SPECIFICATIONS 54299E Capacity:
2-4 Adults Water Capacity (80%):
177 gal. (669 L) Massaging Turbo Blower:
Heat Element:
Inflated Size:
Filled Weight:
71in. x 26in.
(1.80m x 66cm) 1,534 lbs. (696 kg) Pump:
Temperature Capacities:
6.5A Increased Heat Rate:
Power Rate:
Working Pressure:
11.3A at 68oF (20oC) 0.7A Circulation Filter Pump 104oF (40oC) Approximately 2-3oF/h (1-1.5oC/h) 110-120V AC, 12A at 68oF (20oC) 0.055Bar (0.8PSI) Actual Water Flow:
350 gal./h (1,325 L/h) NOTE: The above heating rate is based on a lab test conducted with an ambient temperature of 77oF (25oC) and above. Part N. 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 01 01 Part Code 6 P P0 P 40 54123GASS17 P6931ASS16 P04674 P03821 P6934ASS16 P6575ASS16 F4C009B-02ASS17 P00217 F6414ASS16
P61726ASS18 P61727ASS18 P00260
017 018 Description Pool liner Spa Heater Top Reinforce Cover Inflatable Cover Inflation Hose Filter Set Chemical Dispenser Water Hose Set Stoppers Screw Valve Cover Adapter A Buckle Filter Cartridge (VI) Deflation T-joint Deflation Valve Adapter Spa Debris Screen
012 QTY 1 1 1 1 1 2 1 1 3 1 1 6 2 1 1 1
5 GFCI Test IMPORTANT: RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED BEFORE TURNING ON THE PUMP EACH TIME. 1. Plug the GFCI into a power outlet, the indicator turns red. 2. Press the test button, the indicator turns off. 3. Press the reset button again, the indicator turns red and the spa is ready for use. WARNING: The GFCI plug must be tested before each use to avoid risk of electric shock. WARNING: Before inserting plug into a power outlet, make sure the current rate of the power outlet is suitable for the pump. WARNING: Do not use the pump if this test fails and contact our Aftersales Service.
NOTE: When inflating, you will notice that air will be expelled from the area where the air hose connects to the pump, this is normal for technique requirements. NOTE: Do not use an air compressor to inflate the pool. NOTE: Do not drag the pool on rough ground as this may cause damage to the pool liner. NOTE: Inflation time for reference only. It is recommended to find a professional electrician to connect the SPA pump to the grounding end of the house with a solid copper conductor of at least 6AWG (13.3mm2). 7 303021213400_14.0x21.0cm_54124,54130,54149,54155,54176,54187,54190,54295,54297_AirJet SPA_ Assembly 1. 1 s ec
. 3 seconds to unlock. 2. P6609ASS16 4. 2 3. s ec
. 1 5. rol nt o C s ec
. Inflate for 5 min. To stop inflation. 6. Inflate for 2 min. 7. 8. 9. 10. MAX. MIN. 7 Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 37C (98.6F). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include failure to perceive heat; failure to recognize the need to exit spa or hot tub; unawareness of impending hazard; fetal damage in pregnant women; physical inability to exit the spa or hot tub; and unconsciousness resulting in the danger of drowning. WARNING: THE USE OF ALCOHOL OR DRUGS CAN GREATLY INCREASE THE RISK OF FATAL HYPERTHERMIA IN HOT TUBS AND SPAS. Lock/Unlock Button The pump has a 5-minute auto-lock. The LED light will dim out when the pump is locked (no function is activated). To lock or unlock the pump, place a finger over the lock/unlock button for 3 seconds. Power-Saving Timer Button This is a newly added function, designed to help avoid wasting power by setting the time and duration of the heating cycle for the spa. This way, you can enjoy your spa at the time you desire, without needing to leave the heater on at all times. STEP 1: Set the heating duration 1. Press the button unit the LED starts to flash. 2. Press the or button to adjust the heating duration (From 1-48 hours). 3. Press the button again to confirm the heating duration. STEP 2: Set the number of hours FROM NOW when the heater will activate 1. After setting the heating duration, the LED starts to flash. 2. Press the or button to adjust the hours until time of activation
(From 0-99 hours). 3. Press button again or simply touch nothing for 10 seconds to confirm the setting. The LED will light steadily, and the countdown to heater activation will begin. To modify the timer settings: Press the button and use the or button to adjust. Cancel the setting: Press the button for 2 seconds. NOTE: After setting, the screen flashes the current temperature and time alternately. NOTE: Timer adjustment (amount of time with the heater ON) may be set from 1 to 48 hours; Reservation time adjustment (the number of hours FROM NOW when the heater will begin to function) may be set from 0 to 99 hours. If the timer is set at 0 hour, the heating system will activate immediately. Note that the timer is one time per use - the user sets the duration of the heating cycle, and how many hours from now the heating cycle begins. The timer does NOT repeat until reset. Massage System Button Use this button to activate the massage system, which has a 30-minute auto-shutoff feature. The light above the Massage System Button displays red when activated. IMPORTANT: Do not run the Massage system when the cover is attached. Air can accumulate inside the spa and cause irreparable damage and bodily harm. NOTE: Heat and massage system work together to create a warm massage experience. Celsius/Fahrenheit Toggle
The temperature can be displayed in either Fahrenheit or Celsius.
Heat Button Use this button to activate the heating system. When the light above the heat button is red, the heating system is activated. When the light is green, the water is at the set temperature and the heating system is at rest. NOTE: If the heating system is activated the filtration system will automatically start. NOTE: After turning off the heating system the filtration system will continue to operate. Water Filter Button This button turns the filter pump on and off. The light above the Water Filter Button displays red when activated. Temperature Adjustment Buttons Pressing the Temperature Increase or Decrease buttons will cause the LED to flash. When it is flashing you can adjust to the desired temperature setting. If you hold these buttons down the values will rapidly increase or decrease. The new and desired temperature setting will remain on the LED display for 3 seconds to confirm the new value. NOTE: The default temperature is 35C (95F). NOTE: Temperature adjustment ranges from 20C (68F) to 40C (104F). On/Off Button Press this button for 2 seconds to active the control panel bottons and the light turns to green. Press this button for 2 seconds to turn off all currently activated functions.
Power-Saving Timer LED This LED flashing means you are setting the heating duration. The light will be on when the heating function starts to work. This LED flashing means you are setting the number of hours FROM NOW when the heater will activate. When the light is on, the Power-Saving Timer function is set. LED Display Once powered-up the LED displays the current water temperature automatically. After 72 hours of filtration (without using the power saving timer function), the pump will hibernate and flash End with the current water temperature. When the pump is hibernating both the heating and water filter functions are disabled. To re-activate the pump press lock/unlock button for 3 seconds. NOTE: The water heat rate may change in the conditions below:
When the outdoor temperature is below 15C (59F). If the cover is not in position when the heating function is activated. NOTE: To display the current water temperature, run the filter system for at least a minute. The water temperature as tested by an external thermometer may vary from the temperature as displayed on the spa panel by as much as approximately 2C. 303021213400_14.0x21.0cm_54124,54130,54149,54155,54176,54187,54190,54295,54297_AirJet SPA_ 8 Alarms Causes Reasons Solutions The water flow sensors work without pressing the filter or heat button. After starting or during the functions of filtering or/and heating, the water flow sensors do not detect water flow. 1. The water flow sensor flags didnt fall back into the correct position. The water flow sensors are broken. 2. 1. Unplug the pump, strike the side of the pump firmly (but not violently), and plug it back in. To get assistance visit our website www.bestwaycorp.com support section. 2. 1. You forgot to remove the 3 stopper caps from inside the pool. Filter cartridges are dirty. 2. 3. Activate the filter or heat system and put your hand in front of the outlet pipe inside the pool to check if you can feel water flowing out. If no water flows out the water pump is broken. a. b. Water flows out but the alarm appears, than the water flow sensors are broken. 1. Remove the two stopper caps before starting the heating system. Refer 2. to the Assembly section in the Users Manual. Remove the filter set from inside the pool and push the filter or heat button. If no alarm appears, clean or change the filter cartridges and re-install the filter set inside the pool. 3. To get assistance visit our website www.bestwaycorp.com support section. 4. Filter housing issue blockage 4. Clean the filter housing and check for damage.Replace or re-
install as necessary. If not, please to get assistance visit our website www.bestwaycorp.com support section. 5. Kinked or bent pipes.Poor water flow through the plastic pipes of the liner 5. Please check throug the spa connection if you can see the pipes bending, to get assistance visit our website www.bestwaycorp.com support section. 6. Debris screens are blocked: debris screens can become blocked by the hard water are as due to calcium build-
up, the opening of the debris and stop the flow. those small debris block 6. Empty the spa and place a garden hose inside the pipes and wash the debris, to be sure all debris are removed perform the operation from outside and inside the spa. Use a toothbrush to remove any stubborn debris If the above steps, please to get assistance visit our website www.bestwaycorp.com support section. 7. Perished washers The washers within the spa couplings may have become perished or worn. 7. Check the washers inside the coupling for damage. Unscrew the couplings and remove the washer for further inspection. If not, please to get assistance visit our website www.bestwaycorp.com support section. The pumps thermometer reads the water temperature below 4C (40F). 1. The water temperature is lower than 4C (40F). 2. If the water temperature is higher than 7C (44.6F), the pumps thermometer is broken. The pumps thermometer reads the water temperature over 48C (119F). 1. 2. The water temperature is over 48C (119F). If the water temperature is lower than 45C
(113F), the pumps thermometer is broken. The pumps thermometer connections have issues. The thermal cut-out cut off. 1. The pumps thermometer connectors dont work properly. The pumps thermometer is broken. 2. 1. The ambient temperature is over 50C (122F) or the pump is directly under the sunshine. The thermal cut-out is broken. 2. 1. The spa is not designed to operate with water temperatures lower than 4C
(40F). Unplug the pump and only re-start the pump when the water temperature reaches 6C (43F). 2. To get assistance visit our website www.bestwaycorp.com support section. 1. The spa is not designed to operate with water temperatures greater than 40C (104F). Unplug the pump and only re-start the pump when the water temperature reaches 38C (100F) or lower. 2. To get assistance visit our website www.bestwaycorp.com support section. To get assistance visit our website www.bestwaycorp.com support section. 1. Unplug the pump, and put the pump in a dry, cool place. Only re-start the pump when the water temperature reaches 34C (93.2F) or lower. 2. To get assistance visit our website www.bestwaycorp.com support section.
ON/OFF
After the GFCI Test, press the "RESET" button , then press the pump button on the control panel for 3 seconds, then the indicator start to flash , pump has entered the matching condition. 2. Press the button for 3 seconds on remote control , the LED display on remote control will appear "PIR", remote controller has entered the matching condition. If LED display appear "PAS" , means finish connection. NOTE:1.When the remote control or pump into the matching condition, only 20 seconds matching time, matching will fail over time, You need to follow the steps above to match. 3. When the pump and the remote control matching conditions at the same time, the matching will be successful. 4. NOTE: The distauce of remote control is less the 10m. The remote controller matching is successful, First of all, you need to open the
button, Then you can start to use WARNING !
Do not put the Remote Control in the water, if the remote control falls into water, take it out of the water immediately. Damage to the remote control caused by immersion in the water is not covered under your warranty. The battery replacement Battery Precaution Do not mix old and new batteries. Do not mix the different types of batteries. Do not mix alkaline, standard (Carbon - Zinc), or rechargeable (Nickel - Cadmium) batteries. Ensure batteries are installed correctly with regard to polarity (+ and -). Do not short-circuit the battery. Never attempt to recharge primary batteries as this may cause leakage, fire, or explosion. Rechargeable batteries are to be removed from this product before being charged. Never attempt to disassemble or open batteries as this can lead to electrolyte burns. Remove batteries from equipment which is not to be used for an extended period of time. Exhausted batteries are to be removed from this product. Do not dispose of product and its batteries in fire. Check your local regulations for proper disposal instructions. Batteries shall not be exposed to excessive heat such as sunshine, fire or the similar. Keep batteries out of the reach of children. Only use 2x CR2032 batteries.