Installation Instruction The Remote Unit, Extension Unit or Master Unit must be mounted by proffessionel / special trained installer. 1.1. MECHANICAL INSTALLATION 1.1.1. Health and Safety for Mechanical Installation 1. Caution: Risk of injury by the considerable weight of the unit falling. Ensure there is adequate manpower to handle the weight of the system. 2. Caution: Risk of serious personal injury by equipment falling due to improper installation. The installer must verify that the supporting surface will safely support the combined load of the electronic equipment and all attached hardware and components. The screws and dowels (wall anchors) used should also be appropriate for the structure of the supporting wall. 3. Caution: Explosive atmospheres. To avoid explosion or fire, do not operate this equipment in the presence of flammable gases or fumes. 4. Caution: Lightning danger. Do not install or make adjustments to this equipment during an electrical storm. 1.1.2. Property Damage Warnings for Mechanical Installation 1. Attention: Do not install the unit in a way or at a place where the specifications outlined in the Environmental and Safety Specifications leaflet of the supplier are not met. Otherwise, the lifespan and performance of the repeater may be reduced. 2. Attention: Due to power dissipation, the unit may reach a very high temperature. Ensure sufficient airflow for ventilation. 3. Attention: The repeater must be installed in a vertical position. 4. Notice: Exceeding the specified load limits may cause the loss of warranty. 5. Notice: Do not place cables or tools that may damage the repeater in close proximity to it. 6. Notice: Do not wear jewelry or metal accessories when installing this repeater. 7. Notice: When connecting and mounting the cables (RF, optical, mains, ...) ensure that no water can penetrate into the unit through these cables. 8. Notice: Check all cables for shorts and opens. Verify that there are no cables with loose or poor connections. RF leakage could cause oscillation to occur under some conditions. 9. Notice: If any different or additional mounting material is used, ensure that the mounting remains as safe as the mounting designed by the manufacturer. The specifications for stationary use of the Unit must not be exceeded. Ensure that the static and dynamic strengths are adequate for the environmental conditions of the site. The mounting itself must not vibrate, swing or move in any way that might cause damage to the Unit. 10. Notice: A spacing of 40 mm (1.58 inch) around the unit is required. Specified torques must be observed for certain mounting procedures according to the following table:
Pins Type Thread Specified torques M 6 3.3 Nm Hex nuts M 6 3.3 Nm Screws M6 3.3 Nm table Specified torques 1.2. ELECTRICAL INSTALLATION 1.2.1. Health and Safety for Electrical Installation Read and observe chapter 1.3 Health and Safety. 1. Danger: Electrical hazard. Danger of death or fatal injury from electrical current. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 2. Danger: Electrical hazard. Danger of death or fatal injury from electrical current inside the unit in operation. Before opening the unit, disconnect mains power. 1.2.2. Property Damage Warnings for Electrical Installation 1. Attention: It is compulsory to ground (earth) the unit before connecting the power supply. A grounding bolt is provided on the cabinet to connect the ground-bonding cable. 2. Attention: If the mains connector of the PSR is not easily accessible, a disconnect device in the mains power circuit must be provided within easy reach. 3. Attention: A connection of the mains supply to a power socket requires the power socket to be nearby the PSR. 4. Attention: Before connecting or disconnecting the mains connector at the PSR, ensure that mains power supply is disconnected. 5. Attention: Make sure that an appropriate circuit breaker acting as a disconnect device (as required by IEC/EN60950-1) and an overcurrent limiting device are connected between mains power and the PSR. 6. Attention: Incorrectly wired connections can destroy electrical and electronic components. 7. Notice: To avoid corrosion at the connectors caused by electrochemical processes, the material of the cable connectors must not cause a higher potential difference than 0.6 V
(see electrochemical contact series). 8. Notice: Use an appropriate torque wrench for the coupling torques:
for 4.3-10 type connectors (5 Nm, 44 in lb) with 22mm (7/8) in opening, e.g. item no. TW-4310 Do NOT use your hands or any other tool (e.g. a pair of pliers). This might cause damage to the connector and lead to a malfunction of the PSR. 9. Notice: For unstabilized electric networks, which frequently generate spikes, the use of a voltage limiting device is advised. 10. Notice: Observe the labels on the front panels before connecting or disconnecting any 11. Notice: Unused connectors must be closed with their protective covers to ensure water cables. tightness. 1.3. HEALTH AND SAFETY 1. Danger: Electrical hazard. Danger of death or fatal injury from electrical current. Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. 2. Danger: Electrical hazard. Danger of death or fatal injury from electrical current inside the unit in operation. Before opening the unit, disconnect mains power. 3. Caution: High frequency radiation in operation. Risk of health hazards associated with radiation from the units inner conductor of the antenna port(s). Disconnect mains before connecting or replacing antenna cables. 4. Caution: High frequency radiation in operation. Risk of health hazards associated with radiation from the antenna(s) connected to the unit. Implement prevention measures to avoid the possibility of close proximity to the antenna(s) while in operation. 1.3.1. Property Damage Warnings 1. Attention: Due to power dissipation, the psr may reach a very high temperature. Do not operate this equipment on or close to flammable materials. Use caution when servicing the unit. 2. Attention: Only authorized and trained personnel are allowed to open the unit and get access to the inside. 3. Notice: Although the PSR is internally protected against overvoltage, it is strongly recommended to ground (earth) the antenna cables close to the antenna connectors of the PSR for protection against atmospheric discharge. In areas with strong lightning, it is strongly recommended to install additional lightning protection. 4. Notice: ESD precautions must be observed. Before commencing maintenance work, use the available grounding (earthing) system to connect ESD protection measures. 5. Notice: Only suitably qualified personnel are allowed to work on this unit and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this manual. 6. Notice: Keep operating instructions within easy reach and make them available to all users. 7. Notice: Read and obey all the warning labels attached to the unit. Make sure that all warning labels are kept in a legible condition. Replace any missing or damaged labels. 8. Notice: Only license holders for the respective frequency range are allowed to operate this unit. 9. Do not disassemble the unit. 10. Notice: Make sure the repeater settings are correct for the intended use (refer to the manufacturer product information) and regulatory requirements are met. Do not carry out any modifications or fit any spare parts, which are not sold or recommended by the manufacturer. 1.3.2. Compliance 1. Notice: For installations, which have to comply with FCC RF exposure requirements, the antenna selection and installation must be completed in a way to ensure compliance with those FCC requirements. Depending on the RF frequency, rated output power, antenna gain, and the loss between the repeater and antenna, the minimum distance D to be maintained between the antenna location and human beings is calculated according to this formula:
where P (mW) is the radiated power at the antenna, i.e. the max. rated repeater output power in addition to the antenna gain minus the loss between the repeater and the antenna. PD (mW/cm) is the allowed Power Density limit acc. to 47 CFR 1.1310 (B) for general population / uncontrolled exposures which is o o F (MHz) / 1500 for frequencies from 300MHz to 1500MHz 1 for frequencies from 1500MHz to 100,000MHz RF exposure compliance may need to be addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). 2. Notice: For installations which have to comply with European EN50385 exposure compliance requirements, the following Power Density limits/guidelines (mW/cm) according to ICNIRP are valid:
o o o 0.2 for frequencies from 10 MHz to 400 MHz F (MHz) / 2000 for frequencies from 400 MHz to 2 GHz 1 for frequencies from 2 GHz to 300 GHz 3. Notice: Installation of this equipment is in full responsibility of the installer, who has also the responsibility, that cables and couplers are calculated into the maximum gain of the antennas, so that this value, which is filed in the FCC Grant and can be requested from the FCC data base, is not exceeded. The industrial boosters are shipped only as a naked booster without any installation devices or antennas as it needs for professional installation. 4. Notice: For installations which have to comply with FCC/ISED requirements:
English:
This device complies with FCC Part 15. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This device complies with Health Canadas Safety Code 6. The installer of this device should ensure that RF radiation is not emitted in excess of the Health Canadas http://www.hc-sc.gc.ca/ewh-
requirement. semt/pubs/radiation/radio_guide-lignes_direct-eng.php. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Information obtained can be at
]/[][][24cmmWmWcmPDPD=
Antenna Stmt for ISED:
This device has been designated to operate with the antennas having a maximum gain of 9 dBi. Antennas having a gain greater than 9 dBi are prohibited for use with this device without consent by ISED regulators. The required antenna impedance is 50 ohms. The antenna(s) used for this transmitter must be installed to provide a minimum separation distance (as specified in table 1: Antenna Distances) from all persons and must not be co-
located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. French:
Cet appareil est conforme avec Sant Canada Code de scurit 6. Le programme dinstallation de cet appareil doit sassurer que les rayonnements RF nest pas mis au-del de Iexigence de Sant Canada. Les informations peuvent tre obtenues: http://www.hc-sc.gc.ca/ewh-
semt/pubs/radiation/radio_guide-lignes_direct-fra.php Antenne Stmt pour ISDE:
Ce dispositif a t dsign pour fonctionner avec les antennes ayant un gain maximal de 9 dBi. Antennes ayant un gain plus grand que 9 dBi sont interdites pour une utilisation avec cet appareil sans le consentement des organismes de rglementation dISDE. Limpdance dantenne requise est 50 ohms. Lantenne (s) utilis pour cet metteur doit tre install pour fournir une distance de sparation minimale (comme indiqu dans la table 1) par rapport toute personnes et ne doit pas tre co-localises ou oprant en conjonction avec une autre antenne ou metteur. Les utilisateurs et les installateurs doivent tre fournis avec des instructions dinstallation de lantenne et des conditions de fonctionnement de lmetteur pour satisfaire la conformit aux expositions RF. 5. Notice: The unit complies with Overvoltage Category II. It also complies with the surge requirement according to EN 61000-4-5 (fine protection); however, installation of an additional medium (via local supply connection) and/or coarse protection (external surge protection) is recommended depending on the individual application in order to avoid damage caused by overcurrent. For Canada and US, components used to reduce the Overvoltage Category shall comply with the requirements of IEC 61643-series. As an alternative, components used to reduce the Overvoltage Category may comply with ANSI/IEEE C62.11, CSA Certification Notice No. 516, CSA C22.2 No. 1, or UL 1449. Suitability of the component for the application shall be determined for the intended installation. 6. Notice: Corresponding local particularities and regulations must be observed. 7. Note: For a Class A digital device or peripheral:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 8. Note: For a Class B digital device or peripheral:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Connect the equipment into an outlet on a circuit different from that to which the receiver Increase the separation between the equipment and receiver. is connected.
- Consult the dealer or an experienced RF technician for help. 9. Note: This unit complies with European standard EN62368-1. Equipment Symbols Used / Compliance Please observe the meanings of the following symbols used in our equipment and the compliance warnings:
Symbol Compliance Meaning / Warning For industrial (Part 90) signal booster, Class B:
This is a 90.219 Class B device. WARNING: This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. You MUST register Class B signal boosters (as defined in 47 CFR 90.219) online at www.fcc.gov/signal-
boosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. For industrial (Part 90) signal booster, Class A:
This is a 90.219 Class A device. WARNING: This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. You MUST register Class B signal boosters (as defined in 47 CFR 90.219) online at www.fcc.gov/signal-
boosters/registration. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. WARNING: This is NOT a CONSUMER device. It is designed for installation by an installer approved by an ISED licensee. You MUST have an ISED LICENCE or the express consent of an ISED licensee to operate this device. AVERTISSEMENT: Ce produit NEST PAS un appareil de CONSOMMATION. Il est conu pour tre install par un installateur approuv par un titulaire de licence dISDE. Pour utiliser cet appareil, vous DEVEZ dtenir une LICENCE dISDE ou avoir obtenu le consentement exprs dun titulaire de licence autoris par ISDE. To be sold exclusively to mobile operators or authorized installers no harmonized frequency bands, operation requires license. Intended use:
EU and EFTA countries Indicates conformity with the RED directive 2014/53/EU and/or RoHS directive 2011/65/EU.
FCC
ISED CE CE Indicates conformity with the RED directive 2014/53/EU and RoHS directive 2011/65/EU certified by the notified body no. 0700. Required Antenna Distances Model Antenna gain without cable loss [dBi]
Maximum Distance DL Maximum Distance UL FCC ISED FCC ISED m inches m inches m inches m inches PSR 700/800 9 0.687 27.05 0.999 39.33 0.345 13.58 0.502 19.76 Table 1: Antenna Distances WEEE Recycling Country specific information about collection and recycling arrangements per the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations is available on CommScopes website. http://www.commscope.com/About-Us/Corporate-Responsibility-and-Sustainability/Environment/#recycling
This product uses the FCC Data API but is not endorsed or certified by the FCC