ADTRAN 424RG 2 POTS/4GigE with 2.4+5.0 Gig WiFi Optical Network Unit jobAid Issue Date: July 2016 Document P/N: 61287781F2-22A CLEI: BVMFG00A_ _ Product P/N: 1287781F2 Documentation for ADTRAN Carrier Networks products is available for viewing and download directly from the ADTRAN Support Community website. Go to: https://supportforums.adtran.com/welcome Registration is required. ADTRAN offers training courses on our products, including customized training and courses taught at our facilities or at customer sites. For inquiries, go to: http://adtran.com/training The following related online documents and resources provide additional information for this product:
Total Access 5000 GPON OLT User Interface Guide Total Access 5000 Series CLI Dictionary Total Access 5000/5006 Engineering Guide Total Access 5000 Series Fiber to the Premises Deployment Guide ADTRAN 400 Series Residential Gateway ONT Basic Configuration Guide 1 2 3 4 2.4 5.0 1 2 B S U SS P W T E S E R 4 E G 3 E G 2 E G 1 E G 1 E N O H P 2 E N O H P S P U V 2 1 DESCRIPTION The ADTRAN 2 POTS/4GigE with 2.4+5.0 Gig WiFi is an Optical Network Unit (424RG ONU) that converts signals being transmitted on optical fiber into electrical signals at a customer location. The illustration at the left displays the front and rear of the 424RG ONU. FEATURES The 424RG ONU supports the following features:
Two POTS (PHONE) Ports Four Ethernet Ports 2.4 GHz and 5.0 GHz WiFi 12 VDC Power Adapter USB Port UPS Connector Reset Button Resetting the ONT
!
All settings will return to Factory Defaults; registration provisioning will be lost. WARNING Front Rear A reset button is available if the 424RG ONU needs to be rebooted. The Reset button is located just below the USB port on the rear of the 424RG ONU. To reset the 424RG ONU, press the RESET button for 5 seconds or longer. Voice Processing POTS uses in-band signaling tones and currents to determine call status (for example, call request). Because POTS allows for the transfer of audio signals below 3.3 kHz, POTS systems are also used for modems that allow data transmission (referred to as dial up connections). Ethernet Interface The 424RG ONU supports data service through four 10/100/1000Base-T Ethernet interfaces via RJ-45 connectors. Power Power is provided by a 12 VDC Power Adapter that is included with the 424RG ONU. The Power Adapter operates from a main power source input of 100 to 240 VAC, 50/60 Hz, with a nominal output of 12 VDC. The total power consumption with WiFi enabled, 4 Ethernet Ports running and both POTS lines off-hook is approximately 22.0 Watts. A connection for an optional un-interruptible power supply (UPS) is also provided. UPS The 424RG ONU provides an optional connection for an UPS. An UPS is a battery backup system designed to continue providing power when the primary power source is lost. Power is supplied to the 424RG ONU by a local power source with battery backup that utilizes the AC power at the customer premises and keeps the battery charged. 1 WiFi The WPS or Wi-Fi Protected Setup function allows you to connect wireless devices without entering the password in the device. This is enabled by simultaneously pressing the button on the left-side of the 424RG ONU and the WPS button on the device which it is going to link to for 5 seconds. The 424RG ONU WiFi 802.11b/g /n/ac supports both 2.4 GHz and 5 GHz. When the WPS button on the rear of the 424RG ONU is turned on (pressed in), the wireless network in your home is secure and encryption is activated. USB There is a USB data connection on the rear of the 424RG ONU that can be used for connection and communications with other computers and electronic devices. INSTALLATION After unpacking the 424RG ONU, inspect it for damage. If damage is noted, file a claim with the carrier and then contact ADTRAN. For more information, refer to the warranty. Installation consists of positioning the 424RG ONU on a desktop and connecting POTS (PHONE), Ethernet, Fiber, and power. Installation Guidelines The following are guidelines for this installation. Read all warnings and cautions before installing or servicing the 424RG ONU. Do not locate the 424RG ONU in direct sunlight or next to any thermal obstructions. Installation Overview To install the 424RG ONU, you will need to complete the following steps:
