Access Control Systems / Wander monitoring INSTRUCTIONS FOR USE ACCESS CONTROL SYSTEM PE3LR WANDER MONITORING AD-CARE Access Control Systems / Wander monitoring SUMMARY PE3LR / AD-CARE SYSTEM OVERVIEW WORKING PRINCIPLE P. 1 SYSTEM COMPONENTS - READERS/CONTROLLERS/SOFTWARE SYSTEM COMPONENTS - TAGS / CARDS / AD-CARE-W WRIST P. 2 P. 4 PE3LR / AD-CARE STAND ALONE SYSTEM DETAILS P. 6 Technical specifications PE3LR-C / AD-CARE Stand-alone controller Wiring information PE3LR-C / AD-CARE Stand-alone controller Technical specifications PE3LR-E external reader POSITIONNING CONTROLLER / EXTERNAL ANTENNA Single / Dual reader configuration Specific recommendations / configurations P. 6 P. 7 P.10 P. 11 FCC - 15.21 NOTE:
The user manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. (PE3LR-C / PE3LR-
T/ PE3LR-TCH / AD-CARE-W) NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USERS AUTHORITY TO OPERATE THE EQUIPMENT. ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 2 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898 Access Control Systems / Wander monitoring PE3LR / AD-CARE SYSTEM OVERVIEW ADVEEZ TECHNOLOGY ADVANTAGES 100% Hands Free Access: accurate, long range, compatible with ADVEEZ & existing OEM access control systems The ADVEEZ PE3LR is a hands-free access control system that combines precision, long range and 3D detection. It offers very con-
venient and efficient access control via the ADVEEZ PE3RL-T card/tag which can be carried in a bag or pocket and still be quickly identified. The PE3LR is ideal for upgrading traditional key pad and card swipe systems or applications where hands-free access is required including: clean rooms, hospitals, parking, entry automation for disabled persons, etc. PE3LR system components are compact, robust and easy to install. By creating precise detection zones, the ADVEEZ system avoids misdetection, which is the main drawback of existing systems. All ADVEEZ Readers supports 125 kHz, in addition to Adveez hands-free tags. The PE3LR system is also compatible with all types of electronic locks (magnetic locks, electro-mechanic locks, motorized locks, etc.) and automatic devices (motorized doors). It can be connected to existing supervised access control systems as well. AD-CARE WANDER MONITORING SYSTEM ADVEEZ AD-CARE wander monitoring system is a variant of PE3LR system which takes advantage of the precise & robust ADVEEZ detection. AD-CARE controllers can detect people wearing the AD-CARE-W wrist within a distance of 1 m up to 4 m. It can then send an alarm, lock the access to be monitored, send and alarm locally or remotely to pagers and access control net-
work controllers. Hands free tags can be used for passing through monitored accesses with patients & clearing alarms automatic DETECTION PRINCIPLE PE3LR / AD-CARE ally. Main controller includes reading function . External antenna can extend main controller detection zone. Easy configuration per software of detection zones, enrolling of cards, wander management wrist. SIMPLE, FLEXIBLE, AND RELIABLE SOLUTION ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 1 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898 Access Control Systems / Wander monitoring PE3LR / AD-CARE SYSTEM OVERVIEW INSTALLATION OVERWIEW Request to Exit button input (2 wires) Magnetic Lock Door strike Relay output 1
(2 wires) DATA INTERFACE OVERWIEW Door contact input
(2 wires) PE3LR-C / AD-CARE-C main controller PE3LR-E External antenna wiring (passive reader)
(6 wires) Additional contact Relay output 2
(2 wires) Alarm, Display.. WIEGAND OUTPUT For connection to access controllers
(2 wires / Data0-Data1) Serial RS485 OUTPUT:
Connection to ADVEEZ network controllers Connection to Nurse call systems (AD-CARE version)
(2 wires / Data0-Data1) Local connection to PC for stand alone mode configuration ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 2 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898 ands-free Access Control System PE3LR Access Control Systems / Wander monitoring SYSTEM COMPONENTS PE3LR / AD-CARE SYSTEM COMPONENTS PE3LR/AD-CARE controller & PE3LR external antennaFCC ID: R8T-PE3LR-C INTERNAL READERPE3LR-C / AD-CARE STAND-ALONE CONTROLLER Hands-free Access Control 1 access point 1024 cards in stand-alone version (64000 users in network version) Program cards directly with Master Card (PE3LR-MC) or management software via PC USB Cable The Internal Reader function PE3LR-C Door Controller allows:
-Setting hands-free access or proximity (125 kHz) control in the secured zone on the external side without adding an additional Reader
-Enrolling badges directly via the controller
-Sensing movement direction between PE3LR-C internal Reader and PE3LR-E external Reader
-Connecting to ADVEEZ supervised access control system in a wired RS485 mode (Ref. P3LR-C-MC) or wire-
less (ref. PE3LR-C-WL)
-connecting to existing third party access control systems via Wiegand output
-connecting to nurse call systems (AD-CARE version) EXTERNAL READER / ANTENNA PE3LR-E
- Waterproof and robust for outdoor installation
- additional Hands Free / detection zone
- ADVEEZ PE3LR-T Hands-free tag reading
- 125 KHz EM4100, 4200, 4450 Marin card reading This device (FCC ID : R8T-PE3LR-C) complies with part 15 of the FCC Rules. Operation is subject to the following two condi-
tions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation WARNING STATEMENT FOR MODULE:
Because of the power level and grant conditions of the Zig-Bee module, the 20cm separation distance warning statement is need-
ed. Please see below.: The antenna(s) used for this transmitter must be installed to provide a minimum separation distance of 20cm, and must not be co-located or operating in conjunction with any other antenna or transmitter. FULL FUNCTION BENEFIT FROM PE3LR / AD-CARE WILL BE OBTAINED WITH FOLLOWING SOFTWARE STAND ALONE CONFIGURATION SOFTWARE (not described in present document) PE3LR-PLG (PE3LR ACCESS CONTROL) PE3LR-PLG-WANDER-MONITORING (AD-CARE)
- Enroll & Delete cards
- Download logged events
- Configure access control (relay output)
- Enroll & Delete cards / wrist
- Download logged events
- Configure access control (relay output) & alarm clear-
ORGANEEZ SUPERVISED ACCESS CONTROL MANAGEMENT (not described in present doc.) 64000 event history / 10000 users / 128 readers / TCP-IP-R-485-Radio network ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 3 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898 Access Control Systems / Wander monitoring SYSTEM COMPONENTS PE3LR / AD-CARE SYSTEM COMPONENTSCREDENTIALS HANDS-FREE TAG PE3LR-T (FCC-ID: R8T-PE3LR-T*) CR2032 battery life: 2,000,000 hands-free tag activations Tag dimensions 74 mm/ 34 mm / 10 mm Hands-free badge color options: Black (ref: RAL9004), Grey (ref:
RAL9006) - Red Master Tag PE3LR-T-MC enables programming tags Inserting CR2032 battery Declip tag cap and insert battery in holder This device (FCC ID : R8T-PERL3-T) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation HANDS-FREE CARD HOLDER PE3LR-TCH (FCC-ID: R8T-PE3LR-TCH*) Carries standard swipe or RFID proximity ISO cards CR2032 battery life: 2,000,000 hands-free tag activations Combines hands-free access system with existing swipe and magnetic card TORX SCREW DIAM. 2.5MM 4 Dimensions: 86 mm / 54 mm / 0.76 mm Black (ref: RAL9004) This device (FCC ID : R8T-PERL3-TCH) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any inter-
ference received, including interference that may cause undesired operation Inserting CR2032 battery:
Remove cover (4 screws -torx) and insert battery in holder CAUTION:
Both hands free PE3LR-T & PE3LR-TCH work in proximity mode for access as well as for programming. Tags must be approached to PE3LR-C, AD-CARE-C & PE3LR-E ADVEEZ logo. Once the tag has been programmed on the system , battery must be inserted or removed & re-inserted in order ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 4 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898 Access Control Systems / Wander monitoring SYSTEM COMPONENTS PE3LR / AD-CARE SYSTEM COMPONENTSCREDENTIALS AD-CARE-W WANDER MONITORING WRIST (FCC-ID: R8T-AD-CARE-W*) CR1632 battery life: 2,000,000 wander monitoring activations Housing dimensions 52 mm/ 40 mm / 9,5 mm White anti-batcterial plastic housing 1 way white wrist material: Vinyl Wrist width: 16 mm TORX SCREW DIAM. 2.5MM 4 Inserting CR1632 battery:
Remove cover (4 screws -torx), remove printed circuit board from housing and insert battery in holder This device (FCC ID: R8T-AD-CARE-W) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference re-
ceived, including interference that may cause undesired operation CAUTION:
AD-CARE-W wrist works in proximity mode for access as well as for programming. Tags must be approached to PE3LR-C, AD-CARE-C & PE3LR-E ADVEEZ logo. Once AD-CARE-W wrist has been programmed on the system , battery must be inserted or removed & re-
inserted in order to initiate tag rights. FCC - 15.21 NOTE:
The user manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. (PE3LR-C / PE3LR-
T/ PE3LR-TCH / AD-CARE-W) NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USERS AUTHORITY TO OPERATE THE EQUIPMENT. ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 5 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898 Access Control Systems / Wander monitoring PE3LR / AD-CARE Controller specifications / mounting instructions PE3LR-C / AD-CARE-C controller (FCC-ID : R8T-PE3LR-C*) Stand alone door controller PE3LR-C / AD-CARE (health care variant) Programming via PC 2 frequency RF system Both ADVEEZ hands Free + 125 kHz EM cards supported 12V/24V power supply with no configuration needed 200 mA average current draw / 1A peak Operating temperature : -20C / +70C Protection class: IP54 Weight: 0.200 kg 10000 users 64000 event history RS485 networkradio network option (PE3LR-C-WL) 2 relays / 1 door contact switch Mounting & Dimensions Mounting (caution: avoid mounting close to 125kHz proximity card readers):
1) Fit all cables with terminal appropriate terminal blocks according wiring details in page 3 2) Mount the back cover on the wall (4 screws) and let the Cables fitted with the terminal blocks go through the back cover 3) Connect all the terminal blocks on the printed circuit board according to wiring diagram page 3. 4) Mount and screw the front cover unit on the back cover 4 screws - 460 mm 4 S6 wall plugs This device (FCC ID : R8T-PE3LR-C) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation WARNING STATEMENT FOR MODULE:
Because of the power level and grant conditions of the Zig-Bee module, the 20cm separation distance warning statement is need-
ed. Please see below.: The antenna(s) used for this transmitter must be installed to provide a minimum separation distance of 20cm, and must not be co-located or operating in conjunction with any other antenna or transmitter. ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 6 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898 Access Control Systems / Wander monitoring WIRING INFORMATIONTERMINAL BLOCK DETAILS PE3LR/AD-CARE Controller B2 1 B1 B3 Reset Button 1 B4 1 U17 Connector for USB-PC communication Jumper configuration Jumper OFF Jumper ON J3 OFF + J4 OFF single internal antenna activation J3 ON + J4 OFF Both internal & external antennas activated J3 OFF + J4 ON Single external antenna activation J3 ON + J4 ON Internal & external readers activatedfiltering of misdetec-
tions in secured zone activated J2 ON: long rangeinternal antenna J6 ON: activation buzzer J1 ON: long range activation external J7 ON: activation de la LED antenna interne J5 ON: Red LED activated Block 1 BLUE 4 Pins POWER SUPPLY RTE button Pin 1: 12V/24V Pin 2: GROUND Pin 3: Request To Exit button +
Pin 4: Request To Exit button -
Block 2 GREY- 6 Pins 2 Relay / Door contact Pin 1: Relay NO2 Pin 2: Relay - C2 Pin 3: Relay NC2 Pin 1: Relay NO1 Pin 2: Relay- C1 Pin 3: Relay NC1 Block 3 GREY - 6 contacts - COMMUNICATION Pin 1: RS485-B Pin 2: RS485-A Pin 3: GROUND Pin 4: Door Contact Pin 5: DATA 1 - Wiegand Pin 6: DATA 0 - Wiegand Block 4 GREY 6 contacts External Antenna Pin 1: Tx1 Pin 2: Tx2 Pin 3: LED Green Pin 4: LED red Pin 5: GROUND Pin 6: RX U17 : Inline switches for indexing controllers ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 7 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898 Access Control Systems / Wander monitoring Wiring information - PE3LR/AD-CARE interface to access CTL & nurse call BLOCK 3 : NURSE CALL (ESPA4.4.4 output or POCSAG TEXT or ASCII) Pin 1: RS485-B Pin 2: RS485-A Pin 3: GROUND Contacteur de porte Pin 4: DATA 1 - Wiegand Access controldoor controllers Pin 5: DATA 0 - Wiegand Access controldoor controllers RS485-RS232 TX Converter RX 446 MHz Protocole configuration depending on device downstream of AD-CARE controller :
Select tick box ESPA4.4.4 orPOCSAG TEXT or ASCII raw data depending on device used Monitored access can be named Pager Adress / groups can be selected for ESPA communication mode. ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 8 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898 Access Control Systems / Wander monitoring WIRING INFORMATIONPE3LR / AD-CARELOCKING DEVICES / RELAYS / POWER SUPPLY Block 2 GREY - 6 contacts 2 Relay / ContactsDoor strike configuration (NO) Pin 1: Relay NO2 Pin 2: Relay - C2 Pin 3: Relay NC2 Pin 1: Relay NO1 Pin 2: Relay - C1 Pin 3: Relay NC1
+ door strike 12V/+Alim 0V/-PWR IntrusionAlarm wiring depends on device Manufaturer / type Block 2 GREY - 6 contacts 2 Relay / ContactsMagnetic Lock configuration (NCpermanently supplied) Pin 1: Relay NO2 Pin 2: Relay - C2 Pin 3: Relay NC2 Pin 1: Relay NO1 Pin 2: Relay - C1 Pin 3: Relay NC1 12V/+PWR
+ magnetic lock 0V/-PWR IntrusionAlarm wiring depends on device Manufaturer / type Block 1 BLUE 4 contacts POWER SUPPLY RTE Pin 1: 12V/24V Pin 2: GROUND Pin 3: RTE Button +
Pin 4: RTE Button -
+ ALIM
- ALIM
ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 9 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898 Access Control Systems / Wander monitoring WIRING INFORMATION PE3LR / AD-CARE PE3LR-E EXTERNAL READER (FCC-ID : R8T-PE3LR-C*) Reading of hands free card PE3LR-T with high reading distance accuracy PE3LR-E enables extending detection zone by connecting it to PE3LR-C Mounting on standard wall box 2 screws (minimum distance from a metal surface: 5 cm)
(caution: avoid mounting close to 125kHz proximity card readers) PE3LR-C-MC 12V / 24V Connection via removable terminal block 2 colors (red/green) LED actuation Multi technology antenna Removable terminal block details PE3LR-E Block 1 Grey - 6 ways Internal Reader
*Internal and External door control PIN# 1: green LED PIN# 2: red LED PIN# 3: Ground LED PIN# 4: Tx1 PIN# 5: Tx2 PIN# 6: Rx1 Mounting External reader backside view / terminal block pin ordering details 2 screws 4 mm 60 mm on a standard recessed conduit box 67 mm diameter and 40 mm depth This device (FCC ID : R8T-PE3LR-C) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 10 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898 Access Control Systems / Wander monitoring Single-reader configuration - PE3LR-C / AD-CARE The access control can work with the single door controller/internal reader. The following drawing shows the detection zone PE3LR-C is positioned on entry on the inside wall or on the outside wall depending on wall metal content inside the ring. In this configuration, the access control works in both direction (internal and external). The door controller / internal reader PE3LR-C must be placed in the secured zone to prevent any risk of attack towards controller. There is then no outside indication of identification Zone to be secured Bi-reader configuration : external anti-vandal device Secured Zone/Outside view PE3LR-E Inside view PE3LR-C External Reader Internal Reader/ Door controller Door controller Installation External Reader Installation Internal Reader/ Door controller Door contact switch Door reader Electric lock Cable/External reader ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 11 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898 Access Control Systems / Wander monitoring PE3LR-C controller Located in the zone to be secured PE3LR-E located on the entrance ZONE 1 ZONE 2 Sensing movement direction via PE3LR-C door controller Drawing below shows 2 separated zones, each being fitted with 1 external reader close to entrance and 1 controller/internal reader inside. Door controllers jumper J1 is activated so that reader function gets activated. Door controllers jumper J4 is deactivated so that access control is not active on exit. If card bearer wants to enter zone 1 with authorized card, his card is detected while Filtering misdetections inside the secured zone Inhibiting the detection in a given area Door controllers dipswitch J1 is activated so that reading function is active. A switch contact of exit request is connected to the Block 4. The dipswitch J4 of door controller is deactivated to disable the access control in exit. If card bearer being situated in zone 1 with authorized card wishes to pass the door
(controlled door) of the zone without going out, his card is detected in the intersection between green and orange detection zones. The controller/internal reader will then identify the passage of PE3LR-E reader in the internal detection zone avoiding to unlock the access. Positioning readers of two different accesses Two different detection ranges can be configured on PE3LR-C The detection range in short distance (dipswitch J1 or J2 deactivated) is 1.5 m. The detection range in long distance (dipswitch J1 or J2 activated) is 3 m. ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 12 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898 Hands-free access control system PE3LR ADVEEZ SUPERVISED SYSTEM : connecting PE3LR & AD-CARE controllers TECHNICAL SPECIFICATIONS PE3LR-NT NETWORK CONTROL Manage Access authorization for all card types Control 128 doors in Radio / RJ-45 / RS-485 mode In the radio mode, each Controller PE3LR-C-NT is a network access point Central access control management: users, credentials, readers, etc. PE3LR-NT Event history recording - 64000 per access controller Administrative PC Connecting the Network controller to the PC via USB cable
*ADVEEZ Connection
*Radio / RJ-45/ RS-485 Transmission
*Door control function RS-485 / USB PE3LR-NT Radio / RJ-45 / RS-485 PE3LR-C-NT 12V / 24V PE3LR-E ACCESS CONTROL SOFTWARE
-Program / Delete credentials, users, readers
-Manage Administrators rights
-Manage time intervals, schedules and holidays
-Configure Hands-free access control:
Relay activation duration Detection distance Software supplied on a USB drive with a USB cable and installation guide ADD-INS-PE3LR-CARE-ENG-31 ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163 31027 Toulouse Cedex 3 FRANCE
+33(0)582082193 13 www.adveez.com Subject to change without notice email: contact@adveez.com Phoenix, AZ USA
+1 602-549-7898