Users Manual Argox Handheld Bar Code Scanner Model No.: AS-8510 USING AS-8510/8512 RADIO CRADLE The AS-8510/8512 radio cradle paired with one AS-8510/8512 scanner, builds a Cordless Reading System for the collection, decoding and transmission of barcoded data. It can be connected to a Host PC through an RS232, Keyboard wedge or USB cable and is suited for a single-cradle layout. The LEDs signal of the AS-8510/8512 radio cradle status, as described in the following:
BATTERY:
- Green LED blinking: the batter charge is in progress.
- Green LED On: the battery is completely charged. TRANSMISSION:
- Green LED On: the radio cradle is powered.
- Orange LED blinking: the radio cradle receives data and commands from the Host or the scanner. CONNECTING AND DISCONNECTING THE RADIO CARDLE INTERFACE CABLE The radio cradle can be connected to a Host by means of an RS232, Keyboard wedge or USB cable which must be simply plugged into the Host connector, placed on the base of the cradle. In addition the cradle must be connected to an external power supply. To disconnect the cable, insert a paper clip or other small similar object into the hole at the back of the cradle. Push down on the clip while unplugging the cradle. 1 Default setting For each barcode shown as below:
Read Enable 8510 8512 Checksum Verification Checksum Transmission Enable Enable Code ID Code Type UPC-A UPC-E EAN-13 EAN-8 Code-39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code-128 Code-93 Code-11 MSI/Plessey UK/Plessey Telepen Standard 2 of 5 China Post Italian Pharmacode. Code-16K PDF417 EAN UCC Composite V V V V V V V V V V V
V V two digits V One digit V V V V V V V V V V
V(8512) V(8512) V V V V
V
A E F FF
i i B
O
S i t p RC 2 ArgoScan 8510/8512 Specification Operational Light Source Model 8510 / 8512 635 nm Visible Red LED Optical System 2048 pixel CCD
(Charge-coupled device) Depth of Scan Field Up to 600mm (CODE 39, PSC=90%, Scanning Width Scan Speed Resolution 20mils) 160mm 400 scans/sec 0.1mm(4mils) Code39,PCS=90%
Print Contrast 25% or more Scanning Angle Front: 60 Rear: 60 Yaw: 70 Decode Capability Autodiscriminates all standard barcodes; Other symbologies can be ordered optionally (2D symbologies for 8512 only) Beeper Operation 7 tones or no beep Indicator Mechanical Length Width-handle Width-head Depth-handle Depth-head Green & Red led 164 mm 30 mm 78 mm 56 mm 35 mm Weight Less than 250g (with a battery) 3 Case material ABS (over molded at contact pointed) Cushion material Double injection Cradle interface RS232, Keyboard wedge, USB Electrical Input Voltage
(Cradle) Power - Operating
(Cradle) Power Standby
(Cradle) Current Operating
(Cradle) Current Standby
(Cradle) Charge Current
(Cradle) Input Voltage
(Scanner) Power - Operating
(Scanner) Power Standby
(Scanner) Current Operating
(Scanner) Current Standby
(Scanner) Light Level Shock Contaminants 5 VDC 10% VDC 5 VDC 5 VDC 132 mA 132 mA 340 mA 3.4V ~ 4.2V 3.2V ~ 4.0V 3.4V ~ 4.2V 225 mA 13 mA Up to 70000 Lux 1.5m drop onto concrete Seals to resist airborne particulate contaminants (IP42) 4 Ventilation Programming Programming method None required Manual (Reading special barcode) DOS command through RS-232, Windows configuration program characteristics Programmable Program upgrade Enabled by built-in flash memory Code type selection, check digit selection Decoding option Decoding option Transmitted character delay, Header selection, trailer selection, message suffix, good read beep tone and volume, scanner trigger selection Keyboard emulation type
(intermessage delay, keyboard type and keyboard language) Serial interface type (ACK/NAK, Xon/Xoff, RTS/CTS, good read LED control, start/stop bits) 5 Programming the AS-8510 / 8512 To program the 8510 or 8512, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented. To program each option, you must:
1. Scan the Program barcode on the parameter setting part. 2. Enter the option mode by scanning the Option Bar Code
(also on the Parameter setting part). 3. To the right of the option barcode, the necessary alphanumeric inputs are listed. Scan these alphanumeric entries from the back fold out page. To confirm above steps, you must scan the Finish barcode on the back fold out page. 4. Once you have finished programming. Scan the Exit barcode, listed on the lower right hand corner of each parameter setting part. 6 Program Program Barcode Option Bar Code Option Alphanumeric Entry Keyboard Wedge 00*
Interface RS-232 selection Wand emulation USB Keyboard/RS-232 Auto detection Reserved 01 02 03 04 05 Exit Option Barcode Back Fold Out Exit Barcode Finish barcode 7 Interface Selection This decoder built-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, wand emulation, and the latest USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. Interface selection: You can change factory interface default for other type interface. By plugging different cables, setting right interface, then the scanner will be changed to another interface. However, you must make sure which cable you need. Keyboard/RS232/UBS Auto detection: By setting this function, it will automatically select the Keyboard wedge or RS-232 or UBS interface for user. Program Option Bar Code Option Alphanumeric Keyboard Wedge RS-232 Interface selection Wand emulation Entry 00 01 02
(8110/8210/8150) 03 04*
05 USB Keyboard
/RS232/USB Auto detection Reserved 8 Exit Note:* -Default Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard Type: Select keyboard type connector of your host computer. Scanner must be selected to the appropriate host interface cable converter. Program Option Bar Code Option Alphanumeric Keyboard type Entry IBM AT, PS/2 00*
Reserved Reserved Reserved Reserved Reserved Reserved 01 02 03 04 05 06 Exit 9 Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command keyb to select the desirable keyboard layout or in WINDOWS entry Control then pops Keyboard to select country at language item. For details, please refer to your DOS or WINDOWS users manual. Keyboard Speed: By selecting, you can change output speed of scanner to match with host computer. Generally, set 00 or 01 in working high speed. If some output characters of barcode have been lost, you may need to set 05 or 06 to match your host keyboard speed. Function Key: Set Enable, scanner can output code as pressing function-key in your application program while the barcode datas contain ASCII value between 0116 to 1F16. Refer to ASCII table. Numeric Key: The Keypad has to be selected if your application program is only keypad numeric code acceptable. So, scanner will output code as press numeric keypad when it read numeric digit. (The keypad is in the right side of keyboard, and Num Lock control key is also on.) If Alt+Keypad is selected, Caps Lock and output will be independent. Program Option Bar Code Option Alphanumeric Entry 10 Keyboard layout USA Belgium Danish France Germany Italian Portuguese Spanish Swedish Switzerland UK Latin American Japanese 0-8 00*
01 02 03 04 05 06 07 08 09 10 11 12 00-08 Keyboard speed Function key 0 : high clock rate 8 : low clock rate 01*
03 *(8310/8312) Disable Enable 00 01*
Alphabetic key 00*
Numeric keypad 01 Numeric key
(Num lock state only) Alt+Keypad 02 11 Exit Keyboard wedge Caps Lock: By selecting Caps lockON or Caps lockOFF, scanner can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on. Inter-character delay: This delay is inserted after each data characters transmitted. If the transmission speed is too high, the system may not be able to receive all characters. Adjust it and try out suited delay to make system work properly. Block transmission delay: It is a delay timer between barcode data output. The feature is used to transfer continually with shorter barcode data or multi-field scanning. 12 Program Option Bar Code Option Alphanumeric Entry Caps lockON Caps lockOFF 00 01*
Disable Enable 00-99 msec 00*
01 00-99 02*
Caps lock Power-on simulation Inter-character delay 00-99 10 msec 00-99 10*
Block transmission delay Exit 13 RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII Code13 16) Flow control:
None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol. RTS/CTS-If the scanner wants to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication. If there is no replied CTS signal from the host computer after the timeout (Response Delay) duration, the scanner will issue a 5 warning beeps. Xon/Xoff- When the host computer is unable to accept data, it sends a Xoff code to inform the scanner to suspend data transmission, and Xon to continue. ACK/NAK- When the ACK/NAK protocol is used, the scanner waits for an A CK (acknowledge) or (not acknowledge) from the host computer after data transmission, and will resend in response to a NAK. Inter-character delay: It is delay time between data characters data output. It is also same as Inter-char. delay of keyboard wedge. Block transmission delay: It is a delay time between barcode data output. It is also same as Block transmission delay of keyboard wedge. Response delay: This delay is used for serial communication of the scanner to waiting for handshaking acknowledgment from the host computer. 14 Program Option Bar Code Option Alphanumeric Flow control None RTS/CTS Xon/Xoff ACK/NAK 00-99 (msec) 00-99 (10 msec) Inter-character delay Block transmission delay Entry 00*
01 02 03 00-99 00*
00-99 00*
00-99 (100 msec) 00-99 20*
Response delay Exit 15 Program Option Bar Code Option Alphanumeric Entry 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS None Odd Even 8 bits 7 bits One bit Two bits 00 01 02 03 04 05*
06 07 00*
01 02 00*
01 00*
01 Exit 16 Baud rate Parity Data bit Stop bit Scan Scanning mode:
Good-read off-The trigger button must be pressed to activate scanning. The light source of scanner stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning. Alternate -The trigger button acts as a toggle switch. Press button to activate or stop scanning. Timeout off-The trigger button must be pressed to activate scanning, and scanner stops scanning when no code is decoded after the Stand-by duration elapsed. Continue -The scanner always keeps reading, and it does not matter when trigger button is pressed or duration is elapsed. Double read timeout: If the barcode has been scanned twice, then only the first barcode will be accepted. Double confirm: If it is enabled, the scanner will require a several times successful decoding to confirm the barcode data. The more confirming times required the more inhibitive miss-reading code will be shown. If you set Double confirm, the Multi field scan Enable function wont be able to work. Global min./max. code length: Global Minimum and Maximum length can be set to qualify data entry. The length is defined as the actual barcode data length to be sent. Label with length exceeds these limits will be rejected. Make sure that the Minimum length setting is no greater than the Maximum length setting, or otherwise the labels of the symbology will not be readable. In particular, you can set the same value for both Minimum and Maximum reading length to force the f ixed length barcode decoded. The values of setting have no effect on certain symbologies with fixed length. 17 Notes 1): Please set the min/max length if you have special demand for individual barcode. 2): Include the Check sum digits if you want to set Global min/max code length. Program Option Bar Code Option Alphanumeric Good-read off Momentary Scanning mode Alternate Timeout off Continue Test only Entry 00 01*
02 03 04 05 Stand-by duration Double read timeout 01-99 (second) 00-99 06*
01-99 (10 msec) 01-99 50*
00-09 00*
00-99
(00: no double Double confirm confirm) 18 00-63 00-63 04*
Global min. code Exit length Scan Inverted image scan: Set Enabled the scanner will scan both black/white barcode with white/black background. CTS trigger: This operation enabled an external device to control scanning. The CTS trigger is controlled by apply an external trigger signal to the CTS input. When active, this signal causes scanning to begin as the scanners trigger was depressed. Power saving: Place the scanner in a idle state during idle priced to optimize power usage. Position indication: This function can indicate the specific location before scanning. You can also set up the time of indication. Program Option Bar Code Option Alphanumeric 00-63 Entry 04-63 63*
Global max.code length 19 Disable Enable Disable Enable Disable Enable 00*
01 00*
01 00*
01 Disable 00*
30 second 60 second 90 second 120 second 150 second 180 second Continue LED on LED off 01 02 03 04 05 06 07 00*
01 Exit 20 Inverted image scan CTS trigger
*7AJ*
Power saving
(For 8310/8312) Position indication
*7AL*
Stand mode selection
(For 8310/8312) Indication Power on alert: After power-on the scanner it will generate an alert signal to indicate a successful self -test. LED indication: After each successful reading, the LED above the scanner will light up to indicate a good barcode reading. Beeper indication: After each successful reading, the scanner will beep buzzer to indicate a good barcode reading, and its Beep loudness , Beep tone freq. and Beep tone duration are adjustable. Beep loudness/Beep tone freq./Beep tone duration: You can adjust Beep Loudness , Beep tone and Beep duration for a good reading upon favorite usage. 21 Program Option Bar Code Option Alphanumeric Disable Enable Disable Enable Disable Enable 00-07 Entry 00 01*
00 01*
00 01*
00-07 07*
00-99 (100Hz) 00-99 26*
00-99 (10 msec) 00-99 10*
Power on alert LED indication Beeper indication Beep loudness Beep tone freq. Beep tone duration Exit 22 UPCA Read: Format Leading Zero Data Digits
(11 Digits) Check Digit Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero. It will beep instead of reading anything when the trunc ate value is more than the barcode data digits or the value of Truncate Leading is overlapped with that of the Ending. The maximum value of truncate digits is 15. Code ID setting: Code ID setting is a character used to represent the symbol upon a succeeding reading. A Code ID setting is prefixed to the data begin or end transmitted if the feature is selected. If you want application to transmit Code ID, you must set Code ID transmission to Enable first. Refer to Code ID transmission. Insertion group selection: The scanner offer one or two insertion group for own symbology. By setting one or two digits to indicate which insertion group you want to insert. You may refer to Character insertion. Example: Group 2 set 02 or 20. Group 1 and 4 set 14 or 41. Program Option Bar Code Option Alphanumeric Entry Disable Enable 00 01*
Read 23 Disable Enable Disable Enable 0-15 0-15 00 01*
00 01*
00-15 00*
00-15 00*
00-ffH ASCII 00-ffH code
< A >*
00-44 00-44 00*
Check-sum verification Check-sum transmission Truncate leading Truncate ending Code ID setting Insert group selection Exit 24 UPCA Supplement digits: The Supplement digits barcode is the supplemental 2 or 5 characters for WPC code. Format Leading Zero Data Digits
(11 Digits) Check Digit Supplement Digits 2 or 5 or UCC / EAN 128 Truncation / Expansion: The leading 0 digits of UPCA data characters can be truncated w hen the function is enabled. Program Option Bar Code Option Alphanumeric None 2 digits Supplement digits 5 digits
(For 8110/8150/8210) UCC/EAN 128 Auto detection Entry 00*
01 02 03 04 25 None 2 digits Supplement digits 5 digits
(For 8310/8312) 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All Disable Enable None Truncate leading Truncation/
Expansion
(For 8110/8210) Truncation/
zero 00?
01 02 03 04 05 06 07 00 01*
00 01*
Expansion (For Expand to EAN13 02 8150/8310/8312) The Exit 26 UPCE Read: Format Leading Data Digits (6 Zero Digits) Check Digits Check -sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Program Option Bar Code Option Alphanumeric Disable Enable Disable Enable Entry 00 01*
00 01*
Read Check-sum verification 27 Disable Enable 0-15 0-15 00 01*
00-15 00*
00-15 00*
00-ffH ASCII code 00-ffH
< E >*
Check-sum transmission Truncate leading Truncate ending Code ID setting Exit 28 UPCE Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits:
Format Leading Zero Data Digits
(6 Digits) Check Digit Supplement Digits 2 or 5 or UCC/EAN 128 Expansion: The expansion function is used only for UPCE and EAN-8 code reading. It extends to 13-digits with 0 digits when the feature is enabled. Example: Barcode 0123654 Output: 0012360000057 UPCE-1: To enable scanner to read UPCE with leading digit 1. Program Option Bar Code Option Alphanumeri 00-44 Insert group selection Supplement digits None 2 digits 5 digits
(For 8110/8150/8210) UCC/EAN 128 Auto detection 29 c Entry 00-44 00*
00*
01 02 03 04 Supplement digits None 2 digits 5 digits
(For 8310/8312) 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All Disable Enable 00*
01 02 03 04 05 06 07 00*
01 Truncation/Expansion
(For 8110/8210) None 00*
Truncate leading 01 Truncation/Expansion zero
(For 8150/8310/8312) Expand to EAN13 02 Expand to UPCA 03 Disable Enable Disable Enable 00*
01 00*
01 30 Exit Expansion
*OAM*
UPCE-1 EAN-13 Read: Format Data Digits (12 Digits) Check Digits Check -sum verification: The checksum of EAN-13 is optional and made as the sum of the numerical value of the data digits. Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. The Program Option Bar Code Option Alphanumeric Entry 00 01*
00 01*
00 01*
Disable Enable Disable Enable Disable Enable Read Check-sum verification Check-sum transmission 31 0-15 0-15 Truncate leading Truncate ending 00-15 00*
00-15 00*
Exit 32 EAN-13 Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Supplement digits:
Format Data Digits
(12 Digits) Check Digits Supplement Digits 2 or 5 or UCC / EAN 128 ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two kinds of barcode for book and magazines. The ISBN is 10 digits with leading 978 and the ISSN is 8 digits with leading 977 of the EAN-13 symbology. Example: Barcode 9789572222720 - Output: 9572222724 Example: Barcode 9771019248004 - Output: 10192484 Program Option Bar Code Option Alphanumeric Entry 00-ffH ASCII 00-ffH code
< F >*
00-44 00*
00-44 33 Code ID setting Insert group selection 00*
01 02 03 04 00*
01 02 03 04 05 06 07 00*
01 Exit Supplement digits None 2 digits 5 digits
(For 8110/8150/8210) UCC/EAN 128 Auto detection None 2 digits 5 digits Supplement digits
(For 8310/8312) 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All Disable Enable 34 ISBN/ISSN conversion EAN-8 Read: Format Data Digits
(7 Digits) Check Digits Check -sum verification: The checksum of EAN-8 is optional and made as the sum of the numerical value of the data digits. Check -sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Disable Enable Disable Enable Entry 00 01*
00 01*
Read Check-sum verification 35 Disable Enable 0-15 0-15 00 01*
00-15 00*
00-15 00*
Two characters 00-ffH, 00-ffH 00-ffH ASCII
< FF >*
code 00-44 00-44 00*
Check-sum transmission Truncate leading Truncate ending Code ID setting Insert group selection Exit 36 EAN-8 Supplement digits: Format Data Digits
(7 Digits) Check Digits Supplement Digits 2 or 5 or UCC/EAN 128 Truncation / Expansion: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE. Program Option Bar Code Option Alphanumeric Entry Supplement digits None 2 digits 5 digits
(For 8110/
8150/8210) UCC/EAN 128 Auto detection Supplement digits None 2 digits 5 digits
(For 8310/8312) 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All 37 00*
01 02 03 04 00*
01 02 03 04 05 06 07 Disable Enable 00*
01 None 00*
Truncate leading 01 zero Expand to EAN13 02 Disable Enable 00*
01 Truncation /
Expansion
(For 8110/8210) Truncation /
Expansion
(For 8150
/8310/8312) Expansion Exit 38 Code 39 Read: Format Start Data Digits
( Variable) Checksum
(Optional) End Check -sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check -sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is zero, the Global Min./Max. Code Length is in effect. The length is defined as to the actual barcode data length to be sent. Label with length exceeds these limits will be rejected. Make sure that the Minimum length setting is no greater than the Maximum length setting, or otherwise all the labels of the symbology will not be readable. In particular, you can see the same value for both Minimum and Maximum reading length to force the fixed length barcode decoded. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Option Bar Code Program Option Alphanumeric Entry 00-64 00*
00-64 Max. code length 39 Read Check-sum verification Check-sum transmission Min. code length Truncate leading Truncate ending Code ID setting Disable Enable Disable Enable Disable Enable 00-64 0-20 0-15 00-ffH ASCII code 00 01*
00*
01 00*
01 00-64 00*
00-20 00*
00-15 00*
00-ffH
40 Exit Code 39 Insertion group selection: Refer to Insertion group selection of UPCA. Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +,
%, $ and/ with one of the alpha digits (A to Z). Append: This function allows several symbols to be concatenates and be treat as one single data entry. The scanner will not transmit the embedded appending code
(space for Code-39). If Enable and other symbols were read again with the appended code, then codes will be transmitted without Code ID, Preamble and Prefix. When a symbol was decoded without the appended code, the data will be transmitted without Code ID and Prefix, but the Postamble Suffix codes are appended. This function is used when the first number of code 39 is a space. Example: 123456. Start/end transmission: The start and end characters of Code-39 are . You can transmit all data digits including two
. Program Option Bar Code Option Alphanumeric Entry 00-44 00*
00-44 41 Insert group selection Standard Full ASCII Disable Enable Disable Enable 00*
01 00*
01 00*
01 Format Append Start/end transmission Exit 42 Interleaved 2 of 5 Read: Format Data Digits
(Variable) Checksum
(Optional) Check -sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check -sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Disable Enable Disable Enable Entry 00 01*
00*
01 Read Check-sum verification 43 Disable Enable 00-64 00-64 0-15 0-15 00-ffH ASCII code 00-44 Check-sum transmission Max. code leading Min. code leading Truncate leading Truncate ending Code ID setting Insert group selection 00*
01 00-64 00*
00-64 00*
00-15 00*
00-15 00*
00-ffH
< i >*
00-44 00*
Exit 44 Industrial 2 of 5 Read: Format Data Digits
(Variable) Checksum
(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry 00*
01 00-64 00*
00-64 00*
Read Max. code length Disable Enable 00-64 00-64 Min. code length 45 0-15 0-15 00-ffH ASCII code 00-44 00-15 00*
00-15 00*
00-ffH
< i >*
00-44 00*
Truncate leading Truncate ending Code ID setting Insert group selection Exit 46 Matrix 2 of 5 Eur Read: Format Data Digits
(Variable) Checksum
(Optional) Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry 00*
01 00*
01 Disable Enable Disable Enable Read Checksum Verification 47 Checksum Transmission Max. code length Min. code length Truncate leading Truncate ending Code ID setting Insert group selection Disable Enable 00-64 00-64 0-15 0-15 00*
01 00-64 00*
00-64 00*
00-15 00*
00-15 00*
00-ffH ASCII 00-ffH code 00-44
< B >*
00- 44 00*
48 Exit Codabar Read: Format Start Data Digits (Variable) Checksum (Optional) End Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Program Option Bar Code Option Alphanumeric Entry Disable 00* (8150/8210 Enable Disable Enable
/8310/8312) 01* (8110) 00*
01 49 Read Checksum Verification 00*
01 00-64 00*
00-64 00*
00-15 00*
00-15 00*
Checksum Transmission Disable Enable 00-64 00-64 0-15 0-15 Max. code length Min. code length Truncate leading Truncate ending Code ID setting 00-ffH ASCII 00-ffH code
Exit 50 Codabar Insertion group selection: Refer to Insertion group selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you may select one pair to match your application. Start/End Transmission: Refer to Start/End Transmission of Code 39. Program Option Bar Code Option Alphanumeric 00-44 Entry 00-44 00*
ABCD/ABCD 00*
abcd/abcd ABCD/TN*E Abcd/tn*e Disable Enable 01 02 03 00*
01 51 Exit Insert group selection Start/End type Start/End transmission Code-128 Read: Format Data Digits
(Variable) Checksum
(Optional) Checksum Verification: The checksum is made as the sum module 103 of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Program Option Bar Code Option Alphanumeric Disable Enable Disable Enable Disable Enable Entry 00 01*
00 01*
00*
01 Exit 52 Read Checksum Verification Checksum Transmission Code-128 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Format: The Code-128 can be translated to UCC/EAN-128 format if it starts with FNC1 character. The first FNC1 will be translated to ]C1,and next to be a field separator code as
<GS>(1D16).
]C1 Data
<GS> Data Checksum Program Option Bar Code Option Alphanumeric Entry 00-64 00*
00-64 00*
00-64 00-64 Max. code length Min. code length 53 0-15 0-15 00-15 00*
00-15 00*
00-ffH ASCII 00-ffH code
00-44 00-44 00*
Truncate leading Truncate ending Code ID setting Insert group selection Standard 00*
UCC/EAN-128 01 Format Exit 54 Code-128 Append: When the function is enabled, it won't show the data immediately if scanner read the barcode includes FNC2 code. It will show all data until it read the barcode, which doesn't have FNC2 code. UCC/ EAN 128 ID setting: To setting the code ID for UCC/EAN-128 output format. Field separator code: This feature is only used for UCC/EAN-128 format. This Field separator code means you can reassign second or after a FNC1 for your usage. The default of ASCII code is <GS>(1D16). Program Option Bar Code Option Alphanumeric Disable Enable Entry 00*
01 00-ffH ASCII 00-ffH code
00-ffH ASCII 00-ffH code 1DH*
Exit 55 Append UCC/EAN-128 ID setting Field separator code Code-93 Read: Format Data Digits
(Variable) Checksum1
(Optional) Checksum2
(Optional) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Program Option Bar Code Option Alphanumeric Disable Enable Disable Enable
(two digits) Disable Enable Entry 00*
01 00 01*
00*
01 Exit 56 Read Checksum Verification Checksum Transmission Code-93 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry 00-64 00*
00-64 00*
00-15 00*
00-15 00*
00-64 Max. code length 00-64 Min. code length Truncate leading Truncate ending 0-15 0-15 57 00-ffH ASCII 00-ffH code 00-44 Code ID setting Insert group selection
00-44 00*
Exit 58 Code-11 Read: Format Data Digits
(Variable) Checksum1
(Optional) Checksum2
(Optional) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry 00*
01 00 01*
02 Disable Enable Disable One digit Two digits 59 Read Checksum Verification Disable Enable 00-64 00-64 0-15 0-15 00*
01 00-64 00*
00-64 00*
00-15 00*
00-15 00*
00-ffH ASCII code 00-ffH
< O >*
Checksum Transmission Max. code length Min. code length Truncate leading Truncate ending Code ID setting 00-44 00-44 00*
60 Exit Insert group selection MSI/plessey Read: Format Data Digits
(Variable) Checksum1
(Optional) Checksum2
(Optional) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Disable Enable Disable Mod 10 Entry 00*
01 00* (8110) 01* (8150/8210
/8310/8312) Mod 10/10 02 Read Checksum Verification 61 Mod 11/10 Disable Enable 03 00*
01 Checksum Transmission 00-64 Max. code length 00-64 00*
00-64 00*
00-15 00*
00-15 00*
00-64 0-15 0-15 Min. code length Truncate leading Truncate ending Code ID setting Insert group selection 00-ffH ASCII 00-ffH code
00-44 00-44 00*
62 Exit UK/plessey Read: Format Data Digits
(Variable) Checksum1+2
(Optional) Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and chec ksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Disable Enable Disable Enable Entry 00*
01 00 01*
Read Checksum Verification 63 00*
01 00-64 00*
00-64 00*
00-15 00*
00-15 00*
Checksum Transmission Disable Enable 00-64 00-64 0-15 0-15 Max. code length Min. code length Truncate leading Truncate ending Code ID setting Insert group selection 00-ffH ASCII 00-ffH code 00-44
00-44 00*
64 Exit Telepen Read: IATA (International Air Transport Association). Checksum Verification: The checksum is presented as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry 00*
01 00*
01 00*
01 Disable Enable Disable Enable Disable Enable 65 Read Checksum Verification Checksum Transmission 00-64 00*
00-64 00*
00-15 00*
00-15 00*
00-64 Max. code length 00-64 0-15 0-15 Min. code length Truncate leading Truncate ending Code ID setting Insert group selection Format 00-ffH ASCII code 00-ffH
< S >*
00-44 00-44 00*
Numeric only Full ASCII only 00*
01 Exit 66 Standard 2 of 5 Read: Format Data Digits
(Variable) Checksum1
(Optional) Check -sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check -sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Disable Enable Disable Enable Entry 00*
01 00*
01 Read
*JAB*
Check-sum verification 67
*JAC*
Check-sum transmission Max. code length Min. code length Truncate leading Truncate ending Code ID setting Insert group selection Disable Enable 00-64 00-64 0-15 0-15 00*
01 00-64 00*
00-64 00*
00-15 00*
00-15 00*
00-ffH ASCII code 00-ffH
< i >*
00-44 00-44 00*
68 Exit China Post Read: Format Data Digits
(Variable) Checksum1
(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Read Max. code length Disable Enable 00-64 00-64 Min. code length 69 Entry 00*
01 00-64 11*
00-64 11*
Truncate leading Truncate ending Code ID setting 0-15 0-15 00-ffH ASCII code 00-44 Insert group selection 00-15 00*
00-15 00*
00-ffH
< t >*
01-44 00*
Exit 70 Italian Pharmacode Read: Format Data Digits
(Variable) Checksum1
(Optional) Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Leading A: If this function is enabled, each prefix of data shall be A. Program Option Bar Code Option Alphanumeric Entry 00*
01 00-64 12*
Read Disable Enable 00-64 Max. code length 71 Min. code length Truncate leading Truncate ending Code ID setting Insert group selection Leading A 00-64 0-15 0-15 00-64 09*
00-15 00*
00-15 00*
00-ffH ASCII code 01-ffH
< p >*
00-44 00*
00*
01 Exit 00-44 Disable Enable 72 Code-16K Only the 8210 / 8312 can decode Code-16K. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Read Truncate leading Truncate ending Code ID setting Insert group selection Disable Enable 0-15 0-15 Entry 00*
01 00-15 00*
00-15 00*
00-ffH ASCII 00-ffH code
00-44 73 00-44 00*
Exit PDF-417 Only the 8512 can decode PDF-417. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Program Option Bar Code Option Alphanumeric Disable Enable 0-15 0-15 Read Truncate leading Truncate ending Entry 00 01*
00-15 00*
00-15 00*
Exit 74 PDF-417 Only the 8512 can decode PDF-417. Code Id setting: Refer to Code ID setting of UPCA. Insertion group selection: Refer to Insertion group selection of UPCA. Program Option Bar Code Option Alphanumeric Entry 00-ffH
00-44 00*
00*
01 Exit 00-ffH ASCII code Code ID setting Insert group selection
*QAJ*
00-44 Disable Enable Escape sequence transmit 75 String setting Prefix characters: Up to 22 ASCII characters may be sent before data digits. Prefix Data Digits Suffix Suffix characters: Up to 22 ASCII characters may be sent after data digits. Option Bar Code Prefix characters setting Suffix characters setting Program Option None Alphanumeric Entry 00*
1-22 characters 00-ffH ASCII code 0D*
None 1-22 characters 00-ffH ASCII code Exit 76 String setting Preamble/ Postamble characters: They are appended to the data automatically when each barcode is decoded. Example:
Add a prefix/suffix or preamble/postamble for all symbologies. In this example, you are sending a $ symbol as a prefix for all symbologies. Steps:
1) Scan Programming and Prefix characters setting barcode. 2) Use the ASCII code table to find the value of $ 24. 3) Scan 2 and 4 from the barcode on the fold out back page. 4) Scan Finish from the barcode on the fold out page. 5) Scan Exit barcode. Insert G1/G2/G3/G4 character setting: The scanner offer 4 positions and 4 characters to insert among the symbol. Example: Barcode 1 2 3 4 5 6. Output- Barcode 1 2 A B 3 4 C D 5 6. Steps:
1) Scan Programming and Insert G1 characters setting barcode. 2) Use the ASCII code table to find the value of A 41,B 42. 3) Scan 4, 1 and 4, 2 from the barcode on the fold out back page. 4) Scan Finish from the barcode on the fold out page. 5) Repeat the same procedure in Insert G2 characters setting. 6) Scan Exit barcode. 7) Insert data group 1-4 position. Please refer to Chapter-
Transmission, page 65 and in specific barcode that you want to use. Program Option Bar Code Option Alphanumeric Entry 77 None 00*
1-22 characters 00-ffH ASCII Preamble characters setting None code 00*
Postamble characters setting 1-22 characters 00-ffH ASCII code 00*
None 1-22 characters 00-ffH ASCII Insert G1 characters setting None code 00*
1-22 characters 00-ffH ASCII Insert G2 characters setting None code 00*
1-22 characters 00-ffH ASCII Insert G3 characters setting None code 00*
1-22 characters 00-ffH ASCII Insert G4 characters code setting 78 Exit Transmission Preamble transmission: By setting Enable, Preamble will be appended before the data transmitted. Postamble transmission: By setting Enable, Postamble will be appended after the data is transmitted. Insert data group 1-4 position: The scanner offers 4 positions to insert among the symbol. The position default value is 00 to indicate no character insertion. Beside, make sure insertion positions are not greater than the symbols;
otherwise the insertion data is not effective. Code ID position: Upon your usage, the transmitting position of Code ID can be selected to place Before Code Data or After Code Data when it is transmitted. Program Option Bar Code Option Alphanumeric Entry 00*
01 00*
01 Disable Enable Disable Enable Preamble transmission Postamble transmission 79 00-63
(00: no insertion) 00-63 00*
00-63
(00: no insertion) 00-63 00*
00-63
(00: no insertion) 00-63 00*
00-63
(00: no insertion) 00-63 00*
Insert data group 1 position Insert data group 2 position Insert data group 3 position Insert data group 4 position Before code data 00*
After code data 01 Code ID position Exit 80 Transmission Code ID transmission: If your application is needed to transmit Code ID, you must set this to Proprietary ID or AIM ID. Code length transmission: A number of data digits can be transmitted before the code data when Enable is selected. The total length of the barcode is the number of barcode data except Truncate Leading/Ending Digits. And the length is a number with two digits. Code name transmission: This function is to show unknown barcode symbologies that include all readable symbologies of the scanner. When Enable is selected, Code Name will be transmitted before code data, you will know what kind of barcode symbology is. Case conversion: Under the barcode, you can set the alphabet in either upper case or lower case. Program Option Bar Code Option Alphanumeric Disable Proprietary ID Code ID AIM ID transmission Entry 00*
01 02 81 00*
01 00*
01 00*
01 02 Code length transmission Code name transmission Disable Enable Disable Enable Disable Upper case Case conversion Lower case
*For barcode data only Format of barcode data transmission:
Exit Prefix Name Preamble ID Code Barcode Length data ID Postamble Suffix Insert groups 82 Test Chart CODABAR-PARA CODE-11 PARA CODE-128 PARA CODE-39 PARA CODE-93 PARA EAN-13 PARA 83 PDF-417 STANDRAD-25 PARA CODE-16K 87549 EAN-8 PARA INDUSTRIAL-25 PARA UPCE PARA 84 INTERLEAVED-25 PARA MATRIX 25 PARA MSI/PLESSEY PARA UPCA PARA UK/PLESSEY PARA RSS Micro-PDF 85 ASCII Code Table Note:
For keyboard wedge only. 1 0 L H 0 1 2 3 4 5 6 7 8 9 A B C D E F L H 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 Null Up Down Left Right PgUp PgDn Bs Tab Home End Enter Insert Delete 2 SP
1 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Esc F11 F12 Ctrl+
Alt+
4
A B C D E F G H I J K L M N O 86 3 0 1 2 3 4 5 6 7 8 9
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI 5 P Q R S T U V W X Y Z
_ 6
a b c d e f g h i j k l m n o DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 7 p q r s t u v w x y z
DEL Parameter Setting List Program Barcode standard parameter setting list If you wish to display the current configuration of your AS-8110/8150/8210/8310, scanner over the host terminal/computer, scan the Barcode standard parameter setting list bar code. Unique parameter list If you wish to display the unique parameter setting list, scan the unique parameter list bar code System parameter setting list If you wish to display the product information and revision number for your AS-8110/8150/8210/8310 scanner over the host terminal/computer, scan the System parameter setting list bar code. String setting list If you wish to display the string format list, scan the String setting list bar code. 87 Firmware version list If you wish to display the firmware version, scan the Firmware version list. WARNING: Default value initialization If you wish to return the AS-8110/8150/8210/8310 to all the factory default settings, scan the Default value initialization bar code. Exit 88 0 1 2 3 4 5 6 7 8 9 A B C D E F Finish 89 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications (including the antennas) made to this device that are not expressly approved by the manufacturer may void the users authority to operate the equipment. This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the 90 following measures:
---Reorient or relocate the receiving antenna.
---Increase the separation between the equipment and receiver.
---Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
---Consult the dealer or an experienced radio/TV technician for help. RF Exposure Statement For cradle This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. For scanner This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 91 OPERATION MANUAL Interface: Please link the applicable interface cable to the PC and the Cradle POWER: plug in via the Cradle (First link the interface cable to the PC and the Cradle, then switch on the Cradle) Application: Receiving the code by using the subsidiary application pattern terminating machine (38400-N-8-1). Connection: After the Scanner Scan the code on the Test Chart, it will then implement the connection of the Cradle. In the meantime, Scanner: The yellow light glitter means on line. After connected, it will beep three times. Afterwards, it will deliver the code to the PC. If the transmission failed, the red light will be on and beep twice meaning failed. Cradle: Before linking with the Scanner, the yellow light in on. After linked, the light will turn green. 92 CHARGE:
Put the Scanner on the Cradle to charge. The green light is glitter while in charge. After completed charging the light will stay green. A PARAMETER:
Please refer to the way of parameter Cradle Power LED The yellow light on The green light on settlement. Table 1: Cradle LED status Unlink Linking Busy receiving data The yellow light glitter The green light glitter Into parameter mode Not in charge In charging Completing charging Cradle charger LED LED off The green light glitter The green light glitter 93 Table 2: Scanner LED status Scanner not working On line
Scanner LED Beep LED Off
(Sleep mode) The yellow light glittering The green light glittering
One short beep One short and one long beeps The red light glittering Data deliver success Data deliver failed Scanner low pressure warning while scanning 94 B [j\v]pS qC\vzkWw QG g{XC\vgWq q B o Wv Q|
C\vgWqovTwzZ XkqH A Y C eXkqH
\vgWqXkqH u~
Z C B qigq]z F go{zZ{H A LzZo~
A qHWw@~LuqH G A Dg\i A
C C C 95
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2005-03-11 | 2402 ~ 2480 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2005-03-11
|
||||
1 | Applicant's complete, legal business name |
Argox Information Co Ltd
|
||||
1 | FCC Registration Number (FRN) |
0018544171
|
||||
1 | Physical Address |
7F, No 126, Lane 235,Pao Chung Road
|
||||
1 |
Hsin Tien, Taipei, N/A
|
|||||
1 |
Taiwan
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
M******@CCSEMC.COM
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
NBF
|
||||
1 | Equipment Product Code |
AS-8510-B
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
R****** C********
|
||||
1 | Title |
Program Manager
|
||||
1 | Telephone Number |
886-2******** Extension:
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
R******@argox.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Handheld Bar Code Scanner (Cradle) | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | Yes | ||||
1 | Grant Comments | Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Compliance Certification Services Inc.
|
||||
1 | Name |
K**** C********
|
||||
1 | Telephone Number |
886-2********
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
k******@ccsemc.com.tw
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 | 0.0008300 |