submitted | available | document details (if available) | source link |
---|---|---|---|
Adobe PDF Library 15.0 |
various | QIG EasySense SNS441 A03 rev | Users Manual | 1.49 MiB |
Note: Below data applicable only for SNS102CMP and SNS200CMP. Refer to partner documentation for information Note: Below data applicable only for SNS102CMP, SNS200CMP and SNS441CMP. Refer to partner documentation for applicable to SNS300CMP. information applicable to SNS300CMP. Electrical Information Input Voltage Current Consumption Nominal Power Consumption Standby Power Environment & Approbation Operating Ambient Temperature Range Operating Humidity Storage Temperature Storage Humidity Max Case Temperature (Tcase) Agency Approbations Certification Limited Warranty Digital Interface Other Status Indicators No. Drivers per Sensor Field Configuration Powered by SR driver low-voltage interface 13mA 200mW
< 1 W on luminaire level, including driver standby power 0C to 55C 0 95% non condensing
-25C to 85C 0-95% non condensing 55C UL, CSA; Tested and approved for use in plenums; For use in non-fire-rated installations only California Title 20 5 years Xitanium SR None Four drivers per sensor maximum; Wiring polarity must be maintained via NFC ior IR. Parameters set via Philips field apps Operation and Configuration via Mobile App EasySense operates immediately upon installation and energization without further commissioning. If changes from default settings are desired, EasySense can be configured via Philips field apps through NFC or IR. For a complete description of the features and default settingsas well as details on the apprefer to www.philips.com/easysense. FCC and IC Statement This device complies with part 15 of the FCC rules for the United States and Industry Canada (IC) license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by Philips could void the users authority to operate this equipment. This product is intended for commercial use only. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. Dclaration De Conformit La Fcc/Ic Ce dispositif est conforme la partie 15 des rgles de la Federal Communications Commission (FCC) des tats-Unis et dIndustrie Canada (IC) exempts de licence RSS norme(s). Son fonctionnement est assujetti aux deux conditions suivantes
: (1) Ce dispositif ne doit pas provoquer de brouillage prjudiciable, et (2) il doit accepter tout brouillage reu, y compris le brouillage pouvant entraner un mauvais fonctionnement. Tous les changements ou modifications non expressment approuvs par Philips, sont susceptibles dannuler le droit de lutilisateur se servir de cet quipement. Ce produit est exclusivement destin un usage commercial. Cet quipement doit tre install et utilis avec une distance minimale de 20 cm entre le radiateur et votre corps. 2018 Philips Lighting Holding B.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. philips.com/easysense PLt-1621QG_EasySenseCMP QIG 08/18 Document #: 4435 290 61451 REV. C Philips Lighting North America Corporation 10275 W. Higgins Road, Rosemont IL 60018 Tel: 800-322-2086 Fax: 888-423-1882 Customer/Technical Service: 800-372-3331 OEM Support: 866-915-5886 Philips Lighting Canada Ltd. 281 Hillmount Rd, Markham, ON, Canada L6C 2S3 Tel. 800-668-9008 Transceiver EasySense Ceiling-Mount Philips EasySense Quick Installation Guide Sensor Part Number Commercial Product Name EasySense Ceiling-Mount Sensor Order Code SNS102CMP (514851) SNS200CMP (516666) SNS300CMP (517839) SNS441CMP Compatible LED Drivers Driver Model Number Description XI040C110V054VPT1 XI075C200V054VPT1 Xitanium 40W 0.1-1.1A 27-54V 120-277V SR Xitanium 75W 0.1-2.0A 27-54V 120-277V SR Specifications available at www.philips.com/XitaniumSR. Wiring Diagram Connectors EASYSENSE WHITE RED 36-inch 18AWG solid lead wires in plenum-rated jacket from sensor stripped to 3/8". Connect white wire to brown (SR-) and red wire to purple (SR+) on driver. Four drivers per sensor maximum. Polarity must be maintained. SR-
SR+
NC GROUND LINE NEUTRAL XITANIUM SR LED DRIVER NFC ANTENNA LED+
LED+
LED-
LED-
RSET2 SGND Connection White Black Green Purple Brown Color Neutral Line Ground SR+
SR-
Connection Red Blue Orange Green Color LED+
LED-
RSET2 SGND Transceiver Dimensions (in/mm) Installation Notes:
1. For use in non-fire-rated installations only. 2. Remove power from fixtures/drivers before performing any electrical work. 3. Up to (4) drivers maximum can be connected to (1) EasySense. Polarity must be maintained. 1.811 (46) REF. 1.240 (31.5) REF. Step 1: Drill 2.5-inch hole in ceiling. It may be more practical to remove the ceiling tile and drill from the backside depending on material. Step 2: Feed wires from sensor into ceiling hole. Wire length provided is 36-inches. Cable jacket provided is plenum-rated. Add additional wire length if necessary
(18AWG solid wire recommended). 2.4 8 0 (6 3) R E F. 2.9 1 3 ( 7 4 ) R F . E Step 3: Compress spring clips on sensor and insert into ceiling hole. Step 4: Sensor will clamp into place. Turn sensor to appropriate position. Step 5: Connect the wires from the sensor to the LED Driver in the fixture. Connect the white wire from the sensor to the brown (SR-) terminal on the driver. Connect the red wire from the sensor to the purple (SR+) terminal on the driver. Follow fixture manufacturers instructions for accessing the driver. Configuring Sensor Parameters EasySense operates upon energization with no further commissioning. See Transceiver datasheet for sensor presets and parameters that can be changed during installation. Refer to Operation and Configuration via Mobile App on last page for further details.
This product uses the FCC Data API but is not endorsed or certified by the FCC