submitted | available | document details (if available) | source link |
---|---|---|---|
December 10 2016 |
various | Test Report | Test Report | 1.70 MiB | December 10 2016 |
FCC Radio Test Report FCC ID: P27SWESW01N This report concerns (check one): Original Grant Class II Change Project No. Equipment Model Name Applicant Address
: 1608040
: Z-Wave Binary Switch
: SW-ESW01Nxxxxxxxx, SW-BSW01Nxxxxxxxx (the 1st x should be blank or - ; the rest x could be 0 to 9, A to Z, blank or ,for marketing purpose)
: Sercomm Corporation
: 8F, No. 3-1, YuanQu St., NanKang, Taipei, Taiwan 115 Date of Receipt Date of Test Issued Date Tested by
: Aug. 08, 2016
: Aug. 08, 2016 ~ Aug. 24, 2016
: Aug. 25, 2016
: BTL Inc. Testing Engineer Technical Manager Authorized Signatory
:
:
:
(Rush Kao)
(Jeff Yang)
(Andy Chiu) B T L I N C . B1, No.37, Lane 365, Yang Guang St., Nei-Hu District, Taipei City 114, Taiwan. TEL:+886-2-2657-3299 FAX: +886-2- 2657-3331 Report No.: BTL-FCCP-1-1608040 Page 1 of 60 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufactures responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. BTLs report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and BTL-self, extracts from the test report shall not be reproduced except in full with BTLs authorized written approval. and accredited by the conformity assessment authorities listed in this test report. BTLs laboratory quality assurance procedures are in compliance with the ISO Guide17025 requirements, Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Report No.: BTL-FCCP-1-1608040 Page 2 of 60 Table of Contents Page 1 . CERTIFICATION 2 . SUMMARY OF TEST RESULTS 2.1 TEST FACILITY 2.2 MEASUREMENT UNCERTAINTY 3 .GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT 3.2 DESCRIPTION OF TEST MODES 3.3 BLOCKDIAGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED 3.4 DESCRIPTION OF SUPPORT UNITS 4 .EMC EMISSION TEST 4.1 CONDUCTED EMISSION MEASUREMENT 4.1.1 POWER LINE CONDUCTED EMISSION 4.1.2 TESTPROCEDURE 4.1.3 DEVIATIONFROMTESTSTANDARD 4.1.4 TESTSETUP 4.1.5 EUT OPERATING CONDITIONS 4.1.6 EUT TEST CONDITIONS 4.1.7 TEST RESULTS 4.2 RADIATED EMISSION MEASUREMENT 4.2.1 RADIATED EMISSION LIMITS 4.2.2 TESTPROCEDURE 4.2.3 DEVIATIONFROMTESTSTANDARD 4.2.4 TESTSETUP 4.2.5 EUT OPERATING CONDITIONS 4.2.6 EUT TEST CONDITIONS 4.2.7 TEST RESULTS (BELOW 30MHz) 4.2.8 TEST RESULTS (30 TO 1000 MHz) 4.2.9 TEST RESULTS(ABOVE1000 MHz) 5 .BANDWIDTH TEST 5.1 TEST PROCEDURE 5.2 DEVIATION FROM STANDARD 5.3 TEST SETUP 5.4 EUT OPERATION CONDITIONS 5.5 EUT TEST CONDITIONS 5.6 TEST RESULTS 6 .MEASUREMENT INSTRUMENTS LIST AND SETTING 7 .EUT TEST PHOTO 6 7 7 8 9 9 10 10 10 11 11 11 11 11 12 12 12 12 13 13 15 15 16 17 17 17 17 17 18 18 18 18 18 18 18 19 20 Report No.: BTL-FCCP-1-1608040 Page 3 of 60 Table of Contents ATTACHMENT A - CONDUCTED EMISSION ATTACHMENT B -RADIATED EMISSION (9KHZ to 30MHZ) ATTACHMENT C -RADIATED EMISSION (30MHZ TO 1000MHZ) ATTACHMENT D -RADIATED EMISSION (ABOVE 1000MHZ) ATTACHMENT E - BANDWIDTH Page 24 35 44 49 58 Report No.: BTL-FCCP-1-1608040 Page 4 of 60 Issued No. BTL-FCCP-1-1608040 REPORT ISSUED HISTORY Description Original Issue. Issued Date Aug. 25, 2016 Report No.: BTL-FCCP-1-1608040 Page 5 of 60
- ; the rest x could be 0 to 9, A to Z, blank or ,for marketing purpose)
: Z-Wave Binary Switch
: Sercomm
: SW-ESW01Nxxxxxxxx, SW-BSW01Nxxxxxxxx (the 1st x should be blank or 1. CERTIFICATION Equipment Brand Name Model Name Applicant Date of Test Test Sample Standard(s) The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. BTL-FCCP-1-1608040) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s).