Step 1: Install the Base and Connect Fiber Step 2: Connect POTS (PHONE) Step 3: Connect Ethernet Step 4: Connect Power Step 5: Connect USB (optional) Required tools Standard technician tools and those listed below are required for installing the 424RG ONU:
Phillips-head screwdriver Two, RJ-11 connectors Four, RJ-45 connectors Wire strippers RJ-11 and RJ-45 crimpers PON power meter with wavelength filtering Fiberscope or videoscope For fiber optic connections, the following is required:
ODC Fiber cleaning tool Installation Steps NOTICE The 424RG ONU must sit upright using the stand provided. DO NOT lay the ONT flat as it may overheat. To install the 424RG ONU, refer to the figures on the first page and complete the following steps. Step 1: Install the Base and Connect Fiber Ensure the 424RG ONU is not located in direct sunlight and is not located next to any thermal obstructions. To attach the 424RG ONU to the base, refer to Figure 1 and complete the following steps:
1. Remove the two screws from the base of the 424RG ONU. 2. Position the 424RG ONU on the base. 3. Using the two screw provided, secure the base to the 424RG ONU. 4. Thread the fiber cable through the opening in the base. If there is excess fiber, carefully wrap it around the Fiber Tray. 5. Remove the plug from the SC/APC Connector and insert the fiber cable. Retain this plug and insert it in the fiber connection when the fiber cable is not connected. This will protect the optical portion of the connection. Figure 2 illustrates the 424RG ONU after the base has been attached. Fiber Tray SC/APC Connector Screw Screw Fiber Opening Figure 1. Attach 424RG ONU to Base and Connect Fiber 1 2 3 4 2.4 5.0 1 2 2 61287781F2-22A Figure 2. 424RG ONU with Base Attached Step 2: Connect POTS (PHONE) If POTS cables are not available, use Figure 3 and the following procedure to create the POTS cables:
1. Trim the insulation for the subscriber POTS cables. 2. Refer to the illustration below and connect the twisted-pair Tip
(green) and Ring (Red) to the RJ-11 connector using an RJ-11 crimper. 3. Insert the RJ-11 connector in the appropriate PHONE 1 or PHONE 2 jack. 1 2 3 4 1 = Not Connected 2 = Tip 3 = Ring 4 = Not connected Figure 3. POTS (PHONE) Connection Step 3: Connect Ethernet The 424RG ONU supports four 1 Gigabit (10/100/1000Base-T) connections (GE 1 to GE 4). If Ethernet cables are not available, use the following procedure and table to create the Ethernet cables:
1. Trim the insulation for the subscriber Ethernet cable. 2. Connect the wires per the following table using an RJ-45 Crimper. Ethernet RJ-45 Pin-out Pin 1 Name TRD0+
Description Transmit/Receive Positive 2 3 4 5 6 7 8 TRD0-
TRD1+
TRD2+
TRD2-
TRD1-
TRD3+
TRD3-
Transmit/Receive Negative Transmit/Receive Positive Transmit/Receive Positive Transmit/Receive Negative Transmit/Receive Negative Transmit/Receive Positive Transmit/Receive Negative Color Code White/
Orange Orange White/Green Blue White/Blue Green White/Brown Brown The 424RG ONU can typically use an un-interruptible power supply
(UPS) if desired. Power is supplied to the 424RG ONU by a local power source with battery backup that utilizes the AC power at the customer premises. The UPS powers the 424RG ONU and functions as a battery backup unit (BBU) supplying continuous 12 VDC. Refer to the installation material that is provided with the UPS when installing the BBU. UPS Connector Connect the UPS to the 8-pin MOLEX connector labeled UPS located on the rear of the SFU ONT chassis. Figure 4 illustrates the MOLEX connector on the rear of the ONT. Figure 4. 8-Pin Molex Connector The UPS Power/Alarm Connections Table below defines each pin on the connector. NOTE ADTRAN offers a UPS Cable assembly (P/N 1287402G1) for this connector. UPS Power/Alarm Table The following table indicates which pin is associated with each alarm provided through a UPS connection. Pin-Out 1 2 3 4 5 6 7 8 Description Power Input (+12 VDC) UPS Status - On Battery UPS Status - Battery Missing Signal Return Power 12 V Return UPS Status - Replace Battery UPS Status - Low Battery No Connection Alarm
-
1 2
-
-
3 4
-
3. Insert the CAT 6 rated cable in the appropriate GE 1 through GE 4 ports on the rear of the 424RG ONU. Step 4: Connect Power NOTE If an UPS is being used and is disconnected, the 424RG ONU is not protected from power outages, and will send a Battery Missing alarm to the OLT. Plug the supplied 12 VDC Power Adapter into the 12V connection on the rear of the chassis. Connect the AC plug to a standard 120 VAC outlet. Step 5: Connect USB (optional) NOTICE DO NOT connect the Power Adapter and an UPS at the same time as this will cause damage to the 424RG ONU. The ONT can be powered by either power source, but not both simultaneously. 61287781F2-22A 3 LED STATUS The LEDs are located beneath the plastic housing and are only visible after power has been applied. The following table provides the LED status during normal operations. Label POWER Status Off Green Indication AC or battery off No Failure REGISTRATION ID Registration ID is performed by Serial Number Activation. This occurs when the 424RG ONU is Discovered by the OLT. NOTE If AOE Auto Upgrade is active, a new 424RG ONU installation will be detected and a fast blinking FIBER LED will indicate a new software download has commenced. This may take 5 - 10 minutes to complete. FIBER Off INTERNET GE 1-4 USB 2.4GHZ 5GHZ PHONE 1-2 WPS 2 Green Green Flashing Fast Off Green 2 2 2 2 2 2 Off Green Green Flashing Fast Off Green Green Flashing Fast Off Green Green Flashing Fast Off Green Green Flashing Fast Off Green Green Flashing Slow Off Green Green Flashing Fast No connection to the OLT, open fiber, failure at the ONT, or power is Off Signal present and is within operating range Ranging in Progress No IP address configured on WAN Interface, or Power is Off WAN Interface is configured with IP address Link is down or not equipped Link is up Data is being sent or received Power Off or no device con-
nected Device connected Data is being sent or received Power is Off, or Wireless 2.4GHz is Disabled Wireless 2.4GHz is Enabled Data is being sent or received on 2.4GHz Power is Off, or Wireless 5GHz is Disabled Wireless 5GHz is Enabled Data is being sent or received on 5GHz Unequipped or on-hook and not ringing Line is off-hook Line in ringing state Power Off or WPS is Disabled WPS is Enabled WPS push button pressed and device is ready to accept con-
nection SPECIFICATIONS Electrical Voltage: 12 Volts typical Minimum Voltage: 10 Volts Maximum Voltage: 13.9 Volts Power Consumption: Typical 25.0 watts Physical 10.8 inches high (27.4 centimeters) 7.4 inches deep (18.8 centimeters) 3.2 inches wide (8.1 centimeters) Weight: 1 pounds (0.45 kilograms) Environmental Operational Temperature: 32F to +104F (0C to +40C) Storage Temperature: 4F to 122F (20C to +50C) Relative Humidity: 90%, noncondensing Optical TX min power: +0.5 dBm TX max power: +5.0 dBm RSSI max sensitivity: 27.0 dBm R.0X overload: 8.0 dBm TX wavelength: 1310 nm typical RX wavelength: 1490 nm typical MAINTENANCE The 424RG ONU does not require routine hardware maintenance for normal operation. ADTRAN does not recommend that repairs be attempted in the field. Repair services may be obtained by returning the defective unit to ADTRAN. Refer to the warranty for further information. Field support for software is provided through upgrade facilities. SAFETY AND REGULATORY COMPLIANCE Refer to the Safety and Regulatory Compliance Notice for this product (P/N 61287781F2-17) for detailed safety and regulatory information. Consultez l'avis sur la scurit et la conformit la rglementation pour ce produit (61287781F2-17) pour obtenir des renseignements dtaills sur la scurit et la rglementation. Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found online at www.adtran.com/warranty. Trademarks: Brand names and product names included in this document are trademarks, registered trademarks, or trade names of their respective holders. 2016 ADTRAN, Inc. All Rights Reserved. C A U T I O N C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663 From outside the U.S. +1 256.963.8716 PRICING AND AVAILABILITY 1.800.827.0807