BlueSecure Access Point 1800 Installation Guide Bluesocket, Inc. 10 North Avenue Burlington, MA 01803 USA
+1 781-328-0888 www.bluesocket.com Part Number: 870-01500-M00 Document Version: 1.0 Copyright Notice Copyright 2006, 2007 Bluesocket, Inc. All rights reserved. No part of this document may be reproduced in any form or by any means, electronic or manual, including photocopying without the written permission of Bluesocket, Inc. The products described in this document may be protected by one or more U.S. patents, foreign patents, or pending patents. This document is provided as is without warranty of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability, fitness for a particular purpose, or non-infringement. This publication could include technical inaccuracies or typographical errors. Changes are periodically added to the information herein; these changes will be incorporated in new editions of the document. Bluesocket inc. may make improvements or changes in the products or the programs described in this document at any time. Trademarks Bluesocket, The Bluesocket Logo, Secure Mobility, BlueView, BlueSecure, HighDataDensity, DynamicRF, and CellularLAN are trademarks or registered trademarks of Bluesocket, Inc. All other trademarks, trade names and company names referenced herein are used for identification purposes only and are the property of their respective owners. Publication Date: September 23, 2007 ii Contents Overview .................................................................................................1 Familiarizing Yourself with the BSAP Hardware ............................................2 Fixed Antennas......................................................................................3 LED Indicators .......................................................................................3 Power Supply Connector ........................................................................3 Ethernet/PoE Connector .........................................................................4 Reset Button ..........................................................................................4 Console Port .........................................................................................5 Kensington Security Slot..........................................................................5 Provisioning Your Bluesocket WLAN for BSAPs .............................................5 Deploying BSAPs on the Same Layer-2 Subnet as the BSC ..........................5 Deploying BSAPs with Layer-3 Connectivity to the BSC ...............................6 Selecting a BSAP Installation Location ..........................................................7 Mounting the BSAP....................................................................................8 Dropped Ceiling Tool requirements ..........................................................8 Conventional Ceiling Tool requirements....................................................8 Mounting Kit Contents ............................................................................9 Dropped Ceiling Kit Installation ...............................................................9 Ceiling Kit Installation...........................................................................13 Mounting on a Wall.............................................................................17 Connecting and Powering the BSAP ..........................................................19 Using the BSAP Command Line Interface (CLI).............................................20 Accessing the BSAP CLI ........................................................................20 Navigating the BSAP CLI ......................................................................21 BSAP Default Configuration...................................................................21 Setting the BSAP and Home BSC IP Addresses Using the CLI .....................22 Using the BSAPs Site Survey Mode .......................................................23 General Specifications.............................................................................24 Declarations of Conformity and Regulatory Information................................27 Safety Warnings for BlueSecure Access Point 1800 .................................31 BlueSecure Access Point 1700 Installation Guide iii Contents iv Overview The BlueSecure Access Point 1800 is a next-generation, thin access point that works in conjunction with BlueSecure Controllers (BSCs) for enterprise wireless LAN (WLAN) deployments. The BlueSecure Access Point 1800 features dual radios supporting 802.11a and 802.11b/g in a plenum-rated housing, with an embedded MIMO antenna panel under the top cover of the AP. BSAPs are simple to configure and require only minimal provisioning to make them fully operational on a WLAN secured and managed by a BlueSecure Controller BSAPs can be directly attached to any existing Layer-2 or Layer-3 Ethernet switch and communicate with the BSC across any subnet boundary. Once the BSAP has discovered and established Layer-2 or Layer-3 communication with its home (i.e., host) BlueSecure Controller, advanced configuration and provisioning may be applied either to individual BSAPs or globally across the entire WLAN using the BSCs web-based Administrator Console. Figure 1: BSAPs Automatically Discover BSCs Across L2/L3 Networks Once a BlueSecure Access Point has downloaded its configuration from its home BlueSecure Controller, the BSAP and the BSC will establish a tunnel through which all wireless client traffic received by the BSAP will pass for the application of policy by the BSC. This guide provides complete installation procedures for your BSAP including:
familiarizing yourself with the BSAP hardware provisioning your Bluesocket WLAN for BSAPs selecting a BSAP installation location connecting and powering the BSAP using the BSAP command line interface (CLI) BlueSecure Access Point 1800 Installation Guide 1 Familiarizing Yourself with the BSAP Hardware Figure 2 illustrates the BSAP hardware. Familiarize yourself with the labeled components before attempting to install the BSAP. Figure 2: BSAP Hardware Components 2 Familiarizing Yourself with the BSAP Hardware Fixed Antennas The BSAP-1800 utilizes an embedded MIMO antenna panel under the top cover of the AP for wireless communications. There are three elements for each band. All elements are used for both transmit and receive operations. LED Indicators The following grouping of LED indicators is located on the top of the BSAP-1800 housing:. The two status LEDs together indicate the following software operational modes, depending on whether each LED is off, on, or blinking:
Table 1: BSAP Status LEDs Left Status LED Right Status LED Indicates Off On Blinking On Blinking Off Off Off On Failure Waiting for IP Address BSC discovery in progress System is operational Blinking Software download in progress Link1 refers to the 802.11b/g Link and Link 2 refers to the 802.11a Link. When the LED is on, it indicates that the unit is on and the radio active (note that when unit is booting, the LED defaults to on even though the radio is disabled). Activity 1refers to 802.11b/g Activity and Activity 2 refers to 802.11a Activity. When the LED is on, it indicates data activity on the Ethernet link. Power Supply Connector The BSAP does not have a power switch. It is powered on when connected to the supplied AC power adapter, and the power adapter is connected to a power source. The BSAP automatically adjusts to any voltage between 100-240 volts at 50 or 60 Hz. No voltage range settings are required. BlueSecure Access Point 1800 Installation Guide 3 The BSAP may also receive Power over Ethernet (PoE) from a model BSC-400 Controller, switch or other network device that supplies power over the network cable based on the IEEE 802.3af standard. Ethernet/PoE Connector The BSAP-1800 has one auto-sensing 10BASE-T/100BASE-TX/1000BaseT RJ-45 connector that can be attached directly to 10BASE-T/100BASE-TX/1000BaseT switches to provide a full-duplex link. These segments must conform to the IEEE 802.3 or 802.3u specifications. This connector uses an MDI (i.e., internal straight-through) pin configuration. You can use straight-through twisted-pair cable to connect this port to most network interconnection devices such as a switch or router that provide MDI-X ports. However, when connecting the BSAP to a workstation or other device that does not have MDI-X ports, you must use crossover twisted-pair cable. The BSAP appears as an Ethernet node and performs a bridging function by moving packets from the wired LAN to remote workstations on the wireless infrastructure. The Ethernet/PoE RJ-45 connector also supports Power over Ethernet (PoE) based on the IEEE 802.3af standard. Note that if the BSAP is connected to a PoE source device and also connected to a local power source through the AC power adapter, PoE will be disabled. If the AC power source is removed, the unit begins to take power from POE. 802.3af specifies Power over Ethernet for mid-span, where PoE inserters are located in the path between the network and the AP, as well as DCE, where the power is supplied by the network switch the AP is attached to. Mid-span devices typically provide power on the unused pairs (4+5 & 7+8), where a PoE LAN switch will most likely provide power to the AP on the data pairs (1+2 & 3+6). If the BSAP-1800 is connected to a PoE LAN switch at either 10BaseT, 100BaseT, or 1000BaseT, and the switch is configured to supply 802.3af standard PoE, the BSAP-1800 will power on and operate correctly. If the BSAP-1800 Ethernet interface is running in either 10BaseT or 100BaseT mode, any standard-based 802.3af mid-span power inserter will work properly, including Bluesockets BSAP-
POE-000-00-0 Mid-Span PoE Inserter. A complication may arise when using the BSAP-1800 with the Ethernet interface running in 1000BaseT mode. If a mid-span device is used, the device must be compatible with 1000BaseT, such as the Bluesocket model POE-001-00-0, 1000BaseT Mid-Span PoE Inserter. 1000BaseT Ethernet uses all 4 pairs, therefore, 10BaseT / 100BaseT mid-span power inserters incompatible, and will break the communications path between the BSAP-1800 and the network. Reset Button Use this button to reset the BSAP or restore its factory default configuration. If you hold down the button for less than 5 seconds, the BSAP will perform a hardware reset. If you hold down the button for 5 seconds or more, any configuration 4 Provisioning Your Bluesocket WLAN for BSAPs changes you may have made are removed, and the factory default configuration is restored to the BSAP. Console Port The BSAP-1800s console port is available through the Ethernet interface. Kensington Security Slot The BSAP includes a Kensington security slot on the side panel. You can prevent unauthorized removal of the BSAP by wrapping a Kensington security cable (not provided) around an unmovable object, inserting the lock into the slot, and turning the key. Provisioning Your Bluesocket WLAN for BSAPs There are prerequisites that must be met before deploying BSAPs in a live network environment. These prerequisites ensure that the BSAPs are able to discover and connect to a host BlueSecure Controller. Implementing these prerequisites also relieves you from the need to manually configure each deployed BSAP. The deployment prerequisites for BSAPs are:
BSAP IP Address - Each BSAP requires a unique IP address. Host BlueSecure Controller IP Address - Each BSAP also needs the IP address of the host BSC to which it will connect and from which it will obtain its software image and configuration. This section describes how to provision your Bluesocket WLAN when deploying BSAPs:
on the same Layer-2 subnet as the BSC across a routed network with Layer-3 connectivity to the BSC Deploying BSAPs on the Same Layer-2 Subnet as the BSC If the BSAPs are on the same subnet as the home BlueSecure Controller as shown in Figure 3, you can run a DHCP server on the BSC to manage IP address assignment to BSAPs. In this scenario, the BlueSecure Controller must be the only DHCP server for the subnet. Alternatively, you can configure the BlueSecure Controller to run a DHCP relay agent to relay DHCP communications between the BSAPs and a DHCP server on your network. When you run a DHCP server or a DHCP relay agent on the BSC to assign IP addresses to BSAPs on the managed side, the BSC will also pass its IP address to the BSAPs automatically using vendor-specific option 43. The BSAP will then connect to the IP provided by the DHCP vendor option as its host BSC. See the BlueSecure Controller Setup and Administration Guide for detailed DHCP server and DHCP relay agent configuration procedures. BlueSecure Access Point 1800 Installation Guide 5 Run a DHCP Server or a DHCP Server Relay Agent on the BSC BSAPs will Automatically Discover and Communicate with their Home BSC Figure 3: Deploying BSAPs on the Same Layer-2 Subnet as the BSC In this deployment scenario, simply connect and power on the BSAPs. They will automatically discover and communicate with their home BSC. Deploying BSAPs with Layer-3 Connectivity to the BSC You can also deploy BSAPs on a routed network with Layer-3 connectivity to the BSC as shown in Figure 4. BSAPs Receive their IP Addresses from Network DHCP Server BSAPs Receive Home BSC IP Address Using DHCP Option 43 or DNS Network DHCP Server Network DNS Server Figure 4: Deploying BSAPs Across a Routed Network In this deployment scenario, you must ensure that each BSAP is able to communicate with the BSC across the routed network by verifying that:
there are no NAT devices between the BSAPs and the BSC Protocol 97, UDP Port 53, and TCP/UDP Port 33333 traffic is allowed between the BSAPs and the BSC Each BSAP will receive its IP address from your existing network DHCP server. An exception case is if the BSAP is beyond a managed side router, running IP helper. Then the BSAP will receive its IP address from the BSC, and be able to discover it without any additional configuration. 6 Selecting a BSAP Installation Location The BSAP also needs the IP address of the home BSC to which it will connect and from which it will obtain its software image and configuration. Again, this is not needed if the BSAP is on the managed side getting a relayed IP address from the BSC. You can provide the home BSC IP address to a BSAP using one of the following methods:
DHCP Server Option 43 - You can manually configure the DHCP server on your network to send BSC IP addresses to BSAPs using DHCP vendor-
specific option 43. In DHCP requests sent from the BSAP, the BSAP uses option 60 Vendor class identifier with a value of BlueSecure.AP1500 to identify itself to the DHCP server (Note that all BSAPs 1500,1540,1800 identify as AP1500 for option 43). Refer to the documentation supplied with your DHCP server when configuring vendor-specific option 43 DNS Server Configuration - BSAPs are factory configured with apdiscovery as the DNS hostname. You can configure a DNS server on your network with an entry for apdiscovery with the home BSC Controller IP address as the resolution. To configure this, add a NAME record to the DNS server for apdiscovery (at the domain server that the BAP will receive). Point this name to one or more BSC IP addresses (managed, protected or VLAN depending on the network configuration). So for example, if there are two BSCs (192.168.100.23 and 192.168.100.28), and the domain is customer.com, add two NAME records to customer.com, for the name apdiscovery.customer.com. One should resolve to 192.168.100.23 and one to 192.168.100.28. PTR (i.e., pointer) records are not needed for this portion of discovery. Selecting a BSAP Installation Location BlueSecure Access Points should be positioned for maximum throughput and range between other BSAPs and wireless client devices. Normally, you should locate the BSAP on the ceiling away from obstructions. Range and performance are dictated by the distance between the BSAP and client radios, and by obstacles that may be present in a specific building or office environment. The following positioning guidelines are suggested:
Document all the BSAPs and client devices you wish to include in your wireless network. Record the MAC address, serial number, and placement of each BSAP. Wired LAN and power connections must be available for each BSAP at the desired installation location. If a power outlet is not available near the access point, mid-span power inserters are recommended. If building blueprints or floor plans are available, use them to define potential client device locations and likely roaming areas. Identify possible obstacles or sources of interference that could affect signal strength (for example, walls, metal objects). BlueSecure Access Point 1800 Installation Guide 7 Install the BSAP in an area where large steel structures such as beams, pillars, shelving units, bookcases, and filing cabinets do not obstruct radio signals to and from the BSAP. Determine optimal AP placement using Bluesockets Wireless LANPlanner software. LANPlanner enables network planners to import a map of the facility, note the contents and construction materials, designate user regions and applications to be used and place equipment. The designer then interactively simulates how the wireless signals will propagate and fine-tunes the network design with what if analysis to determine optimum performance. Please consult Bluesockets web site for additional information, and to download free trial software. Once BSAPs have been installed and configured, use site survey and monitoring utilities supplied with the client adapters to test signal strength at various locations. Modify the positioning of the BSAPs and client stations as required for optimum performance. Mounting the BSAP The BSAP-1800 contains a panel antenna that was designed to accommodate either ceiling or wall mount installations. The panel antennas radiation pattern is focused completely in front of the antenna rather than behind the unit. In order to provide even coverage of an area similar to an omni-directional antenna, it is recommended that the antenna is installed in the ceiling where the energy is pushed in all directions toward the horizon and below the unit. If the BSAP-1800 is installed on a wall, the antenna is more directional than omni-
directional. The energy is mainly pushed in the direction that the antenna is facing and very little energy (if any) is pushed behind the unit. In this orientation, more BSAP-1800s are required to provide a uniform coverage area similar to deployments of sector antennas. Dropped Ceiling Tool requirements 1. Utility Knife 2. Phillips Screwdriver 3. Masking Tape 4. Tile Cut-Out Template (provided) 5. Metal Ruler or Straight-Edge. Conventional Ceiling Tool requirements 1. Phillips Screwdriver 2. Drill 3. 3/16" Drill Bit 4. Hammer 5. Masking Tape 6. Hole location Template (provided) 8 Mounting the BSAP 7. Pencil Mounting Kit Contents The following figure depicts the contents of the mounting kit. Refer to the table below the figure for a description of each numbered item shown in the figure. Figure 5: Mounting Kit Contents Item Description Qty. 1 2 3 4 5 6 7 Ceiling Tile, Trim Plate Rear Mounting Plate Side Mounting Bracket
#6 x 5/16" Screw, Phillips Pan Hd
#6-32x1/4" Screw, w/Ext Tooth Washer
(Used only when mounting directly to ceiling)
#8x3/4" Sheet Metal Screws Plastic Anchors 2 1 2 4 4 4 4 Dropped Ceiling Kit Installation 1. Remove tile from suspended ceiling. Turn tile so you are looking at the back side. Position the template provided, and tape it to the back of the ceiling tile. Using a utility knife and a metal ruler, cut out the hole needed for the BSAP-
1800 unit. The cut-out tile should look like the picture below. BlueSecure Access Point 1800 Installation Guide 9 Figure 6: Finished Side of Tile 2. Fasten the Rear Mounting Plate to the bottom of the BSAP-1800 unit using the 4 #6x5/16" screws provided. Over-tightening of screws will cause stripping of threads formed in plastic (see Figure 7). Figure 7: Installing Rear Mounting Plate 10 3. Slide the Trim Plates into the grooves of the BSAP-1800 unit as shown in Figure 8. Slide each half of the trim plate until the halves click into place. Mounting the BSAP Figure 8: Trim Plate Installation 4. Turn BSAP-1800 unit over and place ceiling tile over the unit as shown in Figure 9. The Trim Plates will aide in tiles correct position. Next attach the Side Mounting Brackets to the Rear Mounting Plate using the 6-32 screws with the external tooth washers attached. Figure 9: Side Mounting Bracket Installation 5. Bring entire assembled kit (including tile) to suspended ceiling and attach LAN cable into BSAP-1800 unit as shown in Figure 10. If cable is tight, shift unit until cable has enough relief. After cable is wired in, place ceiling tile back to desired location. The assembly may need to shift so trim plate will cover all openings in the ceiling tile. BlueSecure Access Point 1800 Installation Guide 11 Figure 10: Finished Side of Tile Figure 11: BSAP-1800 Installed 12 Mounting the BSAP Ceiling Kit Installation 1. To install plastic anchors, mark the ceiling using the template provided. Next drill 4 pilot holes for the plastic anchors. Figure 12: Plastic Anchor holes BlueSecure Access Point 1800 Installation Guide 13 2. Figure 13Push Anchors into holes until they are flush. Attach the side brackets to the ceiling using the 1" sheet metal screws. Check the alignment of the side brackets by sliding the rear plate between the two brackets. Once a good fit has been established, tighten side brackets to ceiling. Use this plate to check fit Figure 13: Side Bracket Installation 14 3. Fasten the Rear Mounting Plate to the bottom of the BSAP-1800 unit using the 4 #6x5/16" screws provided as shown in Figure 14. Over-tightening of screws, will cause stripping of threads formed in plastic. Mounting the BSAP Figure 14: Installing Rear Mounting Plate BlueSecure Access Point 1800 Installation Guide 15 4. Attach BSAP-1800, with rear plate installed, to the side plates as shown in Figure 15. Secure the assembly using #6x1/4" screws with tooth washers. Figure 15: Attaching Rear Plate to Side Brackets 16 Mounting the BSAP Mounting on a Wall 1. Using Bracket provided, mark wall for anchor placement. Drill a 6mm pilot hole for the plastic anchor (see Figure 16). Figure 16: Marking Wall and Drilling Pilot Hole BlueSecure Access Point 1800 Installation Guide 17 2. Tap anchors into holes until they are flush to the wall. Using Flat-head screws provided, mount bracket to the wall as shown above. Do not fully tighten screws until both have been installed (see Figure 17). Figure 17: Mounting Wall Bracket 18 Connecting and Powering the BSAP 3. Using hooks provided on bracket, position BSAP-1800. Notice the wall mount grooves on the back of the BSAP-1800 (see Figure 18). Figure 18: Positioning BSAP-1800 on Hooks Connecting and Powering the BSAP Follow these instructions to connect your BlueSecure BSAP to your Bluesocket WLAN and then power it up:
1. Make a note of the 12-character MAC address and the serial number listed on the bottom of the BSAP before mounting the BSAP to a wall or other surface. You will need this information during configuration. 2. Position the BSAP-1800 for best radio performance. The BSAP-1800 utilizes a 6-element MIMO antenna panel under the top cover of the unit. This antenna panel is made up of a combination of horizontally and vertically polarized antenna elements, which should give excellent performance regardless of the orientation of the AP. The BSAP-1800 should, however, be place where it has the best unobstructed view of the coverage area. If possible, mounting the BSAP-1800 on the ceiling will provide the best performance in a typical office environment. An optional ceiling tile mounting kit is available for the BSAP-1800, which provides for a very esthetically pleasing and professional looking installation. For more information, please refer to Bluesockets web site. 3. The BSAP derives its operating power directly from the RJ-45 connector when connected to a device that provides IEEE 802.3af compliant Power over Ethernet (PoE). BlueSecure Access Point 1800 Installation Guide 19 Caution: If the BSAP is used in a medical environment, it must use an IEC/
EN60601-1 compliant power adapter. See page 24 for a description of the IEC/EN60601-1 compliant power adapter available from Bluesocket. 4. Verify that the PWR LED stops flashing and remains on, and that the other status LEDs start functioning as described in the section entitled LED Indicators on page 3. 5. Connect the BSAP to your Bluesocket WLAN. You can connect the BSAP-1800 to a 10/100 Mbps Ethernet through a network device such as a hub or a switch, or to a 1000BaseT Gigabit Ethernet interlace. Connect the RJ-45 Ethernet connector on the BSAPs back panel to your network using category 3, 4, or 5 UTP Ethernet cable. When the BSAP and the connected device are powered on, the BSAPs Ethernet Link LED should light indicating a valid network connection.
