Safety and regulatory guide Important health information and safety precautions When using this product, the safety precautions below must be taken to avoid possible legal liabilities and damages. Retain and follow all product safety and operating instructions. Observe all warnings in the operating instructions on the product. To reduce the risk of bodily injury, electric shock, fire, and damage to the equipment, observe the following precautions. Electrical safety This product is intended for use when supplied with power from the AA batteries. Other usage may be dangerous and will invalidate any approval given to this product. Safety precautions for AA batteries Handle battery packs carefully This product contains a AA batteries. There is a risk of fire and burns if the battery pack is handled improperly. WARNING: To reduce risk of fire or burns, do not disassemble, crush, puncture, short external contacts or circuits, expose to temperature above 60 C (140 F), or dispose of in fire or water. Recycle or dispose of used batteries according to the local regulations or reference guide supplied with your product. Avoid dropping the device. If the device is dropped, especially on a hard surface, and the user suspects damage, Take extra precautions take it to a service centre for inspection. If the battery leaks:
Do not allow the leaking fluid to come in contact with skin or clothing. If already in contact, flush the affected area immediately with clean water and seek medical advice. Do not allow the leaking fluid to come in contact with eyes. If already in contact, DO NOT rub; rinse with clean water immediately and seek medical advice. Take extra precautions to keep a leaking battery away from fire as there is a danger of ignition or explosion. Safety precautions for direct sunlight Keep this product away from excessive moisture and extreme temperatures. Do not leave the product inside a vehicle or in places where the temperature may exceed 60C (140F), such as on a car dashboard, window sill, or behind glass that is exposed to direct sunlight or strong ultraviolet light for extended periods of time. This may damage the product, overheat the battery, or pose a risk to the vehicle. Safety precautions for RF exposure Use only original manufacturer-approved accessories, or accessories that do not contain any metal. Use of non-original manufacturer-approved accessories may violate your local RF exposure guidelines and should be avoided. Electrical safety Accessories Use only approved accessories. Do not connect with incompatible products or accessories. Faulty and damaged the device Do not attempt to disassemble this device or its accessory. Only qualified personnel must service or repair this device or its accessory. General precautions Protect your device Always treat your product with care and keep them in a clean and dust-free place. Do not expose your product to open flames or lit tobacco products. Do not drop, throw or try to bend your product. Do not use harsh chemicals, cleaning solvents, or aerosols to clean the product. Do not paint your product. Do not attempt to disassemble your product, only authorised personnel must do so. Store your product at temperatures between 0C to 40C. Please check local regulations for disposal of electronic products. Damage requiring service Unplug the product from the electrical outlet and refer servicing to an authorized service technician or provider under the following conditions:
The product has been damaged by exposure to liquid, dropped, subject to impact or damaged. There are noticeable signs of overheating. The product does not operate normally when you follow the operating instructions. Avoid hot areas The product should be placed away from heat sources such as radiators, heat registers, stoves, or other products
(including amplifiers) that produce heat. Avoid using your device after a dramatic change in temperature When you move your product between environments with very different temperature and/or humidity ranges, condensation may form on or within the device. To avoid damaging the device, allow sufficient time for the moisture to evaporate before using the device. NOTICE: When taking the device from low-temperature conditions into a warmer environment or from high-temperature conditions into a cooler environment, allow the device to acclimate to room temperature before turning on power. Avoid pushing objects into product Never push objects of any kind into cabinet slots or other openings in the product. Slots and openings are provided for ventilation. These openings must not be blocked or covered. Small children Do not leave your device and its accessories within the reach of small children or allow them to play with it. They could hurt themselves or others, or could accidentally damage the device. Your device contains small parts with sharp edges that may cause an injury or which could become detached and create a choking hazard. Consult the doctor immediately if the accessories or battery are swallowed. Repetitive motion injuries To minimize the risk of repetitive strain injuries:
Do not grip the device too tightly Press the buttons lightly Regulatory agency identifications For regulatory identification purposes, your product is assigned a model number of 2PQ6. To ensure continued reliable and safe operation of your device, use only the accessories listed below with your 2PQ6:
Battery Pack with model number AA batteries Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio or television technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC RF Radiation Exposure Statement:
This equipment has been tested and found to comply with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines rules. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.
[ IC ]
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement."
RF Radiation Exposure Statement:
This equipment has been tested and found to comply with IC radiation exposure limits set forth for an uncontrolled environment and meets the RSS-102 of the IC radio frequency (RF) Exposure Guidelines rules. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. claration d'exposition aux radiations RF :
Cet quipement a t test et jug conforme aux limites IC d'exposition aux radiations dfinies pour un environnement non contrl et rpond aux rgles des directives d'exposition aux radiofrquences (RF) CNR-102 IC. Cet metteur ne doit pas tre plac ou opr conjointement avec une autre antenne ou un autre metteur. Contain IC: 6100A-NM230NF
[CE]
This device complies with the R&TTE Directive (1999/5/EC) issued by the Commission of the European Community. We declare under our sole responsibility that our product and in combination with our accessories, to which this declaration relates is in conformity with the appropriate standards EN 300 328, EN 301 489-1 -17, EN62209-2, EN62479, EN 60950 following the provisions of, radio equipment and telecommunication terminal equipment directive 1999/ 5 /EC.
[ NCC ]
[]
WEEE notice Please do not discard your device in a landfill. Electronic devices contain substances that may be hazardous to the environment if not properly disposed of. For more information about electronic and electrical waste equipment disposal, recovery, and collection points, please contact your local city center, household waste disposal service, shop from where you purchased the equipment, or manufacturer of the equipment. RoHS compliance This product is in compliance with Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011, on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) and its amendments. EXPLANATION OF THE GRAPHIC SYMBOLS KRYMDA4XXXXX Designation of the serial number of every device, applied at the device. Krell Precision (Yang Zhou)Co.,Ltd NO.28 XingYang Road,Development Area, YangZhou City ,JiangSu Province.
(Number as an example) Please note the accompanying documents or Observe operating instructions Identification of manufacturer of medical product including address Carefully read this operation manual before setup and commissioning, even if you are already familiar with Charger scales. Electro-medical appliance with attachment for type BF
+60C Transport and storage temperature limit indicating the upper and the lower limit
(Transport and storage temperature on packaging)
-20C
(Drawing will be Modify base on ID Design) EMC GUIDANCE AND MANUFACTURES DECLARATION Guidance and manufacturers declaration-electromagnetic emissions The SCALE 2PQ6 is intended for use in the electromagnetic environment specified below. The customer or the user of the SCALE 2PQ6 should assure that it is used in such an environment. Emission test RF emissions CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC 61000-3-2 Voltage fluctuations
/flicker emissions IEC 61000-3-3 Compliance Group 1 Class B Class A Compliance Electromagnetic environment-guidance The SCALE 2PQ6 uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. The SCALE 2PQ6 is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Guidance and manufacturers declaration-electromagnetic immunity The SCALE 2PQ6 is intended for use in the electromagnetic environment specified below. The customer or the user of the SCALE 2PQ6 should assure that it is used in such an environment. Immunity test Electrostatic discharge(ESD) IEC 60601 test level 6 kV contact 8 kV air Compliance L evel 6 kV contact 8 kV air Electromagnetic environment-guidance Floors should be wood, concrete or ceramic tile. IEC 61000-4-2 Electrical fast transient/burst IEC 61000-4-4 Surge IEC 61000-4-5 Voltage Dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 Power frequency(50/60 Hz) magnetic field IEC 61000-4-8 2kV for power supply lines +
1kV for input/output lines 1kV line(s) to line(s) 2kV line(s) to earth
<5% UT(>95%
dip in UT) for 0,5 cycle 40%
UT(60% dip in UT) for 5 cycles 70% UT(30%
dip in UT) for 25 cycles <5%
UT(>95% dip in UT) for 5 s 2kV for power supply lines Not applicable 1kV differential mode Not applicable
<5% UT(>95%
dip in UT) for 0,5 cycle 40%
UT(60% dip in UT) for 5 cycles 70% UT(30%
dip in UT) for 25 cycles <5%
UT(>95% dip in UT) for 5 s 3 A/m 3 A/m If floors are covered with synthetic material, the relative humidity should be at least 30%
Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. If the user of the SCALE 2PQ6 requires continued operation during power mains interruptions, it is recommended that the SCALE 2PQ6 be powered from an uninterruptible power supply or a battery. The SCALE 2PQ6 power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. NOTE UT is the a.c. mains voltage prior to application of the test level. Guidance and manufacturers declaration-electromagnetic immunity The SCALE 2PQ6 is intended for use in the electromagnetic environment specified below. The customer or the user of the SCALE 2PQ6 should assure that is used in such and environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment-guidance Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 3 Vrms 150 KHz to 80 MHz 3 V/m 80MHz to 2,5 GHz 3 Vrms 3 V/m Portable and mobile RF communications equipment should be used no closer to any part of the SCALE 2PQ6 including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance:
d = 1,2 P d = 1,2 P 80MHz to 800 MHz d = 2,3 P 800MHz to 2,5 GHz Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site surveya, should be less than the compliance level in each frequency rangeb. Interference may occur in the vicinity of equipment marked with the following symbol:
NOTE1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. Recommended separation distance between portable and mobile RF communications equipment and the SCALE The SCALE 2PQ6 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the SCALE 2PQ6 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment
(transmitters) and the SCALE 2PQ6 as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter Separation distance according to frequency of transmitter m W 0,01 0,1 1 10 100 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2,5 GHz d =1,2P d =1,2P d =2,3P 0,12 0,38 1,2 3,8 12 0,12 0,38 1,2 3,8 12 0,23 0,73 2,3 7,3 23 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where p is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. Specification Model Capacity Weight Unit LCD Display Weight Measurement Platform Dimension Power Supply Operation Temperature, Humidity and air pressure 2PQ6 180kg / 396lb Approximately 2.3Kg 45.4mm*121mm ( Included 4pcs icons) LED dot matrix 40x12
'14.2" x 1.3"(360mm x 33.5mm) 4AA batteries 5~35 ( 41F ~ 95F) 30% / 85% RH 80~105KPa Storage/transportation Temperature,
-20~60 (-4F ~ 140F) Humidity and air pressure Expected Service Life Dust / Waterproof level Battery Lift 10% / 95 % RH 50~105KPa 20 months IP21 Approximately 6 months
(When 4 people use 2 times per day) Note: Specifications are subject to change without prior notice. Intended use description: Helping consumers to keep a healthy balance between fat, calories and energy and maintain a fit and healthy body. How calculates your body composition:
Algorithm focuses on the Bioelectrical Impedance Method as well as height, weight, age and gender. WARNING Pregnant women and young children do not use this device. Do no use, or allow others to use, this monitor I fitted with a cardiac pacemaker or other implanted medical device. Manufacturers Declaration of Conformity FCC CLASS B Declaration of Comformity This device complies with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Manufactured by:
Krell Precision (Yang Zhou)Co.,Ltd NO.28 XingYang Road,Development Area, YangZhou City ,JiangSu Province. FDA no.: XXXXXXX / XXXXXXXXXX Proprietary Notice 2014-2015 HTC Corporation. All rights reserved. HTC, the HTC logo, and all other HTC product and service names are the trademarks or registered tradmarks in the U.S. ans/or other countries of HTC Corporation and its affiliates. htc.com 91H0XXXX-XXM Rev.A