happy holidays!

FCC ID: VQSAMNKHIN1 HD-SDI wireless transmitter module

by: Amimon Ltd. latest update: 2015-10-21 model: AMNKHIN1

Two grants have been issued under this FCC ID from 03/27/2014 to 10/21/2015 (this is one of two releases in 2015 for this grantee). Public details available include internal & external photos, frequency information, and manuals. some products also feature user submitted or linked password defaults, warrantee terms, troubleshooting guides, drivers, & instructions.
permalink for this FCC identifier
search for: Repair details
from iFixIt
Replacement
on Amazon
Trade-in? Recycling locations
eg is reader-supported. when you buy through links on our site, we may earn an affiliate commission.
|
|
|   
eg for Slack usage
app s submitted / available
1 2 User Manual Rev. 1 Users Manual pdf 1.80 MiB
1 2 Cover Letter(s) pdf
1 2 External Photos pdf
1 2 Test Report pdf
1 2 Test Report pdf
1 2 Test Report pdf
1 2 RF Exposure Info pdf
1 2 RF Exposure Info pdf
1 2 External Photos pdf
1 2 Internal Photos pdf
1 2 ID Label/Location Info pdf
1 2 Cover Letter(s) pdf
1 2 RF Exposure Info pdf
1 2 RF Exposure Info pdf
1 2 RF Exposure Info pdf
1 2 Cover Letter(s) pdf
1 2 Test Report pdf
1 2 Test Report pdf
1 2 Test Report pdf
1 2 Test Setup Photos pdf
1 2 Cover Letter(s) pdf
1 2 User Manual Rev. 1 Users Manual pdf 1.80 MiB

frequency equipment class purpose
1 2015-10-21 5745 ~ 5805 NII - Unlicensed National Information Infrastructure TX Class II permissive change or modification of presently authorized equipment
2 2014-03-27 5755 ~ 5795 NII - Unlicensed National Information Infrastructure TX Original Equipment

Application Forms

app s Applicant Information
1 2 Effective 2015-10-21
1 2 2014-03-27
1 2 Applicant's complete, legal business name Amimon Ltd.
1 2 FCC Registration Number (FRN) 0017004433
1 2 Physical Address 26 Zarhin St.
1 2 Raanana, N/A 4366250
1 2 Israel
app s TCB Information
1 2 TCB Application Email Address t******@metlabs.com
1 2 TCB Scope A4: UNII devices & low power transmitters using spread spectrum techniques
app s FCC ID
1 2 Grantee Code VQS
1 2 Equipment Product Code AMNKHIN1
app s Person at the applicant's address to receive grant or for contact
1 2 Name G**** N****
1 2 Telephone Number 972-5********
1 2 Fax Number 972-9********
1 2 E-mail g******@Amimon.com
app s Technical Contact
1 2 Firm Name Amimon Ltd.
1 2 Name T**** K******
1 2 Physical Address 2 Maskit St
1 2 Herzlia
1 2 Israel
1 2 Telephone Number 972-9********
1 2 Fax Number 972-9********
1 2 E-mail T******@Amimon.com
app s Non Technical Contact
n/a
app s Confidentiality (long or short term)
1 2 Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:Yes
1 2 Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:No
if no date is supplied, the release date will be set to 45 calendar days past the date of grant.
app s Cognitive Radio & Software Defined Radio, Class, etc
1 2 Is this application for software defined/cognitive radio authorization?No
1 2 Equipment ClassNII - Unlicensed National Information Infrastructure TX
1 2 Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant)HD-SDI wireless transmitter module
1 2 Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application?No
1 2 Modular Equipment TypeDoes not apply
1 2 Single Modular Approval
1 2 Purpose / Application is forClass II permissive change or modification of presently authorized equipment
1 2 Original Equipment
1 2 Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization?No
1 2 Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization?No
1 2 Grant CommentsPower listed is aggregate conducted. Modular Approval. This transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. CIIPC is to update the filing to new FCC UNII rules.
1 2 Power listed is aggregate conducted. Modular Approval. This transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. 5150-5250 MHz is for indoor applications only.
1 2 Is there an equipment authorization waiver associated with this application?No
1 2 If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded?No
app s Test Firm Name and Contact Information
1 2 Firm Name Eurofins MET Laboratories, Inc.
1 2 Name J******** F********
1 2 Telephone Number 41094********
1 2 Fax Number 41035********
1 2 E-mail j******@metlabs.com
Equipment Specifications
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
1 1 15E 38 MO 5160 5240 0.045
1 2 15E 38 MO 5260 5320 0.175
1 3 15E 38 MO 5500 5700 0.173
1 4 15E 38 MO 5745 5805 0.318
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
2 1 15E MO 5160 5240 0.034
2 2 15E MO 5190 5230 0.045
2 3 15E MO 5260 5320 0.174
2 4 15E MO 5270 5310 0.166
2 5 15E MO 5500 5580 0.132
2 6 15E MO 5660 5700 0.173
2 7 15E MO 5550 5550 0.169
2 8 15E MO 5670 5670 0.169
2 9 15E MO 5745 5805 0.251
2 1 15E MO 5755 5795 0.318

 

some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details

 

  This product uses the FCC Data API but is not endorsed or certified by the FCC