BARCO LTD. 33F., No. 16 &No.16-1, Xizhan Rd., Banqiao Dist., New Taipei City 220, Taiwan (R.O.C.) Telephone: +886-2-7715-0299 Fax: +886-2-7715-0298 BARCO Panel PC JAO15/ JAO18 User Manual Version: 1.2 CCCContent Preface ........................................................................................................... 3 Copyright ................................................................................................ 3 Disclaimer .............................................................................................. 3 Acknowledgements ............................................................................... 3 Regulatory Compliance Statements....................................................... 3 Declaration of Conformity ..................................................................... 3 RoHS Compliance ........................................................................................... 4 Safety Precautions ......................................................................................... 6 Technical Support and Assistance .................................................................. 7 Conventions Used in this Manual .................................................................. 7 Ordering Information ................................................................................... 10 Chapter 1: Product Introduction .................................................................. 11 JAO15 ................................................................................................... 11 JAO18 ................................................................................................... 14 IO introduction ............................................................................................. 17 Mechanical Dimensions ............................................................................... 19 JAO15 ................................................................................................... 19 JAO18 ................................................................................................... 19 Chapter2: Jumpers and Connectors ............................................................. 20 Before you Begin .................................................................................. 20 Jumper Setting ..................................................................................... 21 Interactive Patient Care Barco Healthcare Division Locations of the Jumpers and Connectors ................................................... 22 Top View ............................................................................................... 22 Jumpers and DIP Switch Setting ................................................................... 22 CMOS Clear Select ................................................................................ 22 Connector Pin Definition .............................................................................. 23 External I/O Interface ........................................................................... 23 19V DC Power Input ..................................................................... 23 REAR IO USB PORT ....................................................................... 23 Service Call connector .................................................................. 24 Line-out Jack ................................................................................. 25 Internal Connectors .............................................................................. 26 SATA .............................................................................................. 26 Mini-PCIe Slot ............................................................................... 27 Block Diagram .......................................................... !
Chapter 3: System Setup ...................................................................... 28 Replace SATA Disk ................................................................................. 28 Replace RAM ........................................................................................ 28 Install Handset .................................................. !
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Preface Copyright This publication, including all photographs, illustrations and software, is protected under international copyright laws, with all rights reserved. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written consent from BARCO. Disclaimer The information in this document is subject to change without prior notice and does not represent commitment from BARCO International Co., Ltd. However, users may update their knowledge of any product in use by constantly checking its manual posted on our website:
http://www.barco.com. BARCO shall not be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of any product, nor for any infringements upon the rights of third parties, which may result from such use. Any implied warranties of merchantability or fitness for any particular purpose is also disclaimed. Interactive Patient Care Barco Healthcare Division Acknowledgements ST156B/ST185D is a trademark of BARCO. All other product names mentioned herein are registered trademarks of their respective owners. Regulatory Compliance Statements This section provides the FCC compliance statement for Class A devices and describes how to keep the system CE compliant. Declaration of Conformity FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care Barco Healthcare Division However, there is no guarantee that interference will not occur in a European Union (CE) directives if it has a CE marking. For computer systems particular installation. If this equipment does cause harmful interference to remain CE compliant, only CE-compliant parts may be used. Maintaining to radio or television reception, which can be determined by turning the CE compliance also requires proper cable and cabling techniques. equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna.
Connect the equipment into an outlet on a circuit different from that Increase the separation between the equipment and receiver. to which the receiver is connected. IEC/ISO All components and wirings comply with IEC or ISO standard, except for Plastic Enclosure is UL approved only RoHS Compliance
Consult the dealer or an experienced radio/TV technician for help. BARCO RoHS Environmental Policy and Status
. FCC Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Update This publication, including all photographs, illustrations and software, is protected under international copyright laws, with all rights reserved. No part of this manual may be reproduced, copied, translated or transmitted
This transmitter must not be co-located or operating in conjunction in any form or by any means without the prior written consent from with any other antenna or transmitter. BARCO. Radiation Exposure Statement:
RoHS restricts the use of Lead (Pb) < 0.1% or 1,000ppm, Mercury (Hg) <
0.1% or 1,000ppm, Cadmium (Cd) < 0.01% or 100ppm, Hexavalent This equipment complies with FCC radiation exposure limits set forth for an Chromium (Cr6+) < 0.1% or 1,000ppm, Polybrominated biphenyls (PBB) <
uncontrolled environment. This equipment should be installed and 0.1% or 1,000ppm, and Polybrominated diphenyl Ethers (PBDE) < 0.1% or operated with minimum distance 20cm between the radiator & your body. 1,000ppm. CE In order to meet the RoHS compliant directives, BARCO has established an engineering and manufacturing task force to implement the introduction of The product(s) described in this manual complies with all applicable green products. The task force will ensure that we follow the standard CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry quality levels for which BARCO are renowned. The model selection criteria will be based on market demand. Vendors and suppliers will ensure that all designed components will be RoHS compliant. Interactive Patient Care Barco Healthcare Division CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care Barco Healthcare Division 12. Never pour any liquid into an opening. This may cause fire or electrical shock. 13. Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel. 14. If one of the following situations arises, get the equipment checked by service personnel:
i. ii. iii. iv. The power cord or plug is damaged. Liquid has penetrated into the equipment. The equipment has been exposed to moisture. The equipment does not work well, or you cannot get it to work according to the users manual. v. vi. The equipment has been dropped and damaged. The equipment has obvious signs of breakage. 15. Do not place heavy objects on the equipment. 16. The system follows the national requirement to dispose unit Safety Precautions Read these safety instructions carefully. 1. 2. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp Keep this User Manual for later reference. 4. 5. 6. 7. cloth. Do not use liquid or spray detergents for cleaning. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. Keep this equipment away from humidity. Put this equipment on a stable surface during installation. Dropping it or letting it fall may cause damage. The openings on the enclosure are for air convection to protect the equipment from overheating. DO NOT COVER THE OPENINGS. 8. Make sure the voltage of the power source is correct before connecting the equipment to the power outlet. 9. Place the power cord in a way so that people will not step on it. Do not place anything on top of the power cord. Use a power cord that has been approved for use with the product and that it matches the voltage and current marked on the products electrical range label. The voltage and current rating of the cord must be greater than the voltage and current rating marked on the product. 10. All cautions and warnings on the equipment should be noted. 11. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Technical Support and Assistance 1. For the most updated information of products, visit Barco website at www.barco.com. 2. For technical issues that require contacting our technical support team or sales representative, please have the following information ready before calling:
Product name and serial number Interactive Patient Care Barco Healthcare Division Warning 1. Manipulation de l'appareil : raliser l'unit avec les deux mains et manipuler avec soin . 2. Entretien: Pour garder l'unit propre, utilise des produits de nettoyage approuvs ou nettoyer avec un chiffon sec . 3. Pour viter tout risque de choc lectrique , cet quipement ne doit tre connect une alimentation avec de la terre de protection 4. Ne pas modifier cet quipement sans l'autorisation du constructeur Detailed information of the peripheral devices Detailed information of the installed software (operating system, version, application software, etc.) A complete description of the problem The exact wordings of the error messages Warning 1. Handling the unit: carry the unit with both hands and handle it with care. 2. Maintenance: to keep the unit clean, uses only approved cleaning products or clean with a dry cloth. 3. To avoid risk of electric shock, this equipment must only be connected to a supply with protective earth 4. Do not modify this equipment without authorization of the manufacturer. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care Barco Healthcare Division Conventions Used in this Manual Warning:
Information about certain situations, which if not observed, can cause personal injury. This will prevent injury to you when performing a task. Caution:
Information to avoid damaging components or losing data. Note:
Provides additional information to complete a task easily CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Symbol Glossary There are some symbols marks on user manual, label, carton and product, each symbol has its purpose, please take notice the symbol identification before use. Interactive Patient Care Barco Healthcare Division Network The system support 10/100/1000 Mbps Ethernet connection. Line out 3.5mm earphone jack supports line out signal. Book mark Read the manual before start operate the system HDMI HDMI signal, the system support HDMI input on this port Power key Power key use to control system status such as reset or set enable panel backlight. RFID and SMC This system work with contact and contactless reader. Service call The system has 4pin service call. It connects to back end service system with 4 wire signal pin USB Usb port symbol. The system support USB2.0 IO. GND Ground pin for system.
(Panel PC with external power supply: class II with functional earth equipment) AC power symbol Information for AC power input range of PSU DC power symbol Information for DC power input range of system CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Ordering Information The following information below provides ordering information. JAO 15 / ST156BIPC000 (P/N: 10Q0ST15600X1) Interactive Patient Care Barco Healthcare Division 15.6 bedside terminal, Intel Bay Trail J1900 2.0GHz, resistive touch screen, 2GB DDR3L, 32GB MLC SSD, 13.56MHz RFID and smart card reader
JAO18/ ST185DIPC000 (P/N: 10Q0ST18500X1) 18.5 bedside terminal, Intel Bay Trail J1900 2.0GHz, PCAP touch screen, 2GB DDR3L, 32GB MLC SSD, 13.56MHz RFID and smart card reader
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Product Introduction JAO15 Overview JAO 15 is designed to serve as a Point of Care (POC) and Point of Information terminal (POI) within healthcare applications. Manufactured using anti-bacterial plastics, the terminals provide a host of interactive healthcare applications providing secure access to Electronic Medical Records (EMR) and innovative triple-play solutions (web, IPTV, VoIP) for patient entertainment. Interactive Patient Care Barco Healthcare Division
Flat Panel by Resistive Touch Screen
With 1x GbE/ HDMI input/ 5x USB ports
Built in speaker/ microphone/ 2x line out
13.56MHz RFID/ Smart card reader
DDR3L 2GB/ 2.5 32GB SSD
System Power Input 19V DC Key Features 16:9 15.6 1366x768 Fanless LED Panel Computer Intel Celeron J1900, Quad Core, Low Consumption CPU
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Specification Panel
- LED size: 15.6, 16:9
- Resolution: 1366x768
- Luminance: 300 cd/m2
- Contrast ratio: 500
- LED color: 16.7M
- Viewing Angle: 80(U) 80(D) 80(L) 80(R)
- Backlight: LED Touch Screen
- 5 wire Resistive touch
- Light transmission: 78%
-
System
- CPU: On-board Intel Celeron J1900, 2.0GHz,2M L2 Cache
- BIOS: AMI BIOS
-
- System memory: 1x 204-pin DDR3L SO-DIMM socket, 2G IO chipset: ITE 8786 Interface: USB DDR3L (Default), support up to 8GB DDR3L-1333, Non-ECC and un-buffered
- Storage Device: 1x 2.5 SATA HDD Interactive Patient Care Barco Healthcare Division
- Watchdog timer: Watchdog timeout can be programmed by software. from 1 second to 255 seconds and from 1 minute to 255 minutes
(Tolerance 15% under room temperature 25C)
- H/W status monitor: Monitoring system temperature, and voltage
- Expansion: 1x mini-PCIe sockets I/O
- Ethernet: 1x RJ45
- USB: 5 x USB 2.0
- Audio port: 2x Line out/built in speaker and microphone
- HDMI input connector
- Front touch icon
- 720p camera Audio
- HDA codec: Realtek ALC886-GR
- Audio interface: Line out Audio Jack Ethernet
- LAN chip: Intel I210AT Gigabit LAN
- Ethernet interface: 10/100/1000 Based-Tx Ethernet compatible Wifi & BT (optional) CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.
- Certified module BOINTE PE809-AA
- Support 802.11 b/g/n
- Support BT 4.0 Mechanical & Environment
- Color: white, pantone RAL9016
- Vibration:
IEC 68 2-64 (w/ HDD)
1Grms @ sine, 5~500Hz, 1hr/axis (HDD Operating)
- Shock:
IEC 68 2-27 HDD: 20G@panel mount, half sine, 11ms
- Operating temperature: 0C to 40C
- Storage temperature: -20C to 60C
- Operating/Storage humidity: 20%~80% relative humidity, non-condensing
- The humidity preconditioning treatment is performed in a humidity cabinet containing air with a relative humidity of 93%RH @25C 48hrs
- Storage Altitude: up to 3000M
- Dimension: 417.2x 266.6x50 mm
- Weight: 4.5 Kg Power Supply
- Model: DELTA MDS-090AAS19 B Interactive Patient Care Barco Healthcare Division
- Power input: 100-240V~ 1.5-0.75A 50-60Hz
- Power Output: 19VDC, 4.74A IEC 60950-1 CB Certifications
- CE
- FCC class B
- EN60601-1
- UL60601-1
-
- ANSI/AAMI ES60601-1*
- CAN/CSA-C22.2 No.60601-1*
* This panel pc incorporates the ES60601-1 /IEC60601-1 certified power supply, Model MDS-090AAS19 B is by DELTA. The power supply is used in the conditions of overvoltage category II, Pollution Degree II.
*This panel pc incorporates the power supply is Class II with functional earth AC/DC Adapter intended for supplying medical electrical apparatus with two parts of plastic enclosure fixed together by screws CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. JAO18 Overview JAO 18 is designed to serve as a Point of Care (POC) and Point of Information terminal (POI) within healthcare applications. Manufactured using anti-bacterial plastics, the terminals provide a host of interactive healthcare applications providing secure access to Electronic Medical Records (EMR) and innovative triple-play solutions (web, IPTV, VoIP) for Interactive Patient Care Barco Healthcare Division Key Features
16:9 18.5 1366x768 Fanless LED Panel Computer Intel Celeron J1900, Quad Core, Low Consumption CPU Flat Panel by PCAP Touch Screen patient entertainment.
With 1x GbE/ HDMI input/ 5x USB ports
Built in speaker/ microphone/ 2x line out
13.56MHz RFID/ Smart card reader
DDR3L 2GB/ 2.5 32GB SSD
System Power Input 19V DC CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Specification Panel
- LED size: 18.5, 16:9
- Resolution: 1366X768
- Luminance: 300 cd/m2
- Contrast ratio: 1000
- LED color: 16.7M
- Viewing Angle: 80(U) 80(D) 85(L) 85(R)
- Backlight: LED Touch Screen
- PCAP touch
- Light transmission: 87%
-
System
- CPU: On-board Intel Celeron J1900, 2.0GHz,2M L2 Cache
- BIOS: AMI BIOS
-
- System memory: 1x 204-pin DDR3L SO-DIMM socket, 2G IO chipset: ITE 8786 Interface: USB DDR3L (Default), support up to 8GB DDR3L-1333, Non-ECC and un-buffered
- Storage Device: 1x 2.5 SATA HDD Interactive Patient Care Barco Healthcare Division
- Watchdog timer: Watchdog timeout can be programmed by software. from 1 second to 255 seconds and from 1 minute to 255 minutes
(Tolerance 15% under room temperature 25C)
- H/W status monitor: Monitoring system temperature, and voltage
- Expansion: 1x mini-PCIe sockets I/O
- Ethernet: 1x RJ45
- USB: 5 x USB 2.0
- Audio port: 2x Line out/built in speaker and microphone
- HDMI input connector
- Front touch icon
- 720p camera
- Optional barcode scanner (IEC62471 certified) Audio
- HDA codec: Realtek ALC886-GR
- Audio interface: Line out Audio Jack Ethernet
- LAN chip: Intel I210AT Gigabit LAN
- Ethernet interface: 10/100/1000 Based-Tx Ethernet compatible Wifi & BT (optional) CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.
- Certified module BOINTE PE809-AA
- Support 802.11 b/g/n
- Support BT 4.0 Mechanical & Environment
- Color: white, pantone RAL9016
- Vibration:
IEC 68 2-64 (w/ HDD)
1Grms @ sine, 5~500Hz, 1hr/axis (HDD Operating)
- Shock:
IEC 68 2-27 HDD: 20G@panel mount, half sine, 11ms
- Operating temperature: 0C to 40C
- Storage temperature: -20C to 60C
- Operating/Storage humidity: 20%~80% relative humidity, non-condensing
- The humidity preconditioning treatment is performed in a humidity cabinet containing air with a relative humidity of 93%RH @25C 48hrs
- Storage Altitude: up to 3000M
- Dimension: 481.6x308.2x50 mm
- Weight: 4.7 Kg Power Supply
- Model: DELTA MDS-090AAS19 B Interactive Patient Care Barco Healthcare Division
- Power input: 100-240V~ 1.5-0.75A 50-60Hz
- Power Output: 19VDC, 4.74A IEC 60950-1 CB Certifications
- CE
- FCC class B
- EN60601-1
- UL60601-1
-
- ANSI/AAMI ES60601-1*
- CAN/CSA-C22.2 No.60601-1*
* This panel pc incorporates the ES60601-1 /IEC60601-1 certified power supply, Model MDS-090AAS19 B is by DELTA. The power supply is used in the conditions of overvoltage category II, Pollution Degree II.
*This panel pc incorporates the power supply is Class II with functional earth AC/DC Adapter intended for supplying medical electrical apparatus with two parts of plastic enclosure fixed together by screws CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. IO introduction Front side Interactive Patient Care Barco Healthcare Division Camera 720p camera with white LED RFID and smart card reader 13.56MHz RFID and smart card reader. RFID tag also readable while parking in smart card reader slot Power Key Touch icon input. Long press 5 seconds to turn on panel backlight; long press 10 seconds to reset or power off system. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care Barco Healthcare Division Microphone Built in digital microphone Speaker Built in stereo speaker Back side HDD service door Lock with Torx screws, use for SSD replacement RAM and miniPCIe service door Lock with Torx screws, use for RAM replacement or install extension module Rear IO 19V DC input Service call connect to PSU connect to back end service system (intra network) with 4 wire signal pin 3x USB 2.0 ports Gigabit Ethernet USB LAN Bottom IO Line out USB HDMI Barcode Scanner (optional) Optional install 1D/2D supported barcode scanner module 2x line out jack 2x USB 2.0 ports with 1.5A V use as HDMI input CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Mechanical Dimensions Interactive Patient Care Barco Healthcare Division JAO15 JAO18 CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Jumpers and Connectors Interactive Patient Care Barco Healthcare Division This chapter describes how to set the jumpers and connectors on the metal object. Static electricity can damage many of the electronic motherboard. Before you Begin components. Humid environments tend to have less static electricity than dry environments. A grounding strap is warranted whenever danger of static electricity exists. Precautions
Ensure you have a stable, clean working environment. Dust and dirt can get into components and cause a malfunction. Use containers to keep small components separated. Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still Adequate lighting and proper tools can prevent you from accidentally connected to a power supply can be extremely dangerous. damaging the internal components. Most of the procedures that follow Follow the guidelines below to avoid damage to your computer or yourself:
A Philips screwdriver A flat-tipped screwdriver require only a few simple tools, including the following:
-
-
-
-
-
A set of jewelers screwdrivers A grounding strap An anti-static pad Using your fingers can disconnect most of the connections. It is recommended that you do not use needle-nosed pliers to disconnect connections as these can damage the soft metal or plastic parts of the connectors. Before working on internal components, make sure that the power is off. Ground yourself before touching any internal components, by touching a
Always disconnect the unit from the power outlet whenever you are working inside the case. To fully disengage the power to the unit, please disconnect the power cord from the AC inlet. If possible, wear a grounded wrist strap when you are working inside the computer case. Alternatively, discharge any static electricity by touching the bare metal chassis of the unit case, or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only. Do not touch the components on the board unless it is necessary to do so. Dont flex or stress the circuit board. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care Barco Healthcare Division
Leave all components inside the static-proof packaging that they shipped with until they are ready for installation. Use correct screws and do not over tighten screws. Jumper Setting A jumper is the simplest kind of electric switch. It consists of two metal pins and a cap. When setting the jumpers, ensure that the jumper caps are placed on the correct pins. When the jumper cap is placed on both pins, the jumper is short. If you remove the jumper cap, or place the jumper cap on just one pin, the jumper is open. Refer to the illustrations below for examples of what the 2-pin and 3-pin jumpers look like when they are short (on) and open (off). Two-Pin Jumpers: Open (Left) and Short (Right) Three-Pin Jumpers: Pins 1 and 2 are Short CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care Barco Healthcare Division Locations of the Jumpers and Connectors Top View Jumpers and DIP Switch Setting CMOS Clear Select Connector type: 1x3 3-pin header, 2.54mm pitch Connector location: JBIOS1 Pin 1-2 ON 2-3 ON Settings Normal Clear BIOS CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Connector Pin Definition External I/O Interface 19V DC Power Input Connector type: 5.5mm DC jack Interactive Patient Care Barco Healthcare Division HDMI Input Port Connector type: HDMI Female connector Pin Definition Pin Definition 11 12 13 14 15 16 17 18 19 TMDS Clock Shield TMDS Clock CEC N.C SCL SDA DDC/CEC Ground
+5 V Power Hot Plug Detect 1 2 3 4 5 6 7 8 9 TMDS Data2+
TMDS Data2 Shield TMDS Data2 TMDS Data1+
TMDS Data1 Shield TMDS Data1 TMDS Data0+
TMDS Data0 Shield TMDS Data0 10 TMDS Clock+
REAR IO USB PORT Connector type: USB type A female CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Definition VCC5 USB 0-
USB 0+
GND Interactive Patient Care Barco Healthcare Division Service Call connector Connector type: 6 pin RJ 11 connector Service call Pin 2 3 4 5 Definition Service call +
Service call -
Handset LED +
Handset LED -
USB Pin 1 2 3 4 CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care Barco Healthcare Division Pin 1 2 3 4 5 6 Definition LOUT_R JD NC LOUT_L GND GND LAN Ports Connector type: RJ45 port with LEDs ACT Status Yellow blinking Data activity Off No activity LINK Status Steady green 1000M link Steady orange 100M link Off 10M or no link Pin Definition Pin Definition 1 2 3 4 LAN M0+
LAN M0-
LAN M1+
LAN M2+
5 6 7 8 LAN M2-
LAN M1-
LAN M3+
LAN M3-
Line-out Jack Connector type: 3.5mm Earphone Jack CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care Barco Healthcare Division Internal Connectors SATA Connector location: SATA1 Pin S1 S3 S5 S7 P2 P4 P6 P8 P10 P12 P14 Signal GND SATA_TX0N SATA_RX0N GND VCC3 GND GND VCC5 GND GND VCC12 Pin S2 S4 S6 P1 P3 P5 P7 P9 P11 P13 P15 Signal SATA_TX0P GND SATA_RX0P VCC3 VCC3 GND VCC5 VCC5 NC VCC12 VCC12 CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Mini-PCIe Slot Connector location: CN2 Interactive Patient Care Barco Healthcare Division Pin 1 3 5 7 9 11 13 15 17 19 21 23 25 Signal WAKE0#
NC NC PCIE_CLKREQ GND GPP_CLK1-
GPP_CLK1+
GND NC NC GND PCIE_RX2-
PCIE_RX2+
Pin Signal 2 4 6 8 10 12 14 16 18 3.3V_MINI GND 1.5V_MINI NC NC NC NC NC GND 20 MINICARD1_DIS#
22 24 26 PCIE_RST#
3.3V_MINI GND Pin 27 29 31 33 35 37 39 41 43 45 47 49 51 Signal GND GND PCIE_TX3-
PCIE_TX3+
GND GND
+3.3V_MINI
+3.3V_MINI GND NC NC NC NC Pin Signal 28 30 32 34 36 38 40 42 44 46 48 50 52
+1.5V_MINI SMB_CLK SMB_DAT GND USB-
USB+
GND NC NC NC
+1.5V_MINI GND
+3.3V_MINI CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. System Setup Interactive Patient Care Barco Healthcare Division Prior to removing the chassis cover, make sure the units power is off and disconnected from the power sources to prevent electric shock or system Replace SATA Disk damage. To fully disengage the power to the unit, please disconnect the power cord from the AC inlet Avant de retirer le capot du chssis , assurez-vous que la puissance de 1. Loose the screw of HDD service door. 2. Remove current SATA and replace with new one. l'appareil est teint et dconnect de la source d'alimentation pour viter un choc lectrique ou d'un systme de dgts. Pour dgager pleinement la puissance l'unit , s'il vous plat dbrancher le cordon d'alimentation de la prise secteur System setup and use in different environment. In normal use condition, System button IO is toward to ground for better system performance. In which means system usually install where panel face to user. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Replace RAM 1. Loose the screw of RAM service door. 2. Remove DDR3L RAM module and replace with new one. 3. Interactive Patient Care Barco Healthcare Division CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. System Mounting There are different mount types to fix system in bracket or arm. In system Interactive Patient Care Barco Healthcare Division accessory pack, there are 4 M4 screws. Length of screw teeth should be 5mm. Screw should be fasten to back cover by 8KG torque. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.