1 |
|
Users Manual | Users Manual | 2.25 MiB | ||||
1 | Cover Letter(s) | |||||||
1 | Test Report | |||||||
1 | External Photos | |||||||
1 | External Photos | |||||||
1 | Internal Photos | |||||||
1 | ID Label/Location Info | |||||||
1 | ID Label/Location Info | |||||||
1 | Cover Letter(s) | |||||||
1 | RF Exposure Info | |||||||
1 | RF Exposure Info | |||||||
1 | Test Setup Photos | |||||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) | |||||||
1 | Cover Letter(s) |
1 | Users Manual | Users Manual | 2.25 MiB |
Mobile WiMAX PCMCIA Card User Guide User Guide Mobile WiMAX PCMCIA Card IEEE 802.16e 2.5/3.5 GHz WiMAX PCMCIA Card WM8931BE WM8921BE E062007-CS-R01 149xxxxxxxxx Compliances Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna Connect the equipment into an outlet on a circuit different from that to which the receiver Increase the separation between the equipment and receiver is connected Consult the dealer or an experienced radio/TV technician for help This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment. IMPORTANT NOTE: FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. To maintain compliance with FCC RF exposure compliance requirements, please follow operation instruction as documented in this manual. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. SAR compliance has been established in typical laptop computer(s) with CardBus slot, and product could be used in typical laptop computer with CardBus slot. Other application like handheld PC or similar device has not been verified and may not compliance with related RF exposure rule and such use shall be prohibited. The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. The firmware setting is not accessible by the end user. i EC Conformance Declaration Marking by the above symbol indicates compliance with the Essential Requirements of the R&TTE Directive of the European Union (1999/5/EC). This equipment meets the following conformance standards:
EN 60950-1 (IEC 60950-1) - Product Safety EN 301 489-1, EN 301 489-4 - EMC requirements for radio equipment EN 50392 - Country specific SAR requirements This device is intended for use in all European Community countries:
ii About This Guide Purpose This guide details the hardware features of the PCMCIA Card, including its physical and performance-related characteristics, and how to install the device and use its configuration software. Audience This guide is for PC users with a working knowledge of computers. You should be familiar with Windows operating system concepts. Conventions The following conventions are used throughout this guide to show information:
Note: Emphasizes important information or calls your attention to related features or instructions. Caution: Alerts you to a potential hazard that could cause loss of data, or damage the system or equipment. Warning: Alerts you to a potential hazard that could cause personal injury. Related Publications The following publication gives basic information on how to install and use the PCMCIA Card:
Quick Start Guide Also, as part of the PCMCIA Cards software, there is online help that describes all configuration related features. Revision History This section summarizes the changes in each revision of this guide. June 2007 Revision This is the first revision of this guide. iii iv Contents Chapter 1: Introduction Features System Requirements Package Checklist Hardware Description Antennas LED Indicators Chapter 2: Installation Chapter 3: Quick Setup Starting the WiMAX Connection Manager Setting a Profile Connecting to a WiMAX Service Chapter 4: Configuration Using WinemaCM The Config Screen Notification Settings The Profile Screen Profile Settings Authentication Settings The Status Screen Connection Info Network Info Program Info Error Log Appendix A: Troubleshooting Diagnosing LED Indicators Network Connection Problems Uninstalling the WinemaCM Software WinemaCM Error IDs 1-1 1-1 1-2 1-2 1-2 1-2 1-3 2-1 3-1 3-1 3-2 3-4 4-1 4-1 4-3 4-4 4-5 4-6 4-7 4-11 4-11 4-12 4-13 4-15 A-1 A-1 A-1 A-2 A-3 v Contents Appendix B: Specifications Appendix C: Configuration File Appendix D: Using Partial Scan Appendix E: Registry Settings B-1 C-1 D-1 E-1 vi Chapter 1: Introduction The Mobile WiMAX PCMCIA Card is a network adapter that enables a notebook PC to connect to a service providers 2.5 or 3.5 GHz mobile WiMAX network. The PCMCIA card plugs directly into a compatible card slot and includes its own driver and configuration software for Windows XP and Windows Vista. The card includes two folding antennas that can be adjusted for best signal reception. When connected to a WiMAX base station, the card is capable of providing a maximum download data rate of 4 Mbps and an upload rate of 1.5 Mbps. Antennas PCMCIA Slot Connector Features Provides a maximum download data rate of 4 Mbps and an upload rate of 1.5 Mbps Easy installation with a user-friendly interface for configuration Working range up to 5 km (3 miles) from base station Scaleable Orthoganal Frequency Division Multiple Access (OFDMA) wireless technology provides a robust, interference-resistant connection Driver support for Windows XP with Service Pack 2 (SP2) and Windows Vista Strong network security with PKMv2, EAP-TLS, and EAP-TTLS support 1-1 Introduction System Requirements Before you install the Wireless PC Card, check your system for the following:
A notebook PC with a PCMCIA Type II slot Windows XP with Service Pack 2 or Windows Vista An account with a WiMAX (IEEE 802.16e) service provider operating a mobile service in the licensed 2.5 and 3.5 GHz bands Package Checklist The Wireless PC Card package includes:
Mobile WiMAX PCMCIA Card Driver and utility CD (includes this User Guide) Quick Start Guide Flyer Safety notice Please inform your dealer if there are any incorrect, missing, or damaged parts. If possible, retain the carton, including the original packing materials, in case there is a need to return the product. Hardware Description The WiMAX PCMCIA Card is fully compliant with the specifications defined in IEEE 802.16e-2005 WAVE 1. It can be installed in any notebook PC with a Type II PCMCIA-compatible slot. The notebook PC must be running Windows XP with Service Pack 2 or Windows Vista. Antennas The WiMAX PCMCIA Card includes two fold-out antennas for wireless communications. The antennas operate in a Maximal-Ratio Combining (MRC) mode when receiving, helping to avoid multipath fading effects. When transmitting, the card only uses one antenna. 1-2 Hardware Description LED Indicators The WiMAX PCMCIA Card includes two status LED indicators. The indicators are visible through the cards black plastic case when it is inserted into a PCMCIA slot. The LEDs are described in the following figure and table. Status LEDs LED Status Description Red Green On On The card is correctly installed in a PCMCIA slot and is receiving power. The card has a valid link with a WiMAX base station. 1-3 Introduction 1-4 Chapter 2: Installation Warning: Network cards are sensitive to static electricity. To protect the card, always touch the metal chassis of your computer or the ground to equalize the static charges, before handling the card. To install the cards driver and utilities for Windows XP or WIndows Vista, the card must be either first inserted in an available PCMCIA slot, or inserted during the set-up procedure. When you first insert the card in a slot, the Windows Found New Hardware dialog box displays. Just click Cancel. Note:
If you encounter problems installing the PCMCIA card, see Troubleshooting on page A-1. 2. To set up the cards Windows driver and utilities, follow these steps:
1. Turn on your notebook and wait until the Windows system has completely started. Load the driver and utility CD that comes with the package. The install program should start automatically. If the install program does not start automatically, open the folder that displays the CDs contents and find the file WinemaCM_Install.exe in the root directory. Double click the file to start the install program. 3. Click Next to continue the installation. 2-1 Installation 4. Select the I accept the terms of the license agreement radio button, then click Next. 5. Select the software and utilities you want to install. Be sure both the WiMAX Client Driver and WiMAX Client Connection Management are selected. Confirm the installation location before clicking Next. 2-2 6. If the following message is displayed, you need to insert the WiMAX card in an available PCMCIA slot on the PC. (Note that this message will not display if you already inserted the card in a slot before starting this set-up procedure.) Find an available PCMCIA slot in your notebook and with the cards 68-pin connector facing the slot, slide the card completely into the slot. When the card is inserted correctly, the green LED on the card turns on (see page 1-3). Click OK to continue the installation. Note:
If the Windows Found New Hardware dialog box displays, click Cancel. 7. When the following warning message concerning Windows Logo testing is displayed, click the Continue Anyway button. 2-3 Installation 8. Wait for the software installation procedure to complete. 9. When the Installation Complete message displays, click Finish. 2-4 Chapter 3: Quick Setup This section shows how to quickly configure the Mobile WiMAX PCMCIA Card and connect to your WiMAX service provider. Starting the WiMAX Connection Manager After the driver and utility software installation, a shortcut icon WinemaCM appears on the WIndows XP or Windows Vista desktop. Double-click on the icon to start the Winema Connection Manager, or find the WinemaCM entry in the Windows Start menu. Double click the icon to start the software. Alternatively, just insert the PCMCIA Card into a slot and the WinemaCM utility starts automatically. The WinemaCM main screen is shown below. 3-1 Quick Setup Setting a Profile Before connecting to your WiMAX service provider, you need to configure a Profile that defines the service providers security settings. There is one default profile named TLS already configured. Follow these steps:
1. From the WinemaCM main screen, click the PROFILE button. The default profile already defined. Click the Add button to define a new profile. The Add button. 3-2 2. From the PROFILE screen, click the Add button. Select the type of security to use as specified by the service provider. Be sure to click the SAVE button to save the profile. Activate the profile to use these settings when connecting to the service provider. 3. In the Add PROFILE screen, define a name to identify the profile, select Auto or Manual Connect, then set the Authentication Mode specified by the service provider. Check the Activate checkbox to use the defined profile, then click the SAVE button. Note: Once you save the profile, the Connection Manager will remember the last configuration. 3-3 Quick Setup 4. The PROFILE screen displays the new profile. Click the Confirm button to close this Window. The new profile is set as the active profile. Click to close the window. Note:
If your service provider supplies a defined profile in a file, use the Import button to import the file instead of configuring the profile details manually. Connecting to a WiMAX Service When you have set up a profile, you are ready to connect to the service providers WiMAX network. Follow these steps:
1. Insert the PCMCIA card into the PCs slot. The WinemaCM software starts automatically. Note:
If WinemaCM does not start automatically, remove the card and reinsert it again. If the problem continues, reinstall WinemaCM or contact your local service support center. 2. From the WinemaCM main screen, click the Connect button.
(Note that this step is not necessary if the active proflie is set to Auto Connect.) 3-4 Click the Connect button to start the connection process. 3. Wait for the status to indicate CONNECTION in the WinemaCM main screen. Click the Connect button to end the connection to the WiMAX service. The status indicates a WiMAX connection and the signal strength. 4. When you have finished your WiMAX network session, click the Connect button to end the session, or just pull the PCMCIA card out of the slot. Note:
If you encounter problems installing the PCMCIA card or connecting to the WiMAX network, see Troubleshooting on page A-1. 3-5 Quick Setup 3-6 Chapter 4: Configuration The WinemaCM software provides all the tools to manage and monitor your WiMAX connection. After initial installation, the software starts automatically every time you insert the Mobile WiMAX PCMCIA Card. The WinemaCM software has four main components:
Main Screen Starts and ends a connection, and displays connection status. Software Configuration Settings for WinemaCM features. Profile Configuration Configures and activates connection profiles. Status Information Current connection details, IP settings, software information, and software upgrade. Using WinemaCM There are several methods of starting the WinemaCM software other than by inserting the Mobile WiMAX PCMCIA Card. From a shortcut icon on the Windows XP or Windows Vista desktop:
Double click the icon to start the software. From an icon on the Windows XP Taskbar:
Click the right mouse button to open a menu of configuration options. Double click the icon to open the application window. 4-1 Configuration The WinemaCM software has two display options, or skins, to choose from. The main screens for the two skins are shown below. Default Skin Connect/Disconnect button Alternate Skin Connect/Disconnect button Other than the display style, there are no function differences between the Default Skin and the Alternate Skin. You can select the skin type from the Config screen. This manual describes the WinemaCM software for the Default Skin. 4-2 The Config Screen The Config Screen From the WinemaCM main screen, click the CONFIG button to open the Config screen. The settings available from this screen control various features of the software. These settings are described below:
Be sure to click the SAVE button to retain any configuration changes. Connection Scheme Sets the software to automatically connect to a WiMAX service or to connect only when the user clicks the Connect button. Note: The Connection Mode set in a profile has a higher priority and overrides the Connection Scheme setting on this screen. Notification Enables notifications to tell the user when the receive signal is poor and if the user moves outside the WiMAX coverage zone. Startup Program Sets the WinemaCM software to start when Windows XP or WIndows Vista starts. Roaming Roaming is not supported by the current software. Skin Selects the display type for the WinemaCM software. Note: Be sure to always click the SAVE button to apply your changes. 4-3 Configuration Notification Settings When Notifications are enabled on the Config screen, the settings for notification events is displayed. The zone notification either makes a sound or displays a pop-up message everytime the user moves into or out of a WiMAX service zone. The signal quality notification either makes a sound or displays a pop-up message everytime the WiMAX signal level falls below the defined threshold. To set the signal quality threshold, click the plus or minus buttons on the Connect button icon. The signal quality threshold is indicated by red colored segments on the signal strength display. Click the plus and minus buttons to set the signal quality threshold. 4-4 The Profile Screen The Profile Screen From the WinemaCM main screen, click the PROFILE button to open the Profile screen. This screen enables one or more connection profiles to be configured, one of which is set as the active profile. Each profle can define different security settings and connection options that can be applied for different service providers. There is one default profile named TLS already configured. The Profile screen is described below. A defined profile set as the active profile to use for connection to a WiMAX service.. Click Add to define a new profile. The Import and Export options enable a configured list of profiles to be imported from or exported to a local file. The Profile List The list of defined profiles. The four columns describe the following properties of the profile:
Activate: Indicates if the profile is set as the active profile to be used to connect to the WiMAX service provider. Connect Mode: Indicates if the profile is set to connect automatically. Authentication: Indicates if some form of security has been configured for the profile. Name: A descriptive name that identifies the profile in the list. Add (+) Adds a new profile to the list. Modify (*) Changes properties for the selected profile in the list. Delete (-) Removes the selected profile from the list. 4-5 Configuration Activate (>) Sets the selected profile as the active profile to be used to connect to the WiMAX service provider. Import Imports a profile list from a file. Export Exports a profile list to a file. Profile Settings From the Profile screen, click on the Add button to create a new profile, or click on the Modify button to change settings for the selected profile. Both the Add and Modify buttons open the Profile Settings window, which is described below. Select the Authentication mode as specified by the WiMAX service provider. Click Save to confirm the profile settings. Make the profile active here or from the Profile screen list. Profile Name A descriptive name that identifies the profile in the list. Authentication Mode The type of security used to connect to the WiMAX service. (See Authentication Settings on page 4-7 for more information.) NONE: No security is used to connect to the WiMAX network. TLS: Transport Layer Security (TLS) uses public key certificates issued by a trusted certificate authority to provide mutual authentication for the connection. A certificate file needs to be stored locally on the client. TTLS_MSCHAPV2: Tunneled Transport Layer Security (TTLS) with the Microsoft Challenge-Handshake Authentication Protocol version 2