Note: The RJ-45 port on the BSAP provides a full-duplex Ethernet connection using an MDI pin configuration, so you must use a straight-through cable for network connections to hubs or switches that only have MDI-X ports, and a crossover cable for direct network connections to BSC-400s, PCs, servers or other end nodes that only have MDI ports. However, if the device to which you are connecting supports auto-MDI/MDI-X operation, you can use either a straight-through or crossover cable. Using the BSAP Command Line Interface (CLI)
Note: Normally you will not need to access the BSAP CLI. In a properly provisioned Bluesocket WLAN, the BSAP will automatically discover and communicate with its home BSC. We recommend that you use the CLI to configure the BSAP only in a lab or test environment, or where a pre-defined static IP address is desired. You can connect a console to the BSAPs Ethernet port to perform local configuration of the BSAP using its command line interface (CLI).You can use the BSAPs CLI to manually configure:
the BSAPs IP address the IP address of the home BSC from which the BSAP will download its configuration and software image Site survey mode Accessing the BSAP CLI Access the BSAP CLI using an SSH client (the example uses putty) For example:
1. The default management IP address for the AP-1800 is 192.168.190.1. Configure your laptop computer to have a static IP address in this same subnet, for example 192.168.190.2. 2. Ping the AP from the laptop to make sure it can be seen. 3. Configure putty to use SSH and then connect to the IP address of the AP (by default 192.168.190.1) on port 2335. 20 Using the BSAP Command Line Interface (CLI) 4. Enter the following username and password in lowercase at the displayed CLI login prompts:
BlueAP login: adm1n (i.e., adm one n) Password: blue1socket (i.e., blue one socket). Figure 19: PuTTY Configuration Navigating the BSAP CLI The BSAP CLI main menu provides access to these options:
Network Configuration - Configure the BSAPs network settings including its IP address and the IP address of the BSC to which it will connect. Save/Apply Configuration - After you have configured the BSAPs network settings, you must apply them before they become active. Restore Defaults - Restore the BSAP to its default settings. Show Version Information - Display BSAP version information. Reboot AP - After applying the BSAPs configuration settings, you must reboot the BSAP to effect the new configuration. Site Survey Configuration - In site survey mode, the BSAP beacons known SSIDs on its 802.11a and 802.11 b/g radios operating at a configurable power level and channel to facilitate a WLAN site survey. Rebooting the BSAP following a site survey, restores the BSAPs existing configuration. See page 23 for details on using the BSAPs site survey mode. When operating in a submenu, press h to return directly to the main menu (or home menu). Press p to return to the previous menu. BSAP Default Configuration The BSAP is shipped with the following default configuration. IP_ADDR_MODE:
DHCP (0) BlueSecure Access Point 1800 Installation Guide 21 0.0.0.0 IP_ADDR 0.0.0.0 NETMASK 0.0.0.0 GW_ADDR 0.0.0.0 DNS_ADDR Discover BSC (0) WG_ADDR_MODE 0.0.0.0 WG_ADDR MNGMT_IP_ADDR 192.168.190.1 The two options for IP address mode are:
(0) DHCP - The BSAP runs a DHCP client and receives its IP address from a DHCP server.
(1) Static IP - You assign the BSAP a static IP address via its CLI. The two options for WG address mode are:
(0) Discover - The BSAP automatically discovers the IP address of the BSC to which it is to connect.
(1) Static Configuration - Using the BSAP CLI, you will configure the IP address of the BSC to which the BSAP is to connect. Setting the BSAP and Home BSC IP Addresses Using the CLI To set the BSAP and Home BSC IP addresses using the CLI:
1. Enter 1 at the BSAP CLI main menu command prompt. The BSAP CLI network configuration menu appears:
Figure 20: BSAP CLI Network Configuration Menu 2. Enter 1 at the Network Cfg prompt to set the IP address mode. Enter 1 to set the BSAP IP address mode to static. 3. Enter 2 at the Network Cfg prompt to set the BSAPs IP address. Enter the BSAP IP address and subnet mask using the format:
<address> netmask <netmask>
22 Using the BSAP Command Line Interface (CLI) 4. Enter 3 at the Network Cfg prompt to specify the BSAPs default IP gateway. 5. Enter 4 at the Network Cfg prompt to specify the IP address of the BSAPs primary DNS server. 6. Enter 5 at the Network Cfg prompt to specify the BSC mode, i.e. how the BSAP is to obtain the IP address of its home BSC. You can set the BSC mode to either Discover or Static BSC. Enter 1 to set the BSC mode to Static BSC. 7. Enter 6 at the Network Cfg prompt to specify the IP address of the BSAPs home BSC. 8. Enter 8 at the Network Cfg prompt to review the BSAP network configuration settings you have made. The network summary includes the MAC addresses of the BSAPs Ethernet and wireless interfaces. 9. Enter p at the CLI prompt to return to the main menu. Enter 2 at the main menu to apply your configuration changes, reboot the BSAP, and put the new configuration settings into effect. When the BSAP completes its reboot, it will connect to and download its configuration from the home BSC you have configured via the CLI. Using the BSAPs Site Survey Mode The BSAP provides a site survey mode that is useful when you are conducting a site survey to determine optimal RF coverage for your facility. In site survey mode, the BSAP continually beacons the SSID site_survey_chn#_pwr# from its 802.11a and 802.11 b/g radios at a rate of 100 milliseconds. Here are the options to configure site survey mode:
1. Select Option a from the main menu to enter the site survey sub-menu. 2. Select the Interface (11b/g or 11a) to configure. All the radio settings that are configured after this interface is setup will apply to the configured interface. 3. Set Antenna Type (Doesnt apply to the 1800). 4. Set Channel - channel to transmit the beacons. 5. Set Transmit Power - transmit power of the beacons levels 0-10. 6. Enable Site Survey Mode Once you setup the channel and transmit power, the settings are applied once you enable it with this option. 7. Site Survey Summary View your current site survey settings. Rebooting the BSAP following a site survey, restores the BSAPs existing configuration. BlueSecure Access Point 1800 Installation Guide 23 Figure 21: BSAP CLI Network Configuration Menu General Specifications Power Supply Standard Input: AC100-240V~, 50-60Hz, 0.5A Output: DC48V, 0.31A Input: +48VDC via wall adapter (BSAP-PWR-000-00-0) or Power Over Ethernet
(POE). Max power consumption: 250 mA @ 48 VDC, 12 Watts Note: If the wall adapter applies power to the BSAP-1800 before the Power Sourcing Equipment (PSE), it prevents the PSE from detecting the BSAP-1800. If the PSE is already powering the BSAP-1800 when the wall adapter is plugged in, priority is given to the higher supply voltage. European Medical Environment If you require compliance with EN60601-1 (European Medical Device Standard), either use Power over Ethernet (PoE) or the following power adapter that complies with IEC/EN60601-1 and is available from Bluesocket. Manufacturer/Model: MEAN WELL/MES30A-8P1J Input: 100-240VAC, 50-60Hz, 0.8-0.4A Output: 48VDC, 0.62A PoE (DC)
