(mW/cm2) Limit
(mW/cm2) 0.6866 0.0997 0.0762 0.0003 0.0387 1 1 1 1 1 0.0000104 0.61 NOTE:
2.4GHz: Directional gain = 4.1dBi + 10log(2) = 7.11dBi 5.0GHz: Directional gain = 4.0dBi + 10log(2) = 7.01dBi Z-Wave: 82.4dBuV/m=-12.83dBm Conclusion:
The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + etc. < 1 CPD = Calculation power density LPD = Limit of power density WLAN 2.4GHz + WLAN 5GHz + BE LE + Zigbee + Z-Wave
= 0.6866 + 0.0997 + 0.0003 + 0.0387 + 0.000017= 0.825317 Therefore the maximum calculation of this situation is 0.825317, which is less than the 1 limit. FREQUENCY BAND (MHz) MAX POWER (dBm) WIFI (5.0G) WIFI (2.4G) BT LE Zigbee
-
-
19.99 18.82 28.27
-
-
-
-2.17
-
-
-
18.89
-
-
-
2400 5180 ~ 5240 5745 ~ 5825
--- END ---
Z-Wave
-12.83
-
-
-
TOTAL POWER
(dBm)
-12.83 28.75 19.99 18.82 POWER LIMIT
(dBm) 30 30 30 30 Report No.: SA151111D09 Reference No.: 150903D02 Page No. 6 / 6 Report Format Version: 6.1.1
This product uses the FCC Data API but is not endorsed or certified by the FCC