(MSCHAPv2) uses a public key certificate on the network side to establish a secure connection, or tunnel, to the client. Authentication is then completed using a user name and password. You must enter the user name and password as specified by the service provider. 4-6 The Profile Screen Auto Connect The profile is used to automatically connect to the WiMAX service. Manual Connect The profile is only used to connect to the WiMAX service when the Connect button is clicked. Activate Sets the profile as the active profile that is used to connect to the WiMAX service. Only one profile can be active at one time. Authentication Settings There are currently two security options available to authenticate and encrypt a connection between a client and the WiMAX network. This section provides more information on setting up these options. TLS Settings If your service provider specifies TLS security for your WiMAX connection, a public key certificate file should be provided for installation on the client. TLS security requires a certificate file to be stored locally on the client. The certificate file can be stored anywhere on the client PC. However, the location of the file must be specified by editing the path entry in the Windows registry. To specify the path in the Windows registry, follow these steps:
1. From the Windows Start menu, select Run, then enter regedit to open the Registry Editor. Find the registry entry HKEY_LOCAL_MACHINE\SOFTWARE\Winema. Locate the entries ClientCertPath, EAPPrivateKeyPath, and RootCertPath. 2. 3. 4-7 Configuration Note: The EAPPrivateKey also needs to be updated. Be sure the EAPrivateKey type and Client certificate type are set to the correct values and that the RootCertPath is specified. 4. Press Enter to edit each entry. Specify the full path to each file, including the file name. Make sure that the files are in the locations specified. Click OK. The entry ClientCertPath specifies the path to the certificate file on the local PC. 5. Locate the entries AnonymousId and PrivateKeyPW and specify the values, then click OK Select ClientCertPath and press Enter to edit the path. 4-8 TTLS_MSCHAPV2 Settings If your service provider specifies TTLS-MSCHAPv2 security for your WiMAX connection, a user name and password should be provided for entry on the client. The Profile Screen TTLS_MSCHAPV2 security requires a user name and password to be entered locally on the client. Be sure to enter the user name and password exactly as specified by the service provider. The password must be confirmed by entering it twice. Then click Save to save the profile. The AnonymousId setting in the Windows registry must also be set for the authentication server. To specify AnonymousId setting in the Windows registry, follow these steps:
1. From the Windows Start menu, select Run, then enter regedit to open the Registry Editor. Find the registry entry HKEY_LOCAL_MACHINE\SOFTWARE\Winema. Locate the entry AnonymousId. 2. 3. 4. Press Enter to edit the entry. Click OK. 4-9 Configuration Select AnonymousId and press Enter to edit the value. Set the value as required for the authentication server. Note: When the Root Certificate Path (RootCertPath) is specified, the root certificate authority (RootCA) is verified. Be sure that the RootCA exists at the specified location. When the RootCertPath is set to NULL, verification is skipped. 4-10 The Status Screen The Status Screen The Status screen provides current connection information. The software information screen also enables updated software to be downloaded. Connection Info The Connection Info screen displays basic information about the WiMAX connection. The displayed items are described below:
Indicates if the connection is operational. Returns to WinemaCM main screen. Connection Status Displays Operational when the WiMAX connection is valid and Not Operational when there is no connection. Start Time The date and time when the connection was established. Total Time The total time since the connection was established. Data The total amount of data in Kbytes that have been transmitted and received. Data Rate The current rate in Kbps at which data is being transmitted and received. 4-11 Configuration Network Info The Network Info screen displays the current Internet Protocol (IP) settings as assigned to the subscriber station by the service provider. The displayed items are described below:
The IP address currently assigned to the subscriber station. Returns to WinemaCM main screen. IP Address The IP address assigned to the subscriber station by the service provider. Valid IP addresses consist of four decimal numbers, 0 to 255, separated by periods. Subnet Mask The IP subnet mask specified by the service provider. The mask identifies the host address bits used for routing to other subnets. Default Gateway The gateway router IP address specified by the service provider. The default gateway is the IP address of the router that is used if the requested destination address is not within the local subnet. Preferred DNS Server IP address of the primary Domain Name server specified by the service provider. A DNS server maps numerical IP addresses to domain names and can be used to identify network hosts by familiar names instead of IP addresses. Alternate DNS Server IP address of a secondary Domain Name server. 4-12 The Status Screen Program Info The Program Info screen displays information about the WinemaCM software and provides a facility to download an upgrade software file. The displayed items are described below:
The current version of the WinemaCM software. Click to download an available upgrade file to update the WinemaCM software version. Returns to WinemaCM main screen. Software Upgrade Click the Upgrade button to download an installation file that upgrades the WinemaCM software. If a new version of software is available, the upgrade file will be downloaded to the PC. The progress of the download is displayed on the screen next to the Upgrade button. Once the upgrade installation file is downloaded, run the file to update the WinemaCM software. Note:
If you need to uninstall the WinemaCM software, see Uninstalling the WinemaCM Software on page A-2. How to Modify the Upgrade Server Location The upgrade server location is specified as a web address in the Windows registry. To change the upgrade server web address in the Windows registry, follow these steps:
1. From the Windows Start menu, select Run, then enter regedit to open the Registry Editor. Find the registry entry HKEY_LOCAL_MACHINE\SOFTWARE\Intel Corporation\WiMAX. Locate the entry Upgrade URL and press Enter to edit the web address. 2. 3. 4-13 Configuration 4-14 Select UpgradeURL and press Enter to edit the web address. The Status Screen Error Log The Error Log screen requires a password to access the displayed information. The error logs can help the service provider troubleshoot problems with the WiMAX conection. Enter the password as specified by the servce provider. The default password is 1234. The displayed items are described below:
Enter the password here. Click the Confirm button to display the Error Log screen. The log error code number. Click to display the error logs. Use the > and < arrows to browse through the logs. Use the Search button to find logs based on error code, event ID, event time, or BSID, Latest Error The error code number of the latest log entry. Recent Error Logs Click the Read button to display the first log entry, then use the arrow buttons to browse through other log entries. Event ID The number that identifies the error log entry. 4-15 Configuration Event Time The time the error log entry ocurred. BSID The identifier number of the WiMAX base station with which the subscriber station is connected. Error Code The error code number of the log entry. Search Enables the user to search for specific log entries based on error code, event ID, event time, or BSID. Select the search key from the pull-down list, specify the log detail to search for, then click the Search button. How to Modify the Error Log Password The Error Log access password is specified in the Windows registry. To change the Error Log access password in the Windows registry, follow these steps:
1. From the Windows Start menu, select Run, then enter regedit to open the Registry Editor. Find the registry entry HKEY_LOCAL_MACHINE\SOFTWARE\Intel Corporation\WiMAX. Locate the entry ErrPagePassword and press Enter to edit the value. Select ErrPagePassword and press Enter to edit the value. 2. 3. 4-16 Appendix A: Troubleshooting Diagnosing LED Indicators Troubleshooting Chart LED Status Red LED is Off Probable Cause The PCMCIA card is not receiving power Action Remove the PCMCIA card and reinsert it in the slot. Be sure the card is securely seated in the slot. Try the card in another PCMCIA slot. If this also fails, test your PC with another card that is known to operate correctly. Check the PCMCIA card and slot connectors for any physical damage. Try the card in another PCs slot that is known to operate correctly. If you cannot resolve the problem, contact your local dealer for assistance. Green LED is Off The PCMCIA card cannot detect a WiMAX base station Verify the area covered by your service provider. Move to a location closer to the WiMAX base station. Network Connection Problems If you cannot access the Internet from the PC, check the following:
Make sure the WinemaCM software and driver is correctly installed on your system. If necessary, try uninstalling and reinstalling the software. If you cannot access the Internet, be sure your WIndows system is correctly configured for TCP/IP. The IP settings should be set to obtain an IP address automatically. You may have moved out of the service area of the WiMAX base station. The WinemaCM main screen should indicate that there is no connection. Call the service provider for service coverage information. The service providers profile may not be configured correctly. Check that the Authentication Mode settings are correct. If you cannot resolve the problem, check the error logs from the WinemaCM Status screen and contact your service provider. See WinemaCM Error IDs on page A-3 for more information. A-1 Troubleshooting Uninstalling the WinemaCM Software If you are having problems with the WiMAX PCMCIA card or the WinemaCM software, you may need to uninstall the card driver and software from the system. Follow these steps:
1. From the Windows Start menu, find the WinemaCM uninstall option. Click to start the uninstall process. The unistall process starts automatically. A-2 2. When the uninstall is complete, click Finish to exit. WinemaCM Error IDs WinemaCM Error IDs The WinemaCM software records error numbers in a log when certain conditions are encountered. From the Status screen you can access the Error Logs by entering a password. The error ID numbers can help the WiMAX service provider troubleshoot problems. The WinemaCM error IDs are listed here for reference. Be sure to take note of displayed error numbers when contacting your service provider for assistance. Error ID Cause 0x11000 Sync failure WinemaCM Error IDs Description MS cannot find the BS. Or there are no valid maps or DCD/UCD from the BS. Ranging procedure with the BS failed. Ranging failure Authentication failure Security authentication failed by supplicant. SBC failure PKM failure Registration failure Timeout Basic capability negotiation with the BS failed. Security authentication failed. Registration with the BS failed. No response from Beceem after timer has timed out. The RSSI is smaller than MIN_RSSI_DBM. The wrong password has been entered. Signal low Wrong password 0x11001 0x11003 0x11004 0x11005 0x11006 0x13002 0x14000 0x18000 A-3 Troubleshooting WinemaCM Error IDs Error ID 0x19000 0x20000 Cause Open device retry Other failure Description The device cannot be opened. Other failures that are not listed. A-4 Appendix B: Specifications Host Interface PCMCIA Type II, 33 MHz, 16-bit interface, 3.3 volt Antennas Built-in dual dipole antennas Transmit: Single antenna Receive: Two antennas using Maximal-Ratio Combining (MRC) Gain: 3.03dBi (2.5GHz), 2.47dBi (2.6GHz), 3.60dBi (2.7GHz) Pattern: Omnidirectional Impedance: 50 Ohm LED Indicators Power, Link/Activity Power Consumption Transmit: 3.3 W maximum Receive: 2.3 W maximum Physical Size 132 x 57.5 x 13.1 mm (5.2 x 2.26 x 0.52 in.) Weight 43.5 g (1.5 oz) Operating Frequency 2.4962.69 GHz and 3.43.6 GHz Support for Full Scan and Partial Scan OFDMA Modulation Scaleable OFDMA employing Time-Division Duplex (TDD) mechanism Deploys both distributed and adjacent subcarrier permutation scheme Fast Fourier Transform (FFT) Size: 512 and 1024 points (depending on bandwidth) Modulation Scheme PRBS subcarrier randomization Contains pilot, preamble, and ranging modulation Modulation and Coding Types Down Link QPSK 1/2 CTC & CC QPSK 3/4 CTC & CC 16 QAM 1/2 CTC & CC 16 QAM 3/4 CTC & CC 64 QAM 1/2 CTC & CC 64 QAM 2/3 CTC & CC 64 QAM 3/4 CTC & CC 64 QAM 5/6 CTC & CC Up Link QPSK 1/2 CTC & CC B-1 Specifications QPSK 3/4 CTC & CC 16 QAM 1/2 CTC & CC 16 QAM 3/4 CTC & CC Bandwidth Allocation System bandwidth: 5 MHz, 7 MHz, or 10 MHz (depending on model) Frame length: 5 msec Maximum Throughput Up link: > 1.5 Mbps Down link: > 4 Mbps Transmit Power Level Maximum Power class less than +23 dBm Receive Sensitivity Preamble power on one channel QPSK 1/2 CTC: -83 dBm 16-QAM 3/4 CTC: -74 dBm 64-QAM 1/2 CTC: -73 dBm Temperature Operating: 0 to 60 C (32 to 140 F) Storage: -40 to 70 C (-40 to 158 F) Humidity 20% to 85% (non-condensing) Emissions Compliance US:CFR 47 Part 15 Class B Europe: EN301 489-1/-4, EN 61000-4-2 Radio Signal Certification US: CFR 47 Part 27, Subpart M, Broadband Radio Service and Educational Broadband Service in the 2500-2690MHz. Europe: EN 301 489-1/-4, EN302 326-1/-2/-3 Specific Absorption Rate (SAR) US: OET Bulletin 65 (Supplement C) Europe: EN 50392 Safety IEC 60950-1 (CB) Standards IEEE 802.16e-2005 WAVE 1 Software Drivers Windows XP SP2 and Windows Vista NDIS 5.0 PnP ETH 802.3 device driver specification WHQL certified B-2 Appendix C: Configuration File The WiMAX PCMCIA card sets some of its initial start-up parameters from a script text file FirmwareCfg.txt. This file can be modified using any text editing tool. After any modifications to the text file, perform these steps:
1. Run the program parsecfg.exe from the directory containing the FirmwareCfg.txt file. This creates a file named macxvi.cfg. 2. You can check the contents of the macxvi.cfg file by running the program readcfg.exe. The following is a listing of the FirmwareCfg.txt file.
# Configuration File Name: FirmwareCfg.txt
# Wibro Config File
# Version 1 - Creation
# Version 2 - Major revision - Created the current structure
# Version 3 - Renaming to HARQ structure to 'General'. HARQ will be
# reintroduced later.
# Version 4 - Added enabling of Tx Power Report from config file
# Version 5 - Added enabling of Random FA selection
# Version 7 - Addded the firmware config option
# version 8 - Added the config option for 8.75/10 MHz bandwidth
# version 9 - Added the config option for ShutDown Timer
# - Removed changes in Version 8
# Version 10 - Merged versions 8 and 9
# Version 11 - EncrSupport & NumOfSAId added
# Version 12 - Radio and PHY Parameters added
# version 13 - options for testing cqich, rang etc
# Dont Change this! Version number used
# to manage the usage of config file Config File Version = 15
# Scanning Parameters
# Make center frequency as x to enable scanning
# Or use (examples): 2336, 2345, 2354, 2367.5, 2385.5 Center Frequency = x Band A Scan = 0 Band B Scan = 0 Band C Scan = 0
# QoS Params Rtps Enable = 0 nRtps Enable = 0 eRtps Enable = 0 Ugs Enable = 0
# HO Params Handoff Enable = 1 HandoffThreshold = 0 HO Reserved1 = 0 C-1 Configuration File HO Reserved2 = 0 HO Reserved3 = 0 HO Reserved4 = 0
# Power Control OL Power Control Enable = 1 OffsetSS = 0 UL AMC - Tx Power Report = 1 PC Reserved2 = 0 PC Reserved3 = 0 PC Reserved4 = 0
# Security Parameters PKMv2 Enable = 1 PKM Reserved1 = 0 PKM Reserved2 = 0 PKM Reserved3 = 0 PKM Reserved4 = 0
# IDLE Mode Parameters IdleMode Enable = 0 Idle Mode timer = 120 # seconds IDLE Reserved1 = 0 IDLE Reserved2 = 0 IDLE Reserved3 = 0 IDLE Reserved4 = 0
# ARQ Parameters ARQ Enable = 1 ArqType = 0 #0, 1, 2, 3 ARQ Reserved1 = 0 ARQ Reserved2 = 0 ARQ Reserved3 = 0 ARQ Reserved4 = 0
# General MAC Parameters MacParameter = 0 # 1- 0xfeff 0- 0xffff
# 0 => UL PRBS encoded to 0.
# 1 => PRBS based on frame number UL PRBS = 1 Random FA Select = 0 Harq Enable = 1 Compressed Map Enable = 1
# Debug Parameters Default DIUC = 2
# (0-15 bits) EEProm offset :512 or (0x200) , (16-31 bits) EEProm Size :
4096(0x1000) EEPROM Start = 0x10000200 Customize = 0x00000200 FirmwareOptions = 0x00 C-2
# Bit 0 - 1 disable linkdown and skip auth during resync
# Bit 0 - 0 enable linkdown notification and authentication during resync
#Should be in Hz i.e. 8750000, 10000000 Bandwidth = 0
# Shutdown Timer in number of frames (5 ms) ShutDown Timer Value = 0x7fffffff EncrSupport = 1
#Number of SAID supported NumOfSAId = 1
# Radio Parameter
# e.g 0x0000ccba
# cc = [15:8] Board Type
# b = [7:4] Band Select {3->2.5 to 2.7G; 4->3.4 to 3.6G }
# a = [3:0] Set to 4 RadioParameter = 0x00000032
# PHY Parameter
# PhyParameter1 e.g. 0xccccbbaa
# cccc = [31:16] 80 * Value of TTG in us
# bb = [15:8] Number of DL symbols
# aa = [7:0] Number of UL symbols
# Special value of 0xFFFFFFFF indicates use of embedded logic PhyParameter1 = 0xFFFFFFFF PhyParameter2 = 0x0 PhyParameter3 = 0x0
#some test options - valid only if eval and test data tranfer are enabled
#in eval mode only; lower 16bits = basic cid for testing;
#then bit 16 is test cqich,bit 17 test init rang; bit 18 test periodic rang and bit 19 is test harq ack/nack m_u32TestOptions = 0
# Max MAC Data Per Frame to be sent in REG-REQ MaxMACDataperDLFrame = 15 MaxMACDataperULFrame = 4 C-3 Configuration File C-4 Appendix D: Using Partial Scan The section shows how to set up the WiMAX PCMCIA Card to use partial scan. Follow these steps:
1. Change the following parameters in the Configuration file:
Center Frequency = 0 PhyParameter2 = 0x1 See Appendix C for details on the Configuration file. Find the registry entry HKEY_LOCAL_MACHINE\SOFTWARE\Intel Corporation\WiMAX and set the PartialScan value to 1. (The value 0 means do not use partial scan.) 2. Set value to 1 to use partial scan. Select PartialScan and press Enter to edit the value. 3. Add the Bandwidths you want to scan to the following registry entries:
HKEY_LOCAL_MACHINE\SOFTWARE\Winema\ParticalScan\BWS1 HKEY_LOCAL_MACHINE\SOFTWARE\Winema\ParticalScan\BWS2 HKEY_LOCAL_MACHINE\SOFTWARE\Winema\ParticalScan\BWS3 D-1 Using Partial Scan HKEY_LOCAL_MACHINE\SOFTWARE\Winema\ParticalScan\BWS4 The maximum number of bandwidths supported is four. If you do not want to scan a bandwdith, set the value to 0. Select BWS1 to BWS4 and press Enter to edit the value. Sets the bandwidth to scan.. 4. Add the center frequencies you want to scan to the following registry entries:
HKEY_LOCAL_MACHINE\SOFTWARE\Winema\PartialScan\
CenterFreqList01 HKEY_LOCAL_MACHINE\SOFTWARE\Winema\PartialScan\
CenterFreqList02
. HKEY_LOCAL_MACHINE\SOFTWARE\Winema\PartialScan\
CenterFreqList20 The maximum number of center frequencies supported is 20. If you do not want to scan a center frequency, set the value to 0. D-2 Select CenterFreqList01 to CenterFreqList20 and press Enter to edit the value. 5. Run WinemaCM. Sets the center frequency to scan. D-3 Using Partial Scan D-4 Appendix E: Registry Settings This section lists the Windows Registry settings for WinemaCM.
[HKEY_LOCAL_MACHINE\SOFTWARE\Intel Corporation\WiMAX]
Name DefaultSkin SkinName Description Type Dword Whether current skin is default skin. (1:default skin, 0:not default skin) String The name of current skin. (default skin:"default", Otherwise:skin name in skin.dat DWord 0: auto connectionn, 1: manual connection ConnectMode Dword NotifyOutZone Dword NotifyOutZoneSound Dword NotifyOutZonePopup NotifySignalBelow Dword NotifySignalBelowSound Dword NotifySignalBelowPopup Dword NotifySignalBelowLevel Dword Dword Always 0. Because Beceem doesn't support Roaming 0: close, 1:start 0: close, 1:start 0: close, 1:start 0: close, 1:start 0: close, 1:start 0: close, 1:start 0 ~ 6 roaming. RoamingType DisplayErrorPage DeviceCheckStr Dword Always 0. Because Beceem doesn't support roaming. 0: hide, 1: display (In current design, we will always show error page.)
"Beceem". The string is used to search the network adapter. Dword String DeviceCheckGUID Binary Used to check whether the device's broadcase event are "GUID_NDIS_LAN_CLASS" class SW_FileName String SW_VersionFileName String Upgrade URL AdapterMatchStr PartialScan RoamingFilter String String Dword String File name of installation package (for example:
WinemaCM_Install_1.1.4.exe) File name of the software verion file (for example:
SW_ver.bin) The URL of upgrade server (for example: http://
upgrade.intel.com)
"Beceem". The string is used to search the network adapter. 0: Do not use partial scan, 1: Use partial scan The strings are used to filter BSIDs searched in partial scan procedure. For example, we want to filter BSIDs with "0x0102" and "0x020304". The value of string will be "0x0102;0x020304."
E-1 Registry Settings
[HKEY_LOCAL_MACHINE\SOFTWARE\Intel Corporation\WiMAX]
Name SyncCenterFreq SyncBandwidth SyncPreambleId SyncBSID Type Dword Dword Dword String Description The center frequency is used to sync-up when we use partial scan procedure The bandwidth is used to sync-up when we use partial scan procedure The preamble ID is used to sync-up when we use partial scan procedure The BSID is used to sync-up when we use partial scan procedure
[HKEY_LOCAL_MACHINE\SOFTWARE\Winema]
Name Username Password ClientCertPath ClientCertType EAPPrivateKeyPath EAPPrivateKeyType PrivateKeyPW AnonymousId RootCertPath Type String Strng String Dword String Dword String String String Description User name for TTLS MS-ChapV2 Password for TTLS MS-ChapV2 Client certificate path Client certificate type. 0:PEM; 1:DER Private key path Private key type. 0:PEM; 1:DER Private key passward Anonymous Identication string CA certificate path
[HKEY_LOCAL_MACHINE\SOFTWARE\Winema\PartialScan]
Name BWS1 ~ BWS4 CenterFreqList01 ~
CenterFreqList20 Type DWord DWord Description Bandwidth specified for partial scan Center frequency specified for partial scan
[HKEY_LOCAL_MACHINE\SOFTWARE\Winema\LoggingInfo\]
Name Software\Winema\
LoggingInfo\
Type Dword Description Output debug messages for supplicant.dll. 1: output debug message 0: close debug messages E-2
[HKEY_LOCAL_MACHINE\SYSTEM\ControlSet002\Services\Tcpip\Parameters]
Name TCPWinodwSize Type Dword Description Setting for TCP window size E-3 Registry Settings E-4 WM8931BE WM8921BE E062007-CS-R01 149xxxxxxxxx
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2007-10-22 | 2508.5 ~ 2685 | TNB - Licensed Non-Broadcast Station Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2007-10-22
|
||||
1 | Applicant's complete, legal business name |
Accton Technology Corp
|
||||
1 | FCC Registration Number (FRN) |
0017693334
|
||||
1 | Physical Address |
No. 1, Creation Rd. III
|
||||
1 |
Hsin Chu 30077, N/A
|
|||||
1 |
Taiwan
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@atcb.com
|
||||
1 | TCB Scope |
B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
HED
|
||||
1 | Equipment Product Code |
WM8920BE
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
A**** W******
|
||||
1 | Title |
Manager
|
||||
1 | Telephone Number |
886-3******** Extension:
|
||||
1 | Fax Number |
886-3********
|
||||
1 |
m******@accton.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | 2.5GHz WiMAX PC Card | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power Output is EIRP. The antenna must not be co-located or operating in conjunction with any other antenna. End-users must be provided with operating instructions for satisfying RF exposure compliance requirements. Highest SAR values are: Body: 0.84W/kg | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch
|
||||
1 | Name |
T****** W******
|
||||
1 | Telephone Number |
886-2********
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
t******@tw.bureauveritas.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 27 | BC | 2508.5 | 2685 | 0.278 | 2.5 ppm | 5M2G9W | |||||||||||||||||||||||||||||||||
1 | 2 | 27 | BC | 2508.5 | 2685 | 0.316 | 2.5 ppm | 9M9G9W |