Input voltage: 48 volts, 0.25 A, 12 watts Note: Power can also be provided to the access point through the Ethernet port based on IEEE 802.3af Power over Ethernet (PoE) specifications. When both PoE is provided and the adapter is plugged in, PoE will be turned off. 24 General Specifications Dimensions Length: 9 in. (22.9 cm) Width: 9in. (22.9 cm) Height: 2 in. (5.1 cm) Weight 2 lbs. (0.907 kilograms) LED Indicators PWR (Power), Ethernet Link (Ethernet Link/Activity), 802.11a wireless link and activity, 802.11b/g wireless link and activity, and (2) status indicators. Network Management The BSAP-1800 can be managed by any of the BlueSecure Controllers, BlueView Management System (BVMS), or through the BSAP-1800s local console interface. Temperature Operating: 0 to 55 C (32 to 131 F) Storage: 0 to 70 C (32 to 158 F) Wireless Communications Wireless Speeds:
802.11b 1/2/5.5/11Mb/s 802.11g 1/2/5.5/6/9/11/12/18/24/36/48/54 Mb/s 802.11a 6/9/12/18/24/36/48/54 2.4 GHz MIMO 24/36/40/42/48/72/80/84/96/108/120/126 2.4 GHz MIMO utilizing Adaptive Channel Expansion 48/72/80/84/96/144/160/168/192/216/240 5 GHz MIMO 24/36/40/42/48/72/80/84/96/108/120/126 Modulation Type: DSSS, OFDM,BPSK, QPSK, CCK, 16QAM, 64QAM Operating Frequency: 2.400~2.4835GHz, 5.15~5.25GHz & 5.725~5.850GHz Channel Numbers: 11 (for 2.4GHz Band); 8 for normal mode (for 5GHz Band) Transmitter Output Power:
+22dBm (for 2.4GHz Band)
+20dBm (for 5.15~5.25GHz Band)
+20dBm (for 5.725~5.850GHz Band) BlueSecure Access Point 1800 Installation Guide 25 Compliance Safety UL 60950 CAN/CSA C22.2 No. 60950 IEC 60950 EN 60950 UL 2043 EMI & Susceptibility Class B FCC Part 15.107 and 15.109 ICES-003 (Canada) EN 301.489-1 and -17 (Europe) EN60601-1-2 EN5502 & EN55024 EN6100-3-2, -3-3, Radio Approvals FCC Part 15.247 and 15.407 FCC ID Registration and ID Number EN 300.328, EN 301.893 (Europe) RSS-210 (Canada) EU Notification Body Letter 26 Declarations of Conformity and Regulatory Information Declarations of Conformity and Regulatory Information FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters (8 inches) between the radiator (antenna) and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. For operation within 5.15 ~ 5.25GHz frequency range, it is restricted to indoor environment. IEEE 802.11b or 802.11g operation of this product in the U.S.A. is firmware-limited to channels 1 through 11. Industry Canada Statement Operation is subject to the following two conditions:
1) This device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. This device has been designed to operate with an antenna having a maximum gain of 8 dB. Antenna having a higher gain is strictly prohibited per regulations of Industry Canada. The required antenna impedance is 50 ohms. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the EIRP is not more than required for successful communication. BlueSecure Access Point 1800 Installation Guide 27 Because high power radars are allocated as primary users (meaning they have priority) in 5250-5350 MHz, these radars could cause interference and/or damage to license exempt LAN devices. This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters (8 inches) between the radiator (antenna) and your body. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC English:
Deutsch:
Dansk:
Espaol:
Franais:
slenska:
Italiano:
This equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Dieses Gert entspricht den grundlegenden Anforderungen und den weiteren entsprecheneden Vorgaben der Richtlinie 1999/5/EU. Dette udstyr er i overensstemmelse med de vsentlige krav og andre relevante bestemmelser i Directiv 1999/5/EF. Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive 1999/5/EC. Cet appareil est conforme aux exigencies essentialles et aux autres dispositions pertinantes de la Directive 1999/5/EC. essi bnaur samrmist lgbonum krfum og rum kvum tilskipunar 1999/5/ESB. Questo apparato conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/EC. Nederlands:
Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 1999/5/EC. Norsk:
Portugus:
Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-directiv 1999/5/EC. Este equipamento satisfaz os requisitos essenciais e outras provises da Directiva 1999/5/EC. Suomalainen:
Tm laite tytt direktiivin 1999/5/EY oleelliset vaatimukset ja on siin asetettujen muidenkin ehtojen mukainen. Svenska:
Denna utrustning r i verensstmmelse med de vsentliga kraven och andra relevanta bestmmelser i Direktiv 1999/5/EC. Radio: EN 301 893 and EN 300 328 (if applicable) EMC: EN 301 489-1 and EN 301 489-17 Safety: EN 60950 and EN 50385 The following standards were applied during the assessment of the product against the requirements of the Directive 1999/5/EC:
Note: This equipment is intended to be used in all EU and EFTA countries. Outdoor use may be restricted to certain frequencies and/or may require a license for operation. For more details, contact Bluesocket, Inc. 28 Declarations of Conformity and Regulatory Information National Restrictions In the majority of the EU and other European countries, the 2.4- and 5-GHz bands have been made available for the use of wireless LANs. Table 2 provides an overview of the regulatory requirements that apply to the 2.4- and 5-GHz bands. Later in this section you will find an overview of countries in which additional restrictions or requirements or both apply. The requirements for any country may evolve. Cisco recommends that you check with local authorities for the latest status of their national regulations for both 2.4- and 5-GHz wireless LANs. Table 2: Overview of Regulatory Requirements for Wireless LANs Frequency Band
(MHz) Max Power Level
(EIRP)a (mW) Indoor ONLY Indoor and Outdoor 2400-2483.5 5150-53502b 5470-57251 100 200 1000 X X X a. Effective isotropic radiated power (EIRP). b. Dynamic Frequency Selection and Transmit Power Control is required in the 5250- to 5350-MHz and 5470- to 5725-MHz frequency range. The following sections identify countries having requirements or restrictions in addition to those listed in Table 2. Belgium The Belgian Institute for Postal Services and Telecommunications (BIPT) must be notified of any outdoor wireless link having a range exceeding 300 meters. Bluesocket recommends checking http://www.bipt.be for more details. Draadloze verbindingen voor buitengebruik en met een reikwijdte van meer dan 300 meter dienen aangemeld te worden bij het Belgisch Instituut voor postdiensten en telecommunicatie (BIPT). Zie http://www.bipt.be voor meer gegevens. Les liaisons sans fil pour une utilisation en extrieur d'une distance suprieure 300 mtres doivent tre notifies l'Institut Belge des services Postaux et des Tlcommunications (IBPT). Visitez http://www.ibpt.be pour de plus amples dtails. France For 2.4 GHz, the output power is restricted to 10 mW EIRP when the product is used outdoors in the band 2454 to 2483 MHz. There are no restrictions when used indoors or when used in other parts of the 2.4 GHz band. For 5 GHz, the frequency bands 5150 to 5350 MHz and 5470 to 5725 MHz will become fully available by November 1, 2005. Until then, only the band 5150 to 5350 MHz is available. Check http://www.arcep.fr/ for more details. BlueSecure Access Point 1800 Installation Guide 29 Pour la bande 2,4 GHz, la puissance est limite 10 mW en p.i.r.e. pour les quipements utiliss en extrieur dans la bande 2454 - 2483,5 MHz. Il n'y a pas de restrictions pour des utilisations en intrieur ou dans d'autres parties de la bande 2,4 GHz. A 5 GHz, les bandes 5150-5350 MHz et 5470-5725 MHz deviendront entirement disponibles au 1er novembre 2005. D'ici l, seule la bande 5150-
5350 MHz est disponible. Consultez http://www.arcep.fr/ pour de plus amples dtails. Germany Amtsbl/Vfg 89/2003 Frequenzbereich: 2400 MHz - 2483,5 MHz
- Maximale Strahlungsleistung: 100 mW
- Maximale spektrale Leistungsdichte bei Direktsequenz Speektrumsspreiz-
verfahren (DSSS) und anderen Zugriffsverfahren:10 mW/1 MHz Einzuhalten ist: ETSI EN 300328 und CEPT/ERC-Empfehlung 70-03
Amtsbl/Vfg 35/2002 1. Frequenzbereich 5150 - 5350 MHz Maximal zulssige mittlere quivalente isotrope Strahlungsleistung (EIRP) 200 mW 1) Kanalraster 20 MHz Kanalbandbreite 20 MHz Nutzung ausschlielich innerhalb geschlossener Rume 2. Frequenzbereich 5470 - 5725 MHz Maximal zulssige mittlere quivalente isotrope Strahlungsleistung (EIRP) 1 W 2)Kanalraster 20 MHz Kanalbandbreite 20 MHz Nutzung sowohl innerhalb als auch auerhalb geschlossener Rume 3. Weitere Bedingungen zur Vermeidung von Strungen bei anderen Funkanwendungen, die innerhalb der o. g. Frequenzbereiche Betrieben werden. Regelbereich der automatischen Leistungsregelung (mindestens), bezogen auf 200 mW bzw. 1 W entsprechend Nr. 1 und Nr. 2 6 dB Dynamisches Frequenzwahlverfahren 3)in Verbindung mit einer Verteilung der Verkehrslast in Abhngigkeit der genutzten Frequenzbereiche
bei Nutzung beider Frequenzbereiche entsprechend Nr. 1 und Nr. 2 auf mindestens 14 Kanle bei Nutzung des Frequenzbereichs entsprechend Nr. 2 auf 11 Kanle 4. Sonderfall, falls ausschlielich der Frequenzbereich 5150 - 5250 MHz ohne dynamisches Frequenzwahlverfahren genutzt wird. Maximal zulssige mittlere quivalente isotrope Strahlungsleistung (EIRP) mit automatischer Leistungsregelung, Regelbereich mindestens 6 dB (bezogen auf 60 mW)60 mW 4) Maximal zulssige mittlere quivalente isotrope Strahlungsleistung (EIRP) ohne automatische Leistungsregelung 30 mW 4) Kanalraster 20 MHz Kanalbandbreite 20 MHz Nutzung ausschlielich innerhalb geschlossener Rume
1) Bei Kanalbandbreiten < 20 MHz darf die mittlere spektrale Leistungsdichte (EIRP/MHz) nicht grer sein als 10 mW pro 1 MHz. 2) Bei Kanalbandbreiten < 20 MHz darf die mittlere spektrale Leistungsdichte (EIRP/MHz) nicht grer sein als 50 mW pro 1 MHz. 30 Safety Warnings for BlueSecure Access Point 1800
3) Das dynamische Frequenzwahlverfahren dient insbesondere der Vermeidung von Gleichkanalbetrieb mit Radarsystemen. 4) Bei Kanalbandbreiten < 20 MHz darf die mittlere spektrale Leistungsdichte (EIRP/MHz) nicht grer sein als 3 mW pro 1 MHz bei Systemen mit automatischer Leistungsregelung bzw. 1,5 mW pro 1 MHz bei Systemen ohne automatische Leistungsregelung. Greece A license from EETT is required for the outdoor operation in the band 5470 to 5725 MHz. Bluesocket recommends checking http://www.eett.gr for more details. Italy
This product meets the National Radio Interface and the requirements specified in the National Frequency Allocation Table for Italy. Unless this wireless LAN product is operating within the boundaries of the owner's property, its use requires a
"general authorization." Please check with http://www.comunicazioni.it/it/ for more details. Questo prodotto conforme alla specifiche di Interfaccia Radio Nazionali e rispetta il Piano Nazionale di ripartizione delle frequenze in Italia. Se non viene installato all'interno del proprio fondo, l'utilizzo di prodotti Wireless LAN richiede una "Autorizzazione Generale". Consultare http://www.comunicazioni.it/it/ per maggiori dettagli. Note: Although Norway, Switzerland, and Liechtenstein are not EU member states, the EU Directive 1999/5/EC has also been implemented in those countries. Note: The regulatory limits for maximum output power are specified in EIRP
(radiated power). The EIRP level of a device can be calculated by adding the gain of the antenna used (specified in dBi) to the output power available at the connector (specified in dBm).
Countries within the EU with restricted use of the ISM Band frequency range include: CH, DE, DK, FR, FI, GB, IS, NO, NL, PT, SE, BE Safety Warnings for BlueSecure Access Point 1800 This section provides translations of the following safety warnings for the BlueSecure Access Point 1800:
- Warning Definition
- Work During Lightning Activity Warning
Explosive Device Proximity Warning Antenna Installation Warning Power Source Warning Installation Instructions Warning Circuit Breaker (20A) Warning BlueSecure Access Point 1800 Installation Guide 31 Warning Definition Warning Waarschuwing Varoitus Attention IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. SAVE THESE INSTRUCTIONS BELANGRIJKE VEILIGHEIDSINSTRUCTIES Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van de standaard praktijken om ongelukken te voorkomen. Gebruik het nummer van de verklaring onderaan de waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd, wilt raadplegen. BEWAAR DEZE INSTRUCTIES TRKEIT TURVALLISUUSOHJEITA Tm varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin ksittelet laitteistoa, huomioi shkpiirien ksittelemiseen liittyvt riskit ja tutustu onnettomuuksien yleisiin ehkisytapoihin. Turvallisuusvaroitusten knnkset lytyvt laitteen mukana toimitettujen knnettyjen turvallisuusvaroitusten joukosta varoitusten lopussa nkyvien lausuntonumeroiden avulla. SILYT NM OHJEET IMPORTANTES INFORMATIONS DE SCURIT Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant entraner des blessures ou des dommages corporels. Avant de travailler sur un quipement, soyez conscient des dangers lis aux circuits lectriques et familiarisez-vous avec les procdures couramment utilises pour viter les accidents. Pour prendre connaissance des traductions des avertissements figurant dans les consignes de scurit traduites qui accompagnent cet appareil, rfrez-vous au numro de l'instruction situ la fin de chaque avertissement. CONSERVEZ CES INFORMATIONS Warnung WICHTIGE SICHERHEITSHINWEISE DiesesWarnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen fhren kann. Machen Sie sich vor der Arbeit mit Gerten mit den Gefahren elektrischer Schaltungen und den blichen Verfahren zur Vorbeugung vor Unfllen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen bersetzung in den bersetzten Sicherheitshinweisen, die zusammen mit diesem Gert ausgeliefert wurden. BEWAHREN SIE DIESE HINWEISE GUT AUF. 32 Safety Warnings for BlueSecure Access Point 1800 Avvertenza Advarsel Aviso Advertencia!
Varning!
IMPORTANTI ISTRUZIONI SULLA SICUREZZA Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti. Utilizzare il numero di istruzione presente alla fine di ciascuna avvertenza per individuare le traduzioni delle avvertenze riportate in questo documento. CONSERVARE QUESTE ISTRUZIONI VIKTIGE SIKKERHETSINSTRUKSJONER Dette advarselssymbolet betyr fare. Du er i en situasjon som kan fre til skade p person. Fr du begynner arbeide med noe av utstyret, m du vre oppmerksom p farene forbundet med elektriske kretser, og kjenne til standardprosedyrer for forhindre ulykker. Bruk nummeret i slutten av hver advarsel for finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne enheten. TA VARE P DISSE INSTRUKSJONENE INSTRUES IMPORTANTES DE SEGURANA Este smbolo de aviso significa perigo. Voc est em uma situao que poder ser causadora de leses corporais. Antes de iniciar a utilizao de qualquer equipamento, tenha conhecimento dos perigos envolvidos no manuseio de circuitos eltricos e familiarize-se com as prticas habituais de preveno de acidentes. Utilize o nmero da instruo fornecido ao final de cada aviso para localizar sua traduo nos avisos de segurana traduzidos que acompanham este dispositivo. GUARDE ESTAS INSTRUES INSTRUCCIONES IMPORTANTES DE SEGURIDAD Este smbolo de aviso indica peligro. Existe riesgo para su integridad fsica. Antes de manipular cualquier equipo, considere los riesgos de la corriente elctrica y familiarcese con los procedimientos estndar de prevencin de accidentes. Al final de cada advertencia encontrar el nmero que le ayudar a encontrar el texto traducido en el apartado de traducciones que acompaa a este dispositivo. GUARDE ESTAS INSTRUCCIONES VIKTIGA SKERHETSANVISNINGAR Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utfr arbete p ngon utrustning mste du vara medveten om farorna med elkretsar och knna till vanliga frfaranden fr att frebygga olyckor. Anvnd det nummer som finns i slutet av varje varning fr att hitta dess versttning i de versatta skerhetsvarningar som medfljer denna anordning. SPARA DESSA ANVISNINGAR BlueSecure Access Point 1800 Installation Guide 33 Aviso Advarsel INSTRUES IMPORTANTES DE SEGURANA Este smbolo de aviso significa perigo. Voc se encontra em uma situao em que h risco de leses corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos eltricos e familiarize-se com as prticas padro de preveno de acidentes. Use o nmero da declarao fornecido ao final de cada aviso para localizar sua traduo nos avisos de segurana traduzidos que acompanham o dispositivo. GUARDE ESTAS INSTRUES VIGTIGE SIKKERHEDSANVISNINGER Dette advarselssymbol betyder fare. Du befinder dig i en situation med risiko for legemesbeskadigelse. Fr du begynder arbejde p udstyr, skal du vre opmrksom p de involverede risici, der er ved elektriske kredslb, og du skal stte dig ind i standardprocedurer til undgelse af ulykker. Brug erklringsnummeret efter hver advarsel for at finde oversttelsen i de oversatte advarsler, der fulgte med denne enhed. GEM DISSE ANVISNINGER 34 Safety Warnings for BlueSecure Access Point 1800 Explosive Device Proximity Warning Do not operate your wireless network device near unshielded blasting caps or in an explosive environment unless the device has been modified to be especially qualified for such use. BlueSecure Access Point 1800 Installation Guide 35 Waarschuwing Gebruik dit draadloos netwerkapparaat alleen in de buurt van onbeschermde ontstekers of in een omgeving met explosieven indien het apparaat speciaal is aangepast om aan de eisen voor een dergelijk gebruik te voldoen. Varoitus l kyt johdotonta verkkolaitetta suojaamattomien rjytysnallien lheisyydess tai rjytysalueella, jos laitetta ei ole erityisesti muunnettu sopivaksi sellaiseen kyttn. Attention Ne jamais utiliser un quipement de rseau sans fil proximit d'un dtonateur non blind ou dans un lieu prsentant des risques d'explosion, sauf si l'quipement a t modifi cet effet Warnung Benutzen Sie Ihr drahtloses Netzwerkgert nicht in der Nhe ungeschtzter Sprengkapseln oder anderer explosiver Stoffe, es sei denn, Ihr Gert wurde eigens fr diesen Gebrauch modifiziert und bestimmt. Avvertenza Non utilizzare la periferica di rete senza fili in prossimit di un detonatore non protetto o di esplosivi a meno che la periferica non sia stata modificata a tale proposito. Advarsel Ikke bruk den trdlse nettverksenheten nrt inntil uisolerte fenghetter eller i et eksplosivt milj med mindre enheten er modifisert slik at den tler slik bruk. Aviso No opere o dispositivo de rede sem fios perto de cpsulas explosivas no protegidas ou num ambiente explosivo, a no ser que o dispositivo tenha sido modificado para se qualificar especialmente para essa utilizao. Advertencia! No utilizar un aparato de la red sin cable cerca de un detonador que no est protegido ni tampoco en un entorno explosivo a menos que el aparato haya sido modificado con ese fin. Varning! Anvnd inte den trdlsa ntverksenheten i nrheten av oskyddade tndhattar eller i en explosiv milj om inte enheten modifierats fr att kunna anvndas i sdana sammanhang. Antenna Installation Warning Warning In order to comply with FCC radio frequency (RF) exposure limits, antennas should be located at a minimum of 7.9 inches (20 cm) or more from the body of all persons. Waarschuwing Om te voldoen aan de FCC radiofrequentie (RF) blootstellingslimieten dienen antennes zich minstens 20 cm of meer van de lichamen van alle personen bevinden. Varoitus FCC:n antamien radiotaajuuksille altistumista koskevien rajoitusten mukaan antennien on sijaittava vhintn 20 cm:n pss kaikista henkilist. Attention Pour se conformer aux limites d'exposition la frquence radio prconises par la FCC (Federal Communications Commission), les antennes doivent se situer un minimum de 20 cm de toute personne. Warnung Um die in den FCC-Richtlinien festgelegten Expositionshchstgrenzen fr Radiofrequenzen (RF) nicht zu berschreiten, sollten Antennen mindestens 20 cm entfernt von Personen aufgestellt werden. 36 Safety Warnings for BlueSecure Access Point 1800 Avvertenza Per conformarsi ai limiti FCC di esposizione a radiofrequenza (RF), le antenne devono stare ad una distanza minima di 20 cm dal corpo di ogni persona. Advarsel I henhold til eksponeringsgrensene for radiofrekvenser (RF), skal antenner befinne seg p en avstand av minst 20 cm eller mer fra mennesker. Aviso Para estar de acordo com as normas FCC de limites de exposio para freqncia de rdio (RF), as antenas devem estar distantes no mnimo 20 cm (7,9 pol) do corpo de qualquer pessoa. Advertencia!
Para cumplir con los lmites de exposicin de radio frecuencia (RF) de la Comisin Federal de Comunicaciones (FCC) es preciso ubicar las antenas a un mnimo de 20 cm (7,9 pulgadas) o ms del cuerpo de las personas. Varning!
Fr att flja FCC-exponeringsgrnserna fr radiofrekvens (RF), br antenner placeras p minst 20 cm avstnd frn alla mnniskor. Power Source Warning Warning This product must be connected to a Power over Ethernet (PoE) IEEE 802.3af compliant power source or an IEC60950 compliant limited power source. Waarschuwing Dit product moet worden verbonden met een stroomvoorziening die compatibel is met PoE (Power over Ethernet) IEEE 802.3af of een beperkte stroomvoorziening die compatibel is met IEC60950. Varoitus Tm tuote on liitettv PoE (Power over Ethernet) IEEE 802.3af -
yhteensopivaan virtalhteeseen tai IEC60950-yhteensopivaan rajoitettuun virtalhteeseen. Attention Ce produit doit tre connect une source d'alimentation lectrique par cble Ethernet (PoE) conforme la norme IEEE 802.3af ou une source d'alimentation limite conforme la norme IEC60950. Warnung Dieses Produkt muss entweder an eine Stromquelle angeschlossen sein, die mit dem IEEE 802.3af-Standard Power over Ethernet (PoE) kompatibel ist oder an eine Stromquelle fr geringe Leistungen, die IEC60950-kompatibel ist. Avvertenza Questo prodotto deve essere connesso a una fonte di alimentazione di tipo PoE (Power over Ethernet) conforme a IEEE 802.3af o a una fonte di alimentazione conforme a IEC60950. Advarsel Dette produktet m vre koblet til en Power over Ethernet (PoE) IEEE 802.3af-kompatibel strmkilde eller en IEC60950-kompatibel begrenset strmkilde. Aviso Este produto tem de estar ligado a uma fonte de alimentao compatvel com a norma IEEE 802.3af, tambm conhecida pela sigla Power over Ethernet (PoE), ou a uma fonte de alimentao limitada compatvel com a norma IEC60950. Advertencia! Debe conectar este producto a una fuente de alimentacin sobre ethernet
(PoE) conforme con el estndar IEEE 802.3af, o a una fuente limitada conforme con el estndar IEC60950. Varning! Denna produkt mste vara ansluten till en PoE IEEE 802.3af-kompatibel strmklla eller en IEC60950-kompatibel begrnsad strmklla. BlueSecure Access Point 1800 Installation Guide 37 Work During Lightning Activity Warning Warning Do not work on the system or connect or disconnect cables during periods of lightning activity. Waarschuwing Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het systeem te werken of kabels aan te sluiten of te ontkoppelen. Varoitus l tyskentele jrjestelmn parissa lk yhdist tai irrota kaapeleita ukkosilmalla. Attention Ne pas travailler sur le systme ni brancher ou dbrancher les cbles pendant un orage. Warnung Arbeiten Sie nicht am System und schlieen Sie keine Kabel an bzw. trennen Sie keine ab, wennes gewittert. Avvertenza Non lavorare sul sistema o collegare oppure scollegare i cavi durante un temporale con fulmini. Advarsel Utfr aldri arbeid p systemet, eller koble kabler til eller fra systemet nr det tordner eller lyner. Aviso No trabalhe no sistema ou ligue e desligue cabos durante perodos de mau tempo (trovoada). Advertencia! No operar el sistema ni conectar o desconectar cables durante el transcurso de descargas elctricas en la atmsfera. Varning!
Vid ska skall du aldrig utfra arbete p systemet eller ansluta eller koppla loss kablar. 38 Safety Warnings for BlueSecure Access Point 1800 Installation Instruction Warning Warning Read the installation instructions before connecting the system to the power source. Waarschuwing Raadpleeg de installatie-instructies voordat u het systeem op de voedingsbron aansluit. Varoitus Lue asennusohjeet ennen jrjestelmn yhdistmist virtalhteeseen. Attention Avant de brancher le systme sur la source d'alimentation, consulter les directives d'installation. Warnung Vor dem Anschlieen des Systems an die Stromquelle die Installationsanweisungen lesen. Avvertenza Consultare le istruzioni di installazione prima di collegare il sistema all'alimentatore. Advarsel Les installasjonsinstruksjonene fr systemet kobles til strmkilden. Aviso Leia as instrues de instalao antes de ligar o sistema fonte de energia. Advertencia!
Lea las instrucciones de instalacin antes de conectar el sistema a la red de alimentacin. Varning!
Ls installationsanvisningarna innan du kopplar systemet till strmfrsrjningsenheten. Circuit Breaker (20A) Warning Warning This product relies on the buildings installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 20A. Waarschuwing Dit product is afhankelijk van de installatie van het gebouw voor beveiliging tegen kortsluiting (overstroom). Controleer of de beschermingsinrichting niet meer dan: 20A is. Varoitus Attention Tm tuote on riippuvainen rakennukseen asennetusta oikosulkusuojauksesta (ylivirtasuojauksesta). Varmista, ett suojalaitteen mitoitus ei ole yli: 20A. Pour ce qui est de la protection contre les courts-circuits (surtension), ce produit dpend de l'installation lectrique du local. Vrifiez que le courant nominal du dispositif de protection n'est pas suprieur : 20A. BlueSecure Access Point 1800 Installation Guide 39 Warnung Dieses Produkt ist darauf angewiesen, dass im Gebude ein Kurzschluss-
bzw. berstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 20A betrgt. Avvertenza Questo prodotto dipende dall'impianto dell'edificio per quanto riguarda la protezione contro cortocircuiti (sovracorrente). Assicurarsi che il dispositivo di protezione non abbia un rating superiore a: 20A. Advarsel Dette produktet er avhengig av bygningens installasjoner av kortslutnings
(overstrm)-beskyttelse. Pse at verneenheten ikke er merket hyere enn:
20A. Aviso Este produto depende das instalaes existentes para proteo contra curto-circuito (sobrecarga). Assegure-se de que o fusvel ou disjuntor no seja superior a: 20A. Advertencia!
Este equipo utiliza el sistema de proteccin contra cortocircuitos (o sobrecorrientes) del edificio. Asegrese de que el dispositivo de proteccin no sea superior a: 20A. Varning! Denna produkt r beroende av i byggnaden installerat kortslutningsskydd
(verstrmsskydd). Kontrollera att skyddsanordningen inte har hgre mrkvrde n: 20A. 40
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2008-10-27 | 5745 ~ 5805 | NII - Unlicensed National Information Infrastructure TX | Original Equipment |
2 | 5745 ~ 5805 | DTS - Digital Transmission System |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2008-10-27
|
||||
1 2 | Applicant's complete, legal business name |
Bluesocket, Incorporated
|
||||
1 2 | FCC Registration Number (FRN) |
0013804042
|
||||
1 2 | Physical Address |
901 Explorer Boulevard
|
||||
1 2 |
Huntsville, Alabama 35806-2807
|
|||||
1 2 |
United States
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
T******@TIMCOENGR.COM
|
||||
1 2 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 2 | Grantee Code |
TIH
|
||||
1 2 | Equipment Product Code |
BSAP1800N
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
J******** W********
|
||||
1 2 | Title |
Compliance Officer
|
||||
1 2 | Telephone Number |
256 9********
|
||||
1 2 | Fax Number |
256 9********
|
||||
1 2 |
j******@adtran.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | NII - Unlicensed National Information Infrastructure TX | ||||
1 2 | DTS - Digital Transmission System | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | BlueSecure Access Point 1800(N) | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Does not apply | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Power listed is the combined maximum conducted output power. Operations in the band 5.15-5.25GHz are restricted to indoor usage only. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Device is a WLAN operating in 3x3 Spatial Multiplexing/Cyclic Delay Diversity MIMO configurations as described in this filing. When operating in 802.11n, 40 MHz mode, the operating frequency segment is limited to 5190 to 5230 MHz and 5755 to 5797 MHz. | ||||
1 2 | Power listed is the maximum combined conducted output power as indicated in the filing. This device is equipped with specific antennas operating in a 3x3 MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. When operating in 802.11n - 40 MHz mode, the operating frequency segment is limited to 2422 to 2452 MHz and 5755 to 5795 MHz. | |||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
Compliance Worldwide, Inc.
|
||||
1 2 | Name |
L******** S******
|
||||
1 2 | Telephone Number |
603-8******** Extension:
|
||||
1 2 | Fax Number |
603-8********
|
||||
1 2 |
L******@cw-inc.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15E | CC MO | 5180 | 5230 | 0.0363 | |||||||||||||||||||||||||||||||||||
1 | 2 | 15E | CC MO | 5745 | 5805 | 0.131 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | CC MO | 2412 | 2462 | 0.356 | |||||||||||||||||||||||||||||||||||
2 | 2 | 15C | CC MO | 5745 | 5805 | 0.103 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC