Home Energy Meter View the expanded manual:
http://aeotec.com/support Model: ZW095-A Aeotec by Aeon Labs Home Energy Meter. Diagram of USA Version(2 Phases):
In 230 volt countries with a 3 phases and 3 wires installation;
Diagram of EU/AU Version(3 Phases,3 Wires):
You hear a lot about energy use these days. About how if you reduce the amount of energy you use youll both save money and the environment. But saving money by using less electricity is only possible if you understand when and how you are using it. Thats what Aeotecs Home Energy Meters provide you with: understanding, for your whole home. Installed in an electricity box, your new energy meter will monitor the total amount of electricity your home uses with accuracy and speed. Using a wireless Z-Wave connection, itll then feed the data it records back to your smart homes gateway. In near real-time youll have a full understanding of how much electricity you use and when you use it. Familiarise yourself with your Home Energy Meter. Your Home Energy Meter from Aeotec by Aeon Labs is comprised of two parts: the Main Body and Clamps. Once installed, the meter will sit near your homes main circuit box, while the clamps are attached to it. RedLED Action Button AC Input Wire Quick start. Clamps NOTE : If you cannot find a Socket , ask your electrician for help on wiring. In 230 volt countries with a 3 phases and 4 wires installation;
Diagram of EU/AU Version(3 Phases,4 Wires):
The installation of your Home Energy Meter has two major parts: the installation of it into your homes main circuit box and the syncing of it to your Z-Wave network. What follows are the instructions for both parts. Please note that only a licensed electrician, with knowledge and understanding of electrical systems and electrical safety, should perform the electrical installation of your meter into your homes circuit box. The syncing of your Home Energy Meter with your Z-Wave network can be performed by you. Installing the meter into a circuit box. In 230 volt countries with a 1 phase installation;
Diagram of EU/AU Version(1 Phase):
Important:Only a licensed electrician should perform these steps. Important: The circuit box's main breaker should be turned off to perform these installation steps. The following diagrams highlight how the Home Energy Meter should be installed dependent on the region you are in;
In the United States, it is always a 2-phase installation;
To perform the electrical installation for your Home Energy Meter (HEM), utilise the previous images to determine the phase version of the HEM and to also illustrate the following steps 3 through 7. 1. Turn off the homes main electricity breaker and open the main circuit box panel. 2. Connect each clamp to the HEM using the clamp connector. Screw them tight. 3. Clip the clamps of the HEM around the incoming electricity cables that connect to the main circuit breaker. 4. Connect AC Wire to the meter using the AC Wire Connector. 5. Insert the HEMs neutral AC Wire into the main circuit breakers neutral bus terminal. 6. Insert the HEMs live AC Wire into the main circuit breakers live terminal. 7. Replace the main circuit box panel. 8. Turn the main breaker back on. It is now time to permanently affix the Home Energy Meter to a surface. Within each meter is a low-frequency radio antenna thats used for wireless communication. This must be taken into consideration when selecting a final location for the meter. Thick concrete walls, metals, or motor devices will affect the signal strength of the controller and the meter. If the homes circuit box is made of a metal, it is recommended that the Main Body of the meter be installed outside of the circuit box. Placing the meter inside the circuit box could degrade the quality of the radio signal and negatively impact its wireless range. To assist with such an installation, each meter is weatherised to the IP44 international standard. This makes it resistant to rain and snow when installed vertically. To place the Home Energy Meter (HEM):
1. Remove the backing plate from the back of the HEM. 2. Affix the plate to the selected wall space using the provided screws. The plate should be installed vertically and aligned so that the wires of the HEM are at the bottom. 3. Attach the HEM to the backing plate. Linking your meter to an existing Z-Wave network. The electrical installation of your Home Energy Meter (HEM) is now complete. You must now wirelessly link it to your Z-Wave network. 1. Put your primary Z-Wave controller, usually a gateway or hub, into inclusion mode. If you are not sure how to do this, please refer to your controllers user manual. 2. Press the Action Button on your HEM. If it has been successfully linked to your network, its LED will remain illuminated. If the linking was unsuccessful, your HEMs LED will continue to blink. The installation of your Home Energy Meter is now complete.The next step is to set up your Home Energy Meter within the interface of your primary Z-Wave controller. This will allow you to visualise and utilise the energy consumption data that your meter collects. Your Home Energy Meter can report wattage energy usage or KWH energy usage to your primary controller. As each controller is different, please refer to your controllers user manual for further information on monitoring and visualising this data.The specific Z-Wave commands supporting energy monitoring are the Meter Command Classes. Advanced functions. Removing your meter from a Z-Wave network. Your Home Energy Meter (HEM) can be removed from your Z-Wave network at any time. You'll need to use your Z-Wave networks primary to do this.. 1. Put your main controller into its device removal mode. If you are unsure how to do this, please refer to your controllers user manual. 2. Press the Action Button on your HEM. If it has been successfully removed from your network, its LED will blink. If the removal was unsuccessful, its LED will be solid and it will be then repeated again. Resetting your Home Energy Meter. Your Home Energy Meter can be reset to default factory settings with ease. 1. Press and hold the Action Button for 10 seconds. 2. If successful, the LED on the HEM should begin to blink slowly. Associating your Home Energy Meter to Report Automatically. Your Home Energy Meter can send Wattage and KWH usage reports to associated devices. To enable this, please refer to your controllers manual on how to configure settings on Z-Wave devices linked to your controller. Initially, the meter is set up to report Watt and KWH reports. Some gateways/controllers will automatically configure devices enabling you to take full advantage of the Home Energy Meters features. Others may not perform any automatic configuration. In such a case you can choose to manually configure your meter to output the data that you wish to view. Setting automatic report flags. Parameter 101-103 [4 byte dec] can be configured through your gateway in case that the default settings of your meter are not what you desire. Decimal Flag 1 2 4 8 Decimal Flag 2048 4096 8192 Decimal Flag 524288 1048576 2097152 Report Total HEM:
Decimal Flag Report Watt for Clamps:
Report KWH Report Watt Report Voltage Report Current 256 512 1024 Clamp 1 Clamp 2 Clamp 3 Report KWH for Clamps: Decimal Flag Report Voltage (V) for Clamps:
65536 131072 262144 Clamp 1 Clamp 2 Clamp 3 Clamp 1 Clamp 2 Clamp 3 Report Current (A) for Clamps:
Clamp 1 Clamp 2 Clamp 3 The table above shows a decimal representation of all flags that can be set on parameter 101-103 to report specific data. Example use of the Report Table. For example, if you want to report only the total KWH consumption, and the Wattage for clamp 3, you would add 1 + 1024 and set the sum (1025) to parameter 101, 102, or 103. As another example, if you want to report Wattage and KWH power consumptions for all clamps, you would add 256 + 512
+ 1024 + 2048 + 4096 + 8192, then set the sum (16128) to parameter 101, 102, or 103. And if you want to report everything, you would add the whole table together and set it to 101, 102, or 103. Setting an automatic report interval. Parameter 111-113 [4 byte dec] can be configured through your gateway in case the default settings of your HEM is not what you desire. Parameter 111 will set the interval for Group 1 (parameter 101), parameter 112 will set the interval for Group 2 (parameter 102), and parameter 113 will set the interval for Group 3 (parameter 103). As an example, you have set parameter 101 to report the total KWH consumption and the wattage for clamp 3, and you want to report it every 500 seconds. Set parameter 111 to 500 to accomplish this. Utilising different groups. Your Home Energy Meter has 3 different groups that you may setup, from the settings and examples above, you may configure each group to report different clamps and total reports to report at different interval. Group 1 uses Parameter 101 and 111, group 2 uses parameter 102 and 112, and group 3 uses parameter 103 and 113. Technical specifications.
-A Model number: ZW095 Input: 120V~, 60Hz, 10mA (USA version, 2P) 230V~, 50Hz, 10mA (EU/AU version, 1P/3P4) 380V~, 50Hz, 18mA (EU/AU version, 3P3) Measure range of voltage:
80V~ to 150V~ (USA version, 2P) 180V~ to 260V~ (EU/AU version, 1P/3P4) 220V~ to 400V~ (EU/AU version, 3P3) Measure range of current: 0A to 200A. Operating distance: Up to 300 feet/100 metres outdoors. C C Operating temperature: -10 to 50 . Relative humidity: 8% to 80%. Warranty. 6 Aeon Labs warrants to the original purchaser of Products that for the Warranty Period (as defined below), the Products will be free from material defects in materials and workmanship. The foregoing warranty is subject to the proper installation, operation and maintenance of the Products in accordance with installation instructions and the operating manual supplied to Customer. Warranty claims must be made by Customer in writing within thirty (30) days of the manifestation of a problem. Aeon Labs' sole obligation under the foregoing warranty is, at Aeon Labs' option, to repair, replace or correct any such defect that was present at the time of delivery, or to remove the Products and to refund the purchase price to Customer. The "Warranty Period" begins on the date the Products is delivered and continues for 12 months. Any repairs under this warranty must be conducted by an authorized Aeon Labs service representative and under Aeon Labs' RMA policy. Any repairs conducted by unauthorized persons shall void this warranty. Excluded from the warranty are problems due to accidents, acts of God, civil or military authority, civil disturbance, war, strikes, fires, other catastrophes, misuse, misapplication, storage damage, negligence, electrical power problems, or modification to the Products or its components. Aeon Labs does not authorize any person or party to assume or create for it any other obligation or liability in connection with the Products except as set forth herein. Aeon Labs will pass on to Customer all manufacturers Material warranties to the extent that they are transferable, but will not independently warrant any Material. Customer must prepay shipping and transportation charges for returned Products, and insure the shipment or accept the risk of loss or damage during such shipment and transportation. Aeon Labs will ship the repaired or replacement products to Customer freight prepaid. Customer shall indemnify, defend, and hold Aeon Labs and Aeon Labs' affiliates, shareholders, directors, officers, employees, contractors, agents and other representatives harmless from all demands, claims, actions, causes of action, proceedings, suits, assessments, losses, damages, liabilities, settlements, judgments, fines, penalties, interest, costs and expenses (including fees and disbursements of counsel) of every kind (i) based upon personal injury or death or injury to property to the extent any of the foregoing is proximately caused either by a defective product (including strict liability in tort) or by the negligent or willful acts or omissions of Customer or its officers, employees, subcontractors or agents, and/
or (ii) arising from or relating to any actual or alleged infringement or misappropriation of any patent, trademark, mask work, copyright, trade secret or any actual or alleged violation of any other intellectual property rights arising from or in connection with the products, except to the extent that such infringement exists as a result of Aeon Labs' manufacturing processes. IN NO EVENT SHALL AEON LABS BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES, OR DAMAGES FOR LOSS OF PROFITS, REVENUE, OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHETHER IN AN ACTION IN CONTRACT, OR TORT, OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AEON LABS' LIABILITY AND CUSTOMER'S EXCLUSIVE REMEDY FOR ANY CAUSE OF ACTION ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH OF WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES, IS EXPRESSLY LIMITED TO, AT AEON LABS' OPTION, REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE PRICE FOR THAT PORTION OF PRODUCTS WITH RESPECT TO WHICH DAMAGES ARE CLAIMED. ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR THE SALE OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING WITHIN THIRTY (30) DAYS FROM AEON LABS'S DELIVERY, OR THE DATE FIXED FOR DELIVERY IN THE EVENT OF NONDELIVERY. THE INDEMNITY AND WARRANTY IN ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER INDEMNITIES OR WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. FCC NOTICE (for USA) THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT.SUCH MODIFICATIONS COULD VOID THE USERS AUTHORITY TO OPERATE THE EQUIPMENT. STORE INDOORS WHEN NOT IN USE. SUITABLE FOR DRY LOCATIONS. DO NOT IMMERSE IN WATER. NOT FOR USE WHERE DIRECTLY EXPOSED TO WATER. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1 2 This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation. Warning Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. Certifications (regional):
Z-Wave and Z-Wave Plus are registered trademarks of Sigma Designs and its subsidiaries in the United States and other countries This product has been tested to the requirements of CAN/CSA-C22.2 No.61010-
1, second edition, including Amendment 1, or a later version of the same standard incorporating the same level of testing requirements. Double insulation Caution, risk of danger CONFORMS TO UL STD 61010-1, CERFIFIED TO CSA STD C22.2 NO.61010-1, IEC61010-
2-032 Version:501005400001-AA www.aeotec.com