EC-210 Product Instruction of Elite Care (EC-210) 1. Product Presentation ................................................................................................ 2 2. Powering On .......................................................................................................... 3 3. Installation Guide ...................................................................................................... 4 4. Correct Laying Method .................................................................................... 5 5. APP Install APP .................................................................................................................. 5 6. Parameter List ........................................................................................................... 5 7. Operating Environment ............................................................................................ 6 8. Safety Attentions ....................................................................................................... 7 9. Manufacturer .............................................................................................................. 11 10. Product Usage ........................................................................................................... 8 11. Matters Need Attention With Transportation ................................................... 8 12. Software Operation Information ....................................................................... 8 13. Noise Information ................................................................................................... 10 14. Product Fault Treatment .................................................................................. 10 15. Product Scrapping Treatment .......................................................................... 10 16. Maintenance ........................................................................................................... 10 1 1. Product Presentation EC-210 20 The Elite Care EC-210 is for people over 20 years old. According to deep sleep data, we foresee the cardiovascular function is normal or not. Then we give the quantized cardiovascular IWB, calculate the sleep stage and evaluate the quality of sleep. Connecting a phone or a pad by Bluetooth can observe the test results at anytime and in anywhere.Its easy to carry, the packaging is fashion and its the best choice for health. characteristic contactless, unconstrained, automatic collection of information Easy to set, easy to carry, can be carried when you travel APP 30 The data exists in the APP and you can watched at anytime(the device is stored for 30 days) Product structure controller box monitoring belt power cord 1 2 3 Accessories: 1Instructions 2Warranty Card 3Operating Guide 2 2. Powering On Connect the source and enjoy it 3 3. Installation Guide Spread the monitor belt and cover the bed sheet Connect the source Enjoy healthy sleep Flexural flexible zone the correct position of the flexural flexible zone 4 4. Correct Laying Method Lay the monitoring pad between the bed sheet and the mattress The position of monitoring pad is on an even height with the human chest 5. APP Install APP method one: scan QR Code to download quickly method two: download in Android Market 6. Parameter List control box 84.56mm 70mm 7.75mm 84.56mm(W) 70mm(H) 7.75mm(D) monitor 820mm 64.5mm 2.5mm belt weight input voltage power rating 820mm(W) 64.5mm(H) 2.5mm(D) 150g 5V DC 1W less than 1W 5 service temperature storage temperature service humidity communication mode communication distance 5 - 45
-30 - 60 30% - 90%
30% - 90% no dewing BLE Bluetooth BLE protocol 20 20 meters indoor 5.0 BLE software system Android system 5.0 and above, in addition with BLE function 7. Operating Environment The best use environment of this product: laying on the mattress, under the bed sheet Do not suggest to use mahjong mat, bamboo mat. The product can be laid on ice silk mat, dose not affect the use. We are not suggested to put the thing over thickness between the monitor belt and the human body. 6 8. Safety Attentions Please do not excessive bending the product, this product have built-in sensor, excessive bending may damage the sensor;
Please do not contact the high-temperature service, and do not use it with some equipment like the electric blanket;
Please do not put the product in the water, it may cause damage to the interior of the product;
The monitor belt is suitable for a flat and stable surface. Do not put the monitor belt on an active bed ( such as a hammock ). Please make sure that no vibration source is near to ensure that the monitor belt can accurately detect the users sleep situation. The vibration of the electric fan, the washing machine, the loud music and so on may lead to the misjudgment of this product. 7 9. Product Usage Foreknowledge the cardiovascular function is usual or not, based on deep sleep data. The sleep stage, the quality of sleep, the sleep information, the average heart rate, and the average number of breathing. Real time heart rate, real time breathing number. 10. Matters Need Attention With Transportation This product can be packed with the requirements of the user. Prevent insolation, loading and unload carful, prevent violent impact. 11. Software Operation Information 8 health evaluation calendar set button WeChat sharing date sleep score average heart rate average breathing real-time status cardiovascular monitoring interface sleep monitoring interface set interface real-time status interface 9 12. Noise Information 10dbs Maximum noise 10dbs 13. Product Fault Treatment If the product fault, please contact with customer service. 010-82825528 service number: 010-82825528 14. Product Scrapping Treatment In accordance with the provisions of the general electronic product discarding. 15. Maintenance There is no special maintenance requirements for this product. Do not disassemble it without authorization. 10 16. Manufacturer Beijing Boshi Linkage Technology Co., Ltd.
2A-2229~2230 Room 2229-2230, No. 2# Building, Zhongguancun Software Park Incubator, Dongbeiwang Road, Haidian District, Beijing City, China Tel: 010-82825528 Importer: N/A Statement:
CE:
Hereby, Beijing Boshi Linkage Technology Co., Ltd., declares that this Elite Care is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. The full test of the EU declaration of conformity is available at the following internet address: http://www.boshilinkage.com FCC:
Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. 11 ISED:
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. 12