app
s
|
Applicant Information
|
|
1 2
|
Effective |
2015-05-13
|
1 2
|
2014-09-09
|
1 2
|
Applicant's complete, legal business name |
Peiker acustic GmbH
|
1 2
|
FCC Registration Number (FRN) |
0009359555
|
1 2
|
Physical Address |
Max-Planck-Str. 28-32
|
1 2
|
Friedrichsdorf, N/A 61381
|
1 2
|
Germany
|
|
app
s
|
TCB Information
|
1 2
|
TCB Application Email Address |
g******@cetecom.com
|
1 2
|
t******@cetecom.com
|
1 2
|
TCB Scope |
B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
|
|
app
s
|
FCC ID
|
1 2
|
Grantee Code |
QWY
|
1 2
|
Equipment Product Code |
V1140-100
|
|
app
s
|
Person at the applicant's address to receive grant or for contact
|
1 2
|
Name |
G****** M********
|
1 2
|
Title |
Mr.
|
1 2
|
Telephone Number |
0049 ******** Extension:
|
1 2
|
Fax Number |
0049 ********
|
1 2
|
E-mail |
g******@valeo.com
|
|
app
s
|
Technical Contact
|
|
|
n/a |
|
app
s
|
Non Technical Contact
|
|
|
n/a |
|
app
s
|
Confidentiality (long or short term)
|
1 2 |
Does this application include a request for confidentiality for any portion(s) of the data
contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes |
1 2 | Long-Term Confidentiality
Does this application include a request for confidentiality for any portion(s) of the data
contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes |
1 2 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 11/09/2015 |
1 2 | 03/08/2015 |
|
if no date is supplied, the release date will be set to 45 calendar days past the date of grant.
|
|
|
app
s
|
Cognitive Radio & Software Defined Radio, Class, etc
|
1 2 |
Is this application for software defined/cognitive radio authorization? | No |
1 2 | Equipment Class | PCB - PCS Licensed Transmitter |
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | GSM/GPRS/UMTS/HSDPA/HSUPA Module |
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No |
1 2 | Modular Equipment Type | Limited Single Modular Approval |
1 2 | Purpose / Application is for | Class II permissive change or modification of presently authorized equipment |
1 2 | Original Equipment |
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an
additional equipment authorization? | No |
1 2 | Related Equipment: Is the equipment in this application part of a system
that operates with, or is marketed with, another device that requires an equipment authorization? | No |
1 2 | Grant Comments | Class II Permissive Change. Output power listed is conducted.
This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.
Approval is limited to OEM installation only. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. Grantee must provide installation and operating instructions for complying with FCC multi-transmitter product procedures.
This device is to be used in mobile or fixed applications only. For mobile and fixed operating configurations as documented in this filing the antenna gain, including cable loss, must not exceed 3.57 dBd at 850 MHz, 7.01dBi at 1900 MHz and 13.21dBi at 2600MHz for satisfying RF exposure compliance. Under no conditions may an antenna gain be used that would exceed the ERP and EIRP power limits as specified in Part 22H, 24E and 27.
This device is limited to 3.8V DC supply only. The final product operating with this transmitter must include operating instructions and antenna installation instructions for end-users and installers to satisfy RF exposure compliance requirements. OEM integrators must ensure that the end user has no manual instructions to remove or install this module. The Grantee is responsible for providing the documentation required for modular use. |
1 2 | Output power listed is conducted
This device contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations.
Approval is limited to OEM installation only. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operated in conjunction with any antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.
This device is to be used in mobile or fixed applications only. For mobile and fixed operating configurations, as specified in this filing, the antenna gain, including cable loss, must not exceed 1.47 dBd at 850 MHz, 3.01dBi at 1900 MHz and 9.21 dBi at 2600 MHz for satisfying RF exposure compliance. Under no conditions may an antenna gain be used that would exceed the ERP and EIRP power limits as specified in Part 22H, 24E and 27.
This device limited to 3.8V DC supply only. The final product operating with this transmitter must include operating instructions and antenna installation instructions for end-users and installers to satisfy RF exposure compliance requirements.
OEM integrators must insure that the end user has no manual instructions to remove or install this module. The Grantee is responsible for providing the documentation required for modular use. |
1 2 | Is there an equipment authorization waiver associated with this application? | No |
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No |
|
app
s
|
Test Firm Name and Contact Information
|
1 2
|
Firm Name |
CETECOM GmbH
|
1 2
|
Name |
N****** J********
|
1 2
|
Telephone Number |
+49 2********
|
1 2
|
Fax Number |
+49 2********
|
1 2
|
E-mail |
n******@cetecom.com
|
|