Model RF-OMS Radio Frequency Oil Management System Instruction Manual BadgerMeter,Inc. IOM-087-01 11-02 RF Oil Management System INSTRUCTION MANUAL November 2002 Version 1.0 Page 1 of 37 1. General Description 1.1 Technical Data CPU:
Programming:
Interfaces:
RF Communications:
Texas Instrument, MSP430, 8-bit, Serial Flash, 48k bytes of In-system Programmable Flash With Adapter 1 x serial, printer 9600/n/8, code line LF/CF 2-way 902-928MHz Frequency Hopping Spread Spectrum Per FCC Part 15.247 Part 15.109
-10C to +60C Operating Temperature:
NOTE: ANY CHANGES MADE BY THE USER NOT APPROVED BY BADGER METER MAY VOID THE USERS AUTHORITY UNDER FCC REGULATIONS TO OPERATE THE EQUIPMENT. Transformer POWER BOARD MOTHER BOARD FT190 PRINTER RF MODULE Page 2 of 37 LCD DISPLAY KEYBOARD 1.2 Keypad Description FCC ID: GIF-RFKEYPAD FCC CERTIFIED, PART 15, SUBPART C This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Keyboard Description Scroll Key: Used to select option on display Home Key: Pressing this key will return display to the PIN Number and Time/Date screens Backspace Key: Used to backspace when entering data Enter Key: Used to enter data and move to next screens Space Key: Used to enter a space character when entering data 1 ABC -
9 YZ Alphanumeric Keys: Used to enter data on display. Hold down key until the desired character is on display. Then release the key. Page 3 of 37 Programming and Use 2.1 Default Screens:
The Personal Identification Number (PIN) number is 4 numeric digits 1 supervisor account Maximum 50 operators account The supervisor account has access to the management process
(initialization, configuration, communication and report) The operator account only has access to the dispense order process 17mar2002 Version 1.0 22:32 There is no active key: Active keys are the keys that will produce a result for a given screen. This screen is displayed for user information It is displayed during 1 seconds every 5 seconds. The 4 other seconds are reserved Enter Pin No. Screen. Enter Pin No.
, Active keys:
Numeric keys, 2.2 Supervisor Enter Supervisor PIN Number 4 Numeric digits: default is 0000 at initial power-up Page 4 of 37 Management Menu: The management menu displays after entering the supervisor PIN Number Select INI CNF MET REP Active keys:
Action:
, Choose which option you need Screens in INI are accessed only when the Dispense Order list is empty. If the supervisor wants to change one of these parameters whereas the list is not empty, a screen message will be displayed. The supervisor must clear all transaction records through the CNF menu prior to entering the INI
(initialization) menu. For screens with multiple choices, the selection is in inverse video. (i.e. The selection is green on black.) The scroll key is used to select an answer (Example Yes No). The selection is in inverse video, it is validated with the ENTER key. To go to the desired menu, move the scroll key to your choice and press the ENTER key 2.2.1 Initialization Menu Screens (INI) System date and time are initially blank System time is in military standard System date is in format DD/MMM/YYYY (in English) To change month Page 5 of 37 Enter Time
, Enter Time:
Active keys:
Numeric keys, Action:
Enter key with no entry Jumps to TANK UNIT screen If the time/date are already entered into the system, press enter with no date to move to the next screens. Enter time by using the numeric keys to set a 24-hour military time of day. Press when finished to move to the next initialization screen. Enter Date:
Enter Date
--/jan/----
Active keys:
, Numeric keys, Action: Date is changed and tank unit screen is displayed. Alphanumeric keys are validated only for some of the display menus. In these menus to enter a letter just hold the related key and the letters scroll. Then release the key when the letter you want is displayed. Enter date by first entering the two digit day of the month. The cursor will automatically jump to the month. Use a four-digit year. to select month, then enter After date is set, press to move to the next initialization screen. Page 6 of 37 PICTORAL DIAGRAM OF RF OMS LOGICAL SET-UP Steps:
1. Identify and Name Fluid Types 2. Identify and Name Fluid Tanks 3. Associate Fluid Type to Tank Number 4. Identify and Name Hose Reel 5. Identify and Name Meter 6. Associate Tank to Hose 7. Associate Meter to Keypad
(NOTE: Hose and Meter are synonymous.) Page 7 of 37 Tank Initialization:
The tank screens are used to set up the tanks in the system. Each tank is assigned a number and a starting quantity level in the desired unit of measure. The following is the process for installing a tank:
Maximum 8 Tanks The tank id ranges from 1 to 8 By default, the unit type is liters Unit type can be quarts, liters, pints or gallons The tank quantity setting is updated after each dispense from the associated tank. The quantity setting is Format 5.3 digits (99999.999) The tank quantity will be printed out to the nearest whole number after each dispense on the ticket. The Supervisor may update the quantity setting at any time by entering these screens to change levels Tank Unit Tank No -
, Numeric keys, Enter key with no entry jumps to Fluids Screens Enter a numeric value from 1 to 8 and press Active keys:
Action:
Tank Unit LITERS Active keys:
Numeric keys,
, to select between LITERS, QUARTS, PINTS, GALLONS Use and REMOVE. to move to the next screen. Press Tank Stock Level No X: ---------
Page 8 of 37 Active keys Numeric keys, Use the numeric keys to enter a stock level from 00000.000 to 99999.999.
, to move to next screen. Press Fluid Initialization:
This screen is used to set initial stock level or when ever supplier delivers AFP. The fluid screens allow the supervisor to set the fluid names used in the system. The parameters are:
Maximum 8 Fluid types The fluid type id ranges from 1 to 8 The fluid type name is a 16 alphanumeric string Initially, the fluid type name is blank Select Fluid No -
, Active keys:
Numeric keys, Action:
Enter key with no entry moves to Tank/Fluid relationship screen Active keys:
Alphanumeric keys, Fluid No. 1
, Page 9 of 37 Tank-Fluid Relationship Screens:
The relationship between tank id and fluid type id will be 1:1 (one tank assigned to one fluid type id). For example, the supervisor may associate tank #1 with fluid #1 or tank #1 with fluid #2. Each tank must be associated with one and only one fluid type. Tank-Fluid Tank No -
, Active keys:
Action:
Numeric keys, Enter key with no entry moves to Create Hose screens Tank-Fluid Fluid No -
Active keys:
, Numeric keys, The user must enter a valid number for a fluid in the system. Pressing enter after a valid fluid number will bring the Tank-Fluid Tank No screen.
, Page 10 of 37 Creating and Deleting RF Meters: (Meter and Hose are synonymous) This set of screens allows the Supervisor to create or delete RF Meters from the system. The RF Meter number can be found on the RF Meter under the battery pack The RF Meter address format is 10 decimal digits (-.---.---.---) The RF Meters can be created and deleted Maximum 48 RF Meters A given keypad can exchange data only with RF Meters whose address is in this list. All RF Meters addresses and ids are unique The relationship between tank and RF Meter will be 1:n (one tank assigned to n RF Meters). Since there will be a relationship between tank and fluid type, the RF Meter will be assigned to one fluid type. Initially the RF Meter address list is empty Create Hose
, Numeric keys, After validate RF Meter address is entered the tank-hose screen is displayed Enter key with no entry moves to Delete Hose screen If RF Meter address already used Hose Address Already Used Screen is displayed Hose Address Already Used There is no active key. This screen is displayed if another RF Meter already uses the last three number of the RF Meter. If this screen displays check RF Meters in system to make some duplicate RF Meters do not exist, then check to see if this RF Meter has already been created in the system. It is displayed for 3 seconds and it comes back to create hose screen. The relationship between tank and RF Meter will be 1:n (one tank assigned to n meters). Since there will be a relationship between tank and fluid type, the RF Meter will be assigned to one fluid type. Assign the RF Meter to the tank in which it is connected. Tank-Hose Tank No -
Page 11 of 37 Active keys:
Action:
Active keys:
No Action
, Active keys:
Numeric keys, Action: Create hose screen is displayed The supervisor has the option to delete a hose/RF Meter through this screen. This is necessary when there is a change to the system; whereby, a RF Meter needs replacement for any reason. The supervisor should delete from the keypad the removed RF Meter prior to creating the new RF Meter. This will put the new RF Meter in the same logical position with the keypad and the dispense order process will remain the same. Active keys:
Numeric keys, Action:
Delete Hose
, If a RF Meter is deleted, the Delete Hose screen is displayed Enter key with no entry Create Operator screen is displayed Page 12 of 37 Creating and Deleting Operators:
Only valid Operator PIN can dispense AFPs Maximum 50 operators may be created The operator id format is 4 numeric digits The operator name format is 16 alphanumeric digits Initially, the operator list is empty If a new operator has been created, the Operator name screen is displayed Enter key with no entry Delete Operator screen is displayed New operator
, Active keys:
Numeric keys, Action:
Active keys:
Operator XXXX
, Alphanumeric keys, Action: The New operator screen is displayed Delete an operator by entering the four-digit id number for the operator to be deleted. Delete operator
Active keys:
Numeric keys,
, Page 13 of 37 Initialization Menu: Flow Chart
The parameter changes will affect all data in memory (example: if we change the quantity unit from liters to gallons, the general quantity will be simply switched from liters to gallons (no conversion from the previous quantity unit to the new quantity unit)
No pending dispense order Page 14 of 37 Configuration Menu:
The Configuration Menu allows the supervisor to set-up all parameters for the Keypad. The Supervisor is the only user with access to these screens. Clearing Transactions from Keypad Memory:
Removes all transactions (Dispense Order) previously recorded in After an erase memory, it will not be possible to print them out further memory Action:
Clear Transacts YES / NO Active keys:
The selection is in reverse video
, Use the scroll key to select between YES/NO. Print WO Confirm Clear YES / NO No Active keys:
Action:
Displayed during the printing Active keys:
The selection is in reverse video If yes, the keypad automatically prints all transactions stored in the system if an external printer is attached to the keypad. If no printer is attached the user will be asked to confirm the clear. If no, keypad will display the System Reset screen.
, Action: The keypad will automatically return to the Clear Transacts screen on YES or NO confirmation Page 15 of 37 System Reset:
Allows the user to reset all the configuration parameters to default values:
Active keys:
Action:
Active keys:
Active keys:
Action:
System Reset YES / NO
, If yes, the keypad asks the user to confirm If no, the keypad displays the mileage type screen Confirm Reset YES / NO
, Action: The keypad returns to the System Reset screen Mileage Type:
Allows the user to select how mileage is stored in the keypad KM/MILES The mileage type by default is KM. The mileage type is set for all RF Meters in the keypad Mileage Type KM / MILES
, Press enter key to move to Mileage Info screen Page 16 of 37 Mileage and Registration Information Option:
Allows the supervisor to select the storage of vehicle mileage and registration information for each dispense order. YES/NO to the option of entering the vehicle mileage information for each dispense order Mileage information by default is NO Mileage Info YES / NO
, Active keys:
Action: Use the scroll key to select YES/NO, press enter key to move to the Registration option screen YES/NO to the option of entering the vehicle registration information for each dispense order Registration information by default is NO Regist. Info YES / NO
, Active keys:
Action: Use the scroll key to select YES/NO, press enter key to move to the keypad timeout screen Page 17 of 37 Keypad Timeout Option:
Timeout parameter corresponding to the time it takes to validate after all dispense order data has been entered. If the enter button is not pressed within the time allocated, the keypad display goes back to the initial menu, and the input data is erased. The keypad timeout is between 0 to 255 seconds (0 no timeout) and the default for this feature is 10 seconds Keypad Timeout 10-
, Active keys:
Numeric keys, Action:
Press Enter key to move to Hose Inactive Timeout Option Hose Inactive Timeout Option:
Essentially, this is the time the user has to top-off the dispense and completing the automatic batch. Timeout parameter corresponding to the time that a RF Meter could stay inactive after an RF batch has been dispensed. If the user has not pressed reset on the RF Meter within the timeout period, the RF Meter will transmit the dispense order quantity to the keypad and lockout the RF Meter. Meter inactive timeout is sent to the RF meter. Its the meter (ER) that is responsible of tracking this timer. The meter inactive timeout is set for all RF Meters. The meter inactive timeout is between 0 to 65534 seconds (0 = no timeout) and the default value is 10 minutes. Hose Inactive 600
, Active keys:
Numeric keys, Action:
Press Enter key to move to Display Timeout Option Page 18 of 37 Display Timeout Option: (Not a parameter to change in configuration) Timeout parameter corresponding to the time for displaying an information on the keypad LCD before it is refreshed with new information The display timeout is set at 2 seconds Display Timeout 2--
, Active keys:
Numeric keys, Action:
Press Enter key to move to Internal Printer Option Internal Printer Option:
(CUSTOM FT190). YES / NO. Parameter indicating the existence of an internal printer The integrated printer value is set by default NO ( The keypad will not detect the existence of a printer) Press Enter key to move to External Printer Option External Printer Option:
YES / NO. Parameter indicating the existence of an external printer
(EPSON LX300). The external printer value is set by default NO Internal printer YES / NO
, External Printer YES / NO
, Active keys:
Action:
Active keys:
Action:
Press Enter key to move to Supervisor Password Option Page 19 of 37 Supervisor Password Option:
The default supervisor password for protecting the modification of the supervisor id is 0000. It is recommended the Supervisor change this password during the initial set-up of the system. Maximum 1 Supervisor login Use numeric keys to enter the new password then press enter. Enter key with no entry No change to password and displays buzzer option. Active keys:
Numeric keys, Action:
Active keys:
Numeric keys, Super new pass
, Super Confirm
, Action: reenter new password to confirm. Buzzer Option:
This screen provides the user with the option to have a beep on every key entry. The default is YES. Buzzer YES / NO
, Active keys:
Menu. Action: Select YES or NO by using the scroll key, then press Enter. The keypad will display the Supervisor Page 20 of 37 Page 21 of 37 2.2.2 MET Menu:
Only the supervisor has access to this process. The supervisor may delete a dispense order keypad que for a single hose or all hoses in the system. If the supervisor selects all RF Meters, all dispense orders in the que will be deleted and all meters may be programmed for a dispense order. The communication test could be done only with the RF Meters entered in the initialization menu Init all Hose YES / NO
, If YES Start (Hoses Init) is displayed If NO User is prompted for a hose number for communications test Start Hoses Init Press enter Active keys:
Action:
Page 22 of 37 RF Communications Menu Flowchart:
Page 23 of 37 2.2.3 Report Menu Screens:
The supervisor has the opportunity to print out a variety of reports, if there is an external printer connected to the keypad. INI: Prints all parameters associated with the system initialization CNF: Prints all parameters selected for the configuration of the keypad MET: Prints the status of all hoses/meters REP: Prints the dispense order history The external printer has to be activated and connected.
When the keypad is printing out a report or a receipt, the keypad keyboard will be locked for all new data entry (i.e. the operator will not be able to enter a new Dispense Order List while the keypad is printing).
If the keypad detects an error on the integrated printer or the external printer (not connected, out of paper or off line), the keypad keyboard will be locked for all new data entry and an error will displayed on the keypad LCD. The user should check the printers for off-line or out of paper conditions.
If an error is detected while printing, the keypad will not purge the memory (especially in the case of the Dispense Order List report)
After printing out the Dispense Order List report, the Dispense Order list memory is erased automatically The dispense order receipt is automatically (after a user prompt message) printed out after the RF reception of the dispense order result Active keys:
Action:
Select Report INI CNF MET WO
, Use the scroll key to select report option Enter key with no entry keypad returns to Supervisor Menu screen Page 24 of 37 Initialization Report:
DD/MMM/YYYY INITIALIZATION REPORT HH:MI TNK PRODUCT LEVEL UNT
1 Fluid 1 name 99999 LITERS 2 Fluid 2 name 99999 LITERS
() () () () 7 Fluid 7 name 99999 LITERS 8 Fluid 8 name 99999 LITERS ID ADDR TNK
123 124456 1 234 561444 2
() () () ID PIN NAME
1 1234 John SMITH 2 1235 Paul GREEN 3 1236 Mike BROWN
() () () ID PRODUCT
1 Fluid 1 name 2 Fluid 2 name
() () 7 Fluid 7 name 8 Fluid 8 name DD/MMM/YYYY HH:MI TNK PRODUCT QTY UNT ADDR ID TNK PIN NAME Date of the printout Time of the printout Tank No Fluid type name Quantity dispensed Unit Meter RF address RF Meter Id (Last 3 address characters) Tank No User pin number User name Page 25 of 37 Configuration Report:
DD/MMM/YYYY CONFIGURATION REPORT HH:MI Mileage Type Registration Info Mileage Info Internal printer External printer Address printer Buzzer Approved PTB Supervisor pass Hose Inactive Keypad Timeout Display Timeout On-Off sequence 999999 KM NO NO Yes Yes Yes NO 1234 600 10 2 Active keys:
Action:
Active keys:
Select Report INI CNF COM WO
, Use scroll key to move to CNF and press Enter key Enter key with no entry Supervisor Menu screen is displayed Start CNF Report
, Action: After Report is completed the Select Report screen is displayed Page 26 of 37 Communications Report:
/MMM/YYYY COMMUNICATION REPORT HH:MI STA ID
1 inactive inactive 2 inactive 3 4 inactive 5 inactive 6 inactive inactive 7 8 inactive Date of the printout Time of the printout Meter RF address RF Meter Id (Last 3 address characters) Status of the RF link:
OK RF link is established KO RF link not established
? RF link doubtful Select Report INI CNF COM WO
, Use scroll to move to COM and press Enter Enter key with no entry Supervisor Menu screen is displayed Start COM report
, Action: After printing Select Report Menu is displayed DD ADDR
0.000.000.101 0.000.000.137 0.000.000.111 0.000.000.126 0.000.000.127 0.000.000.109 0.000.000.100 0.000.000.135 DD/MMM/YYYY HH:MI ADDR ID STA Active keys:
Action:
Active keys:
Page 27 of 37 Action: Scroll to report to print and press the Enter key There are four reports that may be printed associated with Dispense Orders:
Dispense Order Reports Select Report INI CNF COM WO Scroll to WO and press Enter key Enter key with no entry Supervisor Menu screen is displayed Select REP USR PRO HOS TNK
, Active keys:
Action:
Active keys:
USR: Print dispense orders by Operator PRO: Print dispense orders by Fluid Type HOS: Print dispense orders by Hose/Meter TNK: Print dispense orders by Tank User Report (USR):
DD/MMM/YYYY STATISTICAL REPORT BY USER HH:MI USER PRODUCT QTY
JOHN SMITH FLUID TYPE 1 99999 FLUID TYPE 2 99999 FLUID TYPE 3 99999 FLUID TYPE 4 99999 PAUL GREEN FLUID TYPE 5 99999 FLUID TYPE 6 99999 FLUID TYPE 7 99999 FLUID TYPE 8 99999
() Active keys:
Start Report
, Action: After printing the Select Report Screen is displayed Product Report (PRO):
DD/MMM/YYYY STATISTICAL REPORT BY PRODUCT HH:MI Page 28 of 37 PRODUCT USER QTY
FLUID TYPE 1 JOHN SMITH 99999 PAUL GREEN 99999 FLUID TYPE 2 JOHN SMITH 99999 PAUL GREEN 99999 FLUID TYPE 3 JOHN SMITH 99999 PAUL GREEN 99999
() Start Report Active keys:
, Action: After printing the Select Report Screen is displayed Hose/Meter Report (HOS):
/MMM/YYYY STATISTICAL REPORT BY RF METER HH:MI DD ADDR ID USER QTY
123456 456 JOHN SMITH 99999 PAUL GREEN 99999 234561 561 JOHN SMITH 99999 PAUL GREEN 99999
() Active keys:
Start Report
, Action: After printing the Select Report Screen is displayed Page 29 of 37 Tank Report (TNK):
DD/MMM/YYYY STATISTICAL REPORT TANK LEVEL HH:MI TNK PRODUCT LEVEL UNT
1 5W30 OIL 123 LITERS 2 GEAR OIL 1111 LITERS 3 ATF 111 11111 GALLONS 4 HYDRAULIC FLUID 232 QUARTS 5 10W40 OIL 3466 PINTS 6 WASHER FLUID 1 LITERS 7 5W40 OIL 2344 LITERS 8 BEER 43234 PINTS Start Report
, Active keys:
Action: After printing the Select Report Screen is displayed Report Menu Flowchart REPORT MENU Select Report INI CNF COM WO Start INI Report Start CNF Report Start COM Report Select REP USR PRO HOS TNK Start Report Page 30 of 37 2.3 Operator:
The Operator only has access to the dispense order menus. At the main menu, enter one of the four-digit operator pin numbers. The pin number is 4 numeric characters Maximum 50 operators account The supervisor account has access to the management process The operator account has only access to the dispense order process Dispense Order Process:
After a valid Operator pin number is entered, the following screens form the dispense order process:
Job No: Enter the job or work order number: This may be alphanumeric and up to 16 digits. Enter Job No.
, Alphanumeric keys, Enter the 16-digit alphanumeric work order number and press Enter to move to next screen The next two screens are only displayed if the settings for Registration and Mileage are set to YES in the Configuration Menu. Registration Number: Enter the Registration or License Plate number of Active keys:
Action:
Active keys:
the vehicle. Enter Reg. No.
, Alphanumeric keys, Action: Enter the 10-digit Alphanumeric Registration number and press Enter to move to next screen Page 31 of 37 Mileage: Enter the current mileage on the vehicle. Active keys:
Numeric keys, Enter Mileage
, Action: Enter the numeric current mileage of vehicle and press Enter to move to the next screen Hose: Enter a valid Hose/Meter number for the dispense. This number will be from 1-48, and only valid Hose numbers will be accepted. If an undefined hose number is entered, the display will remain on this screen. If there is an on going dispense already in process with the Hose, a new dispense order for that Hose will not be accepted. Active keys:
Numeric keys, Enter Hose
, Action: Enter a Hose number that has been previously created through the initialization menu and press enter Product: The keypad will automatically display the Fluid Type associated with the Hose previously selected. There is no data entry for this screen. Product
(Fluid Type) There is no active key. This screen is displayed for user information It is display during 3 seconds and it goes to quantity Active keys:
No Action Page 32 of 37 Quantity: Enter the quantity to be dispensed through the Hose. Quantity may be from 0.0-99.9 and 100-999. There may be only one digit after the decimal point. Dispensed quantities from 100-999 will be in count down mode. A quantity of 0.0 will put the RF Meter in a free-dispense mode, the RF Meter will not latch and the user may display fluid as long as the trigger is manually held in the open position. The user must press RESET on the RF Meter to exit this dispense and communicate the dispense order to the Keypad. Active keys:
Numeric keys, Enter Quantity
, Action: Select the quantity to be dispensed and press Enter Active keys:
Press enter for Dispense
, Dispense Confirmation: Press Enter to confirm a dispense is desired. Action: Press the Enter Key to confirm the dispense. Press HOME to cancel order and return to the main screen. Page 33 of 37 Dispense Order Transaction Ticket: A ticket receipt is printed for every dispense after the completion of the dispense by the RF Meter. JOH N SMITH TRANSACTION TICKET DD/MMM/YYYY HH:MI PRODUCT FLUID TYPE 1 QUANTITY 2.1 LTS OPERATOR RF METER ID 12 WO 1234567890123456 MILEAGE -
REGISTRATION -
TYPE PRE-SET/MANUAL/OUT OF SEQUENCE LEVEL 999999 LTS ERROR1 1 (COMMUNICATION ERROR) ERROR2 3 (LOW BATTERIES) ERROR3 5 (COUNT ERROR) The Ticket is printed on the integrated printed if it is installed. A printer must be installed to retrieve dispense order records. Product: Fluid dispensed Quantity: Exact quantity of fluid dispensed by the Hose Operator: Operator who dispensed the fluid RF Meter ID: Hose number WO: Work Order number Mileage: Mileage of vehicle, only printed if configured to YES Registration: Registration or License number, only printed if configured to YES Type: The type of dispense:
Pre-set: Normal Dispense Process Manual: Fluid dispensed while RF Meter was in a manual mode of operation. This is a degraded mode of operation. Out of Sequence: Normal Dispense Process, but data not communicated from the Hose to the Keypad immediately after the dispense. Out of Sequence quantity is only communicated through the Supervisor Menu in COM mode. This is a degraded mode of operation. Level: The remaining amount of fluid in the tank used for the dispense Error13: Error Message for the dispense:
Communication Error: Difficulty in communications Low Batteries: Change the batteries on the RF Meter/hose Count Error: RF Meter had a count error, NOT AN APPROVED DISPENSE. (For PTB System ONLY) Page 34 of 37 Dispense Order Flow Chart:
Operator:
The operator is a user that has only access to the dispense order process. After entering a dispense order, the operator activates the preset RF Meter for a fluid dispense. Receipt:
On integrate printer if connected or on external printer if connected. If both are connected, the integrated one will be used. If none are connected, no receipt will be printed. The dispense order process follows an operator PIN Number Enter Job No.
IF Validate Enter Reg. No.
DISPENSE ORDER MENU Enter Hose
Product
(Fluid type) Enter quantity
Press enter for dispense Enter mileage
Registration and mileage are active only if they are select in the management process. Page 35 of 37 Keypad
(1 per system) Meter # (2 Digits) ____ ____
(Up to 48 meters/keypad) Unique Meter Serial # ____ - ____ ____ ____ - ____ ____ ____
(10 Digits) Hose # ____ ____ ____ ____ ____ ____ Tank # (1 Digit) ____
(Up to 8/keypad) 1:Hose Fluid Type (16 Digits) ____ ____ ____ ____ ____ ____ ____ ____ Description 1:Tank
(Up to 8/keypad) ____ ____ ____ ____ ____ ____ ____ ____ Please see our website at www.badgermeter.com for specific contacts. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding bid obligation exists. BadgerMeter,Inc. P.O. Box 245036, Milwaukee, WI 53224-9536 Telephone: (414) 355-0400 / (877) 243-1010 Fax: (414) 355-7499 / (866) 613-9305 www.badgermeter.com Copyright Badger Meter, Inc. 2002. All rights reserved.