GSM Tracker SIT1002 USER Manual 1. Product Image 2. Installation Manual 2.1 SIM Card Pre-installation, specification note. a. GSM NANO Sim Only. b. SIM card should have GPRS function enabled. c. SMS request will function only if Caller ID function is enabled. 2.2 SIM Card Installations and Removal a. Open the Sim cover at the back of the device, with the provided screw driver. b. Insert SIM card into the SIM slot, metal face down. c. Press and hold the power button until the blue light under the power button is on. It will be flashing when detecting signal, and then turns to steadily on for few seconds, and then turns off. d. Call the device SIM number and it is supposed to get through without answer. (if you are using a data sim which is not supporting call function, ignore this step.) e. Close the cover with screw driver. 3. Button Operation 3.1 Button Operation for GPS function We strongly recommend you to charge the product before using it the first time. And please be sure SIM is inserted correctly before power on. 1 / 7 a. Power On: Press and hold the power button until the blue light is on. It will keep flashing while detecting GSM signal, and turns to steadily on for few seconds and then turns off. b. Power Off: Send command *poweroff* when the SIM is inserted. If there is no SIM inserted, press and hold button until the blue light off. c. Panic Button:Press and hold power button for 3 seconds to generate a SOS call alert to the preset emergency number. No indicating light will be on. d. Charge: The blue light is steadily on during charging and turns off when it is fully charged. If threre is no LED light on, keep charging for 20 minutes and then press and hold the button to turn on the device, you will see BLUE LED light flashing and then turn to steadily on, and will turn off when fully charged. 4. Operation Commands Guide 4.1 Set APN: (VERY IMPORTANT AND MUST BE DONE 1ST) For the device to send data to the server, this command MUST be enabled. SMS: *apn*AXXX*BXXX*CXXX* This command sets the telecom Access Point Name. BXXX refers to user name, CXXX refers to password. If there is no user name and password required, send as *apn*AXXX*
If there is user name but no password required, send as *apn*AXXX* BXXX*
APN information can be checked on local telecom website. You will receive the following text: "Notice: APN is set to XXX. User name: XX. Password:
XX 4.2 Registering the Master Controller SMS to the device: *master*123456*+1XXXXXXXXXXXX*, (For instance, master controller phone number is +1XXXXXXXXXXXX. +1 refers to the country code. XXXXXXXXXXXX is the cellphone number. Please make sure country code is included, and digit 0 is not needed before cell phone number) Device Response: "Notice: Cell Phone # xxxxxxxxxx is set to master controller, the password is 123456. (The device has a default password of 123456 to initially program in your PDA/Phone. NOTE: The device will ONLY listen and respond to instructions from this number unless 2 / 7 you choose to turn on the multi controller function and open the device to any cell phone number 4.3 Changing the Password:
SMS: *password*654321* (654321 refers to new password) You will receive the following text: "Notice: The password change is successful for
+1XXXXXXXXXX. The new password is 654321. Note: Changing password command has to be sent from master controller number. 5. Motion Detected Alert the Master Controller will receive an Call/SMS alert once the device detects vibration indicating possible motion. 5.1 Set vibration sensitivity There are 5 levels of the motion sensitivity. 1 being the most sensitive, 5 the least, default setting is 1. SMS: *sensitive*1-5*
5.2 Set SMS Alert There will be a SMS alert send to master number when any motion is detected, after 3 minutes of non-movement. The system default setting is alert off, and can be turned on by command. SMS: *smsalert*
To enable motion sms alert function. SMS: *alertoff*
To turn off motion alert function. 6. Tracking via SMS 6.1 SMS: *locateaddress*
Master number will receive the Cell tower address of the device via SMS. 6.2 SMS: *locatemap*
Master number will receive a Google map link. Click the link to view the map via cellphone browser. Device will reply the map link cell tower location. 3 / 7 And this function is suitable for smart phone user only. This allows any SMS enabled cell device to query the unit for location, status, etc. System Health and status check. Returns text message indicating various system 7. Status query SMS: *status*
diagnostics 8. Multi Controller SMS: *multiquery*
Notice: Multi query feature enabled. SMS: *multiqueryoff*
The unit will now only respond to the Master controller. Device Response: to the Master Controller: Notice: Multi query feature disabled. 9. Reboot SMS: 88888888 Reboot system, previous settings will not be cleared. 10. Master query SMS: 999999 To check registered master number, password and devices serial number. 11. Default SMS: default To operate factory default, previous settings will be cleared. 12. Low battery Alert There will be a low battery SMS alert sent to master number when battery drops to 20% of its capacity, and the routetrack function will be turned off for power saving. And it will resume working when battery is charged. The alert number can be appointed to any other cellphone number if needed. Appoint low battery alert number 4 / 7 SMS:*lowbat*alert cellphone number*Note: Please make sure country code is included in the cellphone number. Example
*lowbat*+319876543210*
13.Device Information SMS: *about*
You will receive a text message include software edition information and devices serial number. 14. Command Setting List Function Command Description APN Setting
*apn*AXXX*BXXX*CXXX*
Master Setting
*master*123456*+1XXXXXXXXXX XX*
Password Changing
*password*654321*
Vibration Sensitivity Setting
*sensitive*1-5*
SMS Alert
*smsalert*
This command sets the telecom Access Point Name. BXXX refers to user name, CXXX refers to password. is
+1 refers to the country code. XXXXXXXXXXXX the cellphone number. Please make sure country code is included, and 0 is not needed before cell phone number Original password is default as 123456. 654321 refers to new password. 1 being the most sensitive, 5 the least. Default setting is 1. SMS notification will sent to master number when motion is detected after 3 minutes non-
movement.
*alertoff*
End SMS alert Address Query
*locateaddress*
Google Map Search
*locatemap*
Cell tower address information of current location. Google Map link with current cell tower location. 5 / 7 Function Command Description Status query
*status*
Check system status Multi Controller
*multiquery*
Enable multi controller function
*multiqueryoff*
End multi controller function Device Information
*about*
Reboot 88888888 Master Query 999999 Software edition information and devices serial number. Reboot the system, previous settings will NOT be cleared. Registered master number information, password and devices serial number. Low Battery Alert Number
*lowbat*country code (plus) cellphone number*
To set low battery alert number. Factory Default default Default system, previous settings will be cleared. Contact us:
Alperton Ltd 132 Derech Begin, Tel Aviv 6701101, Israel Tele: +972544987438 e-mail: Omer@shipit.to 6 / 7 FederalCommunicationsCommission(FCC)Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustaccept anyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththe instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does causeharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturning the equipment off and on, the user is encouraged to try to correctthe interference by one or moreofthefollowingmeasures:
Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Warning:ChangesormodificationsmadetothisdevicenotexpresslyapprovedbyAlpertonLtd. mayvoidtheFCCauthorizationtooperatethisdevice. Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorizedmodificationstothisequipment.Suchmodificationscouldvoidtheusersauthority tooperatetheequipment. RFexposurestatement:
Thetransmittermustnotbecolocatedoroperatedinconjunctionwithanyotherantennaor transmitter. ThisequipmentcomplieswiththeFCCRFradiationexposurelimitssetforthfor anuncontrolledenvironment.Thisequipmentshouldbeinstalledandoperatedwitha minimumdistanceof20cmbetweentheradiatorandanypartofyourbody.