User Manual Contents A. Components B. H/WParts
. Both Sides
.Settings C.System Settings
. Download &Install
. How to connect with the program
.Wi-Fi Combo D.Program Settings
. Device Certification E. Application
. Start Analysis
. Full Analysis CRM Moisture Sebum Pore Melanin Acne Wrinkle Sensitivity Summary
.View Mode F. Warrantty G. FCC Notes on use 2 3 4 6 7 8 11 12 14 15 16 17 18 19 20 21 22 23 24 25 27 The images of this manual can be diVerent with the actual things. The information contained in this manual and future improvements are subject to change without notice. The latest version of the manual will be updated at the below link. http://www.aramhuvis.com/downloads 1 Contents Components Main body with skin lens (ASI100) Cradle Battery Charger USB cable Sebum paper 1 box Cleaning cloth Manual A.Components 2 H/W Parts Both Sides Moisture sensor LED light & lens Power on & oV Capture Start, Analysis, Result Modeup Mode down Battery cover USB & charger connector 3 B. H/W Parts - Both Sides H/W Parts Settings Insert the battery 1 2 3 2 Open the battery cover by pushing it leh to right with thumbs. Insert the battery and gently press the battery into place. Close the cover. 1 To turn onthe power 1 Press and hold powerbutton. 2 "Indicate LED" starts twinkling in blue light. When it stops, the device is ready to use. 1 To turn oVthe power 1 Press andhold "power" button. 2"Indicate LED" will be turned oV. B. H/W Parts -Settings 4 H/W Parts Settings Charger can be used for Amercian type & European type. The default is European type . 1 Push the plug up. 1 2 Then 220V European type is disassembled and you can see the 110V-220V American type inside of the charger. 2 3 Choose the one you want to use and connect USB cable in adaptor. 3 5 B. H/W Parts - Settings System Settings Download &Install PC User 1 Go to link on the browser as below. http://www.aramhuvis.com/downloads 2 Install the program. Tablet device or Smartphone user 1 iOS : Go to App Store and download application. 2 Android : Go to Goolgle Play Store and download it.
*Charge ASI device. It is possible to operate ASI device while charging, but it is recommended to charge the device at least an hour if the battery was totally depleted.
*The micro USB port does not support data transfer. C. System Settings - Download & Install 6 System Settings How to connect with the program 1 First of all, check the Wi-Fi name and password which is described at back side of battery cover. 2 Wi-Fi name & password must be same and the format is ASI_XXXX. 3 Turn on thedevice. 4 While turning on the device, prepare PC, Tablet, Smartphone to run the S/W. 5 Once ASI device is turned on, please go to network setting to set up the Wi-Fi connection. 6 Among Wi-Fi lists, find ASI_XXXX and select it. 7 When above code is connected, run the program Solutionist. 8 To check working properly, please check the program and see the leh below side. 9 If it is correctly set up, you can see the orange light of Wi-Fi singal. SSID: ASI_XXXX PW: XXXXXXXX 7 C. System Settings - How to connect with the program System Settings Wi-Fi Combo Wi-Fi Combo
- It means user could use device and internet at the same time.
- With this function, user can send an email aher analysis immediately. How touse?
1 The device has AP(ASI_XXXX) to be connected with the program Solutionist by Wi-Fi. 2 First of all, connect the device to AP to use it with Solutionist. 3 Run Solutionist. Wireless LAN PC/Phone /Tablet Analyzer Internet C. System Settings - Wi-Fi Combo 8 System Settings Wi-Fi Combo 1 Touch Settings. 2 In General Settings, go to Wi-Fi and touch Scan button. 3 The available Wi-FI lists appear. Amon g them, please choose the best sign al Wi-Fi to connect it. 4 During connect it, you can see the mess age saying that ASI device will be auto matically disconnected and reboot. Ple ase touch OK button. 9 C. System Settings - Wi-Fi Combo System Settings Wi-Fi Combo 1 When Wi-Fi is connected, please go to Settings page to set up the Wi-Fi c onnection. You can see now the Wi-Fi is connected. Pl ease turn it oV and connect with device AP code (ASI_XXXX). 2 The analyzer is connected with APcode. 3 Then, run Solutionist program. 4 Then go to the settings again. The selectedAP will be checked as leh. The Wi-Ficombo is done. C. System Settings - Wi-Fi Combo 10 Program Settings 1 General Settings Change the language, analysis mode and etc. 2 Analysis Settings Set up the skin type and analysis parameter. 3 Recommended Products Available for each analysis result. 4 About Check the current version and update is available in Wi-Fi connection. 11 D. Program Settings Program Settings Device Certification 1 Solutionist program includes three programs. But when you start Solutionist progra m with ASI-100 device you can see the p op message saying that the program is compatible with only SKIN device. Touch OK button. 2 Then you will see now only SKIN program i sactivated. On main menu, touch Settings. 3 Among the menu, please select Device Activation. 4 There is a device model name with serial code. Please touch Get Certification to register the device in program. D. Program Settings - Device Certification 12 Program Settings Device Certification 5 Device certification is complete. Please touch OK button. 6 When it is done, you could touch Prod uct Download button to load in serve r. 7 If you have the recommended product data in server, the product will be do wnloaded by clicking Product downl oad. If you do not have the recommended product data, you can see the message as leh image. 13 D. Program Settings - Device Certification Applicaton Start Analysis 1 Touch Analysis to start. Remote Control (Only Tablet) 1 During analysis, you can control the device in "Solutionist" program. 2 In screen, touch "Control Menu On" to activate "Remote". 3 You can make use of this function in all analysis pages. E. Application - Start Analysis 14 Applicaton CRM 1 Input the information.
- full name, email address, gender and agegroup 2 Take picture of customer's face with b uilt-in camera or use the picture you already have in device. 3 Among the customer lists, select the client to check or start analysis. 4 Check the customer information and analysis result list. 15 E. Application - CRM Applicaton Moisture 1 Press "capture" button and when you hear "
beep" sound, please put the sensor onto your skin and wait until you hear "beep"
sound again. Moisture sensor 2 The result will appear. To analyze the next step, touch the below button. E. Application - Moisture 16 Applicaton Sebum 1Put the sebum paper onto the U-zone on the cheek, then press it for 2~3 seconds. U-zone 2Place camera on the pink area and take picture. (U-zone) Sebum paper 3 Put the sebum paper onto the T-zone on face, then press it for 2 ~3 seconds. Place camera on the pink area and take picture.(T-zone) T-zone Sebum paper 4 The result will appear. To analyze the next step, touch the below button. or 17 E. Application - Sebum Applicaton Pore 1 Touch button to activate camera m ode. or 2 Put the camera onto the skin and touch button to capture the image. Then touch button to analyze it. or 3 The result will appear. Touch "Compare" button to check the sample images as 4 . To analyze the next step, touch the below button. or 4 Compare your image with 3 sample images.
- Good
- Normal
- Bad E. Application - Pore 18 Applicaton Melanin 1 Touch button to activate camera m ode. or 2 Put the camera onto the skin and touch button to capture the image. Then touch button to analyze it. or 3 The result will appear. Touch "Compare" button to check the sample images as 4 . To analyze the next step, touch the below button. or 4 Compare your image with 3 sample images.
- Good
- Normal
- Bad 19 E. Application - Melanin Applicaton Acne 1 Touch button to activate camera m ode. or 2 Put the camera onto the skin and touch button to capture the image. Then touch button to analyze it. or 3 The result will appear. Touch "Compare" button to check the sample images as 4 . To analyze the next step, touch the below button. or 4 Compare your image with 3 sample images.
- Good
- Normal
- Bad E. Application - Acne 20 Applicaton Wrinkle 1 Touch button to activate camera m ode. or 2 Put the camera onto the skin and touch button to capture the image. Then touch button to analyze it. or 3 The result will appear. Touch "Compare" button to check the sample images as 4 . To analyze the next step, touch the below button. or 4 Compare your image with 3 sample images.
- Good
- Normal
- Bad 21 E. Application - Wrinkle Applicaton Sensitivity 1 Touch button to activate camera m ode. or 2 Put the camera onto the skin and touch button to capture the image. Then touch button to analyze it. or 3 The result will appear. Touch "Compare" button to check the sample images as 4 . To check all the results, touch
"Show All Results" or the below button. or 4 Compare your image with 3 sample images.
- Good
- Normal
- Bad E. Application - Sensitivity 22 Applicaton Summary 1 Check the result. 2 Touch button or each parameter's n ame on pentagon graph. Once you select "Show Recommended Product", product image will pop up as 3 . 3 Available to check product image. 23 E. Application - Summary Applicaton View Mode 1 In view mode, it is able to take pictures with capture button in many times. 2 The user can select analysis parameter to take picture. 3 In one screen, you can see 4 diVerent images maximum. 4 The user can mark the defect or concern accordingto the image with note function. E. Application - View Mode 24 Warranty 1 The product undergoes strict quality management and inspection process before production and introduction to market. 2 In case of functional or operational defect occurring under normal condition of use within 10 days aher purchase, we will repair it for free or replace in new product. 3 When this product goes out under the normal use, we will repair it free of charge under warranty. 4 Please keep the warranty card when you ask for repair service. 5 Customer needs to pay repair charge aher warranty runs out. 6 For this product, warranty period is 14 months from the Invoice date. 7 Cost Within warranty : Sending delivery(Buyer), repair cost and returning delivery(Aram)
- If the product is broken by user's fault, repair cost could be charged. Aher warranty : Sending delivery and repair cost(Buyer), returning delivery(Aram) 8 How to send :
-As sending a present from person to person by EMS or FEDEX.
(Do not write the company name)
- Total value should be under US $99.(Write non-commercial value) 25 F. Warranty Warranty Date of purchase Contact person Address :
Tel:
Service request form
/
/
Company Product name, serial no :
Problems :
#909 Byucksan Technopia, 560, Dunchon-daero, Jungwon-gu,Seongnam-si, Shipping address:
Gyeonggi-do, 13230 Rep. Korea E-mail :support@aramhuvis.com Tel : +82 70 4687 1712 / Fax : +82 31 732 6330 F. Warranty 26 FCC FCC Compliance Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two cond itions: (1) This device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. FCC InterferenceStatement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that in terference will not occur in a particular installation. If this equipment does cause harmful interfe rence to radio or television reception, which can be determined by turning the equipment oV and o n, the user is encouraged to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit diVerent from which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCCCaution Any changes or modifications not expressly approved by the party responsible for compliance co uld void the user's authority to operate this equipment. This transmitter must not be co-located o r operating in conjunction with any other antenna or transmitter. FCC Radiation Exposure Statement IEEE 802.11b or 802.11g operation of this product in the USA is firmware-limited to channels 1 th rough 11. 27 G.FCC Memo Memo Memo HEADOFFICE Rm401~402,172, Dolma-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 13605 Rep. Korea PRODUCTION DIVISION & FACTORY
#909Byucksan Technopia, 560,Dunchon-daero, Jungwon-gu, Seongnam-si, Gyeonggi-do, 13230 Rep. Korea Tel: 070-4687-1712 / Fax: 031-732-6330 / Email: info@aramhuvis.com http://www.aramhuvis.com