all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 3.32 MiB | ||||
1 | Test Report | |||||||
1 | Test Report | |||||||
1 | Test Report | |||||||
1 | Test Setup Photos | |||||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Internal Photos | |||||||
1 | ID Label/Location Info | |||||||
1 | Cover Letter(s) | |||||||
1 | RF Exposure Info | |||||||
1 | Test Setup Photos | |||||||
1 | Test Report |
1 | User Manual | Users Manual | 3.32 MiB |
OWNERS MANUAL Model AC320 Baby Video Monitor Model AC327 Baby Movement Monitor, with Video Model AC337 Baby Movement Monitor, with Video WARNING Keep users guide for future reference. Please read the warnings and safety instructions carefully before assembling & using the product. Failure to follow the warnings and the instructions could result in serious injury or death or damage to the product. IMPORTANT - INTENDED USE This product is NOT intended and should NOT be used to prevent Sudden Infant Death Syndrome (SIDS). This product is NOT intended to diagnose, treat, mitigate, cure or prevent any disease or condition. This is a product to monitor the movement of healthy babies and is not a substitute for parental care. CFO_ANGE_Manuel_AC327_NA.indd 1 2018-10-31 10:45 AM This baby monitor is compliant with all relevant standards regarding electromagnetic fields and is, when handled as described in the Users Guide, safe to use WARNINGS 1. Because of the serious strangulation risk to infant & toddlers, parents & caregivers should note the following Warnings Children have STRANGLED in cords WARNING - Strangulation Hazard KEEP the Nursery Unit and adapter cords OUT of the reach of children more than 3 feet or 1 meter away NEVER use extension cords with adapters. ONLY use adapters provided This product is NOT a Toy. NEVER allow children to play with it 2. WARNING - MOVEMENT SENSOR PAD - NO ALARM Sources of vibration & movement, other than your babys, can be detected by the Sensor Pad and interfere with the performance of your Angelcare monitor The alarm will not sound if it detects movement other than your babys High sensitivity settings can pick up other sources of vibration & movement -
please read instructions on sensitivity setting to adjust accordingly Other active and older babies (toddlers) in the same room can be detected and the alarm will not sound Ensure the babys environment is FREE from any movements or vibrations when using the Sensor Pad - see below warnings 3 to 11 3. DO NOT use a crib mobile and other crib accessories that may produce movements or vibrations 4. Fans (including ceiling), washing machines, floor boards, central heating or loud music are all forms of movement and vibration and may interfere and be detected by the Sensor Pad 5. If an additional Nursery Unit is added then it must be positioned at least 6.5 feet (2 metres) minimum from Nursery Unit 1 and Sensor Pad as this could interfere with performance 6. DO NOT use with bedside crib touching parents/
carers bed as the Sensor Pad will detect your movements 7. DO NOT place the crib against a wall or skirting board as vibrations may be detected 8. Following removal of baby from the crib, some mattresses may still detect mattress movement due to it forming back into shape and alarm may not sound 9. Ensure crib is stable to eliminate any movement 2 2 10. Crib should not be placed in reaching distance of another crib or bed 11. DO NOT use other wireless devices in the same room as the monitor (including mobile phones, microwaves...). They may interfere with signal and performance 12. The Sensor Pad is made of plastic and does not permit air to circulate. Therefore, mildew build up could develop underneath the mattress in the Sensor Pad area We suggest rotating & airing /drying the mattress regularly to prevent any mildew. AVOID CONTACT WITH MOISTURE. Clean - wipe with a dry lint free cloth 13. The Sensor Pad is not suitable for use above age 24 months 14. This product cannot replace responsible adult supervision This product is designed to aid in the monitoring of your child. When using the monitor, you must still CFO_ANGE_Manuel_AC327_NA.indd 2 2018-10-31 10:45 AM E N provide the supervision necessary for the continued safety of your child Use this appliance ONLY for its intended use as described in this manual 15. The Sensor Pad is not intended to be used to determine if a child is out of the crib 16. ALWAYS be sure to immediately check on baby whenever an alarm sounds 17. Keep cords out of the reach of ANY children 18. ONLY use the chargers and power adapters provided. Do not use other types as this may damage the device and battery pack (if included in your model) 19. Adult assembly required. Keep small parts away from children when assembling 20. Follow instructions and test this monitor and its functions so you are familiar with it prior to actual use. ALWAYS be sure that both the transmitter and receiver are working properly and are within range of each other check periodically and when changing location of the Nursery Unit 21. DO NOT touch the plug contacts especially with sharp or metal objects 22. DO NOT use the baby monitor near water Care should be taken so that objects DO NOT fall onto units and that liquids are not spilled into either unit or Sensor Pad through its openings CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN DO NOT EXPOSE TO RAIN OR MOISTURE 23. Keep monitor AWAY from heat sources
(such as stoves, radiators, etc.). Heat can damage the case or electrical parts 24. ALWAYS place both the Nursery Unit and the Parent Unit on a flat solid surface in an upright position that allows for proper VENTILATION. DO NOT place on sofas, cushions, beds, etc. which may block ventilation or anywhere that would muffle the sound or interfere with the normal flow of air 25. The baby monitor can only be used between 10C and 40C (50F and 104F) WARNINGS AND SAFETY INSTRUCTIONS - BATTERY SPECIFIC 26. ALWAYS keep all batteries away from children 27. The Parent Unit battery is a replaceable Li-Ion battery. The Wireless Sensor Pad uses a replaceable Button Cell Lithium Battery. Only use the Angelcare recommended replacement battery (see Technical Specification) Danger of explosion if the wrong battery is used or if replaced incorrectly. Refer to Users Guide for correct battery installation DO NOT short circuit supply terminals 28. DO NOT mix old and new batteries and only use Angelcare recommended replacement batteries (see Technical Specification) 29. The Button Cell battery represents a small part and a choking hazard KEEP away from children!
30. Dispose of batteries responsibly according to the Users Guide 31. Exercise care in handling batteries in order not to short out the batteries with conducting materials such as rings, bracelets and keys 32. Overcharging, short circuiting, reverse charging, mutilation, or incineration of batteries must be avoided to prevent one or more of the following occurrences: release of toxic materials, release of hydrogen and/or oxygen, gas and rise in surface temperature 33. DO NOT attempt to recharge batteries provided with or identified for use with this product that are not intended to be charged The batteries may leak corrosive electrolyte or explode 34. Incorrect polarity installation of the batteries in the end product must be avoided Reverse insertion of batteries can cause charging, and that may result in leakage or explosion 35. Remove batteries from units if you store the product over 30 days because the batteries could leak and damage the product 36. Discard dead batteries as soon as possible since dead batteries are more likely to leak in a product. If a battery has leaked or vented, discard product responsibly 37. DO NOT store this product, or the batteries provided with or identified for use with this product, in high-temperature & high humidity environments and avoid direct sunlight IMPORTANT SAFETY INSTRUCTIONS 38. Sensor Pad If your crib does not have a solid, stationary, completely flat, firm surface including a spring or slat base, place a hard board between the crib base and the Sensor Pad, to ensure correct operation
(see specification on STEP 2) The Sensor Pad functions with standard crib sprung and foam mattresses and not memory foam (partial or full), hollow frame construction mattresses and water beds. Please consult Angelcare if unsure of mattress compatibility 39. This monitor uses public airwaves to transmit signals. The Parent Unit may pick up signals or interference from other nursery monitors in your area. Your monitor may even be picked up by other households. To protect your privacy, make sure both units are turned OFF when not in use 40. Power cord protection - Protect the Adapters power cord from being walked on or pinched by furniture or other items Power supply cords should be routed so that they are not likely to be walked on or pinched by items upon or against them, paying particular attention to cords and plugs, convenience