all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 1.59 MiB | November 11 2009 | |||
1 | Cover Letter(s) | November 11 2009 | ||||||
1 | External Photos | November 11 2009 | ||||||
1 | Internal Photos | November 11 2009 | ||||||
1 | ID Label/Location Info | November 11 2009 | ||||||
1 | Test Report | November 11 2009 | ||||||
1 | Test Setup Photos | November 11 2009 |
1 | User Manual | Users Manual | 1.59 MiB | November 11 2009 |
VERAS 9 VERAS 7 VERAS 5 Nano BTE Behind-the-ear hearing instruments INSTRUCTIONS FOR USE TABLE OF CONTENTS Introduction Description of features Inserting instruments with an earmold Removing earmold and hearing instruments Inserting instruments with a Spira Flex sound tube Removing your instruments and Spira Flex sound tube Operating your instruments (ON/OFF) Changing the volume level Changing programs Changing the battery Data logging and learing 7 8 10 12 13 14 15 16 17 18 20 Operating the instruments with remote control 21 Operating the instruments with SoundGate 22 3 3 44 Instrument care Using your hearing instruments Using the telephone Environmental protection Product approval, markings and compliance Compliance with radio communications requirements for the USA and Canada Compliance with requirements for Europe Cell phone and hearing instrument compatibility International warranty Your hearing instrument configuration Accessories General warnings and safety guidelines Common problems and solutions Service Notes 23 30 33 34 35 37 40 42 44 45 46 47 52 56 57 5 5 Congratulations on the purchase of your new Bernafon hearing instruments. With a little practice, you will soon be on your way to better hearing. Please read the entire contents of this booklet before using your hearing instruments. It contains instructions and important information about the use and handling of your hearing instruments and batteries. 6 Introduction Bernafon nano BTE IFU The following instruments are covered in these instructions:
Veras Nano BTE VR_ILU_nanoBTEwithSpira_BW_HI VR9 N VR7 N VR5 N Note: The instruments are available either with earhook or Spira Flex sound tube. 7 Bernafon nano BTE IFU Description of features VR_ILU_nanoBTEwithSpira_BW_HI 2 2a 1 8 3 4 5 6 7 1 Push button 2 Microphone 2a Second microphone 3 Adapter 4 Spira Flex sound tube Bernafon nano BTE IFU 5 Sound outlet 6 Dome 7 Concha clip 8 Battery drawer VR_ILU_Left-rightEarMarkingNanoBTE_BW_HI Left/Right ear marking A color marking inside the battery drawer can help you distinguish the left and right instruments. Red = right; Blue = left 8 Bernafon nano BTE IFU Description of features VR_ILU_nanoBTEwithHook_BW_HI 3 4 2 2a 1 5 1 Push button 2 Microphone 2a Second microphone 3 Earhook 4 Sound outlet 5 Battery drawer Earmold (used with earhook) 2 3 4 1 5 1 Canal 2 Sound outlet 3 Tubing 4 Helix 5 Vent 9 Inserting instruments with an earmold Bernafon nano BTE IFU It takes patience and practice to insert your earmold correctly. If you have difficulty, please consult your hearing care professional. VR_ILU_InsertingNanoBTEhook1_BW_HI Hold the earmold by the tubing so that the helix part is pointing straight up and the canal part is pointing at the ear canal entrance. Insert the canal part into your ear canal, twisting slightly to ease the helix portion into place. It may help to pull the ear lobe down with the other hand, or pull the top of the ear back and up. 10 VR_ILU_InsertingNanoBTEhook2_BW_HI Run your index finger down the skin just in front of your ear. If you can touch the helix part of the earmold, it is not inserted correctly. Gently push it behind the fold of your ear. Lift the hearing instrument into place behind your ear. Be careful not to twist the tubing. 11 Removing earmold and hearing instruments Lift the instrument from your ear first. Push the back of your ear with your thumb to loosen the helix part of the earmold, then use your index finger to remove it. Grasp the helix part of the earmold and twist it forward. Gently pull the earmold straight out of the ear, holding on to the helix part of the mold. Important: Do not remove the earmold by pulling on the hearing instrument. This could disconnect the instrument from the earmold or damage the tubing. 12 Inserting instruments with a Spira Flex sound tube Bernafon nano BTE IFU Practice inserting your sound tube correctly. VR_ILU_InsertingNanoBTEspira1_BW_HI First, position the hearing instrument behind your ear. Grasp the bend of the sound tube and gently push the dome into your ear canal until the tube rests against the side of your head. Push the ear grip into the bowl of your ear. If the sound tube is stick-
ing out from your ear, insert the dome further. If the ear grip is sticking out, it has not been positioned correctly. Bernafon nano BTE IFU VR_ILU_InsertingNanoBTEspira2_BW_HI Bernafon nano BTE IFU VR_ILU_InsertingNanoBTEspira3_BW_HI 13 Removing your instruments and Spira Flex sound tube Grasp the bend of the sound tube and gently pull the tube and dome out of your ear. Lift the instrument from behind your ear. Important: Do not remove the sound tube and dome by pulling on the hearing instrument. This might disconnect the instrument from the sound tube. 14 Operating your instruments (ON/OFF) VR_ILU_OnOffFunctionNanoBTE_BW_HI Click ON Click OFF To turn the instrument ON Close the battery door completely. The hearing in-
strument will emit one long beep when it starts up. To turn the instrument OFF Open the battery door slightly until a click is felt. Important: Never force the battery drawer open or closed. 15 Changing the volume level The instrument automatically adjusts the volume to the changing sound environment. If you desire to manipulate the volume yourself, you may use the optional RC-P remote control or the SoundGate communication device for this purpose. Please follow the detailed directions in the Instructions for Use included with these devices. Note: Your instruments automatically return to a preset loudness level when the instrument starts, the battery is low, or when the program is changed. If you find that you frequently need to turn the volume up or down, your hearing care professional may need to adjust your settings. 16 Changing programs Your hearing instrument can be configured with 3 to 4 listening programs. Please see page 45 to find out which programs have been configured for your hearing instruments. You can change programs as follows:
Push button A press on the button will cause the program to change. This will take some seconds until you hear the program change. The number of beeps you hear will tell you which program you are in. RC-P or SoundGate The program can be changed with either of these devices. Please see pages 21 and 22 for instructions. 17 Changing the battery Bernafon nano BTE IFU When the battery is about to run out, the instrument will beep at regular intervals. The battery should be replaced immediately. VR_ILU_BatteryReplacementNanoOut_BW_HI Gently swing the battery drawer fully open, but do not force it. Bernafon nano BTE IFU VR_ILU_BatteryReplacementNanoIn_BW_HI Take out the used battery. Remove the sticker from the new battery. Place the battery into the drawer with the flat, smooth side facing up
(+ sign). Close the battery drawer securely. 18 Important battery information Battery life will vary with conditions of use
(batteries will run down faster in noisy environ-
ments). Always keep spare batteries on hand. A used battery should be replaced immediately. If you are not going to use your hearing instru-
ments for a few days, remove the batteries. Any moisture found on a battery should be wiped off immediately with a soft cloth. Used batteries should be returned to your battery supplier or hearing professional for safe disposal. Never dispose of batteries by burning them. They may explode and cause injury. Never dispose of batteries with household waste. They cause environmental pollution. Note: Always remove zinc-air batteries before drying your hearing instrument with a drying kit. Drying out zinc-air batteries shortens their lifetime. 19 Data logging and learning Data logging The data log automatically stores information about your use of the hearing instruments such as changes made to the volume control, hours of wear, etc. This information can be used by your hearing care professional to adjust your instru-
ments. If you do not want this feature to be active, please ask your hearing care professional to turn it off. Data learning (VR9 and VR7 Nano BTEs only) If your instrument is equipped with data learning, your hearing professional can activate this feature to help customize your hearing instru-
ments. When Data Learning is operating, the instrument keeps track of how often and how much you adjust the volume control and learns your preferred setting. This new setting can be made permanent during your follow-up visit. 20 Operating the hearing instruments with the optional RC-P remote control If you have purchased a remote control you can use it to change programs, adjust the volume level up and down, or mute the instruments. For complete operating instructions, please read the separate RC-P remote control instructions for use booklet. 