Test Laboratory: UL Verification Services Inc. SAR Lab F Date/Time: 8/10/2016 7:03:25 PM Wi-Fi 2.4GHz Frequency: 2437 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 2437 MHz; = 1.962 S/m; r = 51.17; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/11/2015
- Probe: EX3DV4 - SN3749; ConvF(6.88, 6.88, 6.88); Calibrated: 1/26/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1117 Rear/802.11b_ch 6 Aluminum No Band /Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.0501 W/kg Rear/802.11b_ch 6 Aluminum No Band /Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.973 V/m; Power Drift = 0.14 dB Peak SAR (extrapolated) = 0.195 W/kg SAR(1 g) = 0.031 W/kg; SAR(10 g) = 0.013 W/kg Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.0513 W/kg 0 dB = 0.0513 W/kg = -12.90 dBW/kg Plot No. 1 Test Laboratory: UL Verification Services Inc. SAR Lab F Date/Time: 8/8/2016 11:59:46 PM Wi-Fi 2.4GHz Frequency: 2437 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 2437 MHz; = 1.774 S/m; r = 37.997; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/11/2015
- Probe: EX3DV4 - SN3749; ConvF(6.89, 6.89, 6.89); Calibrated: 1/26/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;
Front /802.11b_ch 6 Aluminum Nylon /Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.228 W/kg Front /802.11b_ch 6 Aluminum Nylon /Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 11.461 V/m; Power Drift = -0.06 dB Peak SAR (extrapolated) = 0.362 W/kg SAR(1 g) = 0.167 W/kg; SAR(10 g) = 0.077 W/kg Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.244 W/kg 0 dB = 0.244 W/kg = -6.13 dBW/kg Plot No. 2 Test Laboratory: UL Verification Services Inc. SAR Lab F Date/Time: 8/9/2016 12:34:44 PM Wi-Fi 2.4GHz Frequency: 2437 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 2437 MHz; = 1.962 S/m; r = 51.17; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/11/2015
- Probe: EX3DV4 - SN3749; ConvF(6.88, 6.88, 6.88); Calibrated: 1/26/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1117 Rear/802.11b_ch 6 Mesh/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.0607 W/kg Rear/802.11b_ch 6 Mesh/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 5.578 V/m; Power Drift = 0.11 dB Peak SAR (extrapolated) = 0.153 W/kg SAR(1 g) = 0.040 W/kg; SAR(10 g) = 0.012 W/kg Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.0606 W/kg 0 dB = 0.0606 W/kg = -12.18 dBW/kg Plot No. 3 Test Laboratory: UL Verification Services Inc. SAR Lab H Date/Time: 8/9/2016 4:25:53 PM Wi-Fi 2.4GHz Frequency: 2437 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 2437 MHz; = 1.861 S/m; r = 38.063; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1357; Calibrated: 2/19/2016
- Probe: EX3DV4 - SN3989; ConvF(7.66, 7.66, 7.66); Calibrated: 2/23/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM with CRP v5.0; Type: QD000P40CD; Serial: TP:xxxx Front/802.11b_ch 6 Aluminum Mesh /Area Scan (7x7x1): Measurement grid: dx=12mm, dy=12mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.174 W/kg Front/802.11b_ch 6 Aluminum Mesh /Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 9.870 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 0.270 W/kg SAR(1 g) = 0.122 W/kg; SAR(10 g) = 0.054 W/kg Info: Interpolated medium parameters used for SAR evaluation. 0 dB = 0.174 W/kg = -7.59 dBW/kg Plot No. 4 Test Laboratory: UL Verification Services Inc. SAR Lab F Date/Time: 8/11/2016 12:56:50 AM Bluetooth Frequency: 2441 MHz; Duty Cycle: 1:1.29033; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 2441 MHz; = 1.969 S/m; r = 51.161; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/11/2015
- Probe: EX3DV4 - SN3749; ConvF(6.88, 6.88, 6.88); Calibrated: 1/26/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1117 Rear/GFSK Ch 39 Aluminum No Band /Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.0514 W/kg Rear/GFSK Ch 39 Aluminum No Band /Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.933 V/m; Power Drift = -0.11 dB Peak SAR (extrapolated) = 0.109 W/kg SAR(1 g) = 0.034 W/kg; SAR(10 g) = 0.018 W/kg Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.0502 W/kg 0 dB = 0.0502 W/kg = -12.99 dBW/kg Plot No. 5 Test Laboratory: UL Verification Services Inc. SAR Lab H Date/Time: 8/10/2016 11:26:50 PM Bluetooth Frequency: 2441 MHz; Duty Cycle: 1:1.29033; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 2441 MHz; = 1.866 S/m; r = 38.059; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1357; Calibrated: 2/19/2016
- Probe: EX3DV4 - SN3989; ConvF(7.66, 7.66, 7.66); Calibrated: 2/23/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM with CRP v5.0; Type: QD000P40CD; Serial: TP:xxxx Front/GFSK Ch 39 Aluminum Nylon/Area Scan (7x7x1): Measurement grid: dx=12mm, dy=12mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.107 W/kg Front/GFSK Ch 39 Aluminum Nylon /Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 7.536 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 0.180 W/kg SAR(1 g) = 0.078 W/kg; SAR(10 g) = 0.033 W/kg Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.114 W/kg 0 dB = 0.114 W/kg = -9.43 dBW/kg Plot No. 6