zur Prfung GENERAL VIEW LED INDICATORS INSTALLATION GUIDELINES BF-IDU07 BIS U-620-068-1X1-00-SX Ultra High Frequency Passive Radio Frequency, Identification Processor INSTALLATION GUIDE This document provides information designed to assist users in the hardware setup of the BIS U-
620-068-1x1-00-Sx Processor. For configuration details see the BIS U-62_ Processor Manual. instructions and PACKAGE CONTENTS Qty 1 1 1 Description BIS U-620-068-1x1-00-Sx Processor UHF Series Configuration Tag This Installation Guide TECHNICAL DATA ELECTRICAL FEATURES Power Supply DC Input Current Communication Interface Baud Rate RADIO FEATURES Frequency (MHz) ETSI EN 302 208 FCC part 15.247 Number of Channels Frequency Tolerance Air Interface Conducted Output Power Antenna Connector ENVIRONMENTAL FEATURES Operating Temperature Storage Temperature Humidity max. Vibration Resistance EN 60068-2-6 Shock Resistance EN 60068-2-27 Protection Class EN 60529 PHYSICAL FEATURES Dimensions Weight Enclosure USER INTERFACE LED Indicators 19.228.8 V DC 1 A RS232 9600 (default) 115200 EU 865868 US
902928 50 hopping 10 ppm over entire temp 4 fixed range EPC C1G2 500 mW (27 dBm) max Reverse TNC
-20+50 C
(-4+122 F)
-20+70 C
(-4+158 F) 90 % non condensing 14 mm @ 210 Hz;
1.5 mm @ 1355 Hz;
2 g @ 70200 Hz;
2 hours on each axis 30 g; 11 ms;
3 shocks on each axis IP65*
164 x 112 x 48 mm
(6.46 x 4.41 x 1.88 in) 560 g (19.8 oz) Powder Coated Aluminum READY, RF, COM
* When all connectors and antenna are correctly installed. The BIS U-620-068-1x1-00-Sx Processor and its antenna are intended for indoor use only. CONNECTIVITY M12 8 pin Male Connector (Data and Power Supply) Typical Layout BIS U-30x antenna green READY The READY LED is ON after the power up sequence has completed. amber RF The RF LED illuminates when RF power the antenna. transmitted by is being amber COM The COM
(communications) LED flashes ON and OFF when data is being transmitted between the antenna and a tag. When in Continuous Read mode, the COM LED will remain ON and will turn OFF briefly only while data is being read from or written to a tag. BCC0ETJ Host Vdc (red) Power Supply GND (black) mm in
* Digital I/O (-ST29 models only)
1 x 1
8 6 0
0 2 6
U S B I
RF performance and read/write range can be negatively impacted by the proximity of metallic objects and liquids. Avoid mounting the BIS U-3x antenna within 15 cm (6 inches) of any metallic object or wet surface. Do not route cables near other unshielded cables or near wiring carrying high voltage or high current. Cross cables at perpendicular intersections and avoid routing cables near motors and solenoids. Avoid mounting the Processor near sources of EMI
(electro-magnetic interference) or near devices that generate high ESD (electro-static discharge) levels. Always use adequate ESD prevention measures to dissipate potentially high voltages. If electrical interference is encountered (as indicated by a significant reduction in read/write performance), relocate the Processor to an area free from potential sources of interference. INSTALLATION The BIS U-620-068-1x1-00-Sx RFID Processor is designed for point-to-point RFID applications, where the distance from host to Processor is less than 15 meters (50 feet). The Processor connects directly to a serial communications port on a host computer via an RS232-compatible serial interface cable. 1. Select a suitable location for the BIS U-62 Processor and BIS U-30 Antenna. 2. Mount the BIS U-30 Antenna (within the cable distance of the Processor) and attach the BIS U-30 Antenna cable as described in the installation guide included with the antenna. 3. Fasten the Processor to your mounting fixture using two M5 (#10) diameter screws (not included) and secure them with appropriate washers and nuts. Tighten screws to 1.7 Nm or 15 lbs per inch 10%. Connect the antenna cable to the UHF Processor. 4. Connect the BCC0ETJM12 8-pin female connector to the M12 8-pin male interface connector on the BIS U-
620-068-1x1-00-Sx the BCC0ETJ9-pin female D-sub connector to an RS232 COM port on the host computer. Tighten the cables two locking thumbscrews. Processor. Connect 5. Connect the power supply to the VDC (red) and GND
(black) wires on the BCC0ETJcable. 6. Apply power to the Processor after all cable connections have been made. The LEDs on the unit will flash. The READY LED is ON after the power up sequence has completed. 7. On the host computer, set the COM port parameters to:
9600 baud, 8 data bits, 1 stop bit, no parity and no handshaking. To verify operations, download the Balluff Dashboard Configuration Tool from www.balluff.com. The Balluff Dashboard Configuration Tool allows users to configure and control their BIS U-620-068-1x1-00-Sx Processors and send RFID commands for testing purposes. See the BIS U-62_ Processor Manual for a complete list of accessories including alternative cables and connectors. DIGITAL I/O (-12 MODELS) DIMENSIONS M12 8-pin Female Connector (Digital I/O) This connector is available on models BIS U-620-068-1x1-00-S29. See the BIS U-62_ Processor Manual for details COMPL IANCE Only BIS U-30 family antennas are certified for use with the BIS U-620-068-1x1-00-Sx Processors. This product is intended to be installed by Qualified Personnel only. This product must not be used in explosive environments. Power Supply This device is intended to be supplied by a UL Listed or CSA Certified Power Unit with Class 2 or LPS power source. BIS U-620-068-101-00-Sx:
. 5 0 3 1 s e c a p e R l
. n o i t a c i f i d o m o t t c e b u S j
7 1 H
. N E 6 2 4 0 9 8
. o N zur Prfung BF-IDU07 BIS U-626-069-1X1-06-S3X Ultra High Frequency Passive Radio Frequency, Identification Processor INSTALLATION GUIDE This document provides information designed to assist users in the hardware setup of the BIS U-
626-069-1x1-06-S3x Processor . For configuration details see the BIS U-62_ Processor Manual. instructions and PACKAGE CONTENTS Qty 1 1 1 1 Description BIS U-626-069-1x1-06-S3x Processor UHF Series Configuration Tag This Installation Guide BCC06ZF Power Connector TECHNICAL DATA ELECTRICAL FEATURES Power Supply DC Input Current Communication Interface Baud Rate RADIO FEATURES Frequency (MHz) ETSI EN 302 208 FCC part 15.247 Number of Channels Frequency Tolerance Air Interface Conducted Output Power Antenna Connector ENVIRONMENTAL FEATURES Operating Temperature Storage Temperature Humidity max. Vibration Resistance EN 60068-2-6 Shock Resistance EN 60068-2-27 Protection Class EN 60529 PHYSICAL FEATURES Dimensions Weight Enclosure USER INTERFACE LED Indicators 19.228.8 V DC 1 A Industrial Ethernet, TCP/IP, MODBUS TCP 10/100 Mbps EU 865868 US
902928 50 hopping 10 ppm over entire temp 4 fixed range EPC C1G2 500 mW (27 dBm) max Reverse TNC
-20+50 C
(-4+122 F)
-20+70 C
(-4+158 F) 90% non condensing 14 mm @ 210 Hz;
1.5 mm @ 1355 Hz;
2 g @ 70200 Hz;
2 hours on each axis 30 g; 11 ms;
3 shocks on each axis IP65 164 x 112 x 48 mm
(6.46 x 4.41 x 1.88 in) 560 g (19.8 oz) Powder Coated Aluminum READY, RF, COM, DEFAULT IP, CUSTOM IP GENERAL VIEW LED INDICATORS INSTALLATION GUIDELINES green amber READY The READY LED is ON after the power up sequence has completed. RF The RF LED illuminates when RF power the antenna. transmitted by is being amber COM
(communications) LED The COM flashes ON and OFF when data is being transmitted between the antenna and a tag. When in Continuous Read mode, the COM LED will remain ON and will turn OFF briefly only while data is being read from or written to a tag. amber amber DEFAULT Default IP Address enabled
(192.168.253.110) CUSTOM User assigned IP Address enabled 9 6 0
6 2 6
U S B I CONNECTIVITY M12 4-pin D-Coded Female Connector (for Ethernet) BIS U-30x antenna Typical Layout M12 5-pin Male Connector (for Power Supply) BCC0CT1 PIN 4:
RX-
PIN 4:
N/C PIN 1:
TX+
PIN 2:
RX+
PIN 3:
GND PIN 2:
VDC PIN 3:
TX-
PIN 5:
N/C PIN 1:
N/C DIGITAL I/O (-12 MODELS) M12 8-pin Female Connector (Digital I/O) See the BIS U-62_ Processor Manual for a complete list of accessories including alternative cables and connectors. DIMENSIONS BCC06ZF Vdc GND to Power Supply PLC Hub
mm in
* Digital I/O (-S32 models only)
RF performance and read/write range can be negatively impacted by the proximity of metallic objects and liquids. Avoid mounting the BIS U-3x antenna within 15 cm (6 inches) of any metallic object or wet surface. Do not route cables near other unshielded cables or near wiring carrying high voltage or high current. Cross cables at perpendicular intersections and avoid routing cables near motors and solenoids. Avoid mounting the Processor near sources of EMI
(electro-magnetic interference) or near devices that generate high ESD (electro-static discharge) levels. Always use adequate ESD prevention measures to dissipate potentially high voltages. If electrical interference is encountered (as indicated by a significant reduction in read/write performance), relocate the Processor to an area free from potential sources of interference. INSTALLATION The BIS U-626-069-1x1-06-S3x Processor is designed for Industrial Ethernet RFID applications, where the Processor is connected in an Industrial Ethernet or TCP/IP network via compatible cables through a hub or directly to an Industrial Ethernet host. 1. Select a suitable location for the BIS U-62 Processor and BIS U-30 Antenna. 2. Mount the BIS U-30 Antenna (within the cable distance of the Processor) and attach the BIS U-30 Antenna cable as described in the installation guide included with the antenna. 3. Fasten the Processor to your mounting fixture using two M5 (#10) diameter screws (not included) and secure them with appropriate washers and nuts. Tighten screws to 1.7 Nm or 15 lbs per inch 10%. Connect the antenna cable to the UHF Processor . 4. Connect the BCC0CT1 M12 4-pin male connector to the M12 4-pin female interface connector on the BIS U-
626-069-1x1-06-S3x Processor. Connect the BCC0CT1 RJ45 male connector If connecting directly to the host computer you will need to use an additional crossover cable. the LAN hub/switch. to 5. Build a power supply cable using the BCC06ZF M12 5-
pin female connector. Use minimum 24 AWG wires for connection to the power supply lines according to the Vdc connector pinout. Connect the BCC06ZF M12 5-
pin female connector to the M12 5-pin male connector on the Processor . Connect the other end of the cable
(wires or user-supplied connectors) the power supply. to 6. Apply power to the Processor after all cable connections have been made. The LEDs on the unit will flash. The READY LED is ON after the power up sequence has completed. Then one of the Industrial Ethernet Address LEDs will remain on either Default or Custom. To verify operations, download the Balluff Dashboard Configuration Tool from www.balluff.com. The Balluff Dashboard Configuration Tool allows users to configure and control their BIS U-626-069-1x1-06-S3x Processor s and send RFID commands for testing purposes. For connection details see the BIS U-62_ Processor Manual and the Balluff Dashboard Configuration Tool Manual.
* When all connectors and antenna are correctly installed. The BIS U-626-069-1x1-06-S3x Processor and antenna are intended for indoor use only its This connector is available on models BIS U-620-067-1x1-04-S32. See the BIS U-62_ Processor Manual for details. COMPL IANCE Only BIS U-30 family antennas are certified for use with the BIS U-626-069-1x1-06-S3x Processors. This product is intended to be installed by Qualified Personnel only. This product must not be used in explosive environments. Only connect Ethernet and dataport connections to a network which has routing only within the plant or building and no routing outside the plant or building. Power Supply This device is intended to be supplied by a UL Listed or CSA Certified Power Unit with Class 2 or LPS power source. BIS U-626-069-101-06-S3x:
. 5 0 3 1 s e c a p e R l
. n o i t a c i f i d o m o t t c e b u S j
7 1 H
. N E 8 2 4 0 9 8
. o N