1 2 3 4 1 Program cycle button 2 Volume control 3 Mute button 4 Status light 21 Operating the instrument with the optional SoundGate communication device (VR9 and VR7 Nano BTEs only) If you have purchased a SoundGate you may use it to perform basic functions such as program changes and volume adjustments. In addition, the SoundGate serves as a link between your hearing instruments and external sources such as music players, cell phones, computers, etc. For complete operating instructions, please read the separate SoundGate instructions for use booklet. SoundGate (optional) 1 Volume control and program change 2 Phone 3 Music connection e.g. MP3 4 Bluetooth music/audio 5 Battery indicator 1 2 3 4 5 22 Instrument care Healthy ears produce a waxy substance that can clog your hearing instruments. Please follow these cleaning instructions to prevent wax build-up and ensure optimal performance of your instruments. Every night Check your instruments for ear wax and wipe them clean with a cloth or tissue. If necessary, use the cleaning tool to remove wax from the canal and vent openings on your earmold. Open the battery drawer fully to allow air to circulate. A dry storage kit is recommended to remove any moisture that may have accumulated in the instrument. 23 If you have an earmold You should wash your earmolds regularly. The hearing instrument itself must never be washed or allowed to get wet!
Handle your instruments over a soft surface Bernafon nano BTE IFU to avoid damage in case you drop them. VR_ILU_CleaningEarmoldAttachNano_BW_HI Disconnect the earmold from the hearing instrument by grasping the end of the hook firmly with one hand and grasping the tub-
ing firmly with the other hand. Pull the tubing away from the earhook. Gently clean the earmold in warm soapy water. Rinse the earmold and allow it to dry completely. 24 Use an air puffer to remove any remaining moisture in the tubing. When re-attaching the earmold to the instrument, it is important to position it correctly, as shown above. 25 Cleaning the Spira Flex thin sound tube system If you have the sound tube system, make sure that the tube and dome are kept free of ear wax at all times. Grasp the adapter firmly and disconnect the sound tube from the instrument by pulling it off. Use a soft dry cloth or tis-
sue to clean the outside of the sound tube and dome. To remove wax from the sound tube, insert the cleaning floss at the connector end. Push the floss all the way into the sound tube until it comes out through the dome. Pull the floss out through the dome and discard it. Reattach the sound tube connector to the adapter. Important: To avoid blocking the sound tube, do not use water to clean it. 26 Exchanging the dome The dome should be changed regularly. The fre-
quency of dome changes will depend on how fast ear wax builds up on the dome. Spare domes can be obtained from your hearing care professional. Remove the old dome by pulling it off the end of the sound tube. With clean fingers, push a new dome as far as possible onto the sound tube. When attached correctly, the dome should touch the plastic ring around the sound tube. Warning If the dome is not securely attached to the sound tube, it could fall off in your ear canal. If this happens, please see your medical practitioner. 27 Exchanging the Spira Flex sound tube If the sound tube becomes discolored, stiff or brittle, it should be replaced. Hold the instrument by the adapter and grasp the tube close to the connector. Pull firmly to remove the old tube. Attach the new sound tube by pushing it firmly into the connector. Bernafon nano BTE IFU VR_ILU_ExchangingSpiraNanoBTE_BW_HI 28 Avoid heat, humidity and chemicals Do not expose hearing instruments to extreme heat by leaving them in the car, near a radiator, etc. Avoid exposing your instruments to moisture ie steambaths, showers, heavy rain, etc. Never attempt to dry your instruments with a hair dryer, microwave oven, etc. Remove your instruments before applying aftershave, hairspray, oils, perfume, mosquito repellent, lotions, etc. Allow the product to dry before wearing your instruments. Protect your instruments by keeping them in the case when you are not wearing them. 29 Using your hearing instruments Hearing instruments do not restore perfect hear-
ing. They make sounds louder and help you make the most of the hearing you have. While some immediate benefit is usually noticed, it often takes several weeks for your brain to adapt to the new sounds. The following tips will help you learn to use your instruments. If you have trouble adjusting, consult your hearing care professional. Getting started Wear your instruments at home in a quiet environment. Have a conversation with one person or listen to a news program on TV. You will benefit most if you wear your instru-
ments all day long. Increase the time each day until you are comfortable wearing them for several hours at a time. 30 You may notice that your own voice sounds louder. If the voices of others are at a comfort-
able level, try speaking at a lower volume. Sounds like footsteps, chirping birds, rustling paper, etc. may seem quite loud at first because you probably havent heard them for awhile. They will soon fade to the background. Dining out Start with a quiet restaurant (no music or enter-
tainment). Request a table away from the kitchen and other noisy areas. Conversation will be easier in a smaller group. In the car Sit with your better ear toward the center of the car. Turn off the radio. Keep windows closed to minimize traffic, road and wind noise. 31 Attending theatre, concerts, lectures, etc. Try to sit with your better ear closer to the sound source. Become familiar with the program in advance to make it easier to follow. At work Inform your co-workers about your hearing loss. If you hear only part of a conversation, repeat what you have heard and ask for the missing information. 32 Using the telephone Hold the receiver close to the microphone inlet of your hearing instrument. If this causes whistling, move the receiver away a small distance. Before purchasing a mobile phone, test it with your hearing instrument. People with a greater degree of hearing loss may need a volume control on the telephone. 33 Environmental protection Your hearing instruments contain electronic components subject to the Directive 2002/96/EC on waste electrical and electronic equipment. Help to protect the environment by not disposing of your hearing instruments or batteries with your unsorted household waste. Please recycle your hearing instruments and batteries according to your local regulations or return them to your hear-
ing care professional for disposal. 34 Product approval, markings and compliance All Bernafon Veras hearing instrument models comply with international standards concerning electromagnetic compatibility. Due to the limited size available on the instruments all relevant approval markings are found in this document. Electromagnetic interference Your hearing instrument has been thoroughly tested for electromagnetic interference. However, some products may emit electromagnetic energy causing unforeseen interference with hearing instruments. Examples include induction cooking appliances, shop alarm systems, mobile phones, fax machines, personal computers, X-rays, CT scans, etc. Even though your hearing instruments are designed to comply with the most stringent international standards of electromagnetic compatibility, they may emit electromagnetic energy that can cause interference with other devices. 35 Your hearing instruments may contain a radio transmitter using short range magnetic induction technology working at 3.84 MHz. The magnetic field strength of the transmitter is < 42 dBA/m @ 10 m. The electromagnetic emission from the radio system is well below international limits for human exposure. By comparison, the electromagnetic energy of the hearing instrument is lower than that generated by household items such as halogen lamps, computer monitors, dishwashers etc. 36 Compliance with radio communi-
cations requirements for the USA and Canada Bernafon AG Veras hearing instrument models VR9 N; VR7 N;
VR5 N FCC ID IC:
U6XFUBTE01 7031A-FUBTE01 Statement of compliance:
This device complies with part 15 of the FCC Rules and RSS-210 of Industry Canada. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. 37 These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communica-
tions. However, there is no guarantee that inter-
ference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be de-
termined by turning the equipment off and on, the user is encouraged to try to correct the inter-
ference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experience radio/TV technician for help. 38 Caution: Changes or modifications not expressly approved by Bernafon AG could void the users authority to operate the equipment. 39 Compliance with requirements for Europe This device is in conformance with the require-
ments of the Directive 93/42/EEC of the Council of the European Communities concerning medical devices, MDD. This is certified by applying the following marking:
This device also complies with the essential requirements of the Directive 1999/5/EC of the European Parliament on radio equipment and telecommunications terminal equipment, R&TTE. It operates as an inductive application in a harmonized frequency band according to the Commission Decision 2008/432/EC and may be used in all member states of the EU and EFTA. This is certified by applying the following marking:
40 Declaration of conformity is available at:
Bernafon AG Morgenstrasse 131 3018 Bern Switzerland 41 Cell phone and hearing instrument compatibility Some hearing instrument users have reported a buzzing sound in their instruments when they are using cell phones, indicating that the cell phone and hearing instrument may not be compatible. The compatibility of a particular hearing aid and cell phone can be predicted by adding the rating for the hearing aid immunity to the rating for the cell phone emissions (ANSI C63.19-2006 American National Standard Methods of Measurement of Compatibility between Wireless Communication Devices and Hearing Aids). For example, the sum of a hearing aid with a rating of 2 (M2/T2) and a telephone with a rating of 3 (M3/T3) would result in a combined rating of 5. According to the standard, any combined rating that equals at least 5 would provide normal use;
a combined rating of 6 or greater would indicate excellent performance. 42 The immunity of your Veras hearing instrument is at least M2/T2. The equipment performance measurements, categories and system classifica-
tions are based upon the best information available but Bernafon cannot guarantee that all users will be satisfied. 43 International warranty Your hearing instruments have a limited warranty, covering defects in materials and workmanship. This warranty covers the hearing instruments themselves, but not accessories such as batteries, tubing, earmolds, etc. This warranty is void if a defect is the result of misuse or mistreatment. The warranty is also void if the hearing instruments have been repaired by nonauthorized service personnel. Please review the warranty with your hearing care professional and make sure that your warranty card is completed correctly. 44 Your hearing instrument configuration Available programs Your hearing instruments are programmed in the following way:
Function Program 1 2 3 4 Beeps 1 2 3 4 Right and left instruments synchronized When this feature is active, changes made to one instrument are automatically made in the other through a wireless communication link. M Active M Inactive 45 Accessories Bernafon offers a wide range of optional acces-
sories that may be purchased to enhance your hearing system. Depending on hearing instrument type and local regulations, the following accesso-
ries are available:
Remote control SoundGate communication device (for wireless connection to cell phones, music players, etc.) TV adapter (for wireless connection to your television via the SoundGate) Phone adapter (for wireless connection to your landline phone via the SoundGate) Cleaning and drying kit For further information on accessories please contact your hearing care professional. 46 General warnings and safety guidelines Hearing instruments and batteries can be danger-
ous if swallowed or improperly used. Such actions can result in severe injury, permanent hearing loss or even fatality. Familiarize yourself completely with the following general warnings before using your hearing instru-
ments. Hearing instruments should be used only as directed and adjusted by your trained hearing care professional. Misuse or improper adjust-
ments can result in sudden and permanent hearing loss. Hearing aids will not restore normal hearing or prevent hearing loss resulting from organic conditions. Never allow others to wear your hearing instru-
ments, because they are adjusted for your hear-
ing requirements and may permanently damage another persons hearing. 47 A slap to your ear while wearing the instrument could be harmful. Avoid wearing your hearing instrument while playing contact sports (e.g. rugby, football etc.). Be aware that use of a hearing instrument may cause excess earwax to build up in the ear canal which may require removal by a trained medical professional. In rare cases, a hearing aid or earmold may cause a discharge from the ear or allergic reaction. See a physician immediately if these conditions occur. An earmold is a custom-made product. If you experience discomfort or irritation of your ear, please see your hearing care professional imme-
diately for modification of the earmold. Hearing instruments, their parts and batteries should be kept out of reach of infants, children and anyone who might swallow these items or otherwise cause themselves injury. Discard batteries and keep them out of sight of infants, small children, persons of mental incapacity or pets. 48 Clean your hearing instruments and their parts on a regular basis as recommended. Micro-
organ isms from unclean instruments may cause skin irritations. Be careful with leaking battery liquid, as it is a hazardous substance. Never try to recharge non-rechargeable batteries. Never change the battery or adjust the controls of the hearing instrument in front of infants, small children and persons of mental incapacity. Never put your hearing instrument or batteries in your mouth, they could easily be swallowed. Keep batteries away from medications. Batteries are easily mistaken for pills. In case a battery or hearing instrument is swallowed, see a doctor immediately. Be aware of the possibility that your instruments may stop functioning without notice. Keep this in mind while you circulate in traffic or otherwise depend on warning sounds. 49 Traffic or other warning sounds may also be reduced in level by a directional microphone when these sounds are coming from behind you. Never insert cleaning tools into the sound outlet or microphone inlet. This could damage the hearing instruments. 50 Notes 51 Common problems and solutions Possible cause Instrument not inserted correctly Ear wax accumulation in ear canal Earmold may be too loose Tubing may be split or improperly connected Instrument may not be turned ON Battery may be dead or inserted wrong way Volume level too soft Ear wax accumulation in ear canal Battery contacts may be dirty or corroded Instrument sound outlet may be blocked Microphone sound inlet may be blocked Your hearing loss may have increased Problem Instrument whistles or squeals No volume, level too soft or humming noise 52 Solution Re-insert instrument Consult your hearing care professional or physician Consult your hearing care professional Consult your hearing care professional Check that the battery drawer is closed completely Insert a fresh battery Increase volume level with control on instrument or remote control Consult your hearing care professional or physician Open and close the battery drawer several times or clean the battery contacts carefully with a dry Q-tip Check the tubing and the earmold or dome Consult your hearing care professional, do not try to clean this yourself Consult your hearing care professional 53 Problem Whirring noise, fading, weak or motor-boating sounds Possible cause Battery contacts may be dirty or corroded Moisture in hearing instrument Low battery Low battery Instrument switches from ON to OFF periodically 54 Solution Open and close the battery drawer several times or clean the battery contacts carefully with a dry Q-tip Place instrument in Dry-Aid pack. Remove battery first. Consult your hearing care professional. Insert a fresh battery Insert a fresh battery 55 Service If none of the actions, listed on the previous pages, solve the problem, contact your hearing care professional. Do not attempt to repair your hearing instruments yourself. Place stamp with dispenser name and address here:
56 Notes 57 Notes 58 Australia Bernafon Australia Pty. Ltd. 12/97 Castlemaine Street Milton QLD 4064 Freecall 1800 809 111 Phone +61 7 3250 0300 Fax +61 7 3250 0372 www.bernafon.com.au Canada Bernafon Canada Ltd. 500 Trillium Drive, Unit 15 Kitchener, Ontario Canada N2R 1A7 Phone +1 519 748 6669 Toll Free +1 800 265 8250 Toll Free Fax +1 888 748 9158 www.bernafon.ca Manufacturer Switzerland Bernafon AG Morgenstrasse 131 3018 Bern Phone +41 31 998 15 15 Fax +41 31 998 15 90 www.bernafon.com New Zealand Bernafon New Zealand Ltd. Level 1, Building F 27-29 William Pickering Drive Albany, Auckland 0632 Free Call 0800 442 257 Phone +64 9 920 42 40 Fax +64 9 920 42 43 www.bernafon.co.nz United Kingdom Bernafon UK Cadzow Industrial Estate Off Low Waters Road Hamilton ML3 7QE Scotland Phone +44 1698 285 968 Fax +44 1698 421 456 www.bernafon.co.uk United States of America Bernafon, LLC 200 Cottontail Lane, Bldg. B Somerset, NJ 08873 Phone +1 888-941-4203 Fax +1 732-560-4877 www.bernafon-us.com www.hear-it.org For more information about hearing and hearing loss e g n a h c o t t c e b u s
j 0 0
0 1 3
0 8
6 5 9
G A B
9 0 7. 0
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2009-11-11 | 3.84 ~ 3.84 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2009-11-11
|
||||
1 | Applicant's complete, legal business name |
Bernafon AG
|
||||
1 | FCC Registration Number (FRN) |
0016279770
|
||||
1 | Physical Address |
Morgenstrasse 131
|
||||
1 |
Bern, N/A 3018
|
|||||
1 |
Switzerland
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
j******@ict.cetecom.de
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
U6X
|
||||
1 | Equipment Product Code |
FUBTE01
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
K******** F********
|
||||
1 | Title |
Team leader Quality Assuranceand Regulatory Affair
|
||||
1 | Telephone Number |
+41-3******** Extension:
|
||||
1 | Fax Number |
+41-3********
|
||||
1 |
k******@bernafon.ch
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Hearing Aid | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
CTC advanced GmbH (former CETECOM ICT Services )
|
||||
1 | Name |
G******** S****
|
||||
1 | Telephone Number |
49-68********
|
||||
1 | Fax Number |
49-68********
|
||||
1 |
t******@ctcadvanced.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 3.84000000 | 3.84000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC