RF Module 2.4G User's Manual Revision 02 3/04/2011 1 TableofContents 1 2 3 4 5 6 7 8 GENERAL DESCRIPTION......................................................................................................3 DEVICE OPERATION..............................................................................................................3 DETAILED DEVICE DESCRIPTION....................................................................................3 DEVICE INSTALLATION .......................................................................................................4 DEVICE INTERFACE DESCRIPTION .................................................................................4 BATTERY INSTALLATION ...................................................................................................5 OPERATIONAL CHARACTERISTICS ................................................................................5 FCC PART 15 STATEMENT AND WARNINGS .................................................................6 2 1 General description The "RF Module 2.4G" is an end-point device of a general use wireless network application. It enables implementation of a transparent link of data transmission from a PC to any remote RS232 terminal. It also enables transmission of discrete signals to and from a PC application, The wireless network of point to multipoint topology shall include single RF Dongle 2.4G device and up to 5 RF Sensor devices. The RF Sensor is intended to any industrial use. 2 Device Operation The RF Module Sensor 2.4G device is intended for use as an end-point device in a wireless network constructed of at least on RF Dongle 2.4G device and 1 to 5 RF Module Sensor 2.4G devices. Refer also to the RF Dongle User's Manual for more information. 3 Detailed Device Description 1. Main interface connector J1 2. DC power supply Jack 3. Indication LED 4. Binding button 5. Battery housing (bottom side) 3 4 Device Installation The RF Module Sensor is equipped with 3 magnets installed on the case internal surface. These magnets provide the required mounting elements to a metal surface. The device can be mounted to any other surface by any other adequate means. It can also serve as a set-top box. To operate the device, follow the following steps:
- Set the required application cabling of the interface mating connector (see section
"Interface description" for details. Install the device at the required location.
- Connect the interface mating connector to the interface connector of the device.
- Connect the DC adapter plug to the DC jack.
- Connect the AD/DC adapter to the AC power source socket.
- The device is ready to use Set up the wireless network according to the wireless network setup user's guide. 5 Device Interface Description The following table describes the functionality of each pin of the Interface Connector J1:
Pin #
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Description Alternate analog Input #2 Analog Input #1 Signal Ground Analog Input #2 RS-232 Transmit Analog Input #3 Discrete Output #1 Discrete Input #1 Discrete Output #2 Discrete Input #2 Signal Ground Discrete Input #3 Discrete Output #3 Discrete Input #4 Function AI_2_L AI_1 GND AI_2 TX AI_3 DO_1 DI_1 DO_2 DI_2 GND DI_3 DO_3 DI_4 5V_out (through 220) 5 volt drive source for external LED DI_5 5V_out DI_6 RX DI_7 GND DI_8 Discrete Input #5 5 volt drive source for 33 (min) load. (Load current 150mA max.) Discrete Input #6 RS-232 Receive Discrete Input #7 Signal Ground Discrete Input #8 The user shall set a mating connector cabling according to the application requirement. 4 The mating connector type is:
Part Designation: B2L 3.5/22 SN OR Order No: 1747850000 Manufacturer: Weidmuller 6 Battery Installation Four (4) alkaline type batteries of size AA shall be installed at the battery housing according to the marked polarity. CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS 7 Operational Characteristics Power source:
Current Consumption:
Operating Temperature:
1) 2) 3-12 Volt DC 4 X "AA" size alkaline batteries Standby (no external load): 10uA typ. Operational (with max load): 250mA
-10 to +45 C 2400 2483 MHz Tx/Rx frequency Range:
Output Tx power:
Internal Antenna Gain:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
+5.5dBi max.
+1dBm EverysystemthatincludestheRFSENSORmodulewillhavealabel:
ThisproductincludesthemodularRFsensorFCCID:ZEMSENSOR 5 8 FCC part 15 statement and warnings NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. Warning!
Changes or modifications to this equipment not expressly approved by the Kodak IL LTD could void the users authority to operate the equipment. Warning!
This product was tested without special accessories (shielded cables and/or special connectors or other), which must be used with the unit to insure compliance. 6