1. FRONT FACES OF FRONT HOUSING ITEM 1 TO BE FREE OF SINK MARKS, FLOW LINES, FLASH, DISCOLOURATIONS AND SURFACE INCONSISTENCIES. 2. PAD PRINTING TO BE SMUDGE FREE AND CENTERED AS SHOWN. INK COLOUR TO BE PANTONE COOL GRAY 9C. REFER TO FRONT HOUSING DRAWING ITEM 1. 3. CONNECTOR ITEM 5 TO BE INSERTED INTO BACK PLATE ITEM 2 AS SHOWN. 4. PROTECTIVE FILM SHEET TO BE APPLIED TO FRONT OF HOUSING TO PROTECT LCD DISPLAY. SEE NOTE 3 9 8 ASM-99-MX01 7 PCA-99-MX01 6 5 AVN-018-1-00081 4 AVN-065-2-00044 PRODUCT LABEL PCBA PRODUCT LABEL FCC LABEL CONNECTOR THREAD CUTTING SCREW FOR PLASTIC. SIZE #4 x 3/8" LONG, PHILIPS PAN T-25 PCB ASSEMBLY 1 1 1 1 4 1 1 1 3 PCA-99-MX01 2 PLS-99-MX01-P1813-R BACK PLATE 1 PLS-99-MX01-P1813-F FRONT HOUSING ITEM PART NUMBER DESCRIPTION QTY THIS DOCUMENT CONTAINS RESTRICTED, PROPRIETARY, COPYRIGHTED INFORMATION, OWNERSHIP OF WHICH IS RETAINED BY AVNAN ELECTRO INC. RE-
PRODUCTION, IMPLEMENTATION, PUBLICATION OR OTHER USE OF SUCH INFORMATION IS PROHIBITED UNLES AUTHORIZED BY AVNAN ELECTRO INC. WITH WRITTEN CONSENT TOLERANCES:
LINEAR:
ANGULAR: 1 0.1 UNITS: MILIMETERS DRAWING NAME:
MAX WALL CONTROL ASSEMBLY 2590 SHERIDAN GARDEN DR. #2 OAKVILLE, ONTARIO. L6J 7R2 TEL: 1-888-286-2698 FAX: 1-888-419-9997 DATE:
DRAWN BY:
2019-01-31 A.P. P/N SCALE 1:1 SHEET 1 OF 1 ASM-99-MX01-A Steps to Set up the 99-MX-01 Note: Refer to Home Owners manual for explanation of modes of operation. 1. Turn the control ON using ON/OFF button 2. Use Mode button
=> Fan speed; =>Circ or Recirc mode; =>Dehumidistatlevel; =>IAQ enable; =>
Wireless timer pairing; =>Maintenance Reset; =>Factory Setting; => Fan speed;
to cycle the following items:
/ Down
/ Down or Down button to button to 1, use the Up
, or Recirculation*
or combination of both. button to change the setting;
Press the Up After 6 seconds, the display will go back to normal. 3. Set Fan speed change fan speed from 0 to 5. 4. Set Mode,use the Up change Ventilation
* Recirculation not available on all models. 5. Set Dehumidistat level, The control displays the indoor humidity in LARGE numbers and % RHlegend, and settings is under SET POINT in SMALLnumbers.Press and hold the Up desired indoor humidity or OFF to cancel thisfunction. If the indoor humidity is above the humidity settings, the unit will go into HIGH speed. 6. Enable/Disable the Indoor Air Quality display The Indoor Air Quality screen will appear 5 bars on top of the LCD. Press the Up Dispaly/Remove the Indoor Air Quality display. Note: Refer to Home Owners manual for the Indoor Air Quality function speed adjustment. 7. While the Signal Strength icon Up bars stopped move, the pairing is finished. Press the Up timer; or press Mode button button to toggle the button to select the exit pairing. or Down
/ Down display on the right side of the screen, Press the to start the Remote timer pairing. The 5 bars will show the progress. Until the 5 to start pairing next remote 8. RESET service display: Press the Up
(or Down disappear. This will reset the service counter to 0.
) buttonuntil service indicator
)
(or Down 9. When display shows FACS for Factory Setting, Press the Up button to toggleON and OFF. When choice ON, the unit will restore to FACTORY Setting: fan speed 1 (LOW), Ventilation mode, and Dehumidistat settings of 40%.
(Note: FACS shows on clock digits; ONon RH digits, OFF on Setpoint digits.) 10. 20/40/60 Minutes High Speed Timer This function temporarily initiates high speed ventilation for 20, 40, or 60 minutes. Press Timer button or 0 to cancel the function. to select 20, 40, 60 minutes 99MX01InstallerConfigurationandAirFlowAutoBalancingprocess:
Step1 Precondition:HRVSystemispoweronandinanyrunningMode;LCDbacklightingisdim;
Step2 PressandHoldPOWERiconfor10seconds;TheInstallerConfigurationscreenappears;
ReleasethePOWERbutton;
Press"IndoorAirQuality"areatoselect"Display"orRemove"IAQfunction;
Press"VentilationSystem"totogglefromEnglishtoFrench;
Press"SYSTEMEDEVENTILATION"totogglefromFrenchtoEnglish;
Press"SETPINT""DEF"torecalltheFACTORYDEFAULT;
Press"UP"DOWN"icontosettheRelativeHumiditytomatchtherealreadingoftheroom;
Press"MODE"icontosaveandexittheconfigstageandgotoAirFlowBalancingstage;theAir FlowBalancinginitialscreenwillappear;
Step3 Press"FLOWADJUST"icon,theVoltageinputandLeft/RightHandselectionscreendisplays;
TheTOPprogressbarwillshow1bar;
Pressthe"UP"or"DOWN"buttontochangethevoltage;
PresstheUpperHouseicontotoggletheSupplyLeft/Rightchoice;
PresstheLowerHouseicontotoggletheExhaustLeft/Rightchoice;
Step4 Press"FLOWADJUST"tostarttheAutoBalancingcalibration;
TheTOPprogressbarwillshow2bars;
Step5 Whenthecalibrationisdone,HRVwillstartAirFlowAutoBalancingfromSpeed5toSpeed1;
TheTOPprogressbarwillshow3bars;
Step6 WaituntilAirFlowAutoBalancingdone:
TheTOPprogressbarwillshow4bars;
IfyousatisfytheAutoBalancingresults,while"SPEED"is0,Press"FLOWADJUST"tojumpto nextstep;
Ifyouwanttoverifyoradjusttheairflow,pressonthe"FAN"icontochangethespeedandthe airFlowCFMwillshowontheleftmiddle;
Press"FANSPEED"icontoselectFanSpeedfrom5to0;
Press"MODE"icontoswitchbetween"Supply"and"Exhaust"toverifytheAirFlowCFM;
Press"UP"/"DOWN"icontochangethe"Supply"or"Exhaust"PWMwhichwillcausechangesof airflowCFM;
Waitseveralsecondstoallowtheairflowstabilized;
Press"FANSPEED"icontosetFanSpeedto0;then,Press"FLOWADJUST"icontogotonext step;
Step7 Inthisstep,theHRVMAXunitwillsavetheAirFlowdatatothememory;
TheTOPprogressbarwillshow5bars;
Step8 PressPOWERicontoEXITtheairflowbalancing,or,Press"FLOWADJUST"torepeattheair flowbalancingprocess(Step3). 99MX01RemoteTimerPairingprocess:
Step1 Opentheremotetimer,removebatteryifitalreadyinstalled Step2 Turnon99MX01bypressthePOWERbutton Step3 PressMODEbuttonuntilWirelessiconappearsonthescreen Step4 PressUPbuttontostartthepairing Step5 Taketheremotetimer,(Whilepressandholdthebutton,)Putthebatteryintotheremotetimer. Thefourlightwillimmediatelyflash5times,thenonlytheredbatterylightwillremainonfor12 seconds.Afterwhich,(Releasethebutton,)the"40"ledwillindicatetherevcode.Then,LED"20","40", and"60"willflashatthesametimeuntilpairedorwillstopifnotpairedwithin12seconds. Step6 Ifsuccessfullypaired,pressDOWNbuttontofinishthecurrentpairing. Step7 Putthetimer'sbackplatein.itsreadytoinstallit. Step8 Ifmoretimerneedstobepaired,gotostep4. Step9 Untilallthetimerpaired,pressMODEbuttontoexitthepairingmode FCC ID:2AS6RMX01 The device has been evaluated to meet general RF exposure requirement, The device can be used in portable exposure condition without restriction. Federal Communication Commission (FCC) Radiation Exposure Statement Power is so low that no RF exposure calculation is needed. FCC statements:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the users authority to operate the equipment.