Operating Manual Metris Vibe Ex Revision: 03 00 01 02 03 25.02.2019 Operating Manual 16.02.2021 Operating Manual 03.03.2021 Operating Manual 22.03.2022 Operating Manual PJO EPG EPG EPG Confidential document. All rights reserved. No duplication or disclosure to third parties permitted without written consent from ANDRITZ. ANDRITZ AG Stattegger Strasse 18 8045 Graz, Austria Phone: +43 (316) 6902 0 Fax: +43 (316) 6902 415 www.andritz.com Legal form: Corporation Company seat: Graz, Court of registry:
Landes- und Handelsgericht Graz Company reg. no.: FN 50935 f, DVR: 005 0008, ARA license no.: 7485 VAT (UID): ATU28609707 Bank account:
UniCredit Bank Austria AG Bank code: 12000 A/c no.: 00874716400 IBAN: +43 (1100) 0008 74716400 BIC (SWIFT): BKAUATWW Operating manual: Metris Vibe Rev.: 03 1.3 1.4 1.5 1.6 1.7 2.1 2.2 3.1 3.2 3.3 3.4 3.5 Table of Contents Abbreviations ......................................................................................................................................... 3 Preface .................................................................................................................................................... 4 Information on the manufacturer ......................................................................................................... 5 1 Introduction .................................................................................................................................... 6 1.1 About this manual .................................................................................................................... 6 1.2 Warranty and liability ................................................................................................................ 6 Copyright .................................................................................................................................. 7 Intended use ............................................................................................................................ 7 Notice of claims ........................................................................................................................ 7 Shipping ................................................................................................................................... 8 Storage ..................................................................................................................................... 8 1.7.1 Incoming inspection ................................................................................................................. 8 1.7.2 Packaging ................................................................................................................................ 9 1.7.3 Storage ................................................................................................................................... 10 2 Safety ............................................................................................................................................ 13 Safety instructions .................................................................................................................. 13 Basic safety instructions ......................................................................................................... 13 3. Metris Vibe Sensor Start Up ....................................................................................................... 15 Activating the MEtris Vibe from Storage mode ...................................................................... 15 Installation instruction ............................................................................................................. 15 Downloading data .................................................................................................................. 16 Settings METRIS VIBE sensor .............................................................................................. 16 Special conditions .................................................................................................................. 17 4. Repair ............................................................................................................................................ 17 5. Decommissioning ........................................................................................................................ 18 5.1 Disposal.................................................................................................................................. 18 6. Area of Application ...................................................................................................................... 19 7. Technical data and ambient conditions .................................................................................... 20 8. Outline Drawing ........................................................................................................................... 21 9. RESERVED FOR DECLARATION OF CONFORMITY ................................................................ 22 10. FCC and ISED information .......................................................................................................... 