submitted | available | document details (if available) | source link |
---|---|---|---|
July 14 2014 | July 14 2014 | Fingerprint Solutions of Suprema Karl Microsoft® PowerPoint® 2013 |
various | User Manual | Users Manual | 1.43 MiB | July 14 2014 |
http://www.emc2000.co.kr FCC TEST REPORT Report No.: EMC-FCC-R0170 User Manual EMC compliance Ltd. 65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 443-390, Korea 82-31-336-9919 (Main) 82-505-299-8311 (Fax) This test report shall not be reproduced, except in full, Without the written approval. Xpass S2 Intelligent IP Access Control Reader Installation Guide EN 101.00.XPS2 V1.00 www.supremainc.com Xpass S2 Important Safety Information Carefully review the information within the user manual before installing or operating the device. Pay careful attention to the warning and cautions below as they are here to prevent any risk or damage to any person(s) or property associated with the device. Warning Caution Failure to heed these warnings may lead to serious injury or even death!
Failure to heed these cautions may lead to minor injury or damage the device. Installation Installation Do not install the device near heat sources such as radiators, Do not leave cables (especially power cables) exposed to heat registers, and stoves. the outer environment. Do not install the device near areas of large electromagnetic Do not install the device near objects with a strong magnetic interference. field such as magnets, computer monitors (especially CRT), TV screens and speakers. Usage Usage Do not disassemble, repair or reconstruct the device. Disassembling the device will void the warranty. Do not drop or apply any physical shock/impact to the device. Regularly clean the product with a soft dry cloth; avoid Only use the device its intended use. benzene or alcohol. Contact your nearest Suprema dealer for technical support. Copyright 2007 Suprema Inc. 2 Xpass S2 Contents Product Components Optional Accessories Name of Each Part LED Status Reset Network Settings Product Dimension Cables and Connectors Power Connection LAN Connection RS485 Connection Relay Connection Digital Input Connection Wiegand Input/Output Installation of Wall-mount Bracket Installation of Extended Bracket Installation Reference Specification Electrical Specification FCC Rules 4 5 6 7 8 9 10 11 12 14 16 19 21 22 23 24 27 28 29 Copyright 2007 Suprema Inc.
#
Xpass S2 Product Components Basic Components Xpass S2 Wall Bracket Wall Mounting Screws Screw Anchors Shrinkable Tubes Software CD
(2 ea)
(2 ea) Diode
(1 ea) The components used above may differ depending on the installation environment. Copyright 2007 Suprema Inc. 4 Xpass S2 Optional Accessories Extended Bracket 12VDC Adaptor Secure I/O Plastic Stand Copyright 2007 Suprema Inc. 5 Xpass S2 Name of Each Part Copyright 2007 Suprema Inc. 6 Xpass S2 LED Status LED Status by Color Color Green Red Pink Sound Description Beep x 3 Authorization Success Long Beep Authorization Fail Short Beep On Processing Flicker Blue/Skyblue Color per 2 sec Flicker Red/Pink Color per 2 sec Flicker Blue/Red Color per 2 sec N/A N/A N/A Flicker Blue/Yellow Color per 2 sec N/A For first operation, red LED is blinking by every 2 seconds. For normal operation, red LED is blinking by every 2 seconds. N/A N/A Yellow LED is blinking shortly. N/A Normal Locked Initialized Time due to the Internal Battery Discharge IP address is not assigned when terminal is set as Use in the DHCP of TCP/IP setting Failed. Please contact to your distributor or Suprema Security Status Terminal is used or received a packet to get IP address when terminal is set as Use in the Idle status or TCP/IP Setting Copyright 2007 Suprema Inc. 7 Xpass S2 Reset Network Settings When you install the Xpass S2 or forget the network settings value of Xpass S2 in use, can initial the network settings value (TCP/IP address, RS-485 setting) in the switch of Xpass S2s back side as follows;
Reset Network Settings 1. Press the Reset button located on the rear of the Xpass S2 for 3 seconds or more. 2. Use the BioStar (Ver. 1.8 or higher) to connect to the Xpass S2 using the default settings. Default Network Settings:
- IP Address (Static): 192.168.0.1
- Use Server: Disabled
- RS485: PC Connection, 115200bps 3. Enter the desired IP address or RS485 settings and save the new settings. 4. Remove the Xpass S2 from the device list and reconnect to the device using the new network settings. TCP/IP Status LED Green LED blinks shortly: Displaying connection status by TCP/IP Red LED blinks shortly: Displaying data transfer stauts by TCP/IP Copyright 2007 Suprema Inc. 8 Xpass S2 Product Dimension
(unit: mm)
< Front View >
< Side View >
< Wall Bracket >
< Extended bracket >
Copyright 2007 Suprema Inc. 9 Xpass S2 Cables and Connectors 1 2 3 4 5 6 7 8 9 Color Color Pin 1 2 3 4 5 6 7 8 9 Pin 10 11 12 13 14 15 16 17 18 Pin Name WGD GND SW GND RS485 GND WGD D0 WGD D1 SW IN0 SW IN1 RS485 TRXP RS485 TRXN Pin Name ETH TXN ETH TXP ETH RXN ETH RXP PWR GND RLY NO RLY COM RLY NC PWR IN Description Wiegand Ground Switch Ground RS485 Ground Wiegand Data 0 Wiegand Data 1 Switch Input 0 Switch Input 1 RS485 TRX+
RS485 TRX-
Description ETH TXN (LAN) ETH TXP (LAN) ETH RXN (LAN) ETH RXP (LAN) Power Ground Relay Normal Open Relay Common Relay Normal Close Power In 10 11121314 15 161718 Copyright 2007 Suprema Inc. 10 Xpass S2 Power Connection Pin 18 14 Pin Name PWR IN Color Red PWR GND Black (White Stripe) Recommended power supply 12VDC 10%, at least 300mA. Comply with standard IEC/EN 60950-1. To share the power with other devices, use a power supply with a higher current rating. 18 14 Xpass S2 Copyright 2007 Suprema Inc. 11 Xpass S2 LAN Connection Ethernet Connection (Connection with HUB) The device can be connected to a network using a regular Ethernet hub. Copyright 2007 Suprema Inc. 12 Xpass S2 LAN Connection (Direct connection with PC) Ethernet Connection (Direct connection with PC) Use a standard CAT-5 cable to connect the device directly to a PC. Copyright 2007 Suprema Inc. 13 Xpass S2 RS485 Connection for Host Communication Pin Pin Name Color 8 9 3 RS485 TRXP Blue (White Stripe) RS485 TRXN Yellow (Black Stripe) RS485 GND White (Black Stripe) 8 9 3 Xpass S2 Xpass S2 Notes Only the devices at the both ends of the bus should be terminated. To enable termination on the RS232-485 converter, refer to the converters manual. Adjust the communication speed as needed. The signal quality vary depending on wiring conditions, and it may be necessary to lower the Baud rate. The GND signal may be omitted if and only if the GND potential difference is less than 5V. Copyright 2007 Suprema Inc. 14 Xpass S2 RS485 Connection for Secure I/O Pin Pin Name Color 8 9 3 RS485 TRXP Blue (White Stripe) RS485 TRXN Yellow (Black Stripe) RS485 GND White (Black Stripe) 8 9 3 8 9 3 Max number of devices Maximum eight (8) devices (including Master) interworks in an RS485 loop. Copyright 2007 Suprema Inc. 15 Xpass S2 Relay Connection Fail safe lock Pin 16 17 Pin Name Color RLY COM Green (White Stripe) RLY NC Orange (White Stripe) 16 17 Xpass S2 Take care of the direction of the diode. Make sure to install the diode near to the door lock. Make sure to use different power supplies for the Xpass S2 and the door lock. Make sure to install the diode at both ends of the circuit as shown in the figure left in order to protect the relay contact from the reverse current that occurs when the door lock works. Copyright 2007 Suprema Inc. 16 Xpass S2 Relay Connection Fail secure lock Pin 15 16 Pin Name Color RLY NO Gray (White Stripe) RLY COM Green (White Stripe) 15 16 Xpass S2 Take care of the direction of the diode. Make sure to install the diode near to the door lock. Make sure to use different power supplies for the Xpass S2 and the door lock. Make sure to install the diode at both ends of the circuit as shown in the figure left in order to protect the relay contact from the reverse current that occurs when the door lock works. Copyright 2007 Suprema Inc. 17 Xpass S2 Relay Connection Automatic Door Pin 15 16 Pin Name Color RLY NO Gray (White Stripe) RLY COM Green (White Stripe) 15 16 Xpass S2 Copyright 2007 Suprema Inc. 18 Xpass S2 Digital Input Connection (Alarm, Emergency S/W) Pin Pin Name 7 2 6 SW IN1 SW GND SW IN0 Color Brown Gray Purple 7 2 6 Xpass S2 Copyright 2007 Suprema Inc. 19 Xpass S2 Digital Input Connection (RTE, Door Sensor) Pin Pin Name 7 2 6 SW IN1 SW GND SW IN0 Color Brown Gray Purple 7 2 6 Xpass S2 Copyright 2007 Suprema Inc. 20 Xpass S2 Wiegand Input/Output Wiegand Input Pin Pin Name 4 5 1 WGD D0 WGD D1 WGD GND Wiegand Output Pin Pin Name 4 5 1 WGD D0 WGD D1 WGD GND Color Green White Black Color Green White Black Xpass S2 4 5 1 4 5 1 Xpass S2 Copyright 2007 Suprema Inc. 21 Xpass S2 Installation of Wall-mount Bracket Fix wall mount bracket on a wall using wall mounting screws Hook Xpass S2 on the wall mount bracket Fix Xpass S2 to the wall mounting bracket using a wall mounting screw Copyright 2007 Suprema Inc. 22 Xpass S2 Installation of Extended Bracket Assemble the extended bracket using screws Mount the extended bracket to the desired location using screws Fix Xpass S2 and the extended bracket using screws Hook Xpass S2 on the extended bracket Copyright 2007 Suprema Inc. 23 Xpass S2 Installation Reference 1 - Standalone Xpass S2 Copyright 2007 Suprema Inc. 24 Xpass S2 Installation Reference 2 Standalone (Secure) Xpass S2 Copyright 2007 Suprema Inc. 25 Xpass S2 Installation Reference 3 Network Copyright 2007 Suprema Inc. 26 Xpass S2 Specification CPU 32-bit Microprocessor (533Mhz) Memory 16MB Flash + 16MB SDRAM RF Card 13.56MHz ISO14443A/B, ISO15693, Mifare, Desfire (CSN), Felica User Capacity 50,000 users Log Capacity 100,000 events Interfaces TCP/IP, RS485, Wiegand In or Out IP Rate Sound LED Input & Output IP65 dust and water protection Multi-tone buzzer Multi-color LED Relay x 1 Switch input x 2 Power 12VDC Operating Temperature
-35C to 65C Dimensions Xpass S2 80 x 120 x 11.4mm (W x H x D) Wall Bracket 68.4 x 110.4mm (W x H) Certificates CE, FCC, MSIP (KCC), IP65, RoHS, REACH, WEEE Copyright 2007 Suprema Inc. 27 Xpass S2 Electrical Specification Min. Avg. Max. Notes Power Voltage (V) Current (mA) Switch Input VIH (V) VIL (V) Pull-up resistance () TTL/Wiegand Output VOH (V) VOL (V) Pull-up resistance () Relay Switching capacity (A) Switching power
(resistive) Switching voltage (V) 10 12
-
-
-
-
-
-
-
-
-
-
Variable Variable 1K 5 0.8 1K
-
-
-
13 300
-
-
-
-
-
Use regulated DC power adaptor only The input ports are pulled up with 1K resistors The outputs ports are open drain type, pulled up with 1K resistors internally 1 0.3 30V DC 125V AC 30W 37.5VA 110 125 DC AC DC AC Copyright 2007 Suprema Inc. 28 Xpass S2 FCC Rules Caution Warning Information to User Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the users authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interface, and
(2) this device must accept any interface received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limit of a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, user and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation; if this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more the following measures:
1. Reorient / Relocate the receiving antenna. 2. Increase the separation between the equipment and receiver. 3. Connect the equipment into an outlet on a circuit difference from that to which the receiver is connected. 4. Consult the dealer or an experienced radio/TV technician for help Copyright 2007 Suprema Inc. 29 16 Tel : 031-783-4510 Fax : 031-783-4503
: sales@suprema.co.kr
: www.suprema.co.kr
: www.biostation.co.kr BioEntry Plus .
.
This product uses the FCC Data API but is not endorsed or certified by the FCC