Test Laboratory: UL Verification Services Inc. SAR Lab F Date/Time: 8/11/2016 2:59:55 PM Wi-Fi 2.4GHz Frequency: 2437 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 2437 MHz; = 2.015 S/m; r = 53.508; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/11/2015
- Probe: EX3DV4 - SN3749; ConvF(6.88, 6.88, 6.88); Calibrated: 1/26/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1117 Rear/802.11b_ch 6 none/Area Scan (7x7x1): Measurement grid: dx=12mm, dy=12mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.0333 W/kg Rear/802.11b_ch 6 A27102 none/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 3.977 V/m; Power Drift = -0.12 dB Peak SAR (extrapolated) = 0.0580 W/kg SAR(1 g) = 0.015 W/kg; SAR(10 g) = 0.00512 W/kg Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.0295 W/kg 0 dB = 0.0295 W/kg = -15.30 dBW/kg Plot No. 1 Test Laboratory: UL Verification Services Inc. SAR Lab F Date/Time: 8/8/2016 11:11:23 PM Wi-Fi 2.4GHz Frequency: 2437 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 2437 MHz; = 1.774 S/m; r = 37.997; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/11/2015
- Probe: EX3DV4 - SN3749; ConvF(6.89, 6.89, 6.89); Calibrated: 1/26/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM with CRP; Type: SAM;
Front/802.11b_ch 6 Aluminum Nylon/Area Scan (7x7x1): Measurement grid: dx=12mm, dy=12mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.154 W/kg Front/802.11b_ch 6 Aluminum Nylon/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 9.381 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 0.323 W/kg SAR(1 g) = 0.137 W/kg; SAR(10 g) = 0.058 W/kg Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.202 W/kg 0 dB = 0.202 W/kg = -6.95 dBW/kg Plot No. 2 Test Laboratory: UL Verification Services Inc. SAR Lab F Date/Time: 8/9/2016 11:57:12 PM Wi-Fi 2.4GHz Frequency: 2437 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 2437 MHz; = 1.962 S/m; r = 51.17; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/11/2015
- Probe: EX3DV4 - SN3749; ConvF(6.88, 6.88, 6.88); Calibrated: 1/26/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1117 Rear/802.11b_ch 6 Aluminum Mesh/Area Scan (9x9x1): Measurement grid: dx=12mm, dy=12mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.0797 W/kg Rear/802.11b_ch 6 Aluminum Mesh/Zoom Scan (8x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 6.366 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 0.120 W/kg SAR(1 g) = 0.048 W/kg; SAR(10 g) = 0.015 W/kg Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.0758 W/kg 0 dB = 0.0758 W/kg = -11.20 dBW/kg Plot No. 3 Test Laboratory: UL Verification Services Inc. SAR Lab H Date/Time: 8/9/2016 6:01:48 PM Wi-Fi 2.4GHz Frequency: 2437 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 2437 MHz; = 1.861 S/m; r = 38.063; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1357; Calibrated: 2/19/2016
- Probe: EX3DV4 - SN3989; ConvF(7.66, 7.66, 7.66); Calibrated: 2/23/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP v5.0; Type: QD000P40CD; Serial: TP:xxxx Front/802.11b_ch 6 Aluminum Mesh /Area Scan (7x7x1): Measurement grid: dx=12mm, dy=12mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.146 W/kg Front/802.11b_ch 6 Aluminum Mesh /Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 8.894 V/m; Power Drift = 0.13 dB Peak SAR (extrapolated) = 0.525 W/kg SAR(1 g) = 0.119 W/kg; SAR(10 g) = 0.041 W/kg Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.177 W/kg 0 dB = 0.177 W/kg = -7.52 dBW/kg Plot No. 4 Test Laboratory: UL Verification Services Inc. SAR Lab H Date/Time: 8/10/2016 10:45:50 PM Bluetooth Frequency: 2441 MHz; Duty Cycle: 1:1.29033; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 2441 MHz; = 1.866 S/m; r = 38.059; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1357; Calibrated: 2/19/2016
- Probe: EX3DV4 - SN3989; ConvF(7.66, 7.66, 7.66); Calibrated: 2/23/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: SAM with CRP v5.0; Type: QD000P40CD; Serial: TP:xxxx Front/GFSK Ch 39 Aluminum Nylon /Area Scan (7x7x1): Measurement grid: dx=12mm, dy=12mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.0679 W/kg Front/GFSK Ch 39 Aluminum Nylon /Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 6.064 V/m; Power Drift = 0.13 dB
.Peak SAR (extrapolated) = 0.168 W/kg SAR(1 g) = 0.067 W/kg; SAR(10 g) = 0.028 W/kg Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.102 W/kg 0 dB = 0.102 W/kg = -9.91 dBW/kg Plot No. 5 Test Laboratory: UL Verification Services Inc. SAR Lab F Date/Time: 8/11/2016 5:40:59 PM Bluetooth Frequency: 2441 MHz; Duty Cycle: 1:1.29033; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used (interpolated): f = 2441 MHz; = 2.022 S/m; r = 53.496; = 1000 kg/m3 DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1352; Calibrated: 11/11/2015
- Probe: EX3DV4 - SN3749; ConvF(6.88, 6.88, 6.88); Calibrated: 1/26/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 (A); Type: QDOVA001BB; Serial: 1117 Rear/GFSK Ch 39 Aluminum Mesh/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.0366 W/kg Rear/GFSK Ch 39 Aluminum Mesh/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 4.364 V/m; Power Drift = -0.17 dB Peak SAR (extrapolated) = 0.0790 W/kg SAR(1 g) = 0.034 W/kg; SAR(10 g) = 0.010 W/kg Info: Interpolated medium parameters used for SAR evaluation. Maximum value of SAR (measured) = 0.0507 W/kg 0 dB = 0.0507 W/kg = -12.95 dBW/kg Plot No. 6