all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 342.63 KiB | ||||
1 | Internal Photos | native | ||||||
1 | Internal Photos | native | ||||||
1 | Internal Photos | native | ||||||
1 | Block Diagram | |||||||
1 | Schematics | |||||||
1 | External Photos | native | ||||||
1 | Internal Photos | native | ||||||
1 | Internal Photos | native | ||||||
1 | Attestation Statements | |||||||
1 | Attestation Statements | |||||||
1 | Operational Description | |||||||
1 | Parts List/Tune Up Info | |||||||
1 | ID Label/Location Info | |||||||
1 | Operational Description | |||||||
1 | Test Report | |||||||
1 | Test Setup Photos | native | ||||||
1 | Test Setup Photos | native | ||||||
1 | Internal Photos | native | ||||||
1 | Internal Photos | native | ||||||
1 | Internal Photos | native | ||||||
1 | Internal Photos | native | ||||||
1 | Internal Photos | native | ||||||
1 | Internal Photos | native |
1 | User Manual | Users Manual | 342.63 KiB |
Tetrapol Band Selective Repeater User Handbook For Coverage Solutions Corporation AFL Works Order N.:Q110695 AFL product part N.:55-124801 Tetrapol Band Selective Repeater User Handbook Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-1 of 32 Table of Contents AMENDMENT LIST RECORD SHEET....................................................................................................4 INTRODUCTION.........................................................................................................................................5 Scope ........................................................................................................................................................................... 5 Purpose ....................................................................................................................................................................... 5 Glossary of Terms...................................................................................................................................................... 6 Key to AFL RF Module Drawing Symbols ............................................................................................................. 7 SAFETY CONSIDERATIONS.........................................................................................................8 1. RF Radiation Hazard ................................................................................................................................... 8 1.1 1.2 Chemical Hazard .......................................................................................................................................... 9 1.3 Emergency Contact Numbers...................................................................................................................... 9 OVERVIEW/SYSTEM DESCRIPTION .......................................................................................10 2. SPECIFICATION............................................................................................................................11 3. 3.1 Parts Lists.................................................................................................................................................... 11 3.2 Technical Specification............................................................................................................................... 12 3.3 Mechanical Specification............................................................................................................................ 13 SYSTEM DRAWINGS ....................................................................................................................14 4. System Diagram.......................................................................................................................................... 14 4.1 4.2 Generic Wall-Mount Case Outline Drawing............................................................................................ 15 SUB-UNIT MODULES....................................................................................................................16 5. Bandpass Filters & Duplexer (02-007306 & 16-041401)......................................................................... 16 5.1 5.1.1 Description ............................................................................................................................................... 16 5.1.2 Technical Specification (02-007306)........................................................................................................ 16 5.1.3 Technical Specification (16-041401)........................................................................................................ 16 Watt 0- -30dB Switched Attenuator (10-000701).................................................................................. 17 5.2 5.2.1 General Application ................................................................................................................................. 17 5.2.2 Switched Attenuators ................................................................................................................................ 17 5.3 Low Noise Amplifiers (11-007302 & 11-007402)...................................................................................... 17 5.3.1 Description ............................................................................................................................................... 17 Technical Specification, 11-007302 ......................................................................................................... 17 5.3.2 5.3.3 Technical Specification, 11-007402 ......................................................................................................... 18 5.4 1Watt Low Power Amplifier (11-007901)................................................................................................. 18 5.4.1 Description ............................................................................................................................................... 18 5.4.2 Technical Specifications ........................................................................................................................... 18 10W Power Amplifier (12-016302)............................................................................................................ 19 5.5 5.5.1 Description ............................................................................................................................................... 19 5.5.2 Technical Specification............................................................................................................................. 19 Dual DC/DC Converter (13-001803)......................................................................................................... 20 5.6 5.6.1 Description ............................................................................................................................................... 20 5.6.2 Technical Specification............................................................................................................................. 20 5.7 Automatic Gain Control (17-001101, det. & 17-001201, atten.)............................................................. 21 5.7.1 Description ............................................................................................................................................... 21 5.7.2 Technical Specification............................................................................................................................. 22 5.8 24V Single Relay Board (80-008902) ........................................................................................................ 22 5.8.1 Description ............................................................................................................................................... 22 5.9 Generic Amplifier Alarm Wiring Sketch ................................................................................................. 