Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point (Outdoor) Copyright Askey, INC. All rights reserved. Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point Copyright Notice This document is protected by USA copyright laws and other laws. Besides, the document is the property of Askey, INC. You may not copy, reproduce, distribute, publish, display, perform, or modify any part of this publication in any form or by any means without prior written permission from Askey, INC. You may not alter or remove any copyright or other notice from copies of the content. All other brand and product names are claimed or registered marks of their respective companies or organizations. All rights reserved. To download up-to-date version, please visit www.askey.com.tw. Copyright Askey, INC. All rights reserved. Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point FCC CAUTION This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible. This device is restricted to outdoor use when operated in the 5.15 to 5.25GHz and 5.725 to 5.825GHz frequency range. FCC requires this product to be used indoors for the frequency range 5.15 to 5.25GHz and 5.725 to 5.825GHz to reduce the potential for harmful interference to co-channel Mobile Satellite systems. IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 21cm between the radiator &
your body. Copyright Askey, INC. All rights reserved. Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point Taiwan NCC Statement
(1)
(2)
(3)
(4)
(5)
(6)
(7) MPE : MPE 1mW/cm2 0.57194 mW/cm2 21cm Copyright Askey, INC. All rights reserved. Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point Introduction EAO2001S(RoHS) can be installed by wall-mounted installation kit in any occasion, EAO2001S(RoHS) provide IP67 waterproof, dustproof metal cabinet design, can be against Taiwan's outdoor environment and climate conditions, even if long-term outdoors, high and low temperature environment can operate EAO2001S(RoHS) Copyright Askey, INC. All rights reserved. 1. LED Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point 1 RUN/ALARM_LED An LED indicator to show the system status 2 2.4G_LED 3 5G_LED 4 WAN_LED I/O Port An LED indicator to show the 2.4G status An LED indicator to show the 5G status An LED indicator to show the internet connection status 1 2 3 4 N-type Connector Console Reset For connecting to an antenna (RF Card A x 3, RF Card B x 3) Utilize all connectors for optimized MIMO performance. Console port for debugging Press once to restart the system; to reset the system to factory default settings, hold for more than 5 seconds. LAN
(Uplink (PoE) Port) Offers uplink connection. This port can be used to connect to a controller, gateway, or directly to the Internet. 802.3at PoE is also supported Copyright Askey, INC. All rights reserved. 2. Connecting Askey EAO2001S(RoHS) to Internet Access device 1. Connect the Ethernet to PoE injector. Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point 2. Plug PoE Injector on. 3. Make sure the RUN/ALARM LED is on. Copyright Askey, INC. All rights reserved. 3. Askey EAO2001S(RoHS) setup for Windows PC. 1. Plug in RJ45 cable from your PC to the PoE Injector Ethernet port. Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point 2. From PC and start browser, e.g. Microsoft Edge. 3. Open Microsoft Edge and fill in IP address e.g. http://192.168.1.1 in the URL. This default EAO2001S(RoHS) IP address is 192.168.1.1 Copyright Askey, INC. All rights reserved. 4. Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point 4. Pop up authorization required username and password. Default username is admin and password is admin, then click login button. 5. Enter EAO2001S(RoHS) system overview status page. Copyright Askey, INC. All rights reserved. 5. 6. Change Wireless settings, please click wireless item then select general page. Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point Copyright Askey, INC. All rights reserved. 6. Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point 7. Home > Wireless > General Settings > Setup wireless mode, channel bandwidth and wireless channel. 8. Home > Wireless > VAP Configuration > Change Wireless SSID. Copyright Askey, INC. All rights reserved. 7. 9. Home > Wireless > Security Settings > Setup wireless security. Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point 10. I/O port design. One RJ45 (not shielding acts WAN/POE) IEEE 802.3u 10/100/1000 Base-T auto-sensing and auto-crossover Ethernet connection. Antenna connector N type. RJ-11 Port for Console. Reset button.( Press and hold for five seconds to return to the factory settings. ) 11. Power:
PoE Input: 48V, 0.53A. 12. Environment specification Operating Temperature: -40 ~ 60 (outdoor without heater) Storage Temperature: -40 ~ 85 Operating Humidity: 10 ~ 90% RH Water-proof level: IP67 Storage Humidity: 5 ~ 95% RH 13. Ground potential rise It should be noted that when the fault is cleared, it is possible that the hazardous voltage remains and may be touched for a longer period of time than the indoor equipment, so that special grounding conditions may be required. The relevant regulations are generally specified in the electrical code. Check the installation instructions to check their compliance. Copyright Askey, INC. All rights reserved. 8. 14. Safety Warning Quick Installation Guide EAO2001S(RoHS) Enterprise Access Point The equipment must be installed and set up by professional engineers, was set to use, and shall not be sold directly to the general consumer. 15. Remind the AP shall be suitable connection with ground before installation. 16. Caution: Use PoE connection shall be extended from indoor environment. 17. The setup diagram would reference below:
It is strongly recommended to make a backup copy of your configuration settings. This device is only allowed for outdoor use purpose. For further configuration and backup information, please refer to the Users Manual. Copyright Askey, INC. All rights reserved. 9.