: Sercomm Corporation
: Aug. 08, 2016 ~ Aug. 24, 2016
: Engineering Sample
: FCC Part15, Subpart C(15.249)/ ANSI C63.10-2013 Report No.: BTL-FCCP-1-1608040 Page 6 of 60 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s):
FCC Part15, Subpart C (15.249) StandardSection Test Item Judgment Remark 15.207 15.209 15.249
-
Conducted Emission Radiated Spurious Emission Bandwidth PASS PASS PASS NOTE:
(1)N/A denotes test is not applicable in this test report. 2.1 TEST FACILITY The test facilities used to collect the test data in this report:
Conducted emission Test:
C05:
(VCCI RN: C-4742; FCC RN:949005; FCC DN:TW1082) No. 68-1, Ln. 169, Sec.2, Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan Radiated emission Test (Below 1GHz):
CB15: (VCCI RN: R-4260; FCC RN:949005; FCC DN:TW1082; IC Assigned Code:20088) No. 68-1, Ln. 169, Sec.2, Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan Radiated emission Test (Above 1GHz):
CB15: (VCCI RN: G-868; FCC RN:949005; FCC DN:TW1082; IC Assigned Code:20088) No. 68-1, Ln. 169, Sec.2, Datong Rd., Xizhi Dist., New Taipei City 221, Taiwan Report No.: BTL-FCCP-1-1608040 Page 7 of 60 2.2 MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2. The BTL measurement uncertainty is less than the CISPR 16-4-2 Ucispr requirement. The reported uncertainty of measurement y U, where expanded uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. A. Conducted Measurement :
Test Site C05 Method CISPR Measurement Frequency Range 150 kHz~30MHz U, (dB) 2.04 B. Radiated Measurement :
Test Site CB11
(3m) Method CISPR Measurement Frequency Range 9kHz ~ 150kHz 150kHz ~ 30MHz U, (dB) 4.00 4.00 Test Site Method Measurement Frequency Range CB15
(3m) CISPR 30 MHz ~ 200 MHz 30 MHz ~ 200 MHz 200 MHz ~ 1, 000 MHz 200 MHz ~ 1, 000 MHz Ant. H / V U, (dB) 3.06 V H 2.58 3.50 V H 3.10 Test Site Method Measurement Frequency Range CB15
(3m) CISPR 1GHz ~ 6GHz 1GHz ~ 6GHz Ant. H / V U, (dB) 4.14 V H 4.14 Note: Unless specifically mentioned, the uncertainty of measurement has not been taken into account to declare the compliance or non-compliance to the specification. Our calculated Measurement Instrumentation Uncertainty is shown in the tables above. These are our Ulab values in CISPR 16-4-2 terminology. Since Table 1 of CISPR 16-4-2 has values of measurement instrumentation uncertainty, called UCISPR, as follows:
Conducted Disturbance (mains port) 150 kHz 30 MHz : 3.6 dB Radiated Disturbance (electric field strength on an open area test site or alternative test site) 30 MHz 1000 MHz : 5.2 dB It can be seen that our Ulab values are smaller than UCISPR. Report No.: BTL-FCCP-1-1608040 Page 8 of 60 3.GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Equipment Brand Name Model Name Model Difference Product Description PowerSource Power Rating Z-Wave Binary Switch Sercomm SW-ESW01Nxxxxxxxx, SW-BSW01Nxxxxxxxx (the 1st x should be blank or - ; the rest x could be 0 to 9, A to Z, blank or ,for marketing purpose) SW-ESW01Nxxxxxxxx ==> main board, meter board, power board, RF board SW-BSW01Nxxxxxxxx ==> main board, power board, RF board Operation Frequency Modulation Technology Data rate Field Strength AC Mains. I/P:100-120 VAC/15A 908.4~916 MHz FSK 17.2Kbps 93.80dBuV/m Note:
1. For a more detailed features description, please refer to the manufacturers specifications or the user's manual. 2. Channel List:
Channe 01 02 Table for Filed Antenna:
Ant. Manufacturer 1 N/A 3. Frequency
(MHz) 908.4 916 Model Name Antenna Type Connector Gain (dBi) N/A Internel N/A 0.14 Report No.: BTL-FCCP-1-1608040 Page 9 of 60 3.2 DESCRIPTION OF TEST MODES To investigate the maximum EMI emission characteristics generated from EUT, the test system was pre-scanning tested based on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Pretest Mode Mode 1 Final Test Mode Mode 1 Description TX Mode Description TX Mode 3.3BLOCKDIAGRAMSHOWINGTHECONFIGURATIONOFSYSTEMTESTED 3.4DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Item
-
Equipment Mfr/Brand Model/Type No. FCC ID Series No.
-
-
-
-
-
Item Shielded Type Ferrite Core
-
-
-
Length
-
Note
-
Report No.: BTL-FCCP-1-1608040 Page 10 of 60 4.EMC EMISSION TEST 4.1CONDUCTED EMISSION MEASUREMENT 4.1.1 POWER LINE CONDUCTED EMISSION (FREQUENCY RANGE 150KHZ-30MHZ) Frequency of Emission (MHz) 0.15 -0.5 0.50 -5.0 5.0 -30.0 Note:
Conducted Limit (dBV) Quasi-peak 66 to 56*
56 60 Average 56 to 46*
46 50
(1) The limit of " * " decreases with the logarithm of the frequency The following table is the setting of the receiver Receiver Parameters Attenuation Start Frequency Stop Frequency IF Bandwidth Setting 10 dB 0.15 MHz 30 MHz 9 kHz 4.1.2 TESTPROCEDURE a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipmentspowered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument. b. Interconnecting cables that hang closer than 40 cm to the groundplane shall be folded back and forth in the center forming a bundle 30 to 40 cm long. c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m. d. LISN at least 80 cm from nearest part of EUT chassis. e. For the actual test configuration, please refer to the related Item EUT Test Photos. 4.1.3DEVIATIONFROMTESTSTANDARD No deviation Report No.: BTL-FCCP-1-1608040 Page 11 of 60 4.1.4 TESTSETUP Ve rtic a l R e fe re n c e G ro u n d P la n e Te s t R e c e iv e r 4 0 c m E U T L IS N 8 0 c m H o riz o n ta l R e fe re n c e G ro u n d P la n e N o te : 1 .S u p p o rt u n its w e re c o n n e c te d to s e c o n d L IS N . 2 .B o th o f L IS N s (A M N ) a re 8 0 c m fro m E U T a n d a t le a s t 8 0 fro m o th e r u n its a n d o th e r m e ta l p la n e s 4.1.5EUT OPERATING CONDITIONS The EUT was configured for testing in a typical fashion (as a customer would normally use it).The EUT has been programmed to continuously transmit during test. This operating condition was tested and used to collect the included data. The EUT was programmed to be in continuously transmitting mode. 4.1.6EUT TEST CONDITIONS Temperature: 24C Relative Humidity: 52%
Test Voltage: AC 120V 60Hz 4.1.7 TEST RESULTS Please refer to the Attachment A. Remark:
(1) All readings are QP Mode value unless otherwise stated AVG in column ofNote. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits,the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured, but AVG Mode didnt perform in this case, a * marked in AVG Mode column of Interference Voltage Measured.
(2) Measuring frequency range from 150KHz to 30MHz. Report No.: BTL-FCCP-1-1608040 Page 12 of 60 4.2 RADIATED EMISSION MEASUREMENT 4.2.1RADIATED EMISSION LIMITS
(FCC 15.209 ) Frequencies
(MHz) Field Strength
(micorvolts/meter) Measurement Distance
(meters) 0.009~0.490 0.490~1.705 1.705~30.0 30~88 88~216 216~960 960~1000 2400/F(KHz) 24000/F(KHz) 30 100 150 200 500 300 30 30 3 3 3 3 Harmonic emissions limits comply with below 54dBuV/m at 3m. Other emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or comply with the radiated emissions limits specified in section15.209(a) limit in the table below has to be followed. Note:
(1) The tighter limit applies at the band edges.
(2) Emission level (dBuV/m)=20log Emission level (uV/m). LIMITS OF RADIATED EMISSION MEASUREMENT (FCC 15.209 ) FREQUENCY (MHz) Above 1000
(dBuV/m) (at 3m) PEAK 74 AVERAGE 54 Notes:
(1) The limit for radiated test was performed according to FCC PART 15C.
(2) The tighter limit applies at the band edges.
(3) Emission level (dBuV/m)=20log Emission level (uV/m). Spectrum Parameter Attenuation Start Frequency Stop Frequency Receiver Parameter Attenuation Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Setting Auto 1000 MHz 10th carrier harmonic Setting Auto 9kHz~90kHz for PK/AVG detector 90kHz~110kHz for QP detector 110kHz~490kHz for PK/AVG detector 490kHz~30MHz for QP detector 30MHz~1000MHz for QP detector Report No.: BTL-FCCP-1-1608040 Page 13 of 60 DWELL TIME OF PERIODIC OPERATION MEASUREMENT Report No.: BTL-FCCP-1-1608040 Page 14 of 60 4.2.2 TESTPROCEDURE a. The measuring distance of 3 m shall be used for measurements. The EUT was placed on the top of a rotating table 0.8 meter above the ground at a 3 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest radiation.(below 1GHz) b. The measuring distance of 3 m shall be used for measurements. The EUT was placed on the top of a rotating table 1.5 meter above the ground at a 3 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the highest radiation.(above 1GHz) c. The height of the equipment or of the substitution antenna shall be 0.8 m or 1.5m,the height of the test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights find the maximum reading (used Bore sight function). e. The receiver system was set to peak and average detect function and specified bandwidth with maximum hold mode when the test frequency is above 1GHz. f. The initial step in collecting radiated emission data is a receiver peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then Quasi Peak detector mode re-measured. g. All readings are Peak unless otherwise stated QP in column of Note. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didnt perform.
(below 1GHz) h. All readings are Peak Mode value unless otherwise stated AVG in column of Note. If the Peak Mode Measured value compliance with the Peak Limits and lower than AVG Limits, the EUT shall be deemed to meet both Peak & AVG Limits and then only Peak Mode was measured, but AVG Mode didnt perform. (above 1GHz) i. For the actual test configuration, please refer to the related Item EUT Test Photos. 4.2.3DEVIATIONFROMTESTSTANDARD No deviation Report No.: BTL-FCCP-1-1608040 Page 15 of 60 4.2.4 TESTSETUP
(A) Radiated Emission Test Set-Up Frequency Below 1 GHz
(B) Radiated Emission Test Set-Up Frequency Above 1 GHz Report No.: BTL-FCCP-1-1608040 Page 16 of 60
(C) For radiated emissions below 30MHz 4.2.5EUT OPERATING CONDITIONS The EUT tested system was configured as the statements of 4.1.5 unless otherwise a special operating condition is specified in the follows during the testing. 4.2.6EUT TEST CONDITIONS Temperature: 24C Relative Humidity: 52%
Test Voltage: AC 120V 60Hz 4.2.7 TEST RESULTS (BELOW 30MHz) Please refer to the Attachment B. Remark:
(1) The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible value has no need to be reported.
(2) Distance extrapolation factor = 40 log (specific distance / test distance) (dB);.
(3) Limit line = specific limits (dBuV) + distance extrapolation factor.. 4.2.8 TEST RESULTS (30 TO 1000 MHz) Please refer to the Attachment C 4.2.9 TEST RESULTS(ABOVE1000 MHz) Please refer to the Attachment D Remark:
(1) EUT Orthogonal Axis:
X - denotes Laid on TableY - denotes Vertical StandZ - denotes Side Stand
(2) During the measurements above 1 GHz it is taken care of that the EUT is always within the 3 dB cone of radiation BW of the used antenna Report No.: BTL-FCCP-1-1608040 Page 17 of 60 5.BANDWIDTH TEST 5.1TEST PROCEDURE a. The EUT was directly connected to the spectrum analyzer and antenna output port as show in b. Spectrum Setting: RBW= 3kHz, VBW=3kHz, Sweep time = Auto. the block diagram below, 5.2DEVIATION FROM STANDARD No deviation. 5.3TEST SETUP 5.4EUT OPERATION CONDITIONS The EUT tested system was configured as the statements of 4.1.5 unless otherwise a special operating condition is specified in the follows during the testing. 5.5EUT TEST CONDITIONS Temperature: 25C Relative Humidity: 55%
Test Voltage: AC 120V 60Hz 5.6 TEST RESULTS Please refer to the Attachment E Report No.: BTL-FCCP-1-1608040 Page 18 of 60 6.MEASUREMENT INSTRUMENTS LIST AND SETTING Conducted Emission Measurement Serial No. 101050 Type No. ENV216 Item Kind of Equipment Manufacturer TWO-LINE V-NETWORK Test Cable 1 2 3 EMI Test Receiver 4 Measurement Software R&S TIMES R&S EZ CFD300-NL ESR7 EZ_EMC
(Version NB-03A) C02 101433 N/A Calibrated until Jan. 26, 2017 Jun. 15, 2017 Dec. 10, 2016 N/A Radiated Emission Measurement Trilog-Broadband Item Kind of Equipment Manufacturer Schwarzbeck Schwarzbeck Antenna 1 2 3 4 5 6 7 8 9 Horn Antenna Pre-Amplifier Pre-Amplifier Test Cable Test Cable Test Cable Test Cable Test Cable EXA Spectrum Analyzer 10 11 EMI Test Receiver 12 Loop Antenna HP Agilent EMCI EMCI EMCI EMCI EMCI Agilent Agilent EMCO Type No. VULB9168-352 BBHA 9120 8447D 8449B EMC8D-NM-NM-8000 EMC104-SM-SM-2500 EMC104-NM-SM-1000 EMC104-SM-SM-5000 EMC104-SM-SM-800 N9010A N9038A 6502 D-546 Serial No. 9168-352 Calibrated until Feb. 04, 2017 Nov. 05, 2017 2944A08891 Mar. 09 2017 Jan. 24, 2017 3008A02331 Mar. 09, 2017 Mar. 09, 2017 Mar. 09, 2017 Mar. 29, 2017 Mar. 29, 2017 MY52220990 Feb. 24, 2017 MY51210215 Jan. 08, 2017 Nov. 06. 2016 150301 150303 150304 150302 150305 00042960 Item Kind of Equipment Manufacturer 1 Spectrum Analyzer R&S Bandwidth Type No. FSP-40 Serial No. 100129 Calibrated until Jan. 18, 2017 Remark: N/A denotes no model name, serial no. or calibration specified. All calibration period of equipment list is one year. Report No.: BTL-FCCP-1-1608040 Page 19 of 60 7.EUT TEST PHOTO Conducted Measurement Photos Report No.: BTL-FCCP-1-1608040 Page 20 of 60 Radiated Measurement Photos 9KHz to 30MHz Report No.: BTL-FCCP-1-1608040 Page 21 of 60 Radiated Measurement Photos 30MHz to 1000MHz Report No.: BTL-FCCP-1-1608040 Page 22 of 60 Radiated Measurement Photos Above 1000MHz Report No.: BTL-FCCP-1-1608040 Page 23 of 60 ATTACHMENT A - CONDUCTED EMISSION Report No.: BTL-FCCP-1-1608040 Page 24 of 60 Test Mode:
TX 908.4MHz _ SW-BSW01N Line Report No.: BTL-FCCP-1-1608040 Page 25 of 60 Test Mode:
TX 908.4MHz _ SW-BSW01N Neutral Report No.: BTL-FCCP-1-1608040 Page 26 of 60 Test Mode:
TX 916MHz _ SW-BSW01N Line Report No.: BTL-FCCP-1-1608040 Page 27 of 60 Test Mode:
TX 916MHz _ SW-BSW01N Neutral Report No.: BTL-FCCP-1-1608040 Page 28 of 60 Test Mode:
TX 9.6KHz _ SW-ESW01N Line Report No.: BTL-FCCP-1-1608040 Page 29 of 60 Test Mode:
TX 9.6KHz _ SW-ESW01N Neutral Report No.: BTL-FCCP-1-1608040 Page 30 of 60 Test Mode:
TX 908.4MHz _ SW-ESW01N Line Report No.: BTL-FCCP-1-1608040 Page 31 of 60 Test Mode:
TX 908.4MHz _ SW-ESW01N Neutral Report No.: BTL-FCCP-1-1608040 Page 32 of 60 Test Mode:
TX 916MHz _ SW-ESW01N Line Report No.: BTL-FCCP-1-1608040 Page 33 of 60 Test Mode:
TX 916MHz _ SW-ESW01N Neutral Report No.: BTL-FCCP-1-1608040 Page 34 of 60 ATTACHMENT B -RADIATED EMISSION (9KHZ to 30MHZ) Report No.: BTL-FCCP-1-1608040 Page 35 of 60 Test Mode:
TX Mode_908.4MHz OPEN Report No.: BTL-FCCP-1-1608040 Page 36 of 60 Test Mode:
TX Mode_908.4MHz OPEN Report No.: BTL-FCCP-1-1608040 Page 37 of 60 Test Mode:
TX Mode_908.4MHz CLOSE Report No.: BTL-FCCP-1-1608040 Page 38 of 60 Test Mode:
TX Mode_908.4MHz CLOSE Report No.: BTL-FCCP-1-1608040 Page 39 of 60 Test Mode:
TX Mode_916MHz OPEN Report No.: BTL-FCCP-1-1608040 Page 40 of 60 Test Mode:
TX Mode_916MHz OPEN Report No.: BTL-FCCP-1-1608040 Page 41 of 60 Test Mode:
TX Mode_916MHz CLOSE Report No.: BTL-FCCP-1-1608040 Page 42 of 60 Test Mode:
TX Mode_916MHz CLOSE Report No.: BTL-FCCP-1-1608040 Page 43 of 60 ATTACHMENT C -RADIATED EMISSION (30MHZ TO 1000MHZ) Report No.: BTL-FCCP-1-1608040 Page 44 of 60 Test Mode:
TX Mode_908.4MHz Vertical Report No.: BTL-FCCP-1-1608040 Page 45 of 60 Test Mode:
TX Mode_908.4MHz Horizontal Report No.: BTL-FCCP-1-1608040 Page 46 of 60 Test Mode:
TX Mode_916MHz Vertical Report No.: BTL-FCCP-1-1608040 Page 47 of 60 Test Mode:
TX Mode_916MHz Horizontal Report No.: BTL-FCCP-1-1608040 Page 48 of 60 ATTACHMENT D -RADIATED EMISSION (ABOVE 1000MHZ) Report No.: BTL-FCCP-1-1608040 Page 49 of 60 Orthogonal Axis : X Test Mode :
TX Mode_908.4MHz Vertical Report No.: BTL-FCCP-1-1608040 Page 50 of 60 Orthogonal Axis : X Test Mode :
TX Mode_908.4MHz Vertical Report No.: BTL-FCCP-1-1608040 Page 51 of 60 Orthogonal Axis : X Test Mode :
TX Mode_908.4MHz Horizontal Report No.: BTL-FCCP-1-1608040 Page 52 of 60 Orthogonal Axis : X Test Mode :
TX Mode_908.4MHz Horizontal Report No.: BTL-FCCP-1-1608040 Page 53 of 60 Orthogonal Axis : X Test Mode :
TX Mode_916MHz Vertical Report No.: BTL-FCCP-1-1608040 Page 54 of 60 Orthogonal Axis : X Test Mode :
TX Mode_916MHz Vertical Report No.: BTL-FCCP-1-1608040 Page 55 of 60 Orthogonal Axis : X Test Mode :
TX Mode_916MHz Horizontal Report No.: BTL-FCCP-1-1608040 Page 56 of 60 Orthogonal Axis : X Test Mode :
TX Mode_916MHz Horizontal Report No.: BTL-FCCP-1-1608040 Page 57 of 60 ATTACHMENT E - BANDWIDTH Report No.: BTL-FCCP-1-1608040 Page 58 of 60 Test Mode :
TX Mode_908.4MHz Frequency
(MHz) 908.4 20dB Bandwidth
(MHz) 0.910 TX Mode 99% Occupied BW
(MHz) 0.268 Report No.: BTL-FCCP-1-1608040 Page 59 of 60 Test Mode :
TX Mode_916MHz Frequency
(MHz) 916 20dB Bandwidth
(MHz) 0.916 TX Mode 99% Occupied BW
(MHz) 0.276 Report No.: BTL-FCCP-1-1608040 Page 60 of 60
This product uses the FCC Data API but is not endorsed or certified by the FCC