ECX332 Multimodal Face Recognition All-in-one Terminal Quick Start Guide v1.0 Dear users:
Thank you for purchasing ECX332 multimodal face recognition terminal!
We believe that youve made a wise choice and will enjoy wonderful changes and joyful daily life together with global users who trust ECX332 multimodal face recognition terminal. Every ECX332 multimodal face recognition terminal is produced with diligent efforts of Eyecool. Every component is the achievement of wisdom of numerous engineers. Our sophisticated skills and expertise been demonstrated in our excellent world-class products. With our unremitting efforts, we contribute to opening a wonderful and infinite life experience for all ECX332 users. We always strive to provide you with intimate and comfortable experience in all-round way, from products to services. Disclaimers Weve tried our best to ensure the correctness and reliability of information provided in this manual, but it may have deviation before and during printing. We may upgrade the product from time to time in order to improve the performance, reliability and installation of the components and systems. This may be inconsistent with the description in the manual, but it will not affect the actual operation. Please understand!
The functions specified in this manual shall not serve as a reason for applying this product for special any purposes. responsibility for the accidents and hazards caused by the misoperation of the user. not bear company shall The 1. Getting Started 1.1 Registration Instruction face recognition terminal, When using multimodal please follow the steps below for operation involving registration or identification:
(1) Stand in front of the multimodal face recognition terminal, and look at the screen of the terminal;
(2) Make sure the eyes are within the preview box at the top of the screen. If the eyes are out of the preview box at the top of the screen, it will adjust to align. 1.2 Startup the supporting power adapter at the Connect interface, and the system will start automatically within 25 sec. 2. Product Use 2.1 Device Activation - Registration Step 1 Select language:
Chinese and English (as shown in Fig.1) Step 2 Network selection and setting
(as shown in Fig. 2) Language Select network Skip English Wired network WIFI Domain name setting Network certificate setting Fig. 1 Fig. 2 Users Manual for ECX332 Multimodal Face Recognition All-
in-one Terminal Local: the data can be saved locally without need to connect to network. Click Skip in the upper right corner of the page (as shown in Fig. 2) to enter the local version. Network: the data can be interacted by connecting to the network. The network can be connected via wire or WiFi (as shown in Fig. 2). Wired network: insert the cable, connect the wired network, the data can be saved locally while being uploaded and downloaded via network. WIFI: connect WIFI, the data can be saved locally while being uploaded and downloaded via network. Note: the activation of local version is simpler than that of network version. You can register and activate by skipping steps relevant to network version. It can be regarded as the the local version is registered flight mode. After successfully, you can switch to the network version by enabling WIFI or Ethernet setting in the basic setting to connect to the network. It is recommended to apply the network version. The registration and activation of the two versions are shown as follows. Local Date and time Automatically confirm time and date Set date Set time 24-hour clock applied Fig. 3 Set door opening password and administrator password Please enter a new password Please confirm password Confirm Fig. 4 Users Manual for ECX332 Multimodal Face Recognition All-
in-one Terminal Fig. 5 Step 1: Click "Skip" to enter the local version and select the date and time. (As shown in Fig. 3) Step 2: Set the door opening password and administrator password: enter and confirm the new password, and click "Confirm". (As shown in Fig. 4) Step 3: Enter standby screen. (As shown in Fig. 5) Network Ethernet WLAN Ethernet Connection status Not connected Configure Ethernet Eyecool Chinanet-6 Eyecool-sc Fig. 6 Fig. 7 Users Manual for ECX332 Multimodal Face Recognition All-
in-one Terminal Set door opening password and administrator password Please enter a new password Please confirm password Confirm Fig. 8 Fig. 9 Step 1: Select wired network, open Ethernet, insert the network cable, and connect the wired network (as shown in Fig. 6); or select WiFi and enter correct WiFi password to connect (as shown in Fig. 7). Step 2: Set the door opening password and administrator password: enter and confirm the new password, and click "Confirm". (As shown in Fig. 8) After the password is set successfully, it jumps to the standby screen (as shown in Fig. 9). 2.2 Add Users Setting User setting Basic setting Logging Password management Comparison mode setting Parameter setting Restore factory setting About Fig. 10 Fig. 11 Users Manual for ECX332 Multimodal Face Recognition All-
in-one Terminal Administrator Enter name Enter phone number M1 card No. Next step Fig. 12 0%
Fig. 13
(1) Enter the setting interface:
Swipe the screen upward in the main identification interface, and the screen shows the input button of and the setting entry opening by password
(as shown in Fig.10). Click the setting button button on the right to enter the password input interface, enter the administrator password and click
"Confirm" to enter the setting (as shown in Fig. 11)
(the administrator can also enter the setting with iris recognition).
(2) Click "User setting" and then "Add user" to select
"Register as administrator" and "general user": take the registration as administrator as an example (as shown in Fig.12) to fill in the name and mobile phone number respectively. If you have M1 card, swipe M1 card and click "Next".
(3) Enter registration interface (as shown in Fig.13) and ensure the eyes within the preview box at the top of the screen at an distance about 55mm. After 100%
of the successful extraction of iris feature will pop at the bottom of the screen, indicating that the registration is successful. the registration progress completed, is 3. Door Opening Mode 3.1 Door Opening by Identification Get close to the multimodal face recognition terminal at the front. The iris identification main interface pops up when the person is sensed, ensure the eyes within Users Manual for ECX332 Multimodal Face Recognition All-
in-one Terminal the identification box at an distance about 55mm. The door opens when the legal face and iris are captured and identified. 3.2 Door Opening by Password Get close to multimodal face recognition terminal, swipe the screen upward in the main identification interface, and the screen shows the password input button and
. Click the setting entry button password input button on the left, enter the door opening password in the pop-up box and click
"Confirm" to open the door. 4. Detailed Introduction of Management Setting Function 4.1 User Setting After entering setting menu, the administrator can set the relevant user functions of the multimodal face recognition terminal. User information Name Xiaobo Mobile 15898933333 Authority management General users M1 card No. Swipe card Iris feature Face feature Fig. 14 to modify their Click registered users
"Name" and
"Management Authority", click "Iris Feature" and "Face to upload features. Click Feature" to prompt whether
"Confirm" to enter the registration interface to update features, and click "Delete" button below to delete users. (As shown in Fig. 14) Users Manual for ECX332 Multimodal Face Recognition All-
in-one Terminal 4.2 Basic Setting Basic setting Language Language setting Time setting Wi setting Ethernet setting English Fig. 15 Date and time Automatically confirm time and date Set date Set time 24-hour clock applied Fig. 16 WLAN Eyecool Chinanet-6 Eyecool-sc Fig. 17 Fig. 18 Ethernet Ethernet Connection status Not connected Configure Ethernet Fig. 19 You can change and set the language (Fig. 16), time and date (as shown in Fig. 17) and, wifi (as shown in Users Manual for ECX332 Multimodal Face Recognition All-
in-one Terminal Fig. 18), Ethernet (as shown in Fig. 19) in basic setting
(as shown in Fig. 15). 4.3 Logging Logging Identification log Operation log Warning log Fig. 20 You can view the identification log, operation log and warning log in logging. The log includes identification door opening record, password\entry record and identification failure record. Warning records, etc., containing specific date and time and real-time images. (As shown in Fig. 20) 4.4 Password Management Password setting Door opening password Administrator password Fig. 21 Enter the password management to modify the door Users Manual for ECX332 Multimodal Face Recognition All-
in-one Terminal opening password and administrator password. (As shown in Fig. 21) 4.5 Comparison Mode Setting Comparison mode setting Confirm Device comparison mode Local comparison Network comparison Local + network comparison Feature comparison mode Iris comparison Face comparison Iris + face comparison Iris or face comparison Multimodal Fig. 22 You can change the device and feature comparison modes in the comparison mode setting. The device comparison mode includes: local comparison, network comparison, local + network comparison. The feature face comparison mode includes:
comparison, face iris + face comparison, comparison, multimodal comparison. The comparison mode above can be changed according to user requirements. (As shown in Fig. 22) Iris comparison, iris or Users Manual for ECX332 Multimodal Face Recognition All-
in-one Terminal 4.6 Parameter Setting Parameter setting Confirm User synchronization Rotation calibration Opening time Light brightness 3s 500 Anti-disassembly warning switch Card swiping switch Iris reality switch Domain name setting Network certificate setting Fig. 23 light brightness, Enter parameter setting to set and manage user synchronization, rotation calibration, door opening time, anti-disassembly warning switch, card swiping switch, iris display switch, domain name and network certificate. User synchronization could force the user information in the download server to synchronize with the local when the network status is poor; Rotation calibration can be used to calibrate two cameras; Door opening time is the delay time after opening the door; The brightness of light is to enhance and weaken light compensation by plus and minus signs; The anti-disassembly warning switch gives an audible alarm when the multimodal face recognition terminal is illegally dismantled to remind the user. (As shown in Fig. 23) 4.7 Restore Factory Setting Users Manual for ECX332 Multimodal Face Recognition All-
in-one Terminal Restore factory setting?
Cancel Confirm Fig. 24 Click to restore factory setting, and a prompt will pop up to confirm whether to restore factory settings. Click "Confirm", and the system will restore to the factory setting. (As shown in Fig. 24) 4.8 About About SN 328153440a4e4a354837 48272a02 Iris version Face version v8.8.8.18 1.1.7.2 Face detection version v7.5.9.4 Access control version 1.0.2.40 Fig. 25 Enter About to view SN, iris version, face version, face detection version, access control version and other information of the device. (As shown in Fig. 25) 5. Warranty Card Warranty Card thank you for purchasing Eyecool Dear customer, products. In order to offer you with better service, please carefully read, fill in and properly keep this warranty card after purchasing. Customer name Customer address Product name Date of purchase Contact Tel Model Ex-factory No. Maintenance records Warranty description 1. Please keep this warranty card properly as maintenance voucher. 2. The warranty period of product is one year from the date of purchase. 3. With the normal use and maintenance during the warranty period, if there is any problem or fault in the material and process, our company will provide maintenance and replacement parts free of charge after investigation. 4. The company has the right to refuse service or charge materials and service fees as appropriate during the warranty period when:
(1) It is unable to provide this warranty card and valid purchase certificate.
(2) Product failure and damage is caused by improper use by users.
(3) The damage is caused by artificial abnormal external force.
(4) The damage is caused by disassembly and repair by maintenance technician not authorized by our company.
(5) Others damage is caused intentionally. 5. We reserve the right to modify and interpret all the contents. Federal Communications Commission (FCC) Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications made to this device not expressly approved by Beijing Eyecool Technology Co., Ltd. may void the FCC authorization to operate this device. Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the users authority to operate the equipment. RF exposure statement:
The transmitter must not be colocated or operated in conjunction with any other antenna or transmitter. This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a Minimum distance of 20cm between the radiator and any part of your body. Tel: 010-59713131 Fax: 010-59713031 Email: 6s@eyecool.cn Address: 8F, Building 1, Brilliant International, Shangdi 10th Street, Haidian District, Beijing www.eyecool.cn