PadScanDS3 Usermanual Productname: BladderScanner Trademark:AvantSonic Model:PadScanDS3 AvantsonicTechnologyCo.,Ltd i PadScanDS3 TableofContents CHAPTERONE INTRODUCTION ..................................................................................................................................1 1.1BRIEFINTRODUCTION............................................................................................................................................1 1.2INTENDEDUSE.......................................................................................................................................................2 1.3STANDARDS...........................................................................................................................................................2 1.4SERVICELIFE..........................................................................................................................................................3 1.5OPERATIONALENVIRONMENT...............................................................................................................................4 1.6DECLARATIONOFELECTROMAGNETICCOMPATIBILITY............................................................................................4 1.7DECLARATIONOFMANUFACTURER........................................................................................................................5 1.8CONTRAINDICATIONS.............................................................................................................................................5 1.9HEATANDMECHANICALINDEXES...........................................................................................................................5 CHAPTERTWO CAUTIONS ANDWARNING................................................................................................................6 2.1EQUIPMENTCHECKS..............................................................................................................................................6 2.2SECURITYPREPARATIONSBEFOREOPERATION.......................................................................................................6 2.3OPERATIONINSTRUCTION......................................................................................................................................6 2.4POSTSCANCHECKS................................................................................................................................................6 2.5CONDITIONSTOAVOID..........................................................................................................................................7 2.6 NOTICEOFUSINGPROBE.................................................................................................................................7 2.7HANDLINGTHEEQUIPMENT...................................................................................................................................7 2.8INCASEOFEQUIPMENTFAILURE............................................................................................................................7 2.9MAINTENANCEOFEQUIPMENT..............................................................................................................................8 2.10MAINTAINEQUIPMENTANDPROBESAFETY.........................................................................................................8 2.11STARTINGUP........................................................................................................................................................8 AvantsonicTechnologyCo.,Ltd ii PadScanDS3 CHAPTERTHREE DEVICE INTRODUCTION...................................................................................................................9 3.1FIGURATION...........................................................................................................................................................9 3.2TECHNICALSPECIFICATION...................................................................................................................................10 3.3BLOCKDIAGRAM..................................................................................................................................................11 3.4BASICPRINCIPLE..................................................................................................................................................12 3.5EQUIPMENTCONFIGURATION..............................................................................................................................13 CHAPTERFOUR DEVICE INSTALLATION....................................................................................................................14 4.1UNPACKING.........................................................................................................................................................14 4.2INSTALLATION......................................................................................................................................................14 4.3POWERSUPPLY....................................................................................................................................................15 4.3.1POWERSUPPLYFROMPOWERADAPTER.............................................................................................................................15 4.3.2POWERSUPPLYFROMBATTERY........................................................................................................................................16 4.3.3BATTERYCHARGING.......................................................................................................................................................16 CHAPTERFIVE DEVICE INTERFACE...........................................................................................................................17 5.1STARTUPINTERFACE............................................................................................................................................17 5.2MAININTERFACE..................................................................................................................................................17 5.2.1EXPERTMODE..............................................................................................................................................................17 5.2.2EASYMODE..................................................................................................................................................................18 5.3PATIENTINFORMATIONINPUTINTERFACE............................................................................................................19 5.4BLADDERSCANINTERFACE...................................................................................................................................20 5.4.1EXPERTMODESCAN......................................................................................................................................................20 5.4.2EASYMODESCAN..........................................................................................................................................................20 5.5PATIENTINFORMATIONREVIEW...........................................................................................................................21 5.5.1EXPERTSCANIMAGEREVIEWINTERFACE............................................................................................................................21 5.5.2EASYSCANIMAGEREVIEWINTERFACE...............................................................................................................................22 AvantsonicTechnologyCo.,Ltd iii PadScanDS3 5.6PATIENTINFORMATIONREVIEWINTERFACE.........................................................................................................22 5.7SYSTEMSETUPINTERFACE....................................................................................................................................23 5.8TIMEANDDATESETUP.........................................................................................................................................24 5.9POWERMANAGEMENT........................................................................................................................................24 5.10SERVICE..............................................................................................................................................................25 5.10.1MODESELECTION........................................................................................................................................................25 5.10.1.1Calibration.......................................................................................................................................................26 5.10.2CALIBRATIONVALUERESET............................................................................................................................................26 5.10.3SYSTEMRESET.............................................................................................................................................................27 5.11FIRMWAREUPDATE............................................................................................................................................27 5.12SYSTEMINFORMATION......................................................................................................................................28 5.13LANGUAGESELECTION.......................................................................................................................................28 CHAPTERSIX OPERATIONPROCEDURE....................................................................................................................29 6.1BLADDERSCANNING............................................................................................................................................29 6.1.1GENDERSELECTION........................................................................................................................................................29 6.1.2BLADDERPRESCAN.......................................................................................................................................................29 6.1.3BLADDERSCAN.............................................................................................................................................................29 6.2IMAGEREVIEW....................................................................................................................................................29 6.3PATIENTINFORMATIONINPUT.............................................................................................................................30 6.4PRINT...................................................................................................................................................................31 6.5PATIENTDATESAVE..............................................................................................................................................31 6.6PATIENTINFORMATIONREVIEW...........................................................................................................................31 6.6.1PATIENTDATALOAD.......................................................................................................................................................31 6.6.2PATIENTDATAEXPORT....................................................................................................................................................32 6.6.3PATIENTDATADELETION.................................................................................................................................................32 AvantsonicTechnologyCo.,Ltd iv PadScanDS3 6.7SYSTEMSETUP.....................................................................................................................................................32 6.7.1TIMEANDDATESETUP...................................................................................................................................................32 6.7.2POWERMANAGEMENT...................................................................................................................................................33 6.7.3SERVICE.......................................................................................................................................................................33 6.7.3.1ModeSelection..................................................................................................................................................34 6.7.3.1.1DeviceCalibration..........................................................................................................................................................34 6.7.3.2CalibrationValueResetting...............................................................................................................................35 6.7.3.3SystemResetting................................................................................................................................................35 6.7.4FIRMWAREUPGRADE.....................................................................................................................................................36 6.7.5SYSTEMINFORMATION....................................................................................................................................................36 6.7.6LANGUAGE...................................................................................................................................................................36 6.8COMMUNICATIONMODULE.................................................................................................................................36 6.8.1DS3COMMUNICATIONWITHPC......................................................................................................................................37 6.8.2DS3COMMUNICATEWITHHL7........................................................................................................................................37 6.9PCINTERFACE.......................................................................................................................................................38 6.9.1MAININTERFACE...........................................................................................................................................................38 6.9.2DATASYNCHRONIZATION................................................................................................................................................39 6.9.3OPTION.......................................................................................................................................................................40 6.9.4PRINT..........................................................................................................................................................................40 6.9.5SAVETOPDF................................................................................................................................................................42 6.10SCANANDBLADDERLOCATION..........................................................................................................................44 CHAPTERSEVEN CLEAN ANDMAINTENANCE...........................................................................................................45 7.1SYSTEMCLEANINGANDMAINTENANCE...............................................................................................................45 7.1.1 SYSTEMCLEANING.....................................................................................................................................................45 7.1.2 SYSTEMMAINTENANCE...............................................................................................................................................45 7.2PROBECLEANINGANDMAINTENANCE.................................................................................................................45 7.2.1 CLEANINGANDDISINFECTTHEPROBE............................................................................................................................45 AvantsonicTechnologyCo.,Ltd v PadScanDS3 7.2.2PROBEMAINTENANCE....................................................................................................................................................46 7.3 BATTERYUSEANDMAINTENANCE.................................................................................................................46 7.4DISPOSALOFELECTRONICWASTE.........................................................................................................................46 CHAPTEREIGHT TRANSPORTATIONANDSTORAGE.................................................................................................47 8.1ATTENTIONWHENTRANSPORTINGTHESYSTEM..................................................................................................47 8.2TRANSPORTATIONANDSTORAGECONDITIONS....................................................................................................47 8.3SYSTEMTRANSPORTATION...................................................................................................................................47 8.4SYSTEMSTORAGE.................................................................................................................................................47 CHAPTERNINE INSPECTING ANDTROUBLESHOOTING.............................................................................................48 9.1INSPECTING.........................................................................................................................................................48 9.2TROUBLESHOOTING.............................................................................................................................................48 9.4IFPROBLEMSCONTINUE,PLEASECONTACTAVANTSONICTECHNOLOGYCO.,LTD..................................................50 9.5REPAIR.................................................................................................................................................................50 APPENDIXA LABELINGGRAPHIC.............................................................................................................................51 DS3MAINUNITLABELING......................................................................................................................................................51 DS3POWERADAPTERLABELING...............................................................................................................................................52 DS3PACKAGINGBOXLABELING................................................................................................................................................52 AvantsonicTechnologyCo.,Ltd vi PadScanDS3 ChapterOne Introduction Statement:
ThepowerofinterpretationofthisdocumentisthepropertyofAvantsonicTechnologyCo.,Ltd. Withoutpermissionfromourcompany,thisdocumentmustnotbephotocopied,reproducedor translatedintootherlanguages. Wepreservetherightofrevisingthecontentanditemsonthisdocumentwithoutanyfurther notice. Someoperationsonthisdocumentareexplainedbypicturesandthesepicturesareusedonlyfor indicatingwithoutanyotherpurpose. isthetrademarkofAvantsonicTechnologyCo.,Ltd. Anyabuseofthesetrademarkswithoutpermissionwillbesuedtoassumelegalresponsibility accordingtolaws. 1.1BriefIntroduction ThePadScanDS3byAvantsonicTechnologyCo.,Ltd.providesnoninvasivevolumemeasurementof thebladderbyutilizingrealtimeultrasoundimagingandmeasuring.Theequipmentconsistsof mainunit,3Dprobe,batteryandadapter. Itfeatures:
TwoOperationModes:ExpertModeandEasyMode.Duringtheultrasoundmode,therealtime 2dimensionalultrasoundimagewillbedisplayedonthescreen.Doctorscandecideifthe locationandmeasurementresultisrightornotaccordingtothecrosssectionimageofthe bladder.Duringtheeasymode,2dimensionalultrasoundimagewillnotbedisplayedonthe screen.Theequipmentinstructstheoperatortomovetheprobetofindtherightlocation.(No sonographerisrequiredduringtheeasymode.) Noninvasive,comfortable,correct,reliable,fastandsimpleoperation.Whentheoperator releasesthescanningbutton,multiple2Dplaneultrasoundimagesareacquiredinafew seconds.Theequipmentadoptssophisticatedimageprocessingtechniquestorestorestereo AvantsonicTechnologyCo.,Ltd 1 PadScanDS3 image,adoptssophisticatedalgorithmtomeasurebladdervolumeanddisplaysthe measurementresultonthescreen. Printoutswithultrasoundimagesandvariousparameters CombinedpowersupplywithACadapterandabuiltinbattery. Touchscreenkeyboardoperation Jetmoldingenclosurewithflatstructureandadopting7inchLCDscreen(800x480pixels) 1.2IntendedUse Theequipmentisusedforbladdervolumemeasurementinmedicalunits.Itprovidesthebasisfor theimplementationofclinicalcatheterization,andmakesevaluationofresidualvolumeafter patientsvoidingandassiststhediagnosisofthebladderandrenalfunctiondiseases.This equipmentalsohelpsthedisabledandpeoplewholostthefunctionofautomaticmicturitionto knowthetimeofurination. 1.3Standards IEC606011:2005MedicalelectricalequipmentPart1:Generalrequirementsforsafety IEC6060122:2007MedicalelectricalequipmentPart12:Particularrequirementsforthe Thisequipmentisdesignedandmanufacturedinstrictaccordancewith:
safetyofhighfrequencysurgicalequipment MonitorEquipmentSafetySpecificRequirement IEC60601237 2001MedicalelectricalequipmentPart237:UltrasoundDiagnosisand ISO1099352009Part5:EvaluationofBiologicalPropertiesofMedicalEquipment NEMAUD2 2004:MeasurementStandardofAcousticOutputUltrasoundDiagnosisEquipment RevisedVersion3 ISO149712007 RiskManagement ISO10993102010StimulationandSkinSensitizationExperiment AvantsonicTechnologyCo.,Ltd 2 PadScanDS3 Symbols TypeBdevice Attention!Consultaccompanyingdocuments SwitchOn(generalpower) SwitchOff(generalpower) Signaloutput 0482 CEmarkandcodeofcertificationbody Handlewithcare Temperaturelimit Upwards Limitedlayersofstorage Keepdry Keepawayfromsunlight 1.4ServiceLife Theservicelifeoftheproductissixyears.Constantuseoftheequipmentafterservicelifewill increasetheriskoffailureandunpredictablerisk. AvantsonicTechnologyCo.,Ltd 3 PadScanDS3 Warning:Userswillassumeresponsibilityoftherisksassociatedwiththeuseofthe equipmentafterrecommendedservicelife. Warning:Thedisposaloftheproductsshouldcomplywiththelocalregulations. Dontscraptheproductwithhouseholdrefuse. 1.5OperationalEnvironment Temperature:+5 to+40 Relativehumidity:30%to75%
Pressure:70kPato106kPa 1.6DeclarationofElectromagneticCompatibility PadScanDS3inoperationwillnotinterferewiththewired,wirelessorotherelectricalequipment.It worksproperlyunderspecifiedelectromagneticenvironment. Warning:UsingthePadScanDS3understrongelectromagneticenvironment,closeto generator,Xrayequipment,dentistryandphysiotherapyequipment,broadcastingstation orburiedcable,etc.willintroduceinterferencesignalsintheimage.Thiswillinfluence themeasurement.Pleasestopusingtheequipmentatthemomenttopreventimproper measurement.Usetheequipmentuntiltheinterferenceofpreclusion. Warning:Sharingpowersupplywithotherequipmentsmayproduceabnormalimage. Eliminatetheelectromagneticcouplinginterferenceofanyequipmentbyverification. Warning:Replacingwiththesubstandardsparepartsofequipmentmaycause unpredictableelectromagneticcompatibilityproblems,influencingthelocationof measurementandcausingimpropermeasurement.Onlythecompaniesanddepartments AvantsonicTechnologyCo.,Ltd 4 1.7DeclarationofManufacturer PadScanDS3 Userswillassumealltherisksofmodificationsfortheequipmentwithoutthemanufacturers permission. Warning:Itisprohibitedtoperformanymodificationstotheequipmentwithout themanufacturerspermission. Warning:Modificationstotheequipmentmustbetestedbyappointeddepartment ofthenationtoensurethesafetyofusingtheequipment. 1.8Contraindications Donotusetheequipmentonpatientswithsoresorwoundstopreventcrossinfection. Thisequipmentisnotsuitableforthebladderscanofpregnantwomenandfetus.Donotusethe equipmentonpatientswithascites. Ifyouscanapatientwithacatheterinhis/herbladderorwithscarsinhis/herabdomen, measurementaccuracywillbeaffected. 1.9HeatandMechanicalIndexes Heatindex:PI0.1 Mechanicalindex:MI0.1 AvantsonicTechnologyCo.,Ltd 5 PadScanDS3 ChapterTwo Cautions andWarning Toensuresafety,pleasereadthefollowinginstructionsbeforeusingtheequipment.Theequipment shallonlybeusedbytheprofessionalsaffirmedorauthorizedbyassociatedmedicalinstitution. 2.1EquipmentChecks 1.Makesureallthecablesareproperlyconnected. 2.Makesuretheequipmentisworkingproperly. 3.Keeptheequipmentawayfromsunlightandkeepdry. Warning:Iftheequipmentorcableisdamaged,itisprohibitedtousetheequipment. 2.2SecurityPreparationsbeforeOperation Checkiftheprobeisproperlyconnected.Makesurenowater,chemicalsorothermaterial spatteredontheequipment.Duringusingtheequipment,payattentiontothemainpartsofit.If thereisstrangesoundorsmell,stopusingtheequipmentrightaway;donotusetheequipment untiltheauthorizedengineersolvestheproblem. 2.3OperationInstruction Warning:Donotinsertnorpullouttheprobewhiletheequipmentispoweronin ordernottodamagethemachineandprobe. 1. Duringusingtheequipment,pleaseprotectthesurfaceofprobeanddonotclash.Applythe ultrasoundgelonthesurfaceofprobetoensuretheprobeandbodyiswellcontacted. 2. Payattentiontotheequipmentandpatient.Iftheequipmentbrokedown,turnoffthepower rightawayandthenunplugthepowercord. 3. Patientsareprohibitedtotouchtheequipmentorotherelectricalequipment. 4. Donotcovertheairventoftheequipment. 2.4PostscanChecks 1. Turnoffthepower. 2. Unplugthepowercord AvantsonicTechnologyCo.,Ltd 6 3. Cleantheequipmentandtheprobe 2.5ConditionstoAvoid PadScanDS3 Theequipmentshouldavoidthefollowing:
1. Splash 2. Highhumidity 3. Poordraught 4. Directsunlight 5. Dust 6. Gaswithsaltorsulfur 7. Chemicalmedicinesorgas 8. Strongvibrationandclash 9. Ourcompanytakesnoresponsibilityforanyriskscausedbydisassembling,refittingofthe equipment. 2.6 NoticeofUsingProbe 1. Donotimmersetheprobeintoanyliquid. 2. Donotheattheprobe. 3. Donotpullorbendthecableofprobeinordernottodamageit. 4. Usenationalstandardultrasoundgel.Othersubstance(forexample:oil)willdamagetheprobe andthecableofprobe. 5. Keeptheprobeclean.Useneutraldetergentorwatertocleantheultrasoundgelontheprobe. 2.7HandlingtheEquipment 1.Unplugthepowercord 2.Donotdrop,vibrateorclashthemachineandprobe. 2.8IncaseofEquipmentFailure Ifequipmentisnotworkingproperly,turnoffthepowerandunplugthepowercord.Contact qualifiedmaintenancestaff. AvantsonicTechnologyCo.,Ltd 7 2.9MaintenanceofEquipment 2.10MaintainEquipmentandProbeSafety 2.11Startingup PadScanDS3 Assemblethepoweradapterfirstly.ThenconnectitsACinputplugwithpoweroutletandinsertits DCoutputplugintotheDC13.5Vportontherightsideofthemainunit.Iftheleftindicatorlighton themainunitturnsgreen,itmeanstheDC13.5Voutputvoltageofthepoweradapterisworking properly. Whenyoupressthepowerbuttononthemainunitastherightindicatorlightonthepanelturns green,itentersthePowerOninterface. AvantsonicTechnologyCo.,Ltd 8 PadScanDS3 ChapterThree Device Introduction 3.1Figuration Figure31PadScanDS3FrontDiagram Figure32PadScanDS3DiagramofConnectionPortSide Figure33PadScanDS3BackDiagram AvantsonicTechnologyCo.,Ltd 9 PadScanDS3 3.2TechnicalSpecification Probe:3Dmechanicalsector Standardultrasonicfrequencyofoperaon:2.5MHz Volumemeasurementrange:0ml999ml Volumemeasurementaccuracy:10%
Volumedisplayresoluon:1ml Scanme:5seconds Baerycapacity:2600mA Operaonmethods:touchscreen TissueHarmonicImaging Informaonstorage Informaonprint Mulcoloredimagedisplayselecon Mulcoloredscreenstyleselecon USBport:connecngPCanduserinformaonstorage Bluetoothmodule:connecngPCbywireless Dimensionofmonitor:7inchTFTLCD Consumpon:50W Dimensionofequipment190*135*52mm Weight:about1300g(includingtheprobe) Poweratthestateofcharging:30120VA PowersuppliedbyACwhenbaeryisfullorbythebaery:3040VA Baerychargingme:lessthan2hours Baerylife:morethan4hours AvantsonicTechnologyCo.,Ltd 10 PadScanDS3 3.3BlockDiagram Figure34PadScanDS3PrincipleofElectricityBlockDiagram AvantsonicTechnologyCo.,Ltd 11 PadScanDS3 3.4BasicPrinciple Theequipmentutilizes3Dmechanicalsectorprobetoscanthebladder,andformintomultiple2D ultrasoundimagesonthebasisofdetectedbladderinformation.Aftersophisticatedimage processing,gettingtheareaofmultiplebladdersections,projecting3Dimaging,thenitmeasures thebladdervolumebysophisticatedalgorithm. Operatingprinciple:1.Transmitsthepulsesignaltothe3Dprobe,emittheultrasoundtothehuman bodybythetransducerofprobe.Whentheultrasoundpassesthetissueplaneofhumanbody,it producesreflectedwaveandscatteredwaveandlocatesthetissuesandorgansaccordingtothe returnperiod.Anditdetectsthefeatureoftissueaccordingtotheacousticintensity.Transmitsuch pulsescanonlyacquireonesignalofoneplane,meaningtoproduceasectional2Dimageitneedsto emitultrasoundatleast96or128timestoformonesection.Thentheemittedandreceivedimages willbedisplayedonthescreen.Modulatethegreyscaleofsignalintensityofacousticbeamanda sectionalplaneimagewillbedisplayed.Theelectricalsignalwillbetransmittedtodigitalscan converterforfiltering,detectingandcompressingafteramplification. Thereflectedultrasoundconvertstheacousticenergyintoelectricenergy.Duetothedifferenceof methodanddisplaydirectionofscanimagingandthedifferenceofimagingspeed.Thereisadigital scanconverterintheequipmenttoswitchtheemissionscanintoimagingscaninordertorealize2D sectionalrealtimeimaging.Aseriesofimagingprocessingwillbecarriedoutinthedigitalscan converterthenformasectionalimagewithhighdefinition. The3Dprobeisdrivenbytwoelectricmotors,drivingtherotationandswingofcrystalattopofthe probe.Thelowerstepmotordrives180degreerotationofthecrystalwhereastheupperstepmotor drives120degreeswingofthecrystal.Whenthelowerstepmotorreachestheedgeandbecome fixed,theupperstepmotorwaggles120degree.Andwegetthefirstultrasoundimageatthis moment.Thenthelowerstepmotorrotates15degreeandbecomefixed.Theupperstepmotor swing120degreeandwegetthesecondultrasoundimage.Thenthelowerstepmotorrotate15 degreeandtheupperstepmotorrescan.Thelowerstepmotorrotatesandupperstepmotorswings AvantsonicTechnologyCo.,Ltd 12 PadScanDS3 againandagainuntilthelowerstepmotorrotate180degreeandends.13imagesareacquired. Thentheequipmentprocessesandcalculates12imagesofthe13images,gettingthebladder volume. 3.5EquipmentConfiguration Amainunit ApoweradapterAC100240V24V 50/60Hz, 1.2A120VA 13.5VD.C 5A Mainunit:DC13.5V0.5V AMP2/2.5MHZ3Dmechanicalsectorprobe Abottleofultrasoundgel AUserManual ALiionbattery:model:SNLB325 ACertificate AWarrantyCertificate APackingList Acarryingcase AvantsonicTechnologyCo.,Ltd 13 PadScanDS3 ChapterFour Device Installation 4.1Unpacking Pleasemakesurethereisnoshippingdamageonceyouunpackthedevice.Checkallthepartsand componentsinaccordancewiththePackingListandinstallitbasedontherequirementsand methodsdescribedin"4.2". 4.2Installation CheckthepoweradapterandinsertitsACinputplugintoapoweroutletaftermakingsure adapterspowersupplyiswithinthestipulatedpowerrange. Connecttheprobetothemainunit.Alignthereddotontheprobewiththereddotonthebackofthemain unit(IdentifierofProbe),andinserttheprobeintoprobesocketonrightsideofthemainunitasfigure41. Lockslot:anynotebooksecuritylockisappliedtothislockslotasfigure41. Figure41PadScanDS3ProbeandMainunitConnectionDiagram Batteryinstallationandremoval Batteryinstallation:
Insertthealignmentplateofthebatteryintothealignmentholeofthebatteryslot,andmovethe lockingkeyofthebatteryfollowingthedirectionofarrow.Insertthebatteryintotheslotslowly. Afterthatmovethelockingkeytotheoppositedirectionofarrow.Showasfigure42:
AvantsonicTechnologyCo.,Ltd 14 PadScanDS3 Figure42PadScanDS3BatteryInstallationDiagram Batteryremoval Movethelockingkeyofthebatteryfollowingthedirectionofarrow,pulloutofthebatteryatthe sideseambetweenthebatteryandtheequipment.Showasfigure43. Figure43PadScanDS3RemovalInstallationDiagram 4.3PowerSupply Thedeviceispoweredbypoweradapterandbuiltinbattery,bothofwhichareinterchangeable. 4.3.1PowerSupplyfromPowerAdapter 1.Checkiftheadapterisworkingproperly;verifyiftheEPSisinthespecifiedrange.InserttheAC inputplugoftheadapterintothesocketofthepowersupply.Theoutputvoltageoftheadapteris DC13.5V. 2.ConnecttheDCoutputplugoftheadaptertotheDC13.5Vportontherightsideofthemainunit. Iftheleftindicatorlightonthemainunitturnsgreen,thentheDC13.5Voutputvoltageofadapteris workingproperly.Pressthepowerbuttononthemainunitandtherightindicatorlightturnsgreen, enteringtheworkingstatus. AvantsonicTechnologyCo.,Ltd 15 PadScanDS3 Warning:Itisprohibitedtousetheadapterwhichisnotsuppliedbymanufacturer. 4.3.2PowerSupplyfromBattery 1.Insertthebatteryintothemainunitasdescribedin4.2.Thepowerindicatorlightontheleft turnsgreen. 2.Pressthepowerbuttontoturnonthemachine.Theindicatorlightontherightturnsgreen.The powerisonandthemachineenterstheworkingstatus. 4.3.3BatteryCharging 1.Insertthebatteryintothemainunit 2.ConnecttheDCoutputplugofpoweradapterwiththeDC13.5Vsocketontherightsideofthe mainunit 3.ConnecttheACinputplugofpoweradapterwiththepoweroutlet. 4.Nomatterthedeviceisunderthepoweronorpoweroff,thebatteryisbeingchargediftheleft powerindicatorlightonthemainunitturnsyellow,orfullychargedifthelightturnsgreen. AvantsonicTechnologyCo.,Ltd 16 PadScanDS3 ChapterFive Device Interface 5.1StartupInterface A D E F G H Figure51PadScanDS3StartupInterface A:CompanyLOGO 5.2MainInterface 5.2.1ExpertMode A B C N M L K J I Figure521PadScanDS3ExpertModeMainInterface AvantsonicTechnologyCo.,Ltd 17 PadScanDS3 A:Turntothelast H:SystemSetup B:Ultrasoundimagedisplayarea I:Projectionofprobeaiming C:Batterystatus D:TimeandDate E:Viewpatientinformation F:PrintPatientinformation J:Historicalbladdervolumevalue K:Currentbladdervolumevalue L:Genderselection M:Patientinformation G:SavecurrentPatientinformation N:Turntothenext 5.2.2EasyMode Figure522PadScanDS3EasyModeMainInterface AvantsonicTechnologyCo.,Ltd 18 5.3PatientInformationInputInterface PadScanDS3 A B C D E F G H I J K O N M L Figure53PadScanDS3PatientInformationInputInterface A:Patientname I:EnglishletterandEuropeanlettershift B:Patientnameinputbox J:ConfirmandReturn C:PatientID K:CancelandReturn D:PatientIDinputbox L:Delete E:Patientage M:Space F:Patientageinputbox N:Clear G:Numberkeyboard O:Caplock H:EnglishKeyboard AvantsonicTechnologyCo.,Ltd 19 PadScanDS3 5.4BladderScanInterface 5.4.1ExpertModeScan A B C D Figure541PadScanDS3ExpertScanInterface A:PromptInformation B:Ultrasoundimageoutline C:Ultrasoundimageofbladder D: Serialnumberofcurrentultrasoundimages(01to12) 5.4.2EasyModeScan A AvantsonicTechnologyCo.,Ltd 20 PadScanDS3 Figure542PadScanDS3EasyModeScanInterface A:Crosssectionofbladderdiagram 5.5PatientInformationReview 5.5.1ExpertScanImageReviewInterface A B D C Figure551PadScanDS3ExpertScanImageReviewInterface A:SerialNumberofcurrentultrasoundimages(01to06) B:SerialNumberofOrthogonal C:ProjectionofScannedBladder D:CurrentBladderVolume AvantsonicTechnologyCo.,Ltd 21 PadScanDS3 5.5.2EasyScanImageReviewInterface Figure552PadScanDS3EasyScanImageReviewInterface 5.6PatientInformationReviewInterface A B C D E F G N M L Figure56PadScanDS3PatientInformationReviewInterface A:Serialnumberofpatient B:Patientname AvantsonicTechnologyCo.,Ltd 22 H I J K PadScanDS3 C:PatientID D:Patientage E:Patientgender F:Operationtimeanddate G:Patientbladdervolume H:Load 5.7SystemSetupInterface H G F E D C I:Export J:Delete K:Return L:Nextpage M:Currentpage N:Previouspage A B Figure57PadScanDS3SystemSetupInterface A:DS3Figuration B:Cancelandreturn C:Languagesetup D:Systeminformation E:Firmwareupgrade F:Servicefunction G:Powermanagement H:TimeandDatesetup AvantsonicTechnologyCo.,Ltd 23 PadScanDS3 5.8TimeandDatesetup A B A B Figure58PadScanDS3TimeandDatesetupInterface A:DateSetup B:TimeSetup 5.9PowerManagement Figure59PadScanDS3PowerManagementInterface A:Automaticscreentimeoutsetup B: Automaticpoweroffsetup AvantsonicTechnologyCo.,Ltd 24 5.10Service PadScanDS3 A B D C Figure510PadScanDS3ServiceFunctionInterface A:Password C:OK B:Passwordinputkeyboard D:Clearthecurrentinput 5.10.1ModeSelection A B C Figure5101PadScanDS3ModeSelectionInterface AExpert/EasyModeConversionKey B: USB/PCmodeconversionkey AvantsonicTechnologyCo.,Ltd 25 PadScanDS3 C:Calibrationinterfaceaccesskey 5.10.1.1Calibration A B D C Figure51011PadScanDS3CalibrationInterface A:Currentcalibrationvalue B: Lastcalibrationdate/time C:Calibratekey D:Currentphantomvolumevalue 5.10.2CalibrationValueReset A AvantsonicTechnologyCo.,Ltd 26 PadScanDS3 Figure5102PadScanDS3CalibrationValueReset A:Calibrationresetkey 5.10.3SystemReset A A Figure5103PadScanDS3SystemResetInterface A:SystemResetKey 5.11FirmwareUpdate A:Updatekey Figure511PadScanDS3FirmwareUpdate AvantsonicTechnologyCo.,Ltd 27 PadScanDS3 5.12SystemInformation A B B Figure512PadScanDS3SystemInformationInterface A:SystemInformation B:Systeminformationprint 5.13LanguageSelection A Figure513PadScanDS3LanguageSelectionInterface A:Currentlanguageselectionmarks B:OK AvantsonicTechnologyCo.,Ltd 28 PadScan DS3 ChapterSix Operation Procedure 6.1BladderScanning 6.1.1GenderSelection PoweronDS3tocheckifthesystementersintotheinitializationprocess.Ifyes,itmeansthe encryptionfunctionworksproperly.Theprocessofthesysteminitializationincludescompany LOGOappears,thestartupimageappears,selfexamination,systemstatusidentification, configuration,startupinterface(Figure51).Ittakesabout4secondsbeforeautomaticallyenter themaininterface(Figure521).Click toswitchgendersamongMale
,Female
,Female withhysterectomy
,Child andDefaultoptionisMale. 6.1.2BladderPrescan Placetheultrasoundgelonprobeandthepatient,andputtheprobeontothepatientsbladder. Pressthebuttonontheprobe,andpatientsbladderultrasoundimagesorbladdersectionwithits serialnumberwilldisplayonthescreenintherealtimewaywhenitremindsthatLocatethe bladderwhichmeansitenterstheprescanstate. 6.1.3BladderScan Afterlocatethebladder,pressthebuttonontheprobeagaintostart3Dprobeonscanningwhen patientsbladderultrasoundimages(Figure541)orbladdersection(Figure542)withitsserial number(from01to12) means01Theredlineon rotates15degreesclockwisethe serialnumberplus1).ItremindsthatScanning...Donotmoveprobewhichmeansthebladder scanningisinprogress.Whenthescanning,imageanalysisandmeasurementfinishit automaticallyentertheImageReviewinterface. 6.2ImageReview Whenthescanning,imageanalysisandmeasurementfinish,itautomaticallyentertheImage Reviewinterface.Theimagesviewinginterfaceisdividedintoexpertscanimagesviewinginterface Avantsonic Technology Co.,Ltd 29 PadScan DS3
(Figure551)andeasyscanimagesviewinginterface(Figure552). WhenentertheExpertscanimagesviewinginterface,2orthogonalbladderBultrasoundimages anditsserialnumber,bladderscanprojectionandcurrentbladderurinevolumedisplay.Operator canreview6setsoforthogonalbladderBultrasoundimagesorbladdersectiondiagramby clicking or
.Amongthem,thefirst6(from0106)orthogonalbladderBultrasound imagesorbladdersectiondiagramsdisplayontheleftsideof whilethesecond6(from 0712)orthogonalbladderBultrasoundimagesorbladdersectiondiagramsdisplayontheright sideof
;Thefirst6andsecond6imagesareorthogonal,forexample asthefirstimage and astheseventhoneareorthogonalimages. Whenentertheeasyscanimagesviewinginterfacethebladderscanprojectionandcurrent bladderurinevolumedisplay. Note:Ifthebladderisnotfoundduringthebladderscanningphase,whenjumpingintotheimage viewinginterface,thescreenwillremind:Bladdernotfound.Pleaserescan. 6.3PatientInformationInput Inthemaininterface(Figure521,orfigure522)clickthePatientInformationBox toenterthePatientInformationInputinterface(Figure53)whereinputthepatientName,ID,Age respectively.30digits(Number+English)canbeinputatmostinNameBox,10digits(Number+
English)inIDBoxand3digits(Number)inAgeBox.Click toswitchEnglishintouppercase lettersandclickitagainintolowercaseones.Click todeletetheinputinformation.Click todeleteacharacterbeforethecursor.Click toswitchtheEnglishintoEuropean inputmethod.ClickitrepeatedlytomaketheconversionamongEnglishandEuropeaninput methods.Click tocompletetheinputinformationandreturntothepreviousinterface. Click todirectlyreturntothepreviousinterface. Avantsonic Technology Co.,Ltd 30 6.4Print PadScan DS3 Click intheImageReviewinterface(Figure551or552)tostartontheprinterwhere PatientName,ID,Age,Gender,ScanningTime,BladderUrineVolume,andtwocurrentsetsof orthogonalBultrasonicimagescanbeprintedout.AmongthemName,IDandAgecouldbe inputbeforeorafterthebladderscanning. 6.5PatientDateSave Click intheImageReviewinterface(Figure551or552)tosavecurrentpatient informationincluding:PatientName,ID,Age,Gender,Scanningtime,BladderUrineVolumeand 12BladderBultrasoundImages.Amongthem,Name,IDandAgecouldbeinputbeforeorafter bladderscanning. Note:ThecurrentpatientinformationwillbesavedintotheUdiskifitisinsertedorintoDS3 directlyiftheUdiskisnotinserted.IntheeventthatpatientinformationissavedinUdisk,click tosavetheinformationintoDS3afterUdiskisremoved.AlldatastoredinUdiskcould beviewedundertheSAVEfile. 6.6PatientInformationReview Click intheImageReviewinterface(Figure551or552)toenterthePatient InformationReviewinterface(Figure56)whereallthesavedpatientdataislisted.Clickonedata when ontheleftsidemeansitsbeenselected.Click or toreviewpatient informationlistedinthepreviousornextpage.ThemaximumstorageofDS3is1000cases. 6.6.1PatientDataLoad Click afterselectingonepatientcasetoloadthe currentpatientdata,bladderscanprojectionandultrasound bladderimages(ExpertMode)intothemaininterface. Note:ifselecttwoormorepatientcasesandclick
,a Avantsonic Technology Co.,Ltd 31 PadScan DS3 dialogofPleaseselectonepatient!willappearshownastherightfigure. 6.6.2PatientDataExport InserttheUdiskandclick whenthedialogboxwillappear shownastherightfigure.Select1.Exportselectedpatient.andclick
,toExporttheselectedpatientdatatotheUdisk;Select 2.Exportallpatients.andclick toExportallthepatientdata thatsavedinDS3totheUdisk.TheExporteddatacanbereviewedina foldernamedafterthedate.IfthereisnoUdiskinserted,thesystemwillnotrespond. 6.6.3PatientDataDeletion Click andthefirstdialogboxpopsup. SelectClearselectedpatient,andclick
,theseconddialogboxpopsup,and reminds:Areyousure?Click todelete thecurrentselectedpatientdata;ChoseClear allpatients.Click
,theseconddiaglogboxpopsup,andreminds:Areyousure?Click todeleteallthepatientdatasavedinDS3.Deletionisirretrievablesopleasemakesureall thepatientdatainDS3aresavedbeforedeleted. 6.7SystemSetup Click Inthemaininterface(Figure521or522)andentertheSystemSetupinterface
(Figure57)whereTimeandDate,Powermanagement,Servicefunction,Firmwareupdate, Systeminformation,Languageselection,DisplaymodeandGeneralmodesettingareavailable. 6.7.1TimeandDateSetup ClickDate/TimeontheleftsideoftheSystemSetupinterfacetoentertheDate/TimeSetup interface(Figure58)wheretwooptionsare availableSetdate,Settimetosetuptimeand date.Specificstepsareasfollows:clickSet Avantsonic Technology Co.,Ltd 32 PadScan DS3 dateandthedialogboxshownastherightfigureappearswhereclick
, toadjustthe Year,MonthandDayrespectively;Click tosaveitandthenreturntothepreviousinterface orclick tocanceltheoperationandreturntothepreviousinterface. ClickSettimeandthedialogboxshownasaboveappearswhereclick
, toadjustHour, MinuteandSecond;Click tosaveitandthenreturntothepreviousinterfaceorclick tocanceltheoperationandreturntothepreviousinterface. 6.7.2PowerManagement ClickPowerontheleftsideofthe SystemSetupinterfacetoenterthe PowerManagementinterface(Figure59) wheretwooptionsareavailable:Screen timeoutandAutopoweroff. Specific stepsareasfollowed:clickScreentimeoutandthedialogboxshownastherightfigureappears whereclick toadjustthetimeouttime;Click tosaveitandthenreturntothe previousinterfaceorclick tocancelthecurrentoperationandreturntotheprevious interface. ClickAutopoweroffandthedialogboxshownasbelowappearswhereclick to adjustthepowerofftime;Click tosaveitandthenreturntothepreviousinterfaceor click tocancelthecurrentoperationandreturntothepreviousinterface. 6.7.3Service Click"Service"ontheleftsideoftheSystemSetupinterfacetoentertheServiceinterface(Figure 510wherethreefunctioninterfacesareavailable:ModeSelectioninterface,CalibrationValue Resettinginterface,SystemResettinginterface.Inputthepasswordinthispasswordboxandclick toenterthecorrespondingfunctioninterfaceforsetup. Avantsonic Technology Co.,Ltd 33 PadScan DS3 6.7.3.1ModeSelection Inputthesixdigitpassword000000intheinputboxoftheServiceinterfaceclick to entertheModeSelectioninterface(Figure5101)wherethreeoptionsavailable:Operation modeUSBmodeandAccuracycheck The followingOperationmode,meanstheoperationmodeisExpertMode,andwill displaypatientbladderultrasoundimageswhenbladderscanning.Click toturnitto
,meanstheExpertModeisconvertedtoEasyMode. The followingUSBmodemeanstosetUdiskmodeforUSBconnection.Enterthe PatientDataReviewinterface(Figure56)andinserttheUdisktosaveorloadpatientdatato Udisk.Click toturnitinto whichmeanstheUdiskmodeischangedintoPC modeforUSBconnection,andthenuploadalltherealtimedata(patientinformationand12 bladderultrasoundimages)toPCandsavethem.Repeatedlyclickthiskeyformodeconversion betweenUdiskandPC. Click followingAccuracychecktoentertheDeviceCalibrationinterface. 6.7.3.1.1DeviceCalibration Pleasebekindlynoted,AvantSonicPadScanDS3hasnoneedtobecalibratedforitsentireusing lifeduetothepatentedtechnologieswehaveinultrasoundimagingandmeasurementalgorithm. Regardingthis,weherebyofficiallyspecify:
Withinitsentireusinglife,PadScanBladderScannerDS3undertheintactcondition:
1. TheoperatorsdonotneedtodothecalibrationforclinicalmeasuringaccuracybeforeDS3is usedonpatientsinthefirstplace. 2. Theoperatorsdonotneedtodothecalibrationforclinicalmeasuringaccuracyduringtheir dailywork. 3. TheoperatorsdonotneedtodothecalibrationforclinicalmeasuringaccuracyifDS3is changedwithanotherprobe. Avantsonic Technology Co.,Ltd 34 PadScan DS3 TheCalibration,whetherwritteninourUserManualorsetasoneofpracticalfunctions,isonlyfor thepurposeofmeetingtherequirementsofhospitalbiddingordesignatedprocedurebysome endusercustomers.Ifitsrequired,pleasefollowthenextstepswherepleasebekindlynoted, Dansk616istheonlydesignatedphantommodeltocomply. Click inthemodeselectioninterfacetoenterthedevice calibrationinterface(Figure51011)wherethedeviceis calibrated.Theoperationstepsareasfollows:puttheprobeonto thespecificphantomandclick Dialogueboxastheright oneappears,showing:1,placetheprobeheadintothephantom holderfirmly,2donotremovetheprobeduringthecalibration.Click tomake calibration.Afterthecalibrationiscompleted,itwillpromptwhetherthedevicecalibrationis successfulornot.Ifnot,adjusttheprobeandphantomandcalibratethedeviceagainuntilit successes._intheV=_mlshowsthecurrentphantomvalue.Thedevicehasbeencalibrated beforeexfactoryandisnotrequiredtobecalibratedagain. 6.7.3.2CalibrationValueResetting Enterthepassword410011intheinputboxintheServiceinterfaceandclick toenter theinterfaceofcalibrationvalueresetting(Figure5102).Click toresetthecalibration valueofthisdeviceasitsdefault16. 6.7.3.3SystemResetting Enterthepassword947010intheinputboxintheServiceinterfaceandclick toenter theinterfaceofsystemresetting(Figure5103).Click toresetthesystem,whichwill cometobethedefaultafteryourestartDS3again. Avantsonic Technology Co.,Ltd 35 PadScan DS3 6.7.4FirmwareUpgrade ClicktheUpdateintheleftsideoftheinterfaceofthesystemresettingtoentertheinterfaceof thefirmwareupgrade(Figure511),inserttheUSBdiskwiththefirmwareforupgradingintothe mainunitand toupdatethedevice.DonotshutdownthedeviceorpullouttheUSBdisk inthemiddleofupgrading.TherewillbethedialogueboxofnofirmwarefileiftheUSBdisk isntinsertedorthereisnoupgradingfirmwareinUSBdisk;Ifitisupgradedsuccessfully,the dialogueboxofupgradesucceedwilldisplayonthescreenanditisadvisedtorestartDS3to completetheupgrade;Ifitisfailedtoupgrade,thedialogueboxofupgradefailedwilldisplay onthescreen.Donotshutdownthepowerandupgradeitagainuntilitsucceeds. 6.7.5SystemInformation ClickSystemInfoontheleftsideoftheSystemSetupinterfacetoenterthesysteminformation interface(Figure512)whichshowsthesysteminformationaboutDS3includingdevicemodel, thecurrentsoftwareversion,currentbatterylevel,patientID,SDcardstoragecapacity,SDRAM storagecapacity,EPCScapacityandSRAMcapacity.Click toprintoutthecurrentsystem information. 6.7.6Language ClicktheLanguageintheleftsideofSystemSetupinterfacetoenterthelanguageselection interface(Figure513).Twolanguagesareavailableinthisdevice,including:EnglishandSpanish. Englishisthedefaultoption.Click toconfirmit. 6.8CommunicationModule TherearetwofunctionsbroughtbyDS3communicationmodule:1.DS3communicationwithPC, whichreferstothatpatientinformationwith12ultrasoundbladderimagesisuploadedtoPC softwarethroughwiredorwirelesstransmissiontobesaved,managedandreviewed. 2. DS3 communicationwithHL7system,whichmeansthattherealtimedataincludingpatient informationwith12ultrasoundbladderimagesscannedandobtainedbyDS3isuploadedtoHL7 systemthroughwiredorwirelesstransmissiontobesaved,managedandreviewed. Avantsonic Technology Co.,Ltd 36 PadScan DS3 ThewiredtransmissionbetweenDS3andPCorHL7systemisthroughUSBportconnection,while wirelesstransmissionisthroughBluetoothmodule. 6.8.1DS3CommunicationwithPC TherearetwomethodsofDS3communicationwithPC:wiredandwirelesstransmission,bothof whichrequiretoinstalltheUSBdrivertothePCfirstlybyopeningCH372DRV.EXEsoftwareunder theEXECatalog/ChipDriverInstallation/PC.Thedriverisautomaticallyinstalledin12seconds.
(Notice:itsinstalledonceforall). Wiredtransmissionisoperatedasfollows:clickthe inDS3ModeSelectioninterface
(Figure5101)toturnitinto
,andthenentertheinterfaceofPatientInformationReview
(Figure56).InsertoneendofUSBcableintothePC/USBportandtheotherendintoDS3.Open thePCsoftwareofPatientManager.exewhereclickthePCkeyinthePCModeSelectioninterface tologinandthenclickSyncDatatosynchronizethedatawhileUSBcableshouldbealways connected.Sincethesynchronizationiscompleted,allpatientinformationinDS3willbeuploaded tothePC. Wirelesstransmissionisoperatedasfollows:clickthe intheImageReview(Figure551orFigure 552)toentertheinterfaceofPatientInformationReview(Figure56).OpenthePCsoftwareof PatientManager.exewhereclicktheBluetoothkeyinthePCModeSelectioninterfacetosearchforaccessible Bluetoothdevice(Notice:DS3musthastheBluetoothmodulefunctionfirstly),connectwithDS3successfully, andthenlogintouploadallpatientinformationinDS3tothePCthroughwirelesstransmissionbyclickingSync Data. 6.8.2DS3communicatewithHL7 TherearetwomethodsofDS3communicationwithHL7:wiredandwirelesstransmission.Specific operationsareasfollowed:1.Clickthepatientinformationbox inthemaininterface
(Figure521orFigure522)toenterthepatientinformationinputinterfacewhereyoucaninput Name,IDandAgebyclickingthecorrespondinginputboxesandconfirmallenteredinformation beforebacktothemaininterfacewhereyoucanchoosethegenderbyclickingthegender Avantsonic Technology Co.,Ltd 37 PadScan DS3 selectionkey.2.Placetheprobeontopatientsbladder,pressoncethebuttonoftheprobeto prescan,andpressitagaintostartscanningpatientsbladder;3.IntheeventthatDS3issettoPC connectionwithHL7systemthroughUSBport,therealtimedataincludingpatientinformation with12ultrasoundbladderimagesscannedwillbeuploadedtoHL7systemwhenyouscanthe bladder.IntheeventthatDS3issuccessfullyconnectedwithHL7throughBluetoothmodule
(Notice:DS3defaultoptionisBluetoothconnection),therealtimedataincludingpatient informationwith12ultrasoundbladderimagesscannedwillbeuploadedtoHL7systemthrough wirelesstransmission. 6.9PCInterface 6.9.1MainInterface DS3setupcomesfirstly:clickthe inDS3ModeSetupinterface(Figure5101)toturnit intoPC,whichreferstothewiredtransmissiontoPC.BluetoothconnectionmodeisDS3default setting,thenthewirelesstransmissiontoPCcanbechosen. Enter theinterfaceofDS3Patient InformationReview(Figure56). ThenPCsetupfollows:openthePCsoftware(PatientManager.exe)todisplaythePCModeSetup interfacewherePCandBluetoothareavailable.InPCconnectionmode(thatiswiredtransmission toPC),clickthePCandconnectitwithUSBcable.OrclicktheBluetoothtoselectthewireless transmissionwithPC,searchfortheaccessibleBluetoothdevice(Notice:DS3musthasthe Bluetoothmodulefunctionfirstly)andconnectwithDS3successfully.Sincetheconnectionis completed,itautomaticallyentersthePCmaininterface(Figure61)whichdisplays:4Items,PC information,CompanyLogo,PatientInformationand12ultrasoundbladderimages.4items include:SyncData,Print,SavetoPDFandOption.PatientinformationincludespatientID,name, age,gender;scantimeandbladderurinaryvolume.12ultrasoundimagesareshowninimage displayareabyselectingoneofpatientinformation.Defaultdisplayisthefirst6imagesandthe second6imagesareshownbyclickingthesliderundertheimagedisplayarea. ThemaininterfaceofthePCasFigure61 Avantsonic Technology Co.,Ltd 38 PadScan DS3 A B C D E F G H I J L K Figure61PadScanDS3MainInterfaceofPC A:Syncdata B:Print C:SavetoPDF D:Option E:Patientname F:Patientage G:Patientgender H:Dateandtimewhenscanning I:CompanyLOGO J:Bladderurinevolume K:Bladderimagesdisplayarea L:PatientID 6.9.2DataSynchronization AccordingtoSection6.9.1Interface,therearetwomethodstoenterthemaininterfaceofthePC:
selectthewiretransmissionmethodbyclickingPCkeyandconnectwithUSBcable;selectthe wirelesstransmissionmethodbyclickingBluetoothkey,searchfortheaccessibleBluetooth Avantsonic Technology Co.,Ltd 39 PadScan DS3 device(Notice:theBluetoothconnectionmodeisDS3defaultsetting)andconnectitwithDS3. Whenitconnectssuccessfully,itautomaticallyentersthemaininterfaceofthePC. ClicktheSyncDatainmaininterfaceofthePCanddialogueboxofSyncDataappears,showing:
Synchronizing...Pleasewait!whichindicatestheunsynchronizedpatientinformationinReview interfaceinDS3isbeingsynchronizedtothePC.Whenthedialogueboxdisappears,Synchronize successfully!isshownintheinterface,whichindicatesthesynchronizationiscompleted.Ifthere isnounsynchronizedpatientinformationinReviewinterfaceinDS3,Nonewdata!isshownin theinterface;IftheconnectionofBluetoothandDS3fails,Opendevicefailed!isshowninthe interface. 6.9.3Option ClicktheOptioninthemaininterfaceofPC,thedialogueboxofOptionappears(Figure62)and informationcouldbetappedinandsavedbyclickingSavekeyorcanceledbyclickingCancel key.AllsavedinformationcouldbereviewedinPatientManager/option.ini OptioninterfaceinthePCseenasFigure62 E A B C D Figure62OptionInterfaceinthePCofPadScanDS3 A:Hospitalnameinputbox B: Departmentnameinputbox C:Physiciannameinputbox D:Cancelkey E:Savekey 6.9.4Print ClickthePrintinthemaininterfaceofPC,thePrintinterfaceappears,whichincludes6or12 imagesselectionbox,printkey,hospitalname,departmentname,patientinformationand bladderultrasound images. Click6or12imagesselectionboxandselect6Images,6bladder Avantsonic Technology Co.,Ltd 40 PadScan DS3 ultrasoundimageswilldisplayintheprintinterface(Figure63).ClickPrintkey(6or12images selectionbox,printkeyandXkeywillnotbeprinted);Select12Imagesand12bladderultrasound imageswilldisplayintheprintinterface(Figure64).ClickPrintkey(sameasabove).Thenames ofhospitalanddepartmentareinputtedandsavedinOptioninterfacewhilepatientinformation andbladderultrasoundimagesaredisplayedinthemaininterfaceofPCThepatientinformation couldbereviewedinPatientManager/Printinfo.ini ThePrintinterfaceofPC(6images)FiguredasImage63:
A B C D Figure63PrintInterfaceofthePCofPadScanDS3(6images) A:Selectionboxof6or12imagesdisplayed C:Patientinformation B:Printbutton D:6bladderultrasoundimages Avantsonic Technology Co.,Ltd 41 PadScan DS3 ThePrintinterfaceofPC(12images)FiguredasImage64:
A Figure64PrintInterfaceofPCofPadScanDS3(12images) A:12Bladderultrasoundimages 6.9.5SavetoPDF ClicktheSavetoPDFinthemaininterfaceofthePC,andthedialogueboxofSavetoPDFappears, whichincludesFileSavePath,FileNameandFileSaveType.PDF*.pdfistheonlytypeavailableinFile Avantsonic Technology Co.,Ltd 42 PadScan DS3 SaveType.Itisconvenienttostoreupandreviewthepatientinformationandimageswhenfilesare savedasPDF.TheinformationsavedasPDFisthesamewithwhatprintedout(12images) Avantsonic Technology Co.,Ltd 43 PadScan DS3 6.10ScanandBladderLocation Locatingthebladderpreciselyisthebasisofaccurately measuringthebladdervolume.Bladderisbeneaththe connectionofabdomenandpubicbone,shownasthe rightimage.Beforescan,placeanamplequantityof ultrasoundgelonthepatientsabdomen,approximately 3cmabovethepubicbone,andlocatetheprobeshownastheimage.Makesuretheprobes buttonfaceuptowardsthepatientshead. Inordertocorrectlymeasurethevolumeofthebladder,grasptheprobeasright imageshown. Tomakesureusercouldquicklylocatethebladder,thereappearsa greenlineinthecenterofimagewhenprescanandscaninexpertmode, andusershouldmovetheprobetomakethebladderimagetothecenter
(Greenoutlineindicatestheimageiscentered,whilethegreyoutlineindicatestheimagedeviates fromthecenter)andmakesurethebladdersectionareaisthebiggest.Ineasymode,usershould movethecenterofbladdersectiontothecenterofthecircle.(Greenbladdersectionindicates theimageiscentered,whilethegreysectionindicatestheimagedeviatesfromthecenter)and makesurethebladdersectionareaisthebiggest. Afterscan,itautomaticallyenterstheimagereviewinterfacewheregreenprojectionwilldisplay
(Figure551orFigure552).Thescanresultcountsaslongasthecenterofgreenprojection doesntdeviatetoomuchfromthecenterofcrosshaircircle. Avantsonic Technology Co.,Ltd 44 PadScan DS3 ChapterSeven Clean andMaintenance Components,accessoriesandprobeshouldbecleanedandmaintainedregularlytomakesurethe machineworksonwell.Themilddetergentisrecommendedforthepurposeofcleaning. 7.1SystemCleaningandMaintenance 7.1.1 SystemCleaning
(1) TurnOFFthesystempower.
(2) Unplugthepowersupplyfromthesystem.
(3) Useamilddetergenttocleanthedevicessurfaceincludingkeyboard.
(4) Wipetimeshouldfollowtheinstructionsofdetergentandthewipeintervalsshouldmeetthe clinicalstandard.
(5) Ifyouuseadetergentsolutiontocleantheinstrument,removeallresidualdetergent.Letair dryoruseacleansoftclothtowipedry.
(6) Useamilddetergenttowipeoffthefingerprintsorothersmearsonthescreenincaseof scratchagainstthescreen. 7.1.2 SystemMaintenance
(1) Systemshouldbeoperatedundertheconditionstipulatedin1.5.
(2) Systemshouldnotbeshutdownandopeneduptoofrequently.Aftershutdown,waitfive minutesbeforerestartingthesystem.
(3) Whenthedeviceisnotusedforalongtime,packupthedeviceasexworkstandardand storeitintheenvironmentoutlinedin8.1. 7.2ProbeCleaningandMaintenance Keeptheprobecleanforitsfunctionandlongservicelife. 7.2.1 CleaningandDisinfecttheProbe
(1) Checktheprobeandothercablesforsignsofdamage,suchascrackingand/orleaking.Ifany signofdamageappears,stopusingtheprobeandcontactAvantsonicTechnologyCo.,Ltd.
(2) UseasoftclothdampenedwithisopropylalcoholtowipetheProbe. Avantsonic Technology Co.,Ltd 45 PadScan DS3 7.2.2ProbeMaintenance Preventtheprobesurfacefrombeingscratched
(1) Donotcrashordroptheprobe.
(2) Useonlydomesticallyrecognizedmedicalultrasoundgelontheprobeandpatient.Improper gelwoulddamagetheprobeandstimulatetheskinofpatient.
(3) Alwayscleantheprobeafteritsused 7.3 BatteryUseandMaintenance
(1) Foroptimumperformance,itisrecommendedtochargeandcompletelydischargeanew batterytwotothreetimesbeforefirstuse.
(2) Batterycouldbechargedanddischargedforhundredsoftimes.Whentheservicetimeof batterygetsshorterthanusual,batteryshouldbechangedimmediately.
(3) Alwayskeepbatteryawayfromfire.
(4) Preventthebatteryfrombeingshortcircuit,dampened,disassembled,droppedorcrashed.
(5) Thebatteryshouldbechargedandcompletelydischargedonceeverytwotothreemonthsin caseofmalfunction.Notice:fullpowerbatterywilldischargeslowlyonitsownifitsnotusedfor alongtime,therefore,chargethebatteryafterlongtimeshelvingbeforeuseit
(6) Stopusingthebatteryimmediatelyoncethebatterybecomesdeformedordiscolored,orgets heatorsmellwhenused,pullitoutofthedeviceorbatterycharger,anddisposeitinaccordance withtherequirementofwastebattery. 7.4DisposalofElectronicWaste Wasteproductsandbatteryshouldbedisposedinaccordancewiththelocallawsandregulations inenvironmentprotection.OrcontactourAftersalesServiceDepartment. Avantsonic Technology Co.,Ltd 46 PadScan DS3 ChapterEight Transportation andStorage 8.1AttentionwhenTransportingtheSystem
(1)Unplugthepowercordandputitinthecarryingcase.
(2)Placethemainunitintothecorrespondingslotofthecarryingcasecarefully.Donotdrop, shakeorcrashtheprobeordevice
(3)Thedeviceshouldbetransportedafterthecarrycaseisclosed.
(4)Unplugtheprobefromthemainunitincaseofitscordabradingagainstthegroundand carefullyplaceitintothecorrespondingslotofthecarryingcase.
(5)Keepthebottleofultrasoundgelclosedtightlyincaseofgelleakandcarefullyplaceitintothe correspondingslotofthecarryingcase. 8.2TransportationandStorageConditions Temperature40+55 Relativehumidity1080 Pressure50kpa106kpa 8.3SystemTransportation ThelabelingofthedevicepackagingfulfillstherequirementofGB191PackagingPictorialmarking forhandingSimpleshockproofmaterialsareequippedwiththecarryingcase,whicharesuitable foraviation,railway,highway,orsteamshiptransportation.Keepdry,avoidinversionand collision. 8.4SystemStorage Systemshouldbeunpackedwhenstoragetimeexceedssixmonths.Poweritonforfour hours,andthenrepackit.Donotplaceanyobjectsonthepackage,anddonotplaceitagainst floors,walls,orroof. Keepitinawellventilatedareaawayfromsunlightorcausticgases. Avantsonic Technology Co.,Ltd 47 PadScan DS3 ChapterNine Inspecting andTroubleshooting 9.1Inspecting Checkifthepowersupplyisfunctioningproperly,andifthepowercordofthemainunitis connectedandpluggedintothepoweradapter. Checkiftheprobeandmainunitareconnectedinthecorrectway. 9.2Troubleshooting No. Symptom TroubleshootingMethod Whenpowerbuttonispressed, 1.Checkthepowersupply 1 theindicatordoesnotturnon 2.Checkthepowercordanditsplug andthereisnosignalonthe 3.Checkifthepoweradapteris screenvisible. functioning Snowflakeshapedor 2 meshshapedinterference imagesappearonthescreen. 1. Checkifthepowersupplyisinterfered byotherdevices 2. Checkiftheenvironmentsuchas electromagneticfieldinterfereswiththe device 3. Checkifthepower,probesplugand thesocketsareconnectedwell. Avantsonic Technology Co.,Ltd 48 PadScan DS3 9.3FCCStatement Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustaccept anyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. AnyChangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliance couldvoidtheuser'sauthoritytooperatetheequipment. Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonable protectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththe instructions,maycauseharmfulinterferencetoradiocommunications.However,thereisno guaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescause harmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningthe equipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreof thefollowingmeasures:
Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. FCCRFExposureInformationandStatement ThedeviceshasbeentestedandmeetapplicablelimitsforRadioFrequency(RF)exposure. ThisequipmentcomplieswithFCCradiationexposurerequirement.Thedevisedcanbeusein portableexposureconditionwithoutRFrestriction.Orequivalentmeaning. Avantsonic Technology Co.,Ltd 49 PadScan DS3 9.4Ifproblemscontinue,pleasecontactAvantsonicTechnologyCo., Ltd. 9.5Repair Thedevicemustberepairedbythedepartmentsdesignatedbythemanufacturer. Allmaterialsforrepair,ifneeded,willbeprovidedbythemanufacturer. Avantsonic Technology Co.,Ltd 50 PadScan DS3 AppendixA LabelingGraphic DS3MainUnitLabeling DS3ProbeLabeling Avantsonic Technology Co.,Ltd 51 PadScan DS3 DS3PowerAdapterLabeling Fuyuang R SWITCHING POWER SUPPLY MODEL:FY1355000 INPUT:100-240V~50/60Hz 1.2A 120VA OUTPUT:13.5V 5A ITE POWER SUPPLY E304160 35RS FCC Part 15 Class B ESO110651 N17653 SAA130561EA N136 TUVRheinland R ZERTIFIZIERT geprufte Sicherheit S1 50224721 S1 50203696 PS E JD50195547 JD50248227 VI EFFICIENCY 2000m RoHS HU10419-9002C S&E 2014010907681379
,. CAUTION RISK OF ELECTRIC SHOCK DRY LOCATION USE ONLY DS3PackagingBoxLabeling Avantsonic Technology Co.,Ltd 52
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2017-04-22 | 2402 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2017-04-22
|
||||
1 | Applicant's complete, legal business name |
AvantSonic Technology Co.,Ltd.
|
||||
1 | FCC Registration Number (FRN) |
0026250613
|
||||
1 | Physical Address |
No.394 Jingdongfang Avenue Beibei District
|
||||
1 |
Chongqing, N/A
|
|||||
1 |
China
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
s******@nemko.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AK5H
|
||||
1 | Equipment Product Code |
DS3
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
C******** W****
|
||||
1 | Telephone Number |
+86-7********
|
||||
1 | Fax Number |
+86-7********
|
||||
1 |
w******@sina.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Bladder Scanner | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Output power listed is conducted. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Shenzhen Huatongwei International Insp. Co., Ltd
|
||||
1 | Name |
M****** Y******
|
||||
1 | Telephone Number |
86-75********
|
||||
1 | Fax Number |
86-75********
|
||||
1 |
m******@szhtw.com.cn
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 | 0.0004250 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC