H S I L G N E 900 MHZ RECEIVER & INDUSTRIAL TRANSMITTERS Digital transmitters and receiver with frequency hopping, sequencing and extended hold functionality
(US version) DESCRIPTION 3 4 5 2 10 1 6 8 9 7 1. receiver (10RD900) 2. antenna wire 3. blue activation LED 4. red learn LED 5. tri-color signal strength LED 6. DIP switches 7. no-delay learn button 8. delay learn button 9. delay learn potentiometer 10. transmitter HAND HELD TRANSMITTERS 1 BUTTON 2 BUTTON 3 BUTTON 4 BUTTON IMPORTANT:
This product is NOT intended for use directly with Magnetic Locks or Electric Strikes. Contact BEA Technical Support for further information. 75.5858.02 900 MHZ INDUSTRIAL 20160205 Page 1 of 4 PRECAUTIONS q Shut off all power going to header before attempting any wiring procedures. q Maintain a clean & safe environment when working in public areas. q Constantly be aware of pedestrian traffic around the door area. q Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door. q ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board ensure you dissipate your bodys ESD charge. q Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment. q Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation. q DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock. 2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty. The device should not be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer of this device. The installer of the door system is responsible for carrying out a risk assessment and installing this device and the door system in compliance with applicable national and international regulations and standards on door safety. The manufacturer of this device cannot be held responsible for incorrect installations or inappropriate adjustments of this device. INSTALLATION Wiring TERMINAL:
1 2 LABEL:
12-24 V 12-24 V WIRE COLOR:
red black 3 COM white 4 NO green 5 NC yellow SIGNAL:
+ voltage
- voltage common normally-open normallyclosed DESCRIPTION:
power relay contacts SETUP DIP Switches DIP STATUS FUNCTION DESCRIPTION PUL Pulse Relay pressing transmitter activates and holds relay according to DIP 2 and 3 1 2
(PUL only) 3 TOG 0.5s 10s STD EH Toggle Relay pressing transmitter once activates and holds relay indefinitely pressing transmitter again deactivates relay immediately (no hold) 0.5 second hold time 10 second hold time relay remains active for 0.5 seconds after transmitter is... pressed [STD] released [EH]
relay remains active for 10 seconds after transmitter is... pressed [STD] released [EH]
standard relay acts according to DIP 1 and 2 hold
(does not matter if transmitter is pressed/released or pressed/held) extended relay remains active as long as transmitter is pressed and held hold once released, relay acts according to DIP 1 and 2 Hand Held Configuration 1 ON 1 2 3 2 3 Set DIP switches as desired. Press and release desired learn button
(red LED on receiver will illuminate)1. Press transmitter twice (blue LED on receiver will illuminate). NOTES: 1If Learn w/ Delay button is used, adjust potentiometer (1 s to 30 s). Page 2 of 4 75.5858.02 900 MHZ INDUSTRIAL 20160205 Removing Transmitters Single Transmitter 1 2 All Transmitters 1 x2 Press BOTH learn buttons until red LED flashes once (~2 s). Press transmiter TWICE within 10 seconds. Press BOTH learn buttons until blue LED illuminates (~10 s). Battery Replacement Handheld (TD900INDHHx) 1 2 3 V 3 V Remove back three (3) screws and disassemble. Replace two (2) 3V (CR2032) batteries observing polarity and reassemble. Low Battery Indicator - After transmitter button is pressed, low battery is indicated by three (3) transmitter LED blinks. NOTE: All transmitters must ONLY be powered with provided batteries or equivalent. SINGAL STRENGTH INDICATION Pressing and hold transmitter button for at least 5 seconds activates singal strength tri-color LED on receiver Green LED on Strong signal Yellow LED on Medium signal Red LED on Weak signal TROUBLESHOOTING red LED on receiver flickering; unable to program stuck push plate faulty transmitter disconnect push plates to determine which is stuck (LED should go out) if LED does not go out, remove transmitter batteries to determine which is faulty, replace transmitter weak signal receiver antenna positioned poorly position antenna outside of door header 75.5858.02 900 MHZ INDUSTRIAL 20160205 Page 3 of 4 TECHNICAL SPECIFICATIONS Frequency:
908-918 MHz (frequency hopping) Emitted radio power:
-25 dBm (TX) Power consumption:
Supply voltage:
Contact rating:
13 mA (Transmitter) 40mA (Receiver) 12-24 VAC/DC 1.0 A @ 30 VDC 0.5 A @ 125 VAC 0.3 A @ 60 VDC Temperature range:
14F to 131F (-10C to 55C) Programmable units per receiver:
74 LEDs:
Dimensions:
red (receiver learn) blue (relay activation) tri-color (signal strength) 2.5 (W) x 2.0 (D) x 0.75 (H) [RD900]
1.5 (W) x 3.0 (D) x 0.5 (H) [Transmitter]
I G N T N R P I I R O L O C R O F D E N G S E D E S U R E H T R U F Transmitter Protection Rate Certification:
IP65 FCC, IC R O F P E E K E S A E L P Specifications are subject to changes without prior notice. All values measured in specific conditions I 5 0 2 0 6 1 0 2 L A R T S U D N I Z H M 0 0 9 2 0 8 5 8 5 5 7
|
s n o i t c u r t s n
. I l a n g i r i
|
O A E B FCC / IC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by BEA Incorporated could void the users authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. FCC ID: 2ABWS-10RD900 IC: 4680A-10RD900 MODEL: 10RD900 FCC ID:
FCC ID:
FCC ID:
FCC ID:
IC:
IC:
IC:
IC:
MODEL: 10TD900INDHH1 MODEL: 10TD900INDHH2 MODEL: 10TD900INDHH3 MODEL: 10TD900INDHH4 Page 4 of 4 75.5858.02 900 MHZ INDUSTRIAL 20160205