23 10.1 Class B digital device .............................................................................................................. 23 10.2 RF Exposure Information according 2.1091 / 2.1093 / KDB 447498 / RSS-102 ................... 24 10.3 Used frequence range, used modes and antena information ................................................ 24 10.4 FCC ID ................................................................................................................................... 24 10.5 ISED ID .................................................................................................................................. 24 ANDRITZ Page 2 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 ABBREVIATIONS Ab b re via tio n De s c rip tio n European Agreement concerning the International Carriage of Dangerous ADR Goods (Accord europen relatif au transport international des marchandises dangereuses par route) CE Conformity with European directive (Conformit Europenne) EMC Electromagnetic Compatibility EN European Standard (Europa-Norm) IEC International Electrotechnical Commission Table 1: Abbreviations ANDRITZ Page 3 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 PREFACE The present operating manual contains the information required according to valid regulations
(2014/30/EU, 2014/53/EU, 2011/65/EU, 2014/34/EU) for transport, installation, operation, and maintenance of the vibration sensor METRIS VIBE. The manual is intended for persons who work with the METRIS VIBE described herein. The only way to avoid faults in the equipment and guarantee trouble-free operation is to follow this operating manual. Thus, persons responsible must be acquainted with the present operating manual and have access to it at all times. The operating manual is a part of the user information for placing the equipment on the market and must be kept in a place accessible to the operating company and to the operating personnel. If the location of the equipment is changed, the manual and/or operating instructions must be passed on with the equipment. The remarks in the manual and/or operating instructions must be observed at all times during the service life of the equipment. Read through the appropriate section in the operating instructions carefully before starting work. ANDRITZ does not accept any liability in the event of operating faults and any damage that may be caused as a result of this manual not being obeyed. ANDRITZ Page 4 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 INFORMATION ON THE MANUFACTURER ANDRITZ AG Stattegger Strasse 18 A-8045 Graz, Austria Phone: +43 (316) 6902 0 Fax: +43 (316) 6902415 www.andritz.com
(referred to below as ANDRITZ) Legal form: Corporation Company seat: Graz, Court of registry Landes- und Handelsgericht Graz Company reg. no.: FN 50935 f, DVR: 005 0008, ARA license no.: 7485 VAT (UID): ATU28609707 ANDRITZ Page 5 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 1 INTRODUCTION This manual is describing the METRIS VIBE sensor supplied by ANDRITZ. Condition Monitoring Systems (CMS) are described as systems that monitor the condition of machines and systems to provide advanced detection or prediction of damage. As consequences increased vibrations are indicating increased wear, damage to bearings, rotating parts, the frame of the machine or the building. To identify characteristic frequencies Fast Fourier transformation is used. The Andritz METRIS VIBE sensor uses Bluetooth (BLE) communication to send information via Industrial Gateways to a Cloud for further analyzing and storage. The sensor is taking short samples of the actual vibration stream based on an adjustable interval. The manual contains essential information on correct, safe, and fit-for-purpose operation of the Metris Vibe sensor. Adherence to these instructions helps to avoid dangerous situations known The personnel assigned to work with the Metris Vibe sensor must read the manual before commencing work. It is too late to do so while working on the equipment, which may have serious to date. 1.1 ABOUT THIS MANUAL Ta rg e t a u d ie n c e technical and health consequences. In particular, the following must be considered:
the entire Safety section and 1.2 WARRANTY AND LIABILITY the safety instructions provided in the individual sections of the manual. ANDRITZ excludes warranty and liability claims for defects or damage if these are due in particular to one or several of the reasons mentioned below:
Non-compliance with safety information, recommendations, instructions, and/or other information in the manual. ANDRITZ Page 6 of 25 March 22, 2022 Operating manual: Metris Vibe Incorrect start-up and operation of the METRIS VIBE sensor. Use of the METRIS VIBE sensor for purposes other than its intended use. Unauthorized structural changes or additions to the METRIS VIBE sensor that do not conform to the basic configuration supplied and tested as well as changes to the user This document is protected by copyright and contains confidential information belonging to ANDRITZ and/or companies affiliated to ANDRITZ. By accepting this document, each partner expressly confirms that he will not copy, duplicate, or make it available to third parties, nor disclose or forward it to anyone except with the express consent of ANDRITZ or a subsidiary of Rev.: 03 software. 1.3 COPYRIGHT ANDRITZ. 1.4 INTENDED USE The METRIS VIBE sensor may only be used in accordance with the present operating manual. Any operations outside the performance limits stated in the chapter of technical specification and result in damages for which ANDRITZ shall not accept any liability. Intended use also includes compliance with this manual, adhering to operating conditions. The Metris Vibe sensor is used for measuring the vibration and temperature of suitable equipment. It is not allowed to use the METRIS VIBE sensor for fixing purposes. Correct and safe operation of the Metris Vibe sensor requires proper transport and storage, installation and assembly, as well as careful operation. 1.5 NOTICE OF CLAIMS ANDRITZ must be informed immediately of any defects or damage detected by the customer or operating personnel or other deviations from the normal operating condition regardless of whether they occur during or after expiry of the warranty period. This notification to ANDRITZ should include the following information in particular:
Description of defect or damage (symptoms, detected when and by whom) Identification of systems or components affected (identification number) ANDRITZ Page 7 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 1.6 SHIPPING NOTICE Special symbols are printed on the packaging according to common international practice. It is important to take these symbols into account when loading, unloading, or moving the goods. Non-compliance with these instructions can result in material damage. If in doubt, always ask the manufacturer to organize a suitable solution. The following ambient conditions apply to shipping and storage as well as in operation:
dry frost-free corrosion-protected (e.g. salt water) Symbols on goods for transport:
Name Vor Nsse schtzen Keep dry Symbol Table 2: Goods for transport symbols 1.7 STORAGE 1.7.1 INCOMING INSPECTION ANDRITZ Page 8 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 Da m a g e Check the deliveries immediately for visible damage upon arrival at the place of destination, preferably in the presence of the forwarding agent. Care must be taken to ensure that special packaging is not damaged In fo rm a tio n during the inspection. In case of obvious transport damage proceeds as follows:
1. Take photos of the transport damage. 2. Open the damaged package only to the point where damage to components can be 3. Then re-pack the damaged components carefully and store them in a dry place. Check the consignment for completeness using the packing list. Inform the department verified and documented. Co m p le te n e s s responsible of any missing parts. 1.7.2 PACKAGING Depending on the packed components, the packaging serves to provide protection or only to cover the parts and components of the METRIS VIBE sensor. In fo rm a tio n Sealed packaging must not be opened on the way to the destination or during handling. Customs and forwarding agents must be informed in good time about the forthcoming arrival of such consignments. Arrange with the customs officials to have the goods inspected on site. Sealed packaging is used for very sensitive components that are to be stored in the country of destination for a long time. ANDRITZ Page 9 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 Follow the respective disposal instructions for environmentally friendly In fo rm a tio n disposal of the packaging. 1.7.3 STORAGE NOTICE Parts that are not stored correctly can suffer damage after a short period of time due to climatic influences, resulting in a need for repeat treatment or re-machining. individual parts. Always follow the manufacturers information regarding storage of Each packing unit is assigned to a storage class in accordance with the packing list. Store all packing units delivered according to their storage classes (or higher storage classes) at the place of destination after they have been accepted. The conditions and minimum requirements of the 6 storage classes are described in Table 3:
ANDRITZ Page 10 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 Sto ra g e Sto ra g e c la s s lo c a tio n Sto ra g e c o n d itio n s Min im u m re q u ire m e n ts 1 No symbol Open-air storage area
(outdoors) Stabilized, drained gravel floor Open-air storage Covered open-air storage area or trajectory roof Covered storage areas Stabilized, drained gravel Heated rooms > 8C Tarred or concrete floor if forklifts or mobile cranes are floor used Warehouse Air-conditioned rooms 0 40C Relative humidity 10 75%
Dangerous goods store Electric lighting Shelves and racks protected against vermin and rodents Table 3: Storage classes NOTICE In order to avoid rust film on parts made of stainless steel, always store them separately from parts made of carbon steel. The parts should be left in their original packaging wherever possible. Always consider the maximum permitted floor load when storing goods. 2 3 4 5 6 ANDRITZ Page 11 of 25 March 22, 2022 Operating manual: Metris Vibe 1.7.3.1 STORAGE OF METRIS VIBE SENSORS The following information should be considered when putting METRIS VIBE sensors into It is p o s s ib le to s to ra g e th e METRIS VIBE Ex s e n s o rs u p to 2 ye a rs if th e s e n s o r is n o t Rev.: 03 storage:
a c tiva te d . Sto ra g e a c c o rd in g to s to ra g e c la s s in d ic a te d o r s to ra g e c la s s 4 a s a m in im u m :
The parts must be supported securely on wooden boards covered with plastic sheeting at a height of approximately 15-20 cm from the floor. Store small and, in particular, unpacked parts on storage racks. Take fire protection regulations into account. ANDRITZ Page 12 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 2 SAFETY Safety instructions for components that were not manufactured by ANDRITZ are included in the descriptions of the component suppliers and must be obeyed as well. 2.1 SAFETY INSTRUCTIONS Everything mentioned in the Safety section is important and safety-relevant. The warning notices mentioned in the individual sections are marked with a pictogram, signal word, and signal color as follows:
Ordinance, etc. Choice and execution of danger symbols in accordance with ADR, Dangerous Material Th is m a rkin g wa rn s o f a n im m in e n t h e a lth ris k. Ignoring these instructions can result in moderate or slight injuries and to environmental and material damage. CAUTION NOTICE Th is m a rkin g wa rn s o f a d a n g e ro u s s itu a tio n . Ignoring these instructions can result in material damage. In fo rm a tio n Th is m a rkin g c o n ta in s u s e fu l in fo rm a tio n . The activity described will be easier to perform professionally if this information is taken into consideration. 2.2 BASIC SAFETY INSTRUCTIONS The METRIS VIBE sensor has been built according to the state of the art, as well as acknowledged safety regulations and specifications. ANDRITZ Page 13 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 ANDRITZ Page 14 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 3. METRIS VIBE SENSOR START UP 3.1 ACTIVATING THE METRIS VIBE FROM STORAGE MODE It is necessary to activate the Metris Vibe sensor from storage mode before installing it on equipment. This is possible with the Metris Vibe mobile App. In the App you have to connect for the first time with the sensor for activation. When using the gateway router this happens automatically. The serial number is printed on each sensor starting with Axxxx. 3.2 INSTALLATION INSTRUCTION The accuracy of the high frequency response is directly affected by the mounting technique selected. Maximum output will be generated when vibration is acting along the center axis of the vibration sensor (this is particularly important when monitoring bearings and ventilation fans). The vibration sensor is equally effective at detecting vibration in housing and casings. It is important to identify points of vibration where the maximum output signals can be obtained. It is also important to prepare an accurate mounting position for the vibration sensor and if possible, choose a relatively flat area where a spot face of about 36mm can be created. Procedure:
1. Select a mounting position, in any plane, as close as possible to the vibration source. 2. Prepare a flat, smooth, unpainted surface larger than the base of the Metris Vibe sensor
(recommended to use a wired drilling machine, 300-600rpm). 3. Drill a hole with a suitable diameter in the center of the flat area, with 10mm depth. 4. Using a suitable sized tap for the mounting option (M8x1.25) of the sensor, screw the sensor in the hole ensuring that there is at least 7mm of full thread. 5. De-burr the prepared hole and thoroughly clean the surface and the base of the stud with solvent. 6. Apply Loctite Screw lock to the thread on the METRIS VIBE sensor and smear grease on the mating surface to ensure good coupling to the METRIS VIBE sensor. 7. Screw the METRIS VIBE sensor into the threaded hole and tighten to 8Nm torque with a torque wrench WAF30. CAUTION ANDRITZ Page 15 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 It is very important to mount the sensor according the installation instruction. To download data from the sensor Blue Tooth LE is used. Therfore 2 (two) possibities are 3.3 DOWNLOADING DATA foreseen to get access to the required data. Industrial Gateway routers Data is downloaded from sensor, automatically, via industrial gateway routers. Smartphone or Tablet Data is downloaded from sensor, manually, using the METRIS VIBE mobile App. The app is available for Android and IOS. 3.4 SETTINGS METRIS VIBE SENSOR All settings have to be done via Blue Tooth LE. Therfore 2 possibities are foreseen to change the settings. Industrial Gateway routers level of a sensor. Smartphone or Tablet On the webinterface it is possible to configure the settings and also check the battery For details take a look into the manual of the industrial gateway software Via the METRIS VIBE mobile App, available for Android and IOS, it is possible to configure the settings for a given sensor. For details please check the METRIS VIBE mobile App user manual. Parameter Measurement Interval Measurement G range
(sensitivity) Sampling frequency Recording time Default value 360 min. Description This is the interval between the samples which are taken of the vibration and temperature. This is the measuring range of the vibrations sensor Rate of sampling of the vibration sensor. The frequency shown in the FFT will be the half of the sampling frequency. The duration of one vibration sample which is being measured 8g 3200Hz 640ms ANDRITZ Page 16 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 3.5 SPECIAL CONDITIONS The ambient temperature range is set from -40C to +85C. Category 1 equipment The vibration sensor may only be operated in an explosive atmosphere, which requires equipment of category 1, if atmospheric conditions exist (temperature from 20C to + 60C, pressure from 0.8 bar to 1.1 bar). NOTICE No Reparing possible If the METRIS VIBE sensor is damaged it is not possible to repair it. In this case you have to replace the sensor with a new one. 4. REPAIR ANDRITZ Page 17 of 25 March 22, 2022 Operating manual: Metris Vibe If the METRIS VIBE sensor is no longer fit for use and is to be scrapped, it must be Comply with all national, regional and local legal requirements and regulations during the disposal or recycling of parts and components of the METRIS VIBE sensor as well as of materials needed to operate it. High-quality recyclable materials like stainless steel of an adapter can be recovered by means of a scrapping process with a high recycling quota. Metris Vibe sensor has a Lithium battery encapsulated which can not be separated. Due to that reason remove this part as an electrical and electronic component. Disposal in the normal domestic waste is not Rev.: 03 5. DECOMMISSIONING decommissioned and disassembled. 5.1 DISPOSAL permitted. ANDRITZ Page 18 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 6. Version Zone 0 Zone 20 AREA OF APPLICATION Identification IBExU 19 ATEX1055 X II 1G Ex ia IIC T5 Ga IBExU 19 ATEX1055 X II 1D Ex ia IIIC T95C Da ANDRITZ Page 19 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 7. Measurement:
TECHNICAL DATA AND AMBIENT CONDITIONS Vibration: x-axis, y-axis, z-axis Temperature 10Hz - 12800Hz 100 Hz - 25600Hz Maximum 6000 samples Frequency Range:
Sampling Frequency:
Number of measured values per measurement and axis:
Sampling Time:
Sensitivity:
Data Acquisition:
Measurement interval:
Storing of Samples: Depending on the used mode there is a different amount of 100ms - 5000ms 8g, 16g, 32g 16 bit ADC User defined measurements which can be stored directly on the Metris Vibe Standard Mode (3200Hz, 640ms): 82 measurements High Frequency Mode (12800Hz, 320ms): 47 measurements High Resolution Mode (3200Hz, 1280ms): 47 measurements Ultra low power consumption processor, 32 bit Over the Air firmware update Up to 3 years, depending on the sampling settings All orientations IP69K M8 x 1.25 thread
-40C to 85C 34.6mm x 24mm 60g Ambient temperature MCU:
RF Communication: 2.4 GHz Low Power, BLE Software:
Battery life time:
Mounting orientation:
Mounting System Connection:
EN 60529 protection:
Temperature range:
Dimensions:
Weight:
Max. surface temperature:
Battery:
Max. current Nom. current Use of certain hazardous substances in electrical and electronic equipment according to 2011/65/EU ANDRITZ CR2477N, 3V, Lithium, 950mAh 10mA 0.02mA Restricted substances referred to in Article 4 (1) and maximum concentration are in tolerance Page 20 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 8. OUTLINE DRAWING ANDRITZ Page 21 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 9. RESERVED FOR DECLARATION OF CONFORMITY ANDRITZ Page 22 of 25 March 22, 2022 Rev.: 03 10. RSS standard. est NOTICE:
Operating manual: Metris Vibe FCC AND ISED INFORMATION This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage Changes or modifications made to this equipment not expressly approved by ANDRITZ may void the FCC authorization to operate this equipment. 10.1 CLASS B DIGITAL DEVICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. ANDRITZ Page 23 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 10.2 RF EXPOSURE INFORMATION ACCORDING 2.1091 / 2.1093 / KDB 447498
/ RSS-102 Radiofrequency radiation exposure Information The radiated output power of the device is below the FCC radio frequency exposure limits. Nevertheless, the device should be used in such a manner that the potential for human contact during normal operation is minimized. 10.3 USED FREQUENCE RANGE, USED MODES AND ANTENA INFORMATION 2.402 - 2.480 GHz, 40 channels of 2Mhz bandwidth each according to the BLE specification. The Bluetooth device uses the 1 Mbit/s mode, however 2 Mbit/s, S2 coded and S8 coded were Frequence range Used Modes also measured as modes during the tests. Antena information Antenna chip W3008 from PulseLarsen. 10.4 FCC ID FCC ID: 2AX58-METRISVIBE 10.5 ISED ID ISED ID: 26689-METRISVIBE 10.6 HVIN HVIN: Ex ANDRITZ Page 24 of 25 March 22, 2022 Operating manual: Metris Vibe Rev.: 03 ANDRITZ Page 25 of 25 March 22, 2022