23 Tetrapol Band Selective Repeater User Handbook Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-2 of 32 INSTALLATION .............................................................................................................................24 6. Initial Installation Record.......................................................................................................................... 24 6.1 6.2 Antenna Installation & Gain Calculations............................................................................................... 24 Antenna Isolation........................................................................................................................................ 25 6.3 6.4 Wall Mount Installations ........................................................................................................................... 26 7. MAINTENANCE .............................................................................................................................27 7.1 General Procedures .................................................................................................................................... 27 Fault Finding............................................................................................................................................ 27 7.1.1 7.1.2 Downlink................................................................................................................................................... 28 7.1.3 Uplink ....................................................................................................................................................... 28 Fault repair............................................................................................................................................... 28 7.1.4 7.1.5 Checking service....................................................................................................................................... 29 7.1.6 Service Support......................................................................................................................................... 29 7.2 Tools & Test Equipment ............................................................................................................................ 29 7.3 Care of Modules.......................................................................................................................................... 30 7.3.1 General Comments ................................................................................................................................... 30 7.3.2 Module Removal (LNAs, general procedure): ........................................................................................ 30 7.3.3 Module Replacement (general): ............................................................................................................... 30 7.3.4 Power Amplifiers ...................................................................................................................................... 30 7.3.5 Low Power Amplifier Replacement .......................................................................................................... 31 7.3.6 Module Transportation: ........................................................................................................................... 31 INITIAL EQUIPMENT SET-UP CALCULATIONS.................................................32 APPENDIX A Tetrapol Band Selective Repeater User Handbook Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-3 of 32 AMENDMENT LIST RECORD SHEET Issue N. 1 Date 23/01/2004 Incorporated by CMH Page No.s Amended Reason for new issue 1st Issue Document Ref:-55-124801HBKM Tetrapol Band Selective Repeater User Handbook Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-4 of 32 INTRODUCTION Scope This handbook is for use solely with the equipment identified by the AFL Part Number shown on the front cover. It is not to be used with any other equipment unless specifically authorised by Aerial Facilities Limited. Purpose AFL recommends that the installer of this equipment familiarise his/herself with the safety and installation procedures contained within this document before installation commences. The purpose of this handbook is to provide the user/maintainer with sufficient information to service and repair the equipment to the level agreed. Maintenance and adjustments to any deeper level must be performed by AFL, normally at the companys repair facility in Chesham, England. This handbook has been prepared in accordance with BS 4884, and AFLs Quality procedures, which maintain the companys registration to ISO 9001: 1994 and to the R&TTE Directive of the European Parliament. Copies of the relevant certificates and the company Quality Manual can be supplied on application to the Quality Manager. This document fulfils the relevant requirements of Article 6 of the R&TTE Directive. Limitation of Information Notice This manual is written for the use of technically competent operators/service persons. No liability is accepted by AFL for use or misuse of this manual, the information contained therein, or the consequences of any actions resulting from the use of the said information, including, but not limited to, descriptive, procedural, typographical, arithmetical, or listing errors. Furthermore, AFL does not warrant the absolute accuracy of the information contained within this manual, or its completeness, fitness for purpose, or scope. AFL has a policy of continuous product development and enhancement, and as such, reserves the right to amend, alter, update and generally change the contents, appearance and pertinence of this document without notice. All AFL products carry a twelve month warranty from date of shipment. The warranty is expressly on a return to base repair or exchange basis and the warranty cover does not extend to on-site repair or complete unit exchange. Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-5 of 32 Tetrapol Band Selective Repeater User Handbook Glossary of Terms Repeater or Cell Enhancer Channel Selective Repeater BTS C/NR Downlink (D.L.) Uplink (U.L.) EMC GND DC AC ID OIP3 LED M.S. N/A N/C NF RF Rx Tx S/N A Radio Frequency (RF) amplifier which can simultaneously amplify and
(MS) and Base Transceiver Station (BTS) signals. re-broadcast Mobile Station Band Selective Repeater A Cell Enhancer designed for operation on a range of channels within a specified frequency band. A Cell Enhancer, designed for operation on specified channel(s) within a specified frequency band. Channel frequencies may be factory set or on-site programmable. Base Transceiver Station Carrier-to-Noise Ratio RF signals transmitted from the BTS and to the MS RF signals transmitted from the MS to the BTS Electromagnetic Compatibility Ground Direct Current Alternating Current Identification Number Output Third Order Intercept Point = RFout +(C/I)/2 Light Emitting Diode Mobile Station Not Applicable No Connection Noise Figure Radio Frequency Receiver Transmitter Serial Number Tetrapol Band Selective Repeater User Handbook Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-6 of 32 Key to AFL RF Module Drawing Symbols Tetrapol Band Selective Repeater User Handbook Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-7 of 32 1. SAFETY CONSIDERATIONS 1.1 RF Radiation Hazard RF radiation, (especially at UHF frequencies) arising from transmitter outputs connected to AFLs equipment, must be considered a safety hazard. This condition might only occur in the event of cable disconnection, or because a spare output has been left unterminated. Either of these conditions would impair the systems efficiency. No investigation should be carried out until all RF power sources have been removed. This would always be a wise precaution, despite the severe mismatch between the impedance of an N type connector at 50, and that of free space at 377, which would severely mitigate against the efficient radiation of RF power. Radio frequency burns could also be a hazard, if any RF power carrying components were to be carelessly touched!
Antenna positions should be chosen to comply with requirements (both local & statutory) regarding exposure of personnel to RF radiation. When connected to an antenna, the unit is capable of producing RF field strengths, which may exceed guideline safe values especially if used with antennas having appreciable gain. In this regard the use of directional antennas with backscreens and a strict site rule that personnel must remain behind the screen while the RF power is on, is strongly recommended. Where the equipment is used near power lines, or in association with temporary masts not having lightning protection, the use of a safety earth connected to the case-earthing bolt is strongly advised. Tetrapol Band Selective Repeater User Handbook Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-8 of 32 1.2 Chemical Hazard Beryllium Oxide, also known as Beryllium Monoxide, or Thermalox, is sometimes used in devices within equipment produced by Aerial Facilities Ltd. Beryllium oxide dust can be toxic if inhaled, leading to chronic respiratory problems. It is harmless if ingested or by contact. Products that contain beryllium are load terminations (dummy loads) and some power amplifiers. These products can be identified by a yellow and black skull and crossbones danger symbol (shown above). They are marked as hazardous in line with international regulations, but pose no threat under normal circumstances. Only if a component containing beryllium oxide has suffered catastrophic failure, or exploded, will there be any danger of the formation of dust. Any dust that has been created will be contained within the equipment module as long as the module remains sealed. For this reason, any module carrying the yellow and black danger sign should not be opened. If the equipment is suspected of failure, or is at the end of its life-cycle, it must be returned to Aerial Facilities Ltd for disposal. To return such equipment, please contact the Quality Department, who will give you a Returned Materials Authorisation (RMA) number. Please quote this number on the packing documents, and on all correspondence relating to the shipment. PolyTetraFluoroEthylene, (P.T.F.E.) and P.T.F.E. Composite Materials Many modules/components in AFL equipment contain P.T.F.E. as part of the RF insulation barrier. This material should never be heated to the point where smoke or fumes are evolved. Any person feeling drowsy after coming into contact with P.T.F.E. especially dust or fumes should seek medical attention. Emergency Contact Numbers 1.3 The AFL Quality Department can be contacted on:
Telephone Fax e-mail
+44 (0)1494 777000
+44 (0)1494 777002 qa@aerial.co.uk Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-9 of 32 Tetrapol Band Selective Repeater User Handbook 2. OVERVIEW/SYSTEM DESCRIPTION The AFL Band Selective Cell Enhancer is a 2-way on-band repeater. Various models are available to cover frequency bands from 50MHz to 3000MHz with power levels up to 100Watts. Its main sphere of applications is in urban areas where the topology is such that shadows occur in the propagation pattern (for example within large buildings, conference centres and tunnels, etc.) The Band Selective Cell Enhancer is a 2-port device for direct connection to two antennas, usually a highly directional Yagi or similar aligned towards the base (donor) site and an omni-directional or leaky feeder antenna to cover the mobiles. The frequency bands that are passed by the Cell Enhancer are set as per the specific customer requirements. AFL manufacture a wide range of Cell Enhancers, configured for each customer's specific requirements. Two basic physical variants are available, a rack mounted version to fit in a standard 19" rack and an environmentally sealed wall mounted version which requires no further enclosure. This system consists of a bi-directional band selective, cell enhancer operating in the 390MHz band. It is housed in a wall-mounted environmentally protected (IP65) case powered from an externally supplied 24Volt DC source. Alarms are provided for each amplifier as a summary, volt-free relay contact pair for easy integration into an existing alarm system. A supply isolator switch is fitted inside the unit and there are D.C. and Alarm on indicators on the outside of the door. An automatic gain control system is employed in the uplink path in an attempt to negate the overloading effect from mobiles operated close the antenna. Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-10 of 32 Tetrapol Band Selective Repeater User Handbook 3. SPECIFICATION 3.1 Parts Lists PA 380-470MHz 10W CLASS A SDF C/L5P 380MHzVAR. >5MHz TOP SMA 1/4W0-30dB SWITCHED ATTENUATOR LNA. 380-500MHz 20dB (C/W RELAY) GA LNA. 380-500MHz 30dB GA AFL Part N. Part Description 02-007306 10-000701 11-007302 11-007401 11-007901 AMPLIFIER TETRA 1W 37dB GAIN ASS 12-016302 13-001803 DUAL DC/DC CONVERTER 24V-12V 1A TETRA DUPLEXER SMA/N (ant.) CONN 16-041401 CELL ENHANCER LABEL 6 DIGIT 17-000126 17-001101 CELL ENHANCER AGC DETECTOR/AMP ASS C/E AGC UNIT ATTENUATOR ASSY 17-001201 ENCLOSURE 620 x 420 x 250 (2 H/S) ALU 17-001520 17-001522 BASE PLATE 560 x 345mm 17-001520&9020 17-004730 ATTENUATOR MOUNTING 55-019049 80-008902 80-031820 90-200004 DC I/P LEADS, FREE SOCKET 90-400006 ALARM LEADS 91-030002 N ADAPTOR PANEL FEMALE:FEMALE 91-500013 91-500015 91-500016 91-600001 91-600014 96-700034 96-700035 96-920011 96-920012 97-300028 DC BOX 24V ATO TYPE 2 ASSEMBLY 97-400010 97-900003 99-200017 PWR 2POLE PNL PLUG SEALED IP68 PWR CON CAP SEALED with INT. THREAD PWR 6POLE PNL PLUG SEALED IP68
'D'TYPE 9 WAY PLUG S/B TERM
'D' 9 WAY SOCKET S/B (NON FILTERED) LED RED 5mm IP67 INTEGRAL RES. 24V LED GREEN 5mm IP67 INTEGRAL RES 24V PROXIMITY SWITCH PROXIMITY SWITCH MAGNET 02-7302 FILTER MOUNTING BRACKET 24V RELAY PCB ASSEMBLY 20W PA HEATSINK (NEEDS 17-000526) BLACK PLASTIC HANDLE 37311 RUBBER FOOT 1 1:2' DIA. CAUTION HEAVY LABEL 75 x 55mm Qty. 2 2 2 2 2 2 2 2 1 2 2 1 1 1 2 1 2 1 1 2 1 2 1 2 6 1 1 1 1 1 2 4 1 Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-11 of 32 Tetrapol Band Selective Repeater User Handbook 3.2 Technical Specification PARAMETER SPECIFICATION Frequency range: 380-425MHz (Downlink) 390-435MHz (Uplink) Bandwidth: 45MHz Gain: >90dB Gain Adjustment: 0 15dB (in 1dB step) Uplink Power: >10Watts Downlink Power: >10Watts IP3: +52dBm 1dB Compression point: +40dBm Noise Figure: <5dB AGC: Fitted in Uplink path VSWR: better than 1.5:1 RF Connectors: N type, female Power Supply: 24V DC @ 8A
-10C to +55C
-40C to +70C 1 2 4 operational:
storage:
Alarms Fitted:
(volt-free contacts/TTL) PSU Amplifiers Door Intrusion Temperature range:
Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-12 of 32 Tetrapol Band Selective Repeater User Handbook 3.3 Mechanical Specification Case size Temperature Range:
Height: 620mm Width: 420mm Depth: 250mm
(excluding heatsinks, connectors, handles and feet) Fixings: 4 holes on 670(w) x 457(h)mm operational:
storage:
Weight: >50kg
-10C to +55C
-40C to +70C RF Connectors: N type female Environmental Protection:
IP65 (with door closed and all ports terminated Finish:
Case: To RAL 7032 Heatsinks: Matt black (where fitted) Handles: Black Technopolymer Supply Cable:
Unit supplied with suitable supply input leads with connector and appropriate length of cable. Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-13 of 32 Tetrapol Band Selective Repeater User Handbook 4. SYSTEM DRAWINGS System Diagram 4.1 Tetrapol Band Selective Repeater User Handbook Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-14 of 32 4.2 Generic Wall-Mount Case Outline Drawing Tetrapol Band Selective Repeater User Handbook Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-15 of 32 5. SUB-UNIT MODULES Bandpass Filters & Duplexer (02-007306 & 16-041401) Description 5.1 5.1.1 The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of combline design, and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50 load at the input and output ports. No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously. Technical Specification (02-007306) 5.1.2 PARAMETER SPECIFICATION Response type: Chebyshev Frequency range: 350 500MHz (tuned to spec.) Bandwidth: >5.0 MHz (tuned to spec.) Number of sections: 5 Insertion loss: 1.2 dB VSWR: better than 1.2:1 Connectors: SMA Power handling: 100W max operation:
storage:
Weight: 3 kg
-10C to +55C
-40C to +70C Size: 266 x 143 x 39.5mm Temperature range 5.1.3 Technical Specification (16-041401) RX Pass Band: 380-385MHz TX Pass Band: 390-395MHz Bandwidth: 5 MHz Channel Separation: 5 MHz Insertion Loss: < 1.8 dB Rejection (between channels) >70 dB Rejection at crossover: >50 dB (+2.5MHz low band -
2.5MHz high band) Return Loss: > 20 dB (at all ports) Power Handling (CW): 20W Connectors: N type (Antenna ports) SMA (Tx/Rx ports) Weight: <6kg Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-16 of 32 Tetrapol Band Selective Repeater User Handbook 5.2 Watt 0- -30dB Switched Attenuator (10-000701) 5.2.1 General Application Switched Attenuators In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain. 5.2.2 The AFL switched attenuators are available in two different types; 0 30dB in 2 dB steps (as in this case), or 0 15dB in 1 dB steps. The attenuation is simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly marked with the attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are designed to maintain an accurate 50 impedance over their operating frequency at both input and output. 5.3 Low Noise Amplifiers (11-007302 & 11-007402) 5.3.1 Description The low noise amplifiers used are double stage solid-state low-noise amplifiers. Class A circuitry is used in the units to ensure excellent linearity over a very wide dynamic range. The two active devices are very moderately rated to provide a long trouble-free working life. There are no adjustments on these amplifies, and in the unlikely event of failure then the entire amplifier should be replaced. 5.3.2 Technical Specification, 11-007302 PARAMETER SPECIFICATION Frequency range: 380-500MHz Bandwidth: <140MHz Gain: 20-22dB 1dB Compression Point: +23.5dB (typical) 3rd order intercept: +36dB (typical) Input/Output return loss: >20dB Noise figure: <1.3dB Connectors: SMA female Supply: 200-230mA @ 24V DC operational:
storage:
Weight: <300gm
-10C to +55C
-30C to +70C Size: 90 x 55 x 30.2 (case only) Temperature range:
Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-17 of 32 Tetrapol Band Selective Repeater User Handbook 5.3.3 Technical Specification, 11-007402 PARAMETER SPECIFICATION Frequency range: 380-500MHz Bandwidth: <140MHz Gain: 30-32dB 1dB Compression Point: +22dBm (typical) 3rd order intercept: +34-35dBm (typical) Input/Output return loss: >20dB Noise figure: <1.3dB Connectors: SMA female Supply: 300-330mA @ 24V DC Weight: <300gm Size: 90 x 55 x 30.2 (case only) Temperature range:
operation:
storage:
-10C to +55C
-30C to +70C 5.4 1Watt Low Power Amplifier (11-007901) 5.4.1 Description This amplifier is designed as a 1.0 W driver from 380 MHz to 470 MHz for the 10W output amplifier. It is a 2 stage amplifier where each stage is in balanced configuration. It demonstrates very high linearity and good input/output VSWR. There is a Current Fault Alarm Function, which indicates failure of each one of the RF transistors by various alarm output options. The amplifier is housed in an aluminium case (Alocrom 1200 finish) with SMA connectors for the RF input/output and a 9way D-type connector for DC and alarm outputs. 5.4.2 Technical Specifications PARAMETER SPECIFICATION Frequency range: 380-470MHz Small signal gain: 37.5dB Gain flatness: 0.5dB Gain vs. temperature: 1.5dB operational:
storage:
-10C to +55C
-40C to +70C Temperature range:
Input/output return loss: 18dB Maximum output power: 30.4dBm (@ 1dB comp. point) OIP3: 43dBm Supply voltage: 10-15V DC Current consumption: 780mA (typical) Noise Figure: <1.75dB Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-18 of 32 Tetrapol Band Selective Repeater User Handbook 5.5 5.5.1 10W Power Amplifier (12-016302) Description This amplifier is a Class A 10W power amplifier from 380MHz to 470MHz in a 1 stage balanced configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It has a built-in Current Fault Alarm Function. Its housing is an aluminium case (Alocrom 1200 finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function. 5.5.2 Technical Specification PARAMETER SPECIFICATION Frequency range: 380-470MHz Small signal gain: 23dB Gain flatness: 1.7dB I/O Return loss: >18dB 1dB compression point: +40dBm OIP3: +52dBm Supply voltage: 24V DC Supply current: 2.6Amps (Typical) operational:
storage:
Weight: <2kg (no heatsink)
-10C to +55C
-30C to +70C Temperature range Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-19 of 32 Tetrapol Band Selective Repeater User Handbook 5.6 Dual DC/DC Converter (13-001803) 5.6.1 Description This unit is employed where it is necessary to derive two fixed voltage power supply rails from some higher voltage. Typically it is used to derive 5, 8, 12 or 15V from a 24V input. The circuit is based upon a pair of LM257 series variable voltage regulators (LM2576, 12 &
15V & LM2575, 5V), which are each capable of supplying an absolute maximum of 1.5A output current. Note that at full output current, the dissipation of the device must remain within design limits, bearing in mind the voltage which is being dropped across it. The maximum allowable dissipation will also depend on the efficiency of the heatsink on which the device is mounted. 5.6.2 Technical Specification PARAMETER SPECIFICATION Operating Voltage: 21 27V DC Output Voltage: 12V & 12V (typical) Output Current: 1.0A (maximum per o/p) Connections: Screw Terminal Block operational:
storage
-10C to +55C
-40C to +70C PCB Size: 85 x 63mm Temperature Range Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-20 of 32 Tetrapol Band Selective Repeater User Handbook 5.7 Automatic Gain Control (17-001101, det. & 17-001201, atten.) 5.7.1 Description The equipment is fitted with an Automatic Gain Control (AGC) system. This is generally fitted in the Uplink path (not usually needed in the downlink path, as the signal here is at an almost constant level), to avoid overloading the amplifiers (with the associated performance degradation) should a mobile be operated very close to the unit. The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the attenuator is situated in the RF path between the 1st and 2nd stages of amplification. Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level being delivered by the power amplifier, and when a certain threshold is reached it begins to increase the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading of the power amplifier is avoided. The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as system degradation will occur. The detector comprises of a 50 transmission line with a resistive tap which samples a small portion of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode rectifier, the output of which is a DC voltage proportional to the RF input signal. This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at some earlier point in the RF circuit. The unit contains a 12V DC regulator in the detector module, which supplies stabilised voltage to the DC amplifier and via an external cableform to the AGC attenuator. Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-21 of 32 Tetrapol Band Selective Repeater User Handbook For small signals, below AGC onset, the output control line will be close to 12V and the AGC attenuator will have minimum attenuation. As the signal level increases the control line voltage will fall, increasing the attenuator value and keeping the system output level at a constant value. The AGC onset level is adjusted by the choice of sampler resistor R1 and by the setting of potentiometer VR1. The attenuator comprises a 50 P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. The attenuation is controlled by a DC voltage which is derived from the associated AGC detector unit. 5.7.2 Technical Specification PARAMETER Frequency range:
Attenuation range:
Attenuation steps:
VSWR:
RF Connectors:
Attenuator:
Power Handling:
Detector/amp:
operation:
Temperature Range:
storage:
Attenuator pcb:
Size: Detector/amp pcb Attenuator:
Detector/amp:
Weight:
SPECIFICATION up to 1000MHz 3 to 30dB continuously variable better than 1.2:1 SMA female 1W
>30W (or as required)
-10C to +55C
-40C to +70C 50 x 42 x 21mm 54 x 42 x 21mm 90gm 100gm 5.8 5.8.1 24V Single Relay Board (80-008902) Description The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed via a 15 way in-line connector. The relay is provided with polarity protection diodes and diodes for suppressing the transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. Its common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the main alarm system. Note that the board is available for different voltages (12 or 24V) depending on the type of relay fitted at RL1. Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-22 of 32 Tetrapol Band Selective Repeater User Handbook 5.9 Generic Amplifier Alarm Wiring Sketch Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-23 of 32 Tetrapol Band Selective Repeater User Handbook 6. INSTALLATION 6.1 Initial Installation Record When this equipment is initially commissioned, please use the equipment set-up record sheet in Appendix A. This will help both the installation personnel and AFL should these figures be needed for future reference or diagnosis. 6.2 Antenna Installation & Gain Calculations 1 Most Cell Enhancers require two antennas, one a highly directional Yagi or similar directed towards the donor cell base station, and one a leaky feeder, omni-directional antenna or Yagi to cover the area in which the mobiles are to be served. 2 The maximum gain at which the Cell Enhancer can be set is limited by the isolation that can be achieved between these two antennas. Therefore when the antennas have been installed, inject a signal (at a known power level) into one of them and measure the signal level received by the other antenna on a spectrum analyser. The isolation can then be calculated as the difference between these two figures. The gain in each path of the Cell Enhancer should be set at least 10 dB below this figure, using attenuators as described below in paragraph 5. 3 Also measure the received signal from the donor cell at the input to the Cell Enhancer
(base port). The gain of the Cell Enhancer downlink path should be set such the donor site will not overload the Cell Enhancer amplifiers. It is recommended that the input level should be less than -50dBm at the input of the Cell Enhancer (Base Port). (This figure is assuming maximum gain, and may be increased by the value of the attenuator fitted in the downlink path.) 4 Ensure that the mobile facing antenna has at least 70 dB isolation from the nearest mobile.
(This is usually easily achieved when using a leaky feeder.) 5 The Cell Enhancer gain is set by setting the attenuation in each path (uplink and downlink) between the first two amplifier stages (see markings within the Cell Enhancer or layout drawings for the exact attenuator locations). Note that the uplink (mobile to base) and downlink (base to mobile) path gains are set independently. This allows the paths to have different gains if required to set the correct output power levels. It is recommended that the gains are set such that the Downlink channel output levels 6 from the Cell Enhancer are typically +30dBm per channel
(Input level + Gain = Output level). Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-24 of 32 Tetrapol Band Selective Repeater User Handbook 6.3 Antenna Isolation A). First set up the two antennas & measure the isolation between them. Yagi Yagi or leaky feeder Measure Isolation Between antennas Mobiles Base Site B) Install the Cell Enhancer with its gain set 10dB below the isolation figure obtained above. Yagi Yagi or leaky feeder Base Port Mobile Port Base Site (donor) Cell Enhancer Mobile Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-25 of 32 Tetrapol Band Selective Repeater User Handbook 6.4 Wall Mount Installations The procedure for installing and commissioning a wall-mounted Bi-Directional Amplifier unit is generally as follows:
1 Fix the unit in the chosen position. Ensure the mounting site is a straight, smooth, dry, perpendicular surface (brick or concrete recommended). 2 Fix the two antennas and connect them to the BDA. 3 Connect a suitable mains and/or battery power supply to the unit. 4 Calculate the attenuation settings required for the uplink and the downlink paths, and set the attenuators as described elsewhere in this document. (5.1.3) 5 Switch the BDA mains on with the small switch located inside the unit on the lower right hand side of the case. 6 Make test calls via the equipment to ensure correct operation, if possible monitoring the signal levels during these calls to ensure that the uplink and downlink RF levels are as anticipated. Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-26 of 32 Tetrapol Band Selective Repeater User Handbook 7. MAINTENANCE 7.1 General Procedures Fault Finding 7.1.1 In the event that the performance of the system is suspect, a methodical and logical approach to the problem will reveal the cause of the difficulty. The System consists of modules within a wall mounted, environmentally protected enclosure Transmissions from the main base stations are passed though the system to the mobile radio equipment; this could be a handheld radio or a transceiver in a vehicle. This path is referred to as the downlink. The return signal path from the mobile radio equipment to the base station is referred to as the uplink. The first operation is to check the alarms of each of the active units and determine that the power supplies to the equipment are connected and active. This can be achieved remotely (via CEMS, the RS232 Coverage Enhancement Management System, if fitted), or locally with the front LEDs. The green LED on the front door should be illuminated, while the red alarm indicator should be off. If an Alarm is on, then that individual module must be isolated and individually tested against the original test specification. The individual amplifier units within the shelf have a green LED showing through a hole in their piggy-back alarm board, which is illuminated if the unit is working correctly. If an amplifier is suspect, check the DC power supply to the unit. If no other fault is apparent use a spectrum analyser to measure the incoming signal level at the input and then after reconnecting the amplifier input, measure the output level. Consult with the system diagram
(sect. 4.1) to determine the expected gain and compare result. In the event that there are no alarms on and all units appear to be functioning it will be necessary to test the whole unit in a systematic manner to confirm correct operation. Tetrapol Band Selective Repeater User Handbook Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-27 of 32 Downlink 7.1.2 Confirm that there is a signal at the expected frequency and strength from the base station. If this is not present then the fault may lay outside the system. To confirm this, inject a downlink frequency signal from a known source at the master site BTS input and check for output at the remote site feeder output. If a signal is not received at the output it will be necessary to follow the downlink path through the system to find a point at which the signal is lost. The expected downlink output for the given input can be found in the end-to-end test specification. 7.1.3 Uplink Testing the uplink involves a similar procedure to the downlink except that the frequencies used are those transmitted by the mobile equipment. 7.1.4 Fault repair Once a faulty component has been identified, a decision must be made on the appropriate course to carry out a repair. A competent engineer can quickly remedy typical faults such as faulty connections or cables. The exceptions to this are cable assemblies connecting bandpass filter assemblies that are manufactured to critical lengths to maintain a 50-ohm system. Care should be taken when replacing these types of cables or connectors to ensure that items are of the correct specification. The repair of component modules such as amplifiers and bandpass filters will not usually be possible in the field, as they frequently require specialist knowledge and test equipment to ensure optimum operation. It is recommended that items of this type are replaced with a spare unit and the faulty unit returned to AFL for repair. Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-28 of 32 Tetrapol Band Selective Repeater User Handbook 7.1.5 Checking service Following the repair of any part of the system it is recommended that a full end-to-end test is carried out in accordance with the test specification and that the coverage is checked by survey. It is important to bear in mind that the system includes a radiating cable network and base stations that may be faulty or may have been damaged. 7.1.6 Service Support Advice and assistance with maintaining and servicing this system are available by contacting Aerial Facilities Ltd. 7.2 Tools & Test Equipment The minimum tools and test equipment needed to successfully service this AFL product are as follows:-
Spectrum analyser:
Signal Generator:
Attenuator:
Test Antenna:
Digital multi-meter:
Test cable x 2:
Test cable x 2:
Hand tools:
100kHz to 2GHz (Dynamic range = 90dB). 30MHz to 2GHz (-120dBm to 0dBm o/p level). 20dB, 10W, DC-2GHz, (N male N female). Yagi or dipole for operating frequency. Universal Volt-Ohm-Amp meter. N male N male, 2M long RG214. SMA male N male, 1m long RG223. Philips #1&2 tip screwdriver. 3mm flat bladed screwdriver. SMA spanner and torque setter. Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-29 of 32 Tetrapol Band Selective Repeater User Handbook 7.3 Care of Modules General Comments 7.3.1 Many of the active modules contain semiconductor devices utilising MOS technology, which can be damaged by electrostatic discharge. Correct handling of such modules is mandatory to ensure their long-term reliability. To prevent damage to a module, it must be withdrawn/inserted with care. The module may have connectors on its underside, which might not be visible to the service operative. 7.3.2 The following general instructions should be followed to remove a module:
1 Remove power to the unit 2 Remove all visible connectors (RF, DC & alarm) 3 Release module retaining screws. 4 Slowly but firmly, pull the module straight out of its position. Take care not to twist/turn the module during withdrawal. (When the module is loose, care may be needed, as there may be concealed connections underneath). Module Removal (LNAs, general procedure):
Module Replacement (general):
7.3.3 1 Carefully align the module into its location then slowly push the module directly straight into its position, taking care not to twist/turn it during insertion. 2 Reconnect all connectors, RF, alarm, power etc.,(concealed connectors may have to be connected first). 3 Replace retaining screws (if any). 4 Double-check all connections before applying power. 7.3.4 Power Amplifiers 1) Remove power to the unit. (Switch off @ mains/battery, or remove DC in connector) 2) Remove alarm wires from alarm screw terminal block or disconnect multi-way alarm connector. 3) Carefully disconnect the RF input and output coaxial connectors (usually SMA) If alarm board removal is not required, go to step 5. 4) There is (usually) a plate attached to the alarm board which fixes it to the amplifier, remove its retaining screws and the alarm board can be withdrawn from the amplifier in its entirety. On certain types of amplifier the alarm board is not mounted on a dedicated mounting plate; in this case it will have to firstly be removed by unscrewing it from the mounting pillars, in most cases, the pillars will not have not have to be removed before lifting the amplifier. Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-30 of 32 Tetrapol Band Selective Repeater User Handbook 5) If the amplifier to be removed has a heatsink attached, there may be several different ways it can have been assembled. The most commonly used method, is screws through the front of the heatsink to threaded screw holes (or nuts and bolts), into the amplifier within the main case. If the heatsink is mounted on the rear of the main case (e.g., against a wall in the case of wall mounted enclosures), then the fixing method for the heatsink will be from within the case, (otherwise the enclosure would have to be removed from the wall in order to remove the heatsink). When the heatsink has been removed, the amplifier may be unscrewed from the main casing by its four corner fixings and gently withdrawn. Fitting a new power amplifier module will be the exact reverse of the above. Note: Do not forget to apply fresh heatsink compound to the heatsink/main case joint and also between the amplifier and the main case. 7.3.5 Low Power Amplifier Replacement 1 Disconnect the mains power supply and disconnect the 24V dc supply connector for the LPA. 2 Disconnect the RF input and output cables from the LPA. 3 Disconnect the alarm connector. 4 Remove the alarm monitoring wires from (D type connector) pins 9 and 10. 5 Remove the LPA module by removing the four retaining screws, replace with a new LPA 6 Connect the RF cables to the LPA input and output connectors. Reconnect the wires to module and secure it with the screws. the alarm board connector pins 9 and 10. 7 Reconnect the DC supply connector and turn the mains switch on. Note:
Tighten SMA connectors using only a dedicated SMA torque spanner. If SMA connectors are over-tightened, irreparable damage will occur. . Do not use adjustable pliers to loosen/tighten SMA connectors. Also take care not to drop or knock the module as this can damage (or misalign in the case of tuned passive modules) sensitive internal components. Always store the modules in an environmentally friendly location 7.3.6 Module Transportation:
To maintain the operation, performance and reliability of any module it must be stored and transported correctly. Any module not installed in a whole system must be kept in an anti-
static bag or container. These bags or containers are normally identified by being pink or black, and are often marked with an ESD label. Any module sent back to AFL for investigation/repair must be so protected. Please contact AFLs quality department before returning a module. Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-31 of 32 Tetrapol Band Selective Repeater User Handbook APPENDIX A INITIAL EQUIPMENT SET-UP CALCULATIONS Site Name:
Date:
A - Service Antenna B Donor Antenna C Service Feeder D Donor Feeder GENERAL INFORMATION Client Name:
AFL Equip. Model N. ANTENNA SYSTEMS Model Gain Type Loss Azimuth Length INITIAL PARAMETERS E CE Output Power F Antenna Isolation G Input signal level from donor BTS Operating Voltage DOWNLINK CALCULATIONS Comments Parameter Input signal level (G) CE max. o/p power (E) Gain setting Isolation required Service antenna gain (A) Service antenna feeder loss (C) Effective radiated power (ERP) Attenuator setting E - G
(Gain + 10dB) E+A-C CE gain-gain setting Comments Comments dBm dB dBm V Value dBm dBm dB dB dB dB dBm dB If the input signal level in the uplink path is known and steady, use the following calculation table to determine the gain setting. If the CE features Automatic Gain Control the attenuator should be set to zero and if not, then the attenuation setting for both uplink and downlink should be similar. Parameter Input signal level CE max. o/p power (E) Gain setting Required isolation Donor antenna gain (B) Donor antenna feeder loss (D) Effective radiated power (ERP) Attenuator setting UPLINK CALCULATIONS Comments E+B-D
(CE gain-gain setting) Value dBm dBm dB dB dB dB dBm dB Handbook N.-55-124801HBKM Issue No:-1 Date:-22/01/2004 Page:-32 of 32 Tetrapol Band Selective Repeater User Handbook
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2004-04-26 | 380 ~ 385 | TNB - Licensed Non-Broadcast Station Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2004-04-26
|
||||
1 | Applicant's complete, legal business name |
Axell Wireless
|
||||
1 | FCC Registration Number (FRN) |
0007840820
|
||||
1 | Physical Address |
The Cobham Centre
|
||||
1 |
Marlow, Bucks, N/A SL7 1TF
|
|||||
1 |
United Kingdom
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@supanet.com
|
||||
1 | TCB Scope |
B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
NEO
|
||||
1 | Equipment Product Code |
55-1248SERIES
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
B****** B****
|
||||
1 | Title |
Operations Support Director
|
||||
1 | Telephone Number |
+44(0********
|
||||
1 | Fax Number |
+44(0********
|
||||
1 |
b******@cobhamwireless.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Aerial Facilities Limited
|
||||
1 | Name |
P****** B********
|
||||
1 | Physical Address |
Aerial House, Asheridge Road
|
||||
1 |
Buckinghamshire, HP5 2QD
|
|||||
1 |
United Kingdom
|
|||||
1 | Telephone Number |
44 14********
|
||||
1 | Fax Number |
44 14********
|
||||
1 |
p******@aerial.co.uk
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | 55-124801 UHF Signal Booster | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Booster, Power output shown is per channel at the antenna port. The antenna(s) used for this transmitter must be fixed-mounted on indoor/outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC Bureau(s), including antenna co-location requirements of 1.1307(b)(3). | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
TRL EMC Limited
|
||||
1 | Name |
N**** R********
|
||||
1 | Telephone Number |
44-16********
|
||||
1 | Fax Number |
44-16********
|
||||
1 |
n******@trlcompliance.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 90 | 380.00000000 | 385.00000000 | 1.0000000 | Amp | F3E |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC