submitted | available | document details (if available) | source link |
---|---|---|---|
August 09 2016 | August 09 2016 | W6_USV1.0-TDE01安装指南 user Corel PDF Engine Version 15.2.0.686 |
various | Users Manual | Users Manual | 1.92 MiB | August 09 2016 |
Install Guide Wireless Access Point Model: W6_US Please read this Install Guide carefully before you start. For information that is not covered here, see the User Guide at http://www.tendacn.com Get to Know Your AP 2 PoE Out + Data PoE In + Data RST RST LED Interfaces PoE Out + Data: 100Mbps LAN Port. Connect it to a computer, etc. Only support PoE af class 2 or lower power consumption device. PoE In + Data: 100Mbps PoE/LAN Port (Supported PoE power supply). Connect this port to a PoE switch. Button RST: Press it for over 7 seconds until the LED indicator turns to be solid to restore the device to factory defaults. LED Blinking: The AP works properly. Off: The AP is not powered on, malfunctions occur or LED is disabled manually. 4 Install Your AP Detach the APs cover plate using a screw-driver as shown in the figure. Detach the cover plate AP Cover Plate
=
+
Package Contents 1 Double click Internet Protocol Version 4 (TCP/IPv4) Select Use the following IP address, and set up the computers IP address to 192.168.0.X
(X indicates a number between 2 and 253), Subnet mask to 255.255.255.0, and then click OK to save the settings. x 2 x 2 x 2 x 2 Four pairs of screws Install Guide Wireless Access Point Model: W6_US Please read this Install Guide carefully before you start. For information that is not covered here, see the User Guide at http://www.tendacn.com Install Guide Wireless Access Point 1 Ethernet Cable
* If any item is incorrect, missing, or damaged, please keep the original package and contact your reseller for immediate replacement. Network Topology 3 Wireless Access Point PoE Switch Step 2: Configure the Wireless Access Point Launch a web browser, type 192.168.0.254 in the address bar, and tap Enter on the keyboard. Type the login Username and Password (Both are admin by default) and click Login. W6_US Quick Setup: Click Quick Setup, select a mode according to your needs (Here take AP Mode as an example); customize the SSID (wireless network name), select a security mode/Cipher Type, customize the Security Key, and click Save. Router Internet LAN Setup: Click Network > LAN Setup, select a Address Mode, and complete the releated settings. Install the AP in the wall box. Verify that the Ethernet cable is positioned properly. Fasten the AP with the included screws. Adjust the screws to ensure the AP is flush with the Attach the cover plate to the AP. wall for proper fitting of the cover plate. Status Quick Setup Network LAN Setup DHCP Server Wireless SNMP Tools LAN Setup MAC Address Address Mode IP Address Subnet Mask Gateway Primary DNS Server Secondary DNS Server Device Name Ethernet Mode C8:3A:35:16:07:01 Static IP 192.168.0.254 255.255.255.0 192.168.0.1 192.168.0.1 For example:192.168.1.1 For example:255.255.255.0 Save Restpre Help
(optional) W6 _US Auto-negotiation 10M half-duplex Status Quick Setup Network Wireless SNMP Tools Quick Setup Mode SSID Security Mode Cipher Type Security Key AP Mode APClient Mode Tenda_160701 Mixed WPA/WPA2-PSK AES TKIP TKIP&AES 12345678 Save Restpre Help FAQs Q1: I cannot access the devices web UI by using the login IP address 192.168.0.254. What should I do?
A1: Ensure that your computer is connected to the device properly, and the device is powered on. Ensure that your computers IP address is set to 192.168.0.X (X is a number between 2 and 253). Clear cache of the browser, or launch another web browser. Try configuring the device on a different computer. Restore the device to factory defaults (refer to the following question) and retry. Q2: How to restore the device to factory defaults?
A2: Detach the devices cover plate, press the RST button with a needle for over 7 seconds until the LED indicator turns to be solid to restore the device to factory defaults. Tip If your computer is set to a static or fixed IP address (such as Step 1: Configure the Computer), remember to set it back to Obtain an IP address automatically and Obtain DNS server address automatically after configuration. Note:
All settings will be restored to factory defaults once you reset the device. You will need to reconfigure the device for specific purposers. 5 An electrical wall box should be pre-installed with an Ethernet cable running from the box. Connect the Ethernet cable from the wall box to a PoE switch, and connect the other end of the Ethernet cable to the LAN port on the back panel of the AP. Manage Your AP System Requirement Windows XP/7/8 or Linux Web Browser: IE8 or higher or Google Chrome On the computer that connected to the Wireless Access Point, right click the icon Step 1: Configure the Computer(Take Windows 7 as an example) or on the bottom right corner of your desktop, and then click Open Network and Sharing Center. Click Local Area Connection > Properties 2:30 PM 6/16/2016 CE Mark Warning This is a Class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. NOTE: (1) The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. (2) To avoid unnecessary radiation interference, it is recommended to use a shielded RJ45 cable. Declaration of Conformity Hereby, SHENZHEN TENDA TECHNOLOGY CO. LTD. declares that the radio equipment type W6_US is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
http://www.tendacn.com/en/service/page/ce.html Operate Frequency2412-2472 MHz EIRP Power(Max.)19.8 dBm Software Versionv1.0.0.2 FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. NOTE: (1) The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. (2) To avoid unnecessary radiation interference, it is recommended to use a shielded RJ45 cable. Technical Support United States Hotline: 1-800-570-5892 Canada Hotline: 1-888-998-8966 Skype: Tendasz Copyright 2016 Shenzhen Tenda Technology Co., Ltd. All rights reserved. Tenda is a registered trademark legally held by Shenzhen Tenda Technology Co., Ltd. Other brand and product names mentioned herein are trademarks or registered trademarks of their respective holders. Specifications are subject to change without notice. Address Info:
6-8 Floor, Tower E3, NO.1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052 Website: http:// www.tendacn.com E-mail: support@tenda.com.cn HongKong Hotline: 00852-81931998
This product uses the FCC Data API but is not endorsed or certified by the FCC