receptacle, and the point where they exit from the product. The socket outlet should be installed near the equipment and should CFO_ANGE_Manuel_AC327_NA.indd 3 3 3 2018-10-31 10:45 AM E N be easily accessible. Make sure to plug the adapter to the socket outlet nearest to the equipment and that is easily accessible. To disconnect from mains, unplug the adapter 41. Only use attachments/accessories and replacement parts specified by the manufacturer. Any mounting of the product should follow the manufacturers instructions DO NOT position this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious injury to a child or adult and serious damage to the product Use ONLY the stand sold with the product Be sure replacement parts are supplied by Angelcare and have the same characteristics as original part. Unauthourised substitution may result in fire, electric shock or fire 42. Unplug this appliance during lightning storms or when not used for long periods of time 43. Servicing - DO NOT attempt to service this product yourself as opening or removing covers (except battery door) may expose you to dangerous voltage or other hazards Power Supply see Technical Specification within this guide 44. Overloading - DO NOT overload wall outlets, extension cords or integral convenience receptacles as this can result in a risk of fire or electric shock 45. Nursery Unit Antenna - The antenna used for this transmitter must be installed to provide a separation distance of at least 8 (20 cm) from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter 46. Cleaning - Disconnect all units before cleaning. DO NOT immerse any part of the monitor in water. Clean only with a dry cloth SET UP REQUIREMENTS WHATS IN THE BOX 1 Nursery Unit 2 Stand (for Nursery Unit) 3 2 x AC Adapters 4 Parent Unit 5 Lithium Ion Battery pack
(for Parent Unit) Sensor Pad (on model AC327 and AC337) CR2450 Battery (for Sensor Pad)
(on model AC327 and AC337) Hardware (for wall mounting) 6 7 8 WHAT YOU NEED Hardboard, if the crib does not have a firm surface
(see specification on STEP 2) 1 4 6 2 3 2X 5 7 8 4 CFO_ANGE_Manuel_AC327_NA.indd 4 2018-10-31 10:45 AM 1- SETTING UP THE PARENT UNIT 2 1 3 Charge the Parent Unit 8 hours prior to first use Regular charging time is 4 hours 8H 2- SETTING UP THE SENSOR PAD (ON MODEL AC327 AND AC337) 1 2 3 CFO_ANGE_Manuel_AC327_NA.indd 5 1. Remove the battery cover and insert the battery face with + face up 2. Replace the battery cover, align 2 dots and click to secure 3. Remove the mattress from the crib, place Sensor Pad
- Angelcare logo side up - on base in centre of mattress. It should be centred on the hardboard if your crib requires a hardboard support (see IMPORTANT note below) 4. Replace the mattress 5 2018-10-31 10:45 AM E N IMPORTANT If your crib does not have a solid, stationary, completely flat, firm surface including a spring or slat base, place a hardboard between the crib base and the Sensor Pad, to ensure correct operation. The hardboard support must measure at least 30 x 30 cm (12 x 12) and 6 mm (1/4) thick. This hardboard support must be larger than the Sensor Pad surface area The Sensor Pad functions with standard crib sprung and foam mattresses and not memory foam (partial or full), hollow frame construction mattresses and water beds. Please consult Angelcare if unsure of mattress compatibility. The hardboard maintains a constant pressure on the Sensor Pad, enabling it to detect the babys movements even when the baby is at the edges of the crib 3- SETTING UP THE NURSERY UNIT Place the Nursery Unit and Adapter cord at least 3 feet (1 meter) from the crib Wall-Mounted 1 2 Tabletop Sensor Pad WALL-MOUNTED 1 2 3 4 TABLETOP 1 2 6 CFO_ANGE_Manuel_AC327_NA.indd 6 2018-10-31 10:45 AM 4- TURNING ON YOUR MONITOR NURSERY UNIT PARENT UNIT Note:
Your Nursery Unit and Parent Unit come pre-paired Each time you power ON your Nursery Unit, the internal thermometer will need to calibrate to ensure accuracy. This automatic process will take approximately 30 minutes NURSERY UNIT PARENT UNIT PAUSING AND RESTARTING THE SENSOR PAD Allows you to pause the Sensor Pad if you remove baby from the crib, e.g. for feeding or comforting. Ensure to un-pause the Sensor Pad before putting baby in the crib TEST THE SENSOR PAD (ON MODEL AC327 AND AC337) 1. Sources of vibration & movement other than your babys can be detected by the Sensor Pad and interfere with the performance of your Angelcare monitor. The alarm will not sound if it detects movement other than your babys 2. There are 4 sensitivity settings. The unit is set at level 2 (default) and can be adjusted accordingly 3. The Sensor Pad will detect false movements if you are touching the crib 4. The monitor will produce a Pre-alarm single beep tone designed to stir baby if no movement has been detected for 15 seconds. If no further movement is detected, the main alarm will sound at 20 seconds SENSOR PAD FOUR CORNER TEST 1. Place the Sensor Pad at the centre of babys sleeping area and put the mattress back in place 2. Switch ON both Nursery & Parent Units 3. Place your hand in a corner of the mattress and keep it there for 20 seconds If the alarm sounds, even after placing your hand in any of the corners, adjust the sensitivity higher by a single level and repeat this test If the movement alarm does not sound, continue the below:
- Step away from the crib, after 20 seconds an alarm will sound from the Nursery and Parent Unit 4. Place your hand back onto the mattress in a different corner, the alarm will cease as movement is detected Repeat in the remaining corners If the alarm does not sound when you step away from the crib, lower sensitivity down a single level and repeat this test. If the problem persists, check for other sources of vibrations in the nursery CFO_ANGE_Manuel_AC327_NA.indd 7 7 2018-10-31 10:45 AM E N IMPORTANT Test your monitor before first use Prior to use and on a regular basis (before placing your child in the crib) always check the Sensor Pad is detecting no movements or vibrations in its environment Test your monitor every time you move the Sensor Pad to a different place 5- GETTING TO KNOW YOUR MONITOR NURSERY UNIT 1 Speaker 2 Microphone 3 Camera Lens 4 Power indicator (on model AC327 & AC320) Temperature Indicator
(on model AC337) 5 Micro USB charging port 6 Pause Sensor Pad / Pairing button 7 Power ON/OFF 8 Magnet for tabletop stand and wall mount PARENT UNIT 1 Power ON/OFF (Press & Hold)
/ Sleep mode (Quickly press & release) 2 Talk-back / Return & save settings 3 Menu 4 Zoom & pan feature / Navigate left
/ Switch Nursery Unit sound 5 Movement indicator (TIC function) 6 Power indicator 7 Visual sound indicator 8 Microphone 9 Volume up / Navigate up 10 Volume down / Navigate down 11 Navigate right / View mode 12 Rechargeable battery compartment 13 Micro USB charging port 14 Speakerphone 15 Folding stand 8 1 2 3 4 FRONT SIDE 1 2 3 4 13 6 7 REAR SIDE 5 8 6 5 7 FRONT SIDE 12 REAR SIDE 8 9 10 11 14 15 CFO_ANGE_Manuel_AC327_NA.indd 8 2018-10-31 10:45 AM TOP STATUS BAR 11 16 17 18 1 2 3 4 5 6 7 9 10 8 12 13 14 15
) 7 3 3 C A d n a 7 2 3 C A l e d o m n o
(
1 Sensor Pad movement detection is activated 2 Sensor Pad alert 3 Sensor Pad lost link 4 Sensor Pad movement detection is OFF 5 Sensor Pad is paused 6 Sensor Pad is low battery 7 Sensor Pad has never been paired 8 9 10 11 Nursery Unit selected and broadcasting sound TIC function is activated
(on model AC327 and AC337) VOX function is activated Temperature alert is activated 12 Temperature alert: too hot 13 Temperature alert: too cold 14 Night vision is activated Sensor Pad low battery 15 indicator (on model AC327 and AC337) 16 Volume level indicators 17 Reception quality indicators 18 Parent Unit battery level indicators MAIN MENU ON 1 ON 2 1 Movement Sensor Pad Activation (on model AC327 and AC337):
ON: The Parent & Nursery Units will alarm if there is no movement after 20 seconds PAUSE: Allows you to pause the Sensor Pad if you remove baby from the crib, e.g. for feeding or comforting The Pause icon in the status bar will flash On the AC327, the Nursery Unit Power indicator will slowly blink On the AC337, the Nursery Unit temperature indicator will show a pause P symbol Ensure to un-pause the Sensor Pad before putting baby in the crib (Turn movement detection ON) OFF: When your baby gets older, allows you to turn movement detection OFF and use your monitor for video only VOX OFF 3 2 3 2 4 3 MIN 5 6 7 Tic Activation (on model AC327 and AC337):
If movement detection is activated, allows you to hear a Tic sound every 5 seconds. In the event you have two Sensor Pads connected, the Tic indication will flash green for Sensor Pad 1 and blue for Sensor Pad 2 VOX Activation: Sound Activated (VOX ON) means that it will transmit sounds only when it detects them, based on the setting of the sensitivity level. To save power, after 10 seconds, the sound transmission will stop if no sound is detected. Once sound is detected transmission will automatically activate. Continuous Sound
(VOX OFF) means the sound monitoring is continuously ON, picking up all sounds 4 Screen Brightness 5 Sleep Mode Set-Up 6 Temperature Settings 7 General Settings CFO_ANGE_Manuel_AC327_NA.indd 9 9 2018-10-31 10:45 AM E N IMPORTANT To confirm your settings, youll always need to press the then appear on the screen: Settings have been saved If you have 2 Nursery Units & 2 Sensor Pads paired with your monitor, you can only change the settings of the viewing Nursery Unit button. A confirmation icon will Settings have not been saved TEMPERATURE SETTINGS MENU 72 1 60 2
C 3 OFF 4 ON 5 1 Set warmer temperature alarm 2 Set colder temperature alarm 3 Set Celsius or Fahrenheit display 4 Activate the temperature alarm 5 Activate the Nursery temperature color code display (on model AC337) White: Temperature is normal Red: Temperature is too hot Blue: Temperature is too cold GENERAL SETTINGS MENU PAIRING MENU VOX 1 2 3 4 5 1 2 3 1 2 Set VOX sensitivity: The sensitivity of the microphone is adjustable and has 4 levels
(the most sensitive is level 4). This means that sound will only transmit based on the level that you set Set Sensor Pad sensitivity
(on model AC327 & AC337):
To ensure adequate monitoring of your childs movements, you can adjust the sensitivity of the Sensor Pad 3 Set Nursery Unit speaker phone volume 4 Activate Nursery Unit display
(on model AC337) 5 Pairing Menu 1 Nursery Unit 1 Status 2 Nursery Unit 2 Status 3 Sensor Pad 1 Status (on model AC327 and AC337) Nursery Unit and Sensor Pad Status Icons:
Green: Connected/Paired Blue: Add a Nursery Unit or Sensor Pad Red: Remove Nursery Unit or Sensor Pad Confirmation process ON THE SCREEN:
Blue: Link icon animation when pairing
(Linking timeout: 60s) Green: Successful pairing Red: Failed pairing, please try again 10 CFO_ANGE_Manuel_AC327_NA.indd 10 2018-10-31 10:45 AM ALERTS ICONS 1 1 1 1 1 1 1 1 1 2 3 2 3 4 5 6 7 Sensor Pad alert: If after 20 seconds there is NO movement detected both the Parent Unit and Nursery Unit speakers will emit loud consecutive beeps - this is the movement alarm Sensor Pad is paused Sensor Pad lost link: Parent Unit and Nursery Unit speakers will emit loud consecutive beeps 4 5 6 7 Parent Unit is out-of-range: Parent Unit will emit 3 consecutive beeps, every 10 seconds Temperature is too hot: Parent Unit will emit 3 consecutive beeps, every 5 seconds Temperature is too cold: Parent Unit will emit 3 consecutive beeps, every 5 seconds Parent Unit battery is low: Parent Unit will emit 3 consecutive beeps, every 30 seconds
) 7 3 3 C A d n a 7 2 3 C A l e d o m n o
(
Note: Press any key to stop alarm and make the alert icon disappear In the case of a Sensor Pad alarm, the monitor will Pause the Sensor Pad. In Pause mode, the movement detection feature is disabled. To reactivate the Sensor Pad, simply un-pause the Sensor Pad into the first menu 6- ADDING ACCESSORIES Your Angelcare monitor allows you to add an additional Nursery Unit and Sensor Pad. Please contact your local distributor to see what is available in your country IMPORTANT:
When using two Nursery Units you will only be able to hear audio from one Nursery Unit at a time. In split screen, the sound transmitted from the Parent Unit will be from the Nursery Unit number highlighted in the info bar When using two Sensor Pads with one Monitor, it is recommended that each Sensor Pad is located in separate rooms 7- TROUBLESHOOTING TAKING CARE OF YOUR RECHARGEABLE BATTERY Ensure that you fully charge your battery for 8 hours before its first use. To maintain maximum battery life, it is recommended that you fully discharge your battery periodically. If your Parent Unit is not in use, please turn it OFF. NO SOUND IS BEING TRANSMITTED Check the volume level on the Parent Unit and the Nursery Unit to ensure they are set to an appropriate level. Try bringing the Parent Unit closer to the Nursery Unit to see if you get sound. Charge the Parent Unit. CFO_ANGE_Manuel_AC327_NA.indd 11 11 2018-10-31 10:45 AM E N WEAK RECEPTION Bring units closer together. Change the position of one or both units. Place units on a flat surface away from babys reach. Recharge the Parent Unit. STATIC, DISTORTION, INTERFERENCES (FROM OTHER MONITORS, WIRELESS PHONES, WALKIE-TALKIES, ETC.) Rotate Parent Unit or move it away from source of interference. FEEDBACK (LOUD NOISES EMITTED FROM THE PARENT UNIT) Move units further apart (at least 10 feet (3 meters)). Decrease volume on Parent Unit. THE PARENT UNIT SCREEN IS BLACK (PARENT UNIT IS OFF) Turn the Parent Unit back ON by pushing and holding the POWER ON/OFF button for 2 seconds. Recharge the Parent Unit. MOVEMENT SENSOR PAD - NO ALARM Sources of vibration & movement, other than your babys, can be detected by the Sensor Pad and the alarm will not sound. Refer to Warnings 3 to 11 and see STEP 4, TEST THE SENSOR PAD. MOVEMENT SENSOR PAD - FALSE ALARMS Replace the Sensor Pad battery CR2450. Turn OFF the Nursery Unit. Sensor Pad False alarms may happen for several reasons, always be sure to immediately check on baby whenever an alarm sounds:
- Nursery Unit has not been turned OFF after you have removed your baby from the crib
- Make sure there is no bedding between the mattress and the Sensor Pad
- Sensor Pad has not been placed under the mattress properly. Be sure the Sensor Pad is on a flat, firm surface with the printed side facing up
- The sensitivity level may also need to be adjusted Refer to Warnings 3 to 11 and see STEP 4, TEST THE SENSOR PAD NO SOUND IS BEING TRANSMITTED Check that both units are powered ON. Check that Parent Unit is not on MUTE. HOW TO CHECK THE PARENT UNIT BATTERY Unplug the adapter from the Parent Unit and check the battery level indicator. 12 CFO_ANGE_Manuel_AC327_NA.indd 12 2018-10-31 10:45 AM LOSS OF CONNECTIVITY BETWEEN THE NURSERY UNIT AND PARENT UNIT If your Nursery Unit becomes un-paired from your Parent Unit, please follow the steps below to re-pair them. 1. 2. Press Menu button 3. Turn ON the Parent Unit and keep the Nursery Unit OFF 3 VOX 4. and press It will directly jump to General setting menu. Select the Pairing Icon In the Pairing Menu, select Nursery Unit 1 Icon and press If Nursery Unit 1 is marked as connected select it to go the Nursery Unit 1 Pairing option. You will now need to remove it by selecting the red icon The linking icon will appear on the screen until Successful Pairing Icon Youll now be able to proceed with step 4 appears on the screen. 5. The Linking Icon will appear on the screen 6. Turn ON the Nursery Unit and press and hold its 7. pause/pairing button until the power LED starts blinking while pairing If the connection has been made, the Green Successful Pairing Icon and the menu will show the OK Paired Icon will appear on the screen 8. Otherwise, the Red Failed Pairing Icon on the screen. You will need to try again will appear 4 6 LOSS OF CONNECTIVITY BETWEEN THE SENSOR PAD AND THE NURSERY UNIT
(ON MODELS AC327 & AC337) If your Sensor Pad becomes un-paired from your Parent Unit, please follow the steps below to re-pair them. In order to reconnect your Sensor Pad to your Nursery Unit, you need to make sure the Nursery Unit is paired with the Parent Unit first 1. Remove the battery of the Sensor Pad Note: If you have two Sensor Pads, you will need to remove the battery from both of them first and then follow the steps below 2. Press Menu icon 3. Select the General setting menu 4. Select the Pairing Icon 5. In the Pairing Menu, select Sensor Pad 1 Icon and press and press VOX 3 MIN OFF ON ON 3 4 2 and press 6. 7. The linking icon will appear on the appears If Sensor Pad is marked as connected select it to go the the Sensor Pad Pairing option. You will now need to remove it by selecting the red icon screen until Successful Pairing Icon on the screen. Youll now be able to proceed with step 5 Insert the battery into the Sensor Pad. It will automatically activate it If the connection has been made, the Green Successful Pairing Icon will appear on the screen and the menu will show the OK Paired Icon 8. Otherwise, the Red Failed Pairing Icon will appear on the screen. You will need to try again VOX 5 6 CFO_ANGE_Manuel_AC327_NA.indd 13 13 2018-10-31 10:45 AM E N CUSTOMER CARE - LIMITED WARRANTY Angelcare warrants to the original owner of this product that Angelcare monitor is free from any material and workmanship defects for the term of the warranty period (see warranty table below to determine the warranty for your country). If this monitoring system fails to function properly when used as directed under normal conditions and during the warranty period, Angelcare will either repair or replace the product, at our discretion, free of charge. Please contact your local distributor to validate warranty and warranty period. The product must be accompanied by a proof of purchase, either a bill of sale or other proof that the monitoring system is within the warranty period. Angelcare will bear the cost of repairing or replacing the product and shipping it back to you. This warranty does not apply to a product which has been damaged as a result of improper maintenance, an accident, improper voltage supply or any other form of misuse. The warranty is also void if the owner repairs or modifies the product in any way. Angelcare is not liable 14 14 for any incidental or consequential damages with regard to this product. The warranty also excludes any liability other than what is stated above. No other warranty is given. This warranty does not cover products and accessories which are not Angelcare-branded, or any problems that result from usage that is not in accordance with product instructions, failure to follow the product instructions, or problems caused by using accessories, parts or components not supplied by Angelcare. LEGAL RIGHTS VARY FROM COUNTRY TO COUNTRY. SOME COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. WE ARE NOT IN ANY WAY RESPONSIBLE FOR ANY OUTCOME RESULTING FROM THE USE OF THIS PRODUCT. Warranty term per country North America 1 year CFO_ANGE_Manuel_AC327_NA.indd 14 2018-10-31 10:45 AM E N Federal Communications Commission (FCC) This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Industry Canada (IC) This device complies with the Industry Canada license exempt RSS standard(s):
Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. RF Exposure - This device is designed and manufactured to comply with Radio Frequency (RF) radiation exposure limits for EU, FCC and IC for an uncontrolled environment. To maintain the compliance, human exposure to the nursery unit shall not be less than 20 cm (8 inches) during normal operation. Exposition aux radiofrquences Cet appareil est conu et fabriqu pour respecter les limites dexposition aux radiofrquences (RF) de lEU, de la FCC et dIC dans un milieu non contrl. Pour maintenir cette conformit, il ne doit pas y avoir de prsence humaine moins 20 cm (8 po) de lunit du nourrisson pendant le fonctionnement normal. Go to: www.angelcarebaby.com for Full Users guide including full compliance statements. PROTECT THE ENVIRONMENT The wheelie bin symbols mean that according to local laws and regulations your product and/or its battery shall be disposed of separately from household waste. When the product/battery reaches its end of life take it to a collection point designated by local authorities. The seperate disposal and recycling will help conserve natural resources and protect human health and the environment. Refer to Users Guide for removal of batteries. TECHNICAL SPECIFICATIONS Range:
Open field (Open area without obstructions):
Between the Nursery Unit and the Parent Unit:
up to 820 feet (250 meters) Between the Nursery Unit and the Sensor Pad:
up to 20 feet (6 meters) Number of Channels:
19 channels. Thermometer Guidelines:
High Temperature Alarm: 72F (22C) Low Temperature Alarm: 60F (16C) Power Supply:
1 included Li-Ion battery 1300 mAh 3.7V (manufactured by Icon Energy System (Shenzhen) Co Ltd) for the Parent Unit 2 x 100-240 V AC / 5V DC 0.6A Adapters for the Parent Unit and the Nursery Unit 1 included CR2450 3V battery for model AC327 and AC337 (wireless Sensor Pad) Caution: To reduce the risk of electric shock, do not expose this product to rain or moisture. Danger of explosion if batteries are incorrectly replaced. The battery included for the Parent Unit is a user replaceable Li-ion rechargeable battery. Only use the Angelcare recommended replacement battery. The battery for the Sensor Pad is a user replaceable Lithium
(not Li-Ion) battery and is NOT rechargeable. To obtain information on replacement batteries please contact Angelcare customer service: www.angelcarebaby.com or contact your local distributor. Instructions will be included with the replacement battery. Keep all batteries away from children. Batteries:
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE Transmission:
Transmission between the Parent Unit and the Nursery Unit is made on 2.4 GHz frequency. Transmission between the Nursery Unit and the Sensor Pad is made on 2.4 GHz frequency for model AC327 and AC337. Maximum RF Power Transmitted:
20dBm (100mW) between Nursery Unit and Parent Unit 4dBm (2.5mW) between Nursery Unit and Sensor Pad See product for compliance marks specific to this device. CFO_ANGE_Manuel_AC327_NA.indd 15 15 15 2018-10-31 10:45 AM FCCANDICWARNING IndustryCanada(IC) Thisdevicecontainslicenseexempttransmitter(s)/receiver(s)thatcomplywith Innovation,ScienceandEconomicDevelopmentCanadaslicenseexemptRSS standard(s).Operationissubjecttothefollowingtwoconditions:(1)thisdevicemay notcauseinterference,and(2)thisdevicemustacceptanyinterference,including interferencethatmaycauseundesiredoperationofthedevice. Cet appareil contient des metteurs / rcepteurs exempts de licence conformes la norme RSS dInnovation, Sciences et Dveloppement conomique Canada. Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas causer dinterfrences et (2) cet appareil doit accepter toute interfrence, y compris les interfrences pouvant entraner un fonctionnement non souhait de lappareil. FederalCommunicationsCommission(FCC) 1.Warning:Changesormodificationstothisunitnotexpresslyapprovedbytheparty responsibleforcompliancecouldvoidtheusersauthoritytooperatetheequipment. 2.ThisdevicehasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device,pursuanttoPart15oftheFCCrules.Operationissubjecttothefollowingtwo conditions:(1)thisdevicemaynotcauseinterference,and(2)thisdevicemustaccept anyinterference,includinginterferencethatmaycauseundesiredoperationofthe device. Theselimitsaredesignedtoprovidereasonableprotectionagainstharmful interferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcan radiateradiofrequencyenergyand,ifnot installedandusedinaccordancewiththeinstructions,maycauseharmful interferencetoradiocommunications. However,thereisnoguaranteethatinterferencewillnotoccurinaparticular installation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevision Contact information IMPORTANT! This Angelcare monitor is a personal care product. Please do not return this product to the store. If you have questions or need help, please call your distributor before returning this product. We, at Angelcare, stand behind all of our products. If you are not completely satisfied or have any questions, please contact your distributor before returning this product:
United States and Canada: Please contact us at: info@angelcarebaby.com Other countries: Find your local distributor by visiting our website:
angelcarebaby.com/distributeurs TO LEARN MORE To learn more, watch the set-up videos and other functionalities on our website. https://angelcare.zendesk.com/how-to-video www.angelcarebaby.com Angelcare Monitors Inc. 201, boulevard de lIndustrie, local 104 Candiac (Quebec) J5R 6A6 Canada 8 1 0 1 0 2
-
W O R
-
7 2 3 M I CFO_ANGE_Manuel_AC327_NA.indd 16 2018-10-31 10:45 AM
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-03-26 | 2412 ~ 2468 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-03-26
|
||||
1 | Applicant's complete, legal business name |
Angelcare Monitors Inc.
|
||||
1 | FCC Registration Number (FRN) |
0006356315
|
||||
1 | Physical Address |
201 Boul. De I'industrie, Local 104
|
||||
1 |
Candiac, Quebec, N/A J5R 6A6
|
|||||
1 |
Canada
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
T******@intertek.com
|
||||
1 | TCB Scope |
A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
N7T
|
||||
1 | Equipment Product Code |
AC320T
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
R******** P******
|
||||
1 | Title |
VP Marketing
|
||||
1 | Telephone Number |
450-4********
|
||||
1 | Fax Number |
450-4********
|
||||
1 |
r******@angelcarebaby.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Intertek Testing Services Shenzhen Ltd. Longhua Br
|
||||
1 | Name |
W**** C****
|
||||
1 | Physical Address |
101, 201, Block B, No. 308 Wuhe Blvd, Zhangkengjin
|
||||
1 |
Shenzhen
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
(86 7********
|
||||
1 | Fax Number |
(86 7********
|
||||
1 |
W******@intertek.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Intertek Testing Services Shenzhen Ltd. Longhua Br
|
||||
1 | Name |
W**** C******
|
||||
1 | Physical Address |
101, 201, Block B, No. 308 Wuhe Blvd, Zhangkengjin
|
||||
1 |
Shenzhen
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
(86 7********
|
||||
1 | Fax Number |
(86 7********
|
||||
1 |
W******@intertek.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Baby Monitor -Baby Unit | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | Yes | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Intertek Testing Services Shenzhen Ltd. Longhua Br
|
||||
1 | Name |
H**** O********
|
||||
1 | Telephone Number |
+86 7********
|
||||
1 |
h******@intertek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2412.00000000 | 2468.00000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC