Test Laboratory: UL Verification Services Inc. SAR Lab F Date/Time: 8/8/2016 4:26:16 PM SystemPerformanceCheck-D2450V2 SN 748 Frequency: 2450 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used: f = 2450 MHz; = 1.789 S/m; r = 37.956; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/11/2015
- Probe: EX3DV4 - SN3749; ConvF(6.89, 6.89, 6.89); Calibrated: 1/26/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 6.12 W/kg Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 61.743 V/m; Power Drift = -0.09 dB Peak SAR (extrapolated) = 12.2 W/kg SAR(1 g) = 5.44 W/kg; SAR(10 g) = 2.43 W/kg Maximum value of SAR (measured) = 7.86 W/kg 0 dB = 7.86 W/kg = 8.95 dBW/kg Plot No. 1 Test Laboratory: UL Verification Services Inc. SAR Lab F Date/Time: 8/8/2016 4:43:50 PM SystemPerformanceCheck-D2450V2 SN 748 Frequency: 2450 MHz; Duty Cycle: 1:1 Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Maximum value of SAR (measured) = 7.87 W/kg Plot No. 2 Test Laboratory: UL Verification Services Inc. SAR Lab H Date/Time: 8/8/2016 8:19:45 PM 20160808_SystemPerformanceCheck-D2450V2 SN 748 Frequency: 2450 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used: f = 2450 MHz; = 1.876 S/m; r = 38.05; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1357; Calibrated: 2/19/2016
- Probe: EX3DV4 - SN3989; ConvF(7.66, 7.66, 7.66); Calibrated: 2/23/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP v5.0; Type: QD000P40CD; Serial: TP:xxxx Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm Maximum value of SAR (measured) = 5.91 W/kg Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 65.315 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 11.9 W/kg SAR(1 g) = 5.41 W/kg; SAR(10 g) = 2.44 W/kg Maximum value of SAR (measured) = 7.83 W/kg 0 dB = 7.83 W/kg = 8.94 dBW/kg Plot No. 3 Test Laboratory: UL Verification Services Inc. SAR Lab H Date/Time: 8/8/2016 8:39:09 PM 20160808_SystemPerformanceCheck-D2450V2 SN 748 Frequency: 2450 MHz; Duty Cycle: 1:1 Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm Maximum value of SAR (measured) = 7.86 W/kg Plot No. 4