GW1200 GATEWAY INSTALLATION & CONFIGURATION GUIDE Disclaimer The information and know-how included in this document are the exclusive property of STANLEY Healthcare and are intended for the use of the addressee or the user alone. The addressees shall not forward to another their right of using the information, know-how or document forwarded herewith, in whole or in part in all matters relating or stemming from or involved therein, whether for consideration or without consideration, and shall not permit any third party to utilize the information, know-how or the documents forwarded herewith or copies or duplicates thereof, unless at the companys consent in advance and in writing. Any distribution, advertisement, copying or duplication in any form whatsoever is absolutely prohibited. The Company reserves the right to sue the addressee, user and/or any one on their behalves, as well as third parties, in respect to breaching its rights pertaining to the intellectual rights in particular and its rights of whatever kind or type in the information, know-how or the documents forwarded by them herewith in general, whether by act or by omission. This document is confidential and proprietary to STANLEY Healthcare and is not to be distributed to any persons other than licensed AeroScout Visibility System users or other persons appointed in writing by STANLEY Healthcare. Trademark Acknowledgements AeroScout is a trademark of Stanley Black & Decker. Other brand products and service names are trademarks or registered trademarks of their respective holders. Below is a partial listing of other trademarks or registered trademarks referenced herein:
Hugs Infant Protection System is a registered trademark of Stanley Black & Decker or its affiliates. Cisco is a trademark of Cisco Systems, Inc. Sun, Sun Microsystems, the Sun Logo, Java, JRE and all other Sun trademarks, logos, product names, service names, program names and slogans that are referred to or displayed in this document are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries. This product includes software developed by the Apache Software Foundation (http://www.apache.org/). This product includes code licensed from RSA Data Security Skype, SkypeIn, SkypeOut, Skype Me, the Skype Logo and the S logo and other marks indicated on Skypes website are trademarks of Skype Limited or other related companies. ESper is a trademark of EsperTech, Inc. Jboss is a trademark of Red Hat Middleware, LLC. Oracle 10G is a registered trademark of Oracle Corporation and/or its affiliates. MS SQL Server is a registered trademark of Microsoft Corporation in the United States and/or other countries. JasperSoft, the JasperSoft Logo, JasperReports, the JasperReports logo, JasperIntelligence, JasperDecisions, JasperAnalysis, Scope Center, Scope Designer, and JasperServer are trademarks or registered trademarks of JasperSoft, Inc. in the United States and other countries. Warnings A distance of at least 20 cm. between the equipment and all persons should be maintained during the operation of the equipment. Une distance d'au moins 20 cm. entre l'quipement et toutes les personnes devraient tre maintenues pendant le fonctionnement de l'quipement. 2019 STANLEY Healthcare. All rights reserved. Doc: 0981-554-000 REV A. Published January 2019. KB Article: 10597. Table of Contents Table of Contents ........................................................................................................... 3 GW1200 Gateway........................................................................................................... 4 GW1200 Features ........................................................................................................... 5 Wi-Fi Device Detection & Locator ................................................................................... 5 Network connectivity ...................................................................................................... 5 Continuous Gateway Supervision ................................................................................... 5 Monitoring of Wi-Fi Receivers ......................................................................................... 5 LED Status Indicators ...................................................................................................... 6 Connector Panel ............................................................................................................. 7 Network and Power Connections to the GW1200 Gateway ........................................... 8 Resetting the GW1200 Gateway IP Address ................................................................. 11 GW1200 Naming Convention ....................................................................................... 12 Adding & Configuring the GW1200 via AeroScout Engine Manager (AEM) .................. 13 Updating Firmware Gateways ................................................................................... 14 Mounting the Gateway ................................................................................................ 15 Fixing the Controller to a Floating Ceiling: .................................................................... 15 GW1200 and Accessories Model Numbers ................................................................... 29 GW1200 Specifications ................................................................................................. 30 Regulatory Compliance & Warranty ............................................................................. 31 FCC ................................................................................................................................. 31 Industry Canada ............................................................................................................ 31 RoHS .............................................................................................................................. 32 CE Conformance ............................................................................................................ 32 Warranty ....................................................................................................................... 32 GW1200 Gateway Installation & Configuration Guide GW1200 Gateway The GW1200 Gateway is a component of STANLEY Healthcares suite of solutions based on Wi-Fi technology, enabling hospital-wide protection of patients and infants. The Gateway is a 2.4 GHz receiver. It receives transmission messages from Hugs Wi-Fi Tags and relays the messages to the Location Engine. The Gateway is used to help provide the core layers of protection Exit, Tamper, Tag Loose and Supervision in either a Gateway only deployment with a dedicated network of Gateways providing Wi-Fi receiver coverage; or with strategically placed Gateways augmenting the facilitys existing network of Access Points in the desired protected areas. The Gateway may also be incorporated with additional use cases as determined by STANLEY Healthcare Engineering. NOTE: The relay outputs are for future functionality and are not currently supported within MobileView Hugs. Figure 1: GW1200 Gateway 4 GW1200 Gateway Installation & Configuration Guide GW1200 Features Wi-Fi Device Detection & Locator The GW1200 Gateway contains two Wi-Fi transceivers for receiving Wi-Fi messages from 802.11 b/g/n (2.4 GHz) Hugs Wi-Fi Tags. Received messages are sent to the AeroScout Location Engine for processing. Network connectivity The device supports remote programming, monitoring, and software updates by the AeroScout Location Engine. Continuous Gateway Supervision The GW1200 Gateway device status is monitored at all times by the AeroScout Location Engine. MobileView generates an alert if communication with the Gateway is compromised. Additionally, to provide full device supervision capabilities the receiver modules in the Gateway will switch into a test transmission mode simulating Tag message transmission, to verify reception of each other if no AeroScout tag messages are received within a 60 second period. Monitoring of Wi-Fi Receivers The GW1200 Gateway constantly supervises the functionality of its two Wi-Fi receivers. 5 GW1200 Gateway Installation & Configuration Guide LED Status Indicators The GW1200 Gateway has a single LED that changes color based on the device status as follows:
Constant Green: The Gateway is on and working correctly Constant Orange: Gateway failure or network down No LED indication: Gateway is off Figure 2: GW1200 Gateway LED Indicator 6 GW1200 Gateway Installation & Configuration Guide Connector Panel The GW1200 Gateway has three connectors on the connector panel. Note When both PoE and external power supplies are used the external power source is the primary power source.
(#1) Ethernet LAN Connection: RJ-45 connector. In a configuration with a physical Ethernet cable connection to the LAN, the network cable is attached here. The GW1200 supports 100 Mb Full duplex communications. The Ethernet Network Switch must be configured to Auto Negotiation mode for the Gateway to operate at 100 Mb.
(#2) Power Jack: Accepts an input voltage of 24-48V DC. This is a standard 5 mm (outer) 2.5 mm (internal) jack connector for direct power supply. A power adapter is not supplied with the Controller and can be purchased separately. When PoE is used, this connector becomes redundant.
(#3) IN/RS-232 and OUT/RS-232 Connector: RJ-45 connector. RS-232 is used as a console interface with the Exciter Manager Application (to change the IP address, for example). For this option, a special 10-pin RJ45 to DB9 serial cable (AeroScout PN 40031500000) is required.
(#4) IP Reset: Restores the Gateway's IP address to the factory default value. Inputs and Outputs are currently not in use. Note 7 GW1200 Gateway Installation & Configuration Guide Network and Power Connections to the GW1200 Gateway The following is a summary of available power and network options:
Usage Option Description Single GW1200 Gateway connected to a network GW1200s can be remotely controlled (for configuration and monitoring purposes) via the local area network. In this case, connect it to both a power source and the network. GW1200s support power-over-Ethernet (PoE), which supplies both power and network services via a single connection. Power options are 24-48V or PoE. Direct Power Supply Connect a 24 to 48 VDC power source direct to the Gateways power jack. Note The GW1200 requires approximately 8 W of power. When connecting a Gateway to a direct power source with one of the above options, verify that the provided power level is sufficient. The device must only be powered by a limited (marked LPS or NEC class 2) power supply. PoE Switch If the network has a Power-over-Ethernet infrastructure, a CAT-5/6 Ethernet cable connects the PoE switch to the Gateways LAN connector. This supplies both the power and the network connection. PoE standard 802.3af class 0 allows power for a single GW1200 Gateway. Note 110/220 VAC to 48 VDC PoE Single-Port Injector The PoE Single Port Injector converts 110/220 VAC to 48 VDC and permits connecting a single cable from the network to the Gateways LAN connector, thus supplying both power and network connectivity. 8 GW1200 Gateway Installation & Configuration Guide When using this injector, the Gateway power jack is not used. Figure 3: 110/220 VAC to 48VDC PoE Single-Port Injector The injectors IN connector is connected to the network. The injectors OUT connector is connected to the Gateways LAN connector. 110/220 VAC to 48 VDC Power Supply Adapters These adapters convert 110 VAC or 220 VAC to 48 VDC. Figure 4: 110/220 VAC to 48 VDC Adapter The adapter is connected to the GW1200 Gateway power jack. The network must be connected separately to the Gateway LAN connector. 9 GW1200 Gateway Installation & Configuration Guide Power Connection Summary The following table summarizes the power connection options:
Power Supply Input Output Max. Available Current Power PoE single port injector 100-240 VAC, 50-60 Hz 48 VDC 0.32 A(1) 15.4 W Standard PoE 802.3af switch port (2) External power adapter 48 VDC 0.32 A(1) 15.4 W 48 VDC
> 0.4 A
> 20 W Maximum # of Exciters with One Source One GW1200 Gateway One GW1200 Gateway One GW1200 Gateway Note To prevent excessive power loss, PoE cables must not exceed 100 m (330) in length. 10 GW1200 Gateway Installation & Configuration Guide Resetting the GW1200 Gateway IP Address The GW1200 Gateway IP address can be reset to the factory default value of 192.168.1.178. The Gateway does not support DHCP; requiring all device addresses to be manually configured. Press the IP Reset button with a ballpoint pen for at least 10 seconds. Figure 5: IP Reset Button 11 GW1200 Gateway Installation & Configuration Guide GW1200 Naming Convention In line with our recommended best practice, when configuring the GW1200 Gateways in the AeroScout Location Engine, use recognizable names for the GW1200 Gateways as the Gateway names are used in the alert distribution, and should provide clear information for the alert location. 12 GW1200 Gateway Installation & Configuration Guide Adding & Configuring the GW1200 via AeroScout Engine Manager (AEM) GW1200 Gateways are manually added and configured to appear on the map as an Exciter. Multiple Gateways can be added to the Location Engine using the Load Devices option on the Repository tab, or the Scanning for Devices option after setting their IP addresses and connecting them to the network. For more information refer to the AeroScout Location Engine Deployment Guide Receivers section under Adding Receivers. 13 GW1200 Gateway Installation & Configuration Guide Updating Firmware Gateways Updating the Firmware of GW1200 Gateways is performed in the Engine Manager. For more information refer to the AeroScout Location Engine Deployment Guide Upload Exciter Firmware section. 14 GW1200 Gateway Installation & Configuration Guide Mounting the Gateway Position and mount each GW1200 Gateway according to the site survey recommendations. Fixing the Controller to a Floating Ceiling:
Mounting on a Wide grid with Flush Tiles For this mounting option no mounting kit is required. Attach the device to the false ceiling using the ceiling mounts located on the bottom casing of the device 1. Align the Mounting clips with the wide grid. 2. Twist and click the Exciter into place. 15 GW1200 Gateway Installation & Configuration Guide Figure 6: Correct Complete Mounting Position Mounting Off-Grid For this mounting option the following parts from the Heavy Duty, Off Grid, Exciter Mounting kit (EXAC-HDUTY-1000) are required:
Part Letter Part Name Quantity Image A Mounting Adaptor 1 x 3 Phillips Screw 2 Hex Nut Spring washer Flat washer Bracket 512HD 6 2 2 1 E G I H D 16 GW1200 Gateway Installation & Configuration Guide 1. Cut the Mounting Adaptor (A) so that only Section # 1 remains. Use Mount Adaptor part marked with <= 1 =>
2. Step 2 Fasten 2 Screws (E) on the 512HD Bracket (D) with 1 Flat Washer (H) and 1 Spring Washer (I). Set the distance between the Screws using the Adaptor (A). 3. Drill 2 holes* in the designated for installation ceiling tile for the Screws (E). Use the assembled 512HD Bracket (D) to mark the location of the holes.
* Holes should be 5/16 or 8mm in diameter 17 GW1200 Gateway Installation & Configuration Guide 4. Mount the Assembled 512HD Bracket (D) on the tile. Fix in place 2 Nuts (G) on each of the Screws (E) leaving enough screw length (2/5 or 10mm) to mount the Adaptor. 5. Mount the Adaptor using 2 Nuts (G) using a 7/16 nut driver. 6. Mount the Exciter onto the Adaptor (A) on the ceiling tile. 18 GW1200 Gateway Installation & Configuration Guide Figure 7: Correct Complete Mounting Position 19 GW1200 Gateway Installation & Configuration Guide Mounting on a Narrow-Grid T-Bar For this mounting option the following parts from the Standard Exciter Mounting kit
(EXAC-STD-1000) are required:
Part Letter Part Name Quantity Image A Mounting Adaptor 1 C J Narrow Grid Clip- 9/16 Clip with #8 Stud 2
#8-32 Hex Nyloc Nut 2 1. Cut the Mounting Adaptor (A) so that only Section # 1 remains. Use Mount Adaptor part marked with <= 1 =>
2. Assemble the Grid Clips (C) on the Adaptor (A). Lock each Clip (C) with Hex Nut (J). The Nuts should be loose at this stage to allow easy insertion onto the grid. 20 GW1200 Gateway Installation & Configuration Guide 3. Attach the Grid Clips (C) with Mount Adaptor (A) onto the ceiling grid. (Push the clips against the grid and twist them until they lock) (turn clockwise). 4. Fasten the Adaptor (A) to the Clips (C) by tightening Nuts (J) into their final position using a 11/32" Nut Driver. 5. Mount the Exciter onto the Mounting Adaptor (A). 21 GW1200 Gateway Installation & Configuration Guide Figure 8: Correct Complete Mounting Position 22 GW1200 Gateway Installation & Configuration Guide Mounting on a Wide Grid with Recessed Tiles For this mounting option the following parts from the Standard Exciter Mounting kit
(EXAC-STD-1000) are required:
Part Letter Part Name Quantity Image A Mounting Adaptor 1 B G Wide Grid Clip-15/16 Clip with 1/4" Stud 1/4" Hex Nut 2 2 1. Cut the Mounting Adaptor (A) so that only Section # 1 remains. Use Mount Adaptor part marked with <= 1 =>
2. Assemble the Grid Clips (B) on the Adaptor (A). Lock each clip (B) with Hex Nut (G). Nuts should be loose at this step to allow easy insertion onto the grid. 23 GW1200 Gateway Installation & Configuration Guide 3. Attach the Grid Clips (C) with Mount Adaptor (A) onto the ceiling grid. (Push the clips against the grid and twist them until they lock). Fasten the Clips stud (B) against the grid using a flat screwdriver (turn clockwise). 4. Tighten Nuts (G) to final position using a 7/16" Nut Driver. 5. Mount the Exciter onto the Mounting Adaptor (A). 24 GW1200 Gateway Installation & Configuration Guide Figure 9: Correct Complete Mounting Position Mounting on a Slotted Grid For this mounting option the following parts from the Standard Exciter Mounting kit
(EXAC-STD-1000) are required:
Part Letter Part Name Quantity Image A Mounting Adaptor 1 F G For Slotted Grid-
1/4"x0.625" Phillips screw 1/4" Hex Nut 2 2 1. Cut the Mounting Adaptor (A) so that only Section # 1 remains. 25 GW1200 Gateway Installation & Configuration Guide Use Mount Adaptor part marked with <= 1 =>
2. Assemble the Screws (F) on the Adaptor. Lock each Screw (F) with Hex Nut (G)
*Nuts should be loose at this step to allow easy insertion into the slotted grid. 3. Mount the Adaptor (A) onto the Slotted-Grid by sliding the screw heads, Screw (F), through the slots. 26 GW1200 Gateway Installation & Configuration Guide 4. Fasten the Adaptor to the Screws (F) by tightening Nuts (G) to their final position using a 7/16" Nut Driver. 5. Mount the Exciter onto the Mounting Adaptor (A). Figure 10: Correct Complete Mounting Position Mounting the Gateway on a Wall While not normal practice, there may be occasions, particularly in older facilities where the ceilings are already congested, when wall mounting of the GW1200 Gateway may be the only viable option. The Gateway is shipped with a mounting template which can be used to measure the holes for mounting the Gateway on a wall. See Figure 11. The mounting plate supplied with the Gateway is not required for wall mounting. 27 GW1200 Gateway Installation & Configuration Guide Figure 11: GW1200 Gateway mounting template (supplied with the Gateway) 1. Hold the template on the wall in the location you wish to mount the Gateway. Make sure the template is level. 2. Mark the four holes for the screws through the template. 3. Remove the template. 4. Drill the holes for the screws. 5. Anchor the screws into the wall, leaving 10mm of each of the screws exposed. Use appropriate screws and or anchoring plugs. 6. Mount the Gateway with the STANLEY Healthcare logo facing up, onto the 4 screws. The Gateway's back panel has 4 mounting brackets for this purpose. 28 GW1200 Gateway Installation & Configuration Guide GW1200 and Accessories Model Numbers Product GW1200 Gateway SKU GW-1200 Power Supply APD-047-U (US) APD-047-E (Europe) APD-047-UK (UK) APD-047-J (Japan) ADP-030-U (US) ADP-030-E (Europe) ADP-030-UK (UK) ADP-030-J (Japan) EXAC-HDUTY-1000 PoE Injector Heavy Duty, Off Grid, Exciter Mounting Kit Standard Exciter Mounting Kit EXAC-STD-1000 Description GW1200 Gateway. Ethernet and PoE interface Includes 48V DC input, AC/DC adaptor 45W 48 V/1.0A 90-264VAC for EX2000B, EX4200, EX5000, EX5200 Exciters, EX5500 Controllers and GW1200 Gateways PoE Power Injector for use with EX2000B, EX3210, EX4200, EX5000, EX5200 Exciters and GW1200 Gateways. 110/220VAC-48VDC. Mounting Kit for mounting in the center of a floating ceiling tile when mounting on the ceiling grid is not possible or when heavy duty mounting is required. Fits the following Device Models: EX3210, EX4100, EX4110, EX4200, EX5000, EX5200, EX5500, External Speaker/Antenna, and GW1200. Each kit can be used for a single device. Standard Exciter Mounting Kit for Exciters and Gateways and off-grid mounting option for External Antennas/Speakers Supports recessed ceiling tiles and 3 types of ceiling grids:
- 1" Ceiling Grid
- 1/2" Ceiling Grid
- Slot Grid Fits the following Device Models: EX3210, EX4100, EX4110, EX4200, EX5000, EX5200, EX5500, External Speaker/Antenna, and GW1200. Off-grid mounting option is recommended for External Exciters/Speakers and EX3210 Exciters only Each kit can be used for a single Exciter and Gateway, or for two External Units. 29 GW1200 Gateway Installation & Configuration Guide GW1200 Specifications Product Marketing Name (PMN) GW1200 Gateway Physical and Mechanical Dimensions: 245 mm X 200 mm X 60 mm (9.6 in x 7.9 in x 2.4 in) Weight: 865 g (31oz) Housing: Polycarbonate and ABS Network Interface Ethernet (RJ-45) Wi-Fi 802.11 b/g/n Power Input voltage: 24-48 VDC PoE (802.3af) 48 VDC Maximum power consumption: 10 W. Environmental Operating temperature: 0 to 50 C (32F to 122F) Humidity: 0 to 95%, non-condensing 30 GW1200 Gateway Installation & Configuration Guide Regulatory Compliance &
Warranty FCC 47 CFR Part 15, Class B Device This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC Part 15.105(b) Warning Statement NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help. Industry Canada 31 GW1200 Gateway Installation & Configuration Guide This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. RoHS RoHS Directive 2011/65/EU CE Conformance IEC 60601-1:2005/EN 60601-1:2006 Medical Electrical Equipment IEC 60950-12005 ESTI EN 301 498-1:V2.1.1 ESTI EN 301 498-17:V3.1.1 Warranty STANLEY Healthcare (STANLEY) Standard Warranty and Disclaimer 32 GW1200 Gateway Installation & Configuration Guide For STANLEY Healthcare AeroScout Products (Products) Limited Warranty and Disclaimer. STANLEY warrants that commencing from the date of delivery to Customer and continuing for a period of one (1) year thereafter (the Warranty Period), the hardware components of STANLEY Healthcare AeroScout Products (the Hardware) will be free from defects in material and workmanship under normal use subject to the terms hereof. The date of shipment of the Hardware by STANLEY is set forth on the packaging material in which the Hardware is shipped. This limited warranty extends only to the original user of the Hardware. Customer's sole and exclusive remedy and the entire liability of STANLEY and its suppliers under this limited warranty will be, at STANLEYs or its service center's option, shipment of replacement Hardware components within the Warranty Period or a refund of the purchase price if the Hardware is returned to the party supplying it to Customer, if different than STANLEY, freight and insurance prepaid. STANLEY replacement parts used in Hardware repair may be new or equivalent to new, and STANLEY reserves the right to provide replacement Hardware components of similar form and function, as long as the functionality is equal or better than Customers original Hardware components. STANLEYs obligations hereunder are conditioned upon the return of affected Hardware in accordance with STANLEYs then-current Return Material Authorization (RMA) procedures. Notwithstanding the foregoing, the warranty for TAG Hardware specifically designated for sterilization via autoclave or other sterilization methods shall have a warranty period of 350 sterilization cycles from the date of delivery; provided, however, that sterilization outside of environmental specifications approved in any applicable user documentation voids all warranties. Extended Warranty: STANLEY offers an extended warranty, for a fee, on AeroScout products. Within the one (1) year of the standard warranty, additional warranty of two (2) years may be purchased. Additional warranty years may only be purchased once within the first one (1) year, or prior to warranty expiration. A maximum of three (3) total warranty years are available for Hardware. Exclusions: The warranty set forth above will not apply if the Hardware or the Product (i) has been altered, except by STANLEY, (ii) has not been installed, operated, repaired, or maintained in accordance with instructions supplied by STANLEY, (iii) has been subjected to abnormal physical or electrical stress, misuse, negligence, or accident; or (iv) is provided for beta, evaluation, testing, or demonstration purposes for which STANLEY does not receive a payment of purchase price or license fee. In addition, this warranty shall not cover the following:
Batteries (other than DOA -Dead On Arrival). Plastics (including defects in appearance, cosmetics, decorative or structural items including framing and non-operative parts). Tag Calibration. Expenses related to removing or reinstalling the Products. Defects or damage that result from the use of Non-STANLEY certified Products, Accessories, Software or other peripheral equipment. Defects or damages resulting from service, testing, adjustment, installation, maintenance, alteration, or modification in any way by any party other than STANLEY, or its authorized service partners. All software contained in or otherwise part of STANLEY Healthcare AeroScout Products, which is covered by STANLEYs separate software warranty contained in the separate software license agreement with respect to such Products. 33 GW1200 Gateway Installation & Configuration Guide The warranty set forth above shall not be enlarged and no obligation or liability shall arise out of STANLEYs rendering of technical advice, facilities or service in connection with Customer's purchase of the STANLEY Healthcare AeroScout Products. Except for the foregoing warranties, which shall be the exclusive warranties with respect to any Products, STANLEY MAKES NO WARRANTY OR REPRESENTATION OF ANY KIND, EXPRESS OR IMPLIED, WRITTEN OR ORAL, REGARDING INFORMATION GIVEN OR THE PRODUCTS OR SERVICES SUPPLIED AND EXPRESSLY DISCLAIMS ALL EXPRESS AND IMPLIED WARRANTIES, REPRESENTATIONS AND CONDITIONS, INCLUDING WITHOUT LIMITATION ALL WARRANTIES AND CONDITIONS OF QUALITY, NON-INFRINGEMENT, MERCHANTABILITY AND SUITABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW. STANLEY WILL NOT BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL, INDIRECT OR PUNITIVE DAMAGES FOR ANY CAUSE OF ACTION, WHETHER IN CONTRACT, TORT OR OTHERWISE. Consequential, incidental and indirect damages include, but are not limited to, lost profits, lost revenue and loss of business opportunity, whether or not STANLEY was aware or should have been aware of the possibility of these damages. 34 About STANLEY Healthcare STANLEY Healthcare provides over 5,000 acute care hospitals and 12,000 long-term care organizations with enterprise solutions that create a safe, secure and efficient healthcare experience across lifes stages. The STANLEY Healthcare solution set enables customers to achieve organizational excellence and superior care in critical areas:
Patient/Resident Safety, Security & Protection, Environmental Monitoring, Clinical Operations & Workflow and Supply Chain & Asset Management. These solutions are complemented by STANLEY Healthcares By Your Side Lifetime Customer Care commitment to ensure that every customer achieves success and realizes the full value of their investment, through consulting, training, implementation and integration services. STANLEY Healthcare is proud to be part of Stanley Black & Decker, Inc. For more information, visit stanleyhealthcare.com. Follow STANLEY Healthcare on Facebook, Twitter, LinkedIn and YouTube. STANLEY Healthcare 130 Turner Street Building 3 Waltham, MA 02453 Tel: +1-888-622-6992 North America E-mail: stanleyhealthcare@sbdinc.com Asia-Pacific E-mail: stanleyhealthcare-asiapac@sbdinc.com Europe E-mail: shs-uk@sbdinc.com Latin America E-mail: stanleyhealthcare-latam@sbdinc.com Middle East E-mail: stanleyhealthcare-MEA@sbdinc.com
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-02-06 | 2412 ~ 2462 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-02-06
|
||||
1 | Applicant's complete, legal business name |
AeroScout
|
||||
1 | FCC Registration Number (FRN) |
0024444754
|
||||
1 | Physical Address |
2 Ilan Ramon St.
|
||||
1 |
Ness -Ziona, N/A 7403635
|
|||||
1 |
Israel
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@timcoengr.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
Q3H
|
||||
1 | Equipment Product Code |
GW1000
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
R******** A****
|
||||
1 | Title |
VP HW R&D
|
||||
1 | Telephone Number |
972-8********
|
||||
1 | Fax Number |
972-8********
|
||||
1 |
r******@sbdinc.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | GW1200 Gateway | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power listed is conducted. End-users must be provided with the specific operating instructions for satisfying RF exposure compliance. The device must operate with the minimum separation distance tested for compliance, as described in this filing, which is 20 cm. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
ITL PRODUCT TESTING LTD
|
||||
1 | Name |
I******** C******
|
||||
1 | Telephone Number |
972-8********
|
||||
1 | Fax Number |
+972 ********
|
||||
1 |
i******@itl.co.il
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2412.00000000 | 2462.00000000 | 0.0022900 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC