all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User manual | Users Manual | 155.28 KiB | October 04 2019 | |||
1 |
|
Internal photos | Internal Photos | 398.43 KiB | October 04 2019 | |||
1 |
|
External photos | External Photos | 570.24 KiB | October 04 2019 | |||
1 |
|
Label and label location | ID Label/Location Info | 93.71 KiB | October 04 2019 | |||
1 | Block diagram | Block Diagram | April 10 2019 | confidential | ||||
1 |
|
Confidentiality request letter | Cover Letter(s) | 22.83 KiB | October 04 2019 | |||
1 |
|
Letter of declaration label location | Cover Letter(s) | 147.16 KiB | October 04 2019 | |||
1 |
|
Letter of declaration model difference | Cover Letter(s) | 103.03 KiB | October 04 2019 | |||
1 | Operation description | Operational Description | April 10 2019 | confidential | ||||
1 | Schematic | Schematics | April 10 2019 | confidential | ||||
1 |
|
Test Report | Test Report | 724.42 KiB | October 04 2019 | |||
1 |
|
Test setup photos | Test Setup Photos | 167.91 KiB | October 04 2019 |
1 | User manual | Users Manual | 155.28 KiB | October 04 2019 |
USER MANUAL Five button The car is locked after you pressLOCK button. The car is unlocked after you pressUNLOCK button. The Fuel tank cap is opened after you press this button Transmit Frequency 315MHz Modulation Type:
FSK The car begin to enter the panic state after you pressPANIC button. The trunk is opened after you pressTRUNK button. This button is used to SUV(Sport Utility Vehicle). FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
1 | Internal photos | Internal Photos | 398.43 KiB | October 04 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 1. INTERIOR PHOTOGRAPHS Fig. 1 Fig. 2 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 3 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA Fig. 3 Antenna Fig. 4 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 3 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA Fig. 5 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 3
1 | External photos | External Photos | 570.24 KiB | October 04 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 1. EXTERIOR PHOTOGRAPHS BAP#0102J Fig. 1 Fig. 2 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 5 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA Fig. 3 Fig. 4 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 5 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA Fig. 5 Fig. 6 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 5 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA BAP#0102V BAP#0102CV Fig. 7 Fig. 8 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 5 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA BAP#0102 BAP#0102SV Fig. 9 Fig. 10 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 5
1 | Label and label location | ID Label/Location Info | 93.71 KiB | October 04 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA LABEL AND LOCATION remote Model No.: BAP#0102 FCC ID: 2AQPB-BAP0102 Battery: 3V Size: L1.5cm*W1.0cm Label Location This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1
1 | Confidentiality request letter | Cover Letter(s) | 22.83 KiB | October 04 2019 |
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046
<2019-04-01>
TO WHOM IT MAY CONCERN Pursuant to Paragraphs 0.457 and 0.459 of the Commissions Rules (47 C.F.R.) and Section 552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products:
FCC ID 2AQPB-BAP0102 For the product stated above, we request that the following information be held confidential;
Model name BAP#0102 Short-Term Confidentiality Days Long-Term Short-Term Confidentiality Confidentiality Exhibits External Photos Internal Photos Block Diagram Schematics Test Setup Photos Users Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely,
(Signed) Name/Title: Adam J. Wolfe / Manager Company Name: Boost Auto Parts LLC Address: Boost Auto Parts 2948 Kirk Road.Suite 106, #324 Aurora Illinois 60502, United States Tel: (765) 831-2830 Fax: (765) 831-2830 E-Mail: 51513920@qq.com
1 | Letter of declaration label location | Cover Letter(s) | 147.16 KiB | October 04 2019 |
Boost Auto Parts 2948 Kirk Road.Suite 106, #324 Aurora Illinois 60502, United Boost Auto Parts LLC States Labeling Declaration Letter Date: April 8, 2019 FCC ID: 2AQPB-BAP0102 Model Number: BAP#0102J, BAP#0102CV, BAP#0102SV, BAP#0102, BAP#0102V Following the KDB 784748 D01General labeling and Notification, the information related to Labeling implementation for the remote, FCC ID: 2AQPB-BAP0102 Information FCC ID Number 15.19 Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment On Product On Product Packaging In Online User Guide Yes Yes No In Printed User Guide No No Yes No Yes No No No Yes Product Packaging Label is shown below:
FCC ID: 2AQPB-BAP0102 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, The product is packaged individually. Boost Auto Parts 2948 Kirk Road.Suite 106, #324 Aurora Illinois 60502, United Boost Auto Parts LLC States Should you have any questions or comments regarding this matter, please have my best attention. Sincerely,
(Signed) Name/Title: Adam J. Wolfe / Manager Company Name: Boost Auto Parts LLC Address: Boost Auto Parts 2948 Kirk Road.Suite 106, #324 Aurora Illinois 60502, United States Tel: (765) 831-2830 Fax: (765) 831-2830 E-Mail: 51513920@qq.com
1 | Letter of declaration model difference | Cover Letter(s) | 103.03 KiB | October 04 2019 |
Boost Auto Parts 2948 Kirk Road.Suite 106, #324 Aurora Illinois 60502, United Boost Auto Parts LLC States Product Similarity Declaration Date: April 8, 2019 FCC ID: 2AQPB-BAP0102 Model Number: BAP#0102J, BAP#0102CV, BAP#0102SV, BAP#0102, BAP#0102V To:
Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD To Whom It May Concern, We, Boost Auto Parts LLC hereby declare that our product (remote) Model Number:
BAP#0102J, BAP#0102CV, BAP#0102SV, BAP#0102, BAP#0102V board, Schematic, Hardware version, Software version, structure and internal photos are same, only color and appearance (without any metal) difference, named differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely,
(Signed) Name/Title: Adam J. Wolfe / Manager Company Name: Boost Auto Parts LLC Address: Boost Auto Parts 2948 Kirk Road.Suite 106, #324 Aurora Illinois 60502, United States Tel: (765) 831-2830 Fax: (765) 831-2830 E-Mail: 51513920@qq.com
1 | Test Report | Test Report | 724.42 KiB | October 04 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA FCC TEST REPORT For Boost Auto Parts LLC remote Test Model: BAP#0102J Additional Model: Please Refer to Page 6
: Boost Auto Parts LLC
:
Boost Auto Parts 2948 Kirk Road.Suite 106, #324 Aurora Illinois 60502 United States
: Shenzhen LCS Compliance Testing Laboratory Ltd.
:
1/F., Xingyuan Industrial Park, Tongda Road, Baoan Avenue, Baoan District, Shenzhen, Guangdong, China
:
(+86)755-82591330
:
(+86)755-82591332
: www.LCS-cert.com
: webmaster@LCS-cert.com
: March 07, 2019
: 1
: Prototype
: March 07, 2019 ~ March 14, 2019
: March 15, 2019 Prepared for Address Prepared by Address Tel Fax Web Mail Date of receipt of test sample Number of tested samples Serial number Date of Test Date of Report This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA FCC TEST REPORT FCC CFR 47 PART 15C (15.231) Report Reference No. ................. : LCS190221021AEA Date of Issue ................................... : March 15, 2019 Testing Laboratory Name ............. : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ........................................... : 1/F., Xingyuan Industrial Park, Tongda Road, Baoan Avenue, Testing Location/ Procedure ...........
:
Baoan District, Shenzhen, Guangdong, China Full application of Harmonised standards Partial application of Harmonised standards Other standard testing method Applicants Name .......................... : Boost Auto Parts LLC Address ........................................... :
Boost Auto Parts 2948 Kirk Road.Suite 106, #324 Aurora Illinois 60502 United States Test Specification Standard .......................................... : FCC CFR 47 PART 15 Subpart C Test Report Form No. .................... : LCSEMC-1.0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. ................. : remote Trade Mark ...................................... : N/A Test Model ...................................... : BAP#0102J Ratings ............................................ : DC 3V by battery Result ............................................ : Positive Compiled by:
Supervised by:
Approved by:
Ace Chai / File administrators Calvin Weng / Technique principal Gavin Liang/ Manager This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA FCC TEST REPORT Test Report No. :
LCS190221021AEA March 15, 2019 Date of issue Test Mode............................... EUT........................................ Applicant...............................
: BAP#0102J
: BAP#0102J
: Boost Auto Parts LLC Address..................................
:
Boost Auto Parts 2948 Kirk Road.Suite 106, #324 Aurora Illinois 60502 United States Telephone.............................. Fax......................................... Manufacturer........................
: /
: /
: Wuxi Keyoung Electronic Technology Co., Ltd 5-301, 5-301 Huaqing Creative Park, Huishan Economic Development Zone, Wuxi, Jiangsu Address..................................
:
Telephone............................... : /
Fax.........................................
: /
: /
Factory..................................
: /
Address................................... Telephone..............................
: /
: /
Fax......................................... Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA Revision History Revision 000 Issue Date March 15, 2019 Revisions Initial Issue Revised By Gavin Liang This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................................... 6 1.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................................ 6 1.2. OBJECTIVE .......................................................................................................................................................... 6 1.3. ENVIRONMENTAL CONDITIONS ........................................................................................................................... 6 1.4. HOST SYSTEM CONFIGURATION LIST AND DETAILS .......................................................................................... 7 1.5. EXTERNAL I/O PORT ........................................................................................................................................... 7 1.6. DESCRIPTION OF TEST FACILITY ........................................................................................................................ 7 1.7. STATEMENT OF THE MEASUREMENT UNCERTAINTY ......................................................................................... 7 2. TEST METHODOLOGY ......................................................................................................................................... 8 2.1. EUT CONFIGURATION ........................................................................................................................................ 8 2.2. EUT EXERCISE ................................................................................................................................................... 8 2.3. GENERAL TEST PROCEDURES ........................................................................................................................... 8 2.4. INSTRUMENT CALIBRATION ................................................................................................................................. 8 2.5. TEST MODE ......................................................................................................................................................... 8 3. SYSTEM TEST CONFIGURATION ...................................................................................................................... 9 3.1. JUSTIFICATION .................................................................................................................................................... 9 3.2. EUT EXERCISE SOFTWARE ................................................................................................................................ 9 3.3. SPECIAL ACCESSORIES ...................................................................................................................................... 9 3.4. BLOCK DIAGRAM/SCHEMATICS........................................................................................................................... 9 3.5. EQUIPMENT MODIFICATIONS .............................................................................................................................. 9 3.6. TEST SETUP ........................................................................................................................................................ 9 4. SUMMARY OF TEST RESULTS ........................................................................................................................ 10 5. TEST ITEMS AND RESULTS ............................................................................................................................. 11 5.1. TRANSMISSION CEASE TIME ............................................................................................................................. 11 5.2. TRANSMITTER FIELD STRENGTH OF EMISSIONS .............................................................................................. 13 5.3. AC POWER LINE CONDUCTED EMISSIONS (NOT APPLICABLE) ........................................................................ 22 5.4. 20DB BANDWIDTH EMISSIONS ......................................................................................................................... 23 5.5. DUTY CYCLE ...................................................................................................................................................... 24 5.6. ANTENNA REQUIREMENT .................................................................................................................................. 27 6. LIST OF MEASURING EQUIPMENTS .............................................................................................................. 28 7. TEST SETUP PHOTOGRAPHS OF EUT .......................................................................................................... 29 8. EXTERIOR PHOTOGRAPHS OF THE EUT ..................................................................................................... 29 9. INTERIOR PHOTOGRAPHS OF THE EUT ...................................................................................................... 29 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 1. GENERAL INFORMATION 1.1. Description of Device (EUT) EUT
:
remote Test Model Power Supply
: BAP#0102J
: DC 3V by battery Additional Model
: BAP#0102CV, BAP#0102SV, BAP#0102, BAP#0102V Model Declaration
: PCB board, structure and internal of these model(s) are the same, So no additional models were tested. Hardware Version
: N/A Software Version
: N/A Transmit Frequency
: 315MHz Number of Channels
: 1 Modulation Type
: ASK Antenna Description
: PCB Antenna, 5dBi (Max.) 1.2. Objective The primary objective of the manufacturer is compliance with Subpart C of Part 15 of FCC Certification is a procedure where the manufacturer or a contracted laboratory makes measurements and submits the test data and technical information to the FCC. The FCC issues a grant of equipment authorization upon successful completion of their review of the submitted documents. Once the equipment authorization has been obtained, the label indicating compliance must be attached to all identical units, which are subsequently manufactured. Maintenance of compliance is the responsibility of the manufacturer. Any modification of the product which may result in increased emissions should be checked to ensure compliance has been maintained (i.e., printed circuit board layout changes, different line filter, different power supply, harnessing or I/O cable changes, etc.). 1.3. Environmental Conditions During the measurement the environmental conditions were within the listed ranges:
- Temperature: 15-35C
- Humidity: 30-60 %
- Atmospheric pressure: 86-106kPa This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 6 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 1.4. Host System Configuration List and Details Manufacturer Description
--
--
Model
--
Serial Number Certificate
--
--
1.5. External I/O Port I/O Port Description
--
Quantity
--
Cable
--
1.6. Description of Test Facility FCC Registration Number is 254912. Industry Canada Registration Number is 9642A-1. ESMD Registration Number is ARCB0108. UL Registration Number is 100571-492. TUV SUD Registration Number is SCN1081. TUV RH Registration Number is UA 50296516-001 NVLAP Registration Code is 600167-0 The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR 16-1-4:2010 SVSWR requirement for radiated emission above 1GHz. 1.7. Statement of The Measurement Uncertainty ISO Guide 17025 requires that an estimate of the measurement uncertainties associated with the emissions test results be included in the report. The measurement uncertainties given below are based on a 95%
confidence level and were calculated in accordance with NAMAS document NIS 81. Test Item Frequency Range Radiation Uncertainty
:
9KHz~30MHz 30MHz~200MHz 200MHz~1000MHz Conduction Uncertainty :
:
Power disturbance 1GHz~26.5GHz 150kHz~30MHz 30MHz~300MHz Uncertainty 3.10dB 2.96dB 3.10dB 3.80dB 1.63dB 1.60dB Note
(1)
(1)
(1)
(1)
(1)
(1)
(1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 7 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 2. TEST METHODOLOGY All measurements contained in this report were conducted with ANSI C63.10: 2013, American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices. The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All radiated and conducted emissions measurement was performed at Shenzhen LCS Compliance Testing Laboratory Ltd. 2.1. EUT Configuration The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions requirement and operating in a manner that intends to maximize its emission characteristics in a continuous normal application. 2.2. EUT Exercise The EUT was operated in the normal operating mode. The TX frequency that was fixed which was for the purpose of the measurements. According to its specifications, the EUT must comply with the requirements of the Section 15.203, 15.205, 15.207, 15.209 and 15.231 under the FCC Rules Part 15 Subpart C and RSS-210. 2.3. General Test Procedures 2.3.1 Conducted Emissions (N/A) According to the requirements in Section 6.2 of ANSI C63.10: 2013, AC power-line conducted emissions shall be measured in the frequency range between 0.15 MHz and 30MHz using Quasi-peak and average detector modes. 2.3.2 Radiated Emissions The EUT is placed on a turn table and the turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find out the maximum emissions, exploratory radiated emission measurements were made according to the requirements in Section 6.3 of ANSI C63.10:
2013. 2.4. Instrument Calibration All test equipment is regularly checked to ensure that performance is maintained in accordance with the manufacturer's specifications. All antennas are calibrated at regular intervals with respect to tuned half-wave dipoles. An exhibit of this report contains the list of test equipment used and calibration information. 2.5. Test Mode The EUT has been tested under engineering mode. The field strength of radiation emission was measured in the following position: EUT stand-up position (Y axis), lie-down position (X, Z axis). The worst case of Y axis was reported. A new battery supplied DC 3V power to the EUT for testing. The EUT transmits signal as soon as it is powered on, and recorded the result in this report.
***Note: Using a temporary antenna connector for the EUT when conducted measurements are performed. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 8 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 3. SYSTEM TEST CONFIGURATION 3.1. Justification The system was configured for testing in a continuous transmit condition. Continuous transmitting. The EUT After the power is switched on, the hand is placed over the microwave module, and the Signal continuous transmission. 3.2. EUT Exercise Software N/A 3.3. Special Accessories N/A 3.4. Block Diagram/Schematics Please refer to the related document 3.5. Equipment Modifications Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT. 3.6. Test Setup Please refer to the test setup photo. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 9 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 4. SUMMARY OF TEST RESULTS FCC Rules 15.203 15.205 15.209 15.231 (b) 15.231 (c) 15.231 (a)(1) 15.231 15.207 Remark:
Applied Standard: FCC Part 15 Subpart C: 15.231 Description of Test Antenna Requirement Restricted Bands Of Operation Radiated Emission Limits, General Requirements. Field Strength Of Fundamental and Harmonics 20dB Bandwidth Transmission Cease Time Duty cycle Factor AC Conducted Emissions Result Compliant Compliant Compliant Compliant Compliant Compliant Compliant N/A*
N/A* - Not Applicable as the device was powered by DC battery. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 10 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 5. TEST ITEMS AND RESULTS 5.1. Transmission Cease Time 5.1.1. Limit According to 15.231 (a) A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released. 5.1.2. Test Procedure Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all installation combinations. The antenna was all opened. 5.1.3. Test Results Temperature Test Engineer 23.2 Wang Chuang Humidity 53.4%
Frequency Transmission cease Time Limit: not more than 5 seconds of being
(MHz) 315
(s) 0.504 released (s) 5 Conclusion PASS This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 11 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 12 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 5.2. Transmitter Field Strength of Emissions 5.2.1. Limit According to 15.231 (b): In addition to the provisions of 15.205, the field strength of emissions from intentional radiators operated under this section shall not exceed the following:
Fundamental frequency (MHz) Field strength of fundamental
(microvolts/meter) Field strength of spurious emissions (microvolts/meter) 40.66-40.70 70-130 130-174 174-260 260-470 Above 470 2,250 1,250 3,750 11,250 to 3,750 13,750 to 12,500 12,500 225 125 375 1125 to 375 1375 to 1,250 1,250 1Linear interpolations.
(1) The above field strength limits are specified at a distance of 3 meters. The tighter limits apply at the band edges.
(2) Intentional radiators operating under the provisions of this section shall demonstrate compliance with the limits on the field strength of emissions, as shown in the above table, based on the average value of the measured emissions. As an alternative, compliance with the limits in the above table may be based on the use of measurement instrumentation with a CISPR quasi-peak detector. The specific method of measurement employed shall be specified in the application for equipment authorization. If average emission measurements are employed, the provisions in 15.35 for averaging pulsed emissions and for limiting peak emissions apply. Further, compliance with the provisions of 15.205 shall be demonstrated using the measurement instrumentation specified in that section.
(3) The limits on the field strength of the spurious emissions in the above table are based on the fundamental frequency of the intentional radiator. Spurious emissions shall be attenuated to the average (or, alternatively, CISPR quasi-peak) limits shown in this table or to the general limits shown in 15.209, whichever limit permits a higher field strength. 15.205 (a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in any of the frequency bands listed below:
MHz MHz MHz 0.090-0.110
\1\ 0.495-0.505 2.1735-2.1905 4.125-4.128 4.17725-4.17775 4.20725-4.20775 6.215-6.218 6.26775-6.26825 6.31175-6.31225 8.291-8.294 8.362-8.366 8.37625-8.38675 8.41425-8.41475 12.29-12.293. 12.51975-12.52025 12.57675-12.57725 13.36-13.41 16.42-16.423 16.69475-16.69525 16.80425-16.80475 25.5-25.67 37.5-38.25 73-74.6 74.8-75.2 108-121.94 123-138 149.9-150.05 156.52475-156.52525 156.7-156.9 162.0125-167.17 167.72-173.2 240-285 322-335.4 399.9-410 608-614 960-1240 1300-1427 1435-1626.5 1645.5-1646.5 1660-1710 1718.8-1722.2 2200-2300 2310-2390 2483.5-2500 2690-2900 3260-3267 3332-3339 3345.8-3358 3600-4400
\1\ Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
\2\ Above 38.6 GHz 4.5-5.15 5.35-5.46 7.25-7.75 8.025-8.5 9.0-9.2 9.3-9.5 10.6-12.7 13.25-13.4 14.47-14.5 15.35-16.2 17.7-21.4 22.01-23.12 23.6-24.0 31.2-31.8 36.43-36.5
(\2\) This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 13 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA Frequencies
(MHz) 0.009~0.490 0.490~1.705 1.705~30.0 30~88 88~216 216~960 Above 960 Field Strength
(microvolts/meter) 2400/F(KHz) 24000/F(KHz) 30 100 150 200 500 Measurement Distance
(meters) 300 30 30 3 3 3 3 5.2.2. Measuring Instruments and Setting Please refer to equipment list in this report. The following table is the setting of spectrum analyzer and receiver. Setting Spectrum Parameter Auto Attenuation 1000 MHz Start Frequency 10th carrier harmonic Stop Frequency RB / VB (Emission in restricted band) 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average RB / VB (Emission in non-restricted band) 1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average Receiver Parameter Attenuation Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency Setting Auto 9kHz~150kHz / RB/VB 200Hz/1KHz for QP/AVG 150kHz~30MHz / RB/VB 9kHz/30KHz for QP/AVG 30MHz~1000MHz / RB/VB 120kHz/1MHz for QP This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 14 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 5.2.3. Test Procedures 1) Sequence of testing 9 kHz to 30 MHz Setup:
--- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer.
--- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
--- If the EUT is a floor standing device, it is placed on the ground.
--- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
--- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
--- The measurement distance is 3 meter.
--- The EUT was set into operation. Premeasurement:
--- The turntable rotates from 0 to 315 using 45 steps.
--- The antenna height is 1.5 meter.
--- At each turntable position the analyzer sweeps with peak detection to find the maximum of all emissions Final measurement:
--- Identified emissions during the premeasurement the software maximizes by rotating the turntable position
(0 to 360) and by rotating the elevation axes (0 to 360).
--- The final measurement will be done in the position (turntable and elevation) causing the highest emissions with QPK detector.
--- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 15 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 2) Sequence of testing 30 MHz to 1 GHz Setup:
--- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer.
--- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane.
--- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
--- Auxiliary equipment and cables were positioned to simulate normal operation conditions
--- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
--- The measurement distance is 3 meter.
--- The EUT was set into operation. Premeasurement:
--- The turntable rotates from 0 to 315 using 45 steps.
--- The antenna is polarized vertical and horizontal.
--- The antenna height changes from 1 to 3 meter.
--- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to find the maximum of all emissions. Final measurement:
--- The final measurement will be performed with minimum the six highest peaks.
--- According to the maximum antenna and turntable positions of premeasurement the software maximize the peaks by changing turntable position ( 45) and antenna movement between 1 and 4 meter.
--- The final measurement will be done with QP detector with an EMI receiver.
--- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 16 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 3) Sequence of testing 1 GHz to 18 GHz Setup:
--- The equipment was set up to simulate a typical usage like described in the user manual or described by manufacturer.
--- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
--- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
--- Auxiliary equipment and cables were positioned to simulate normal operation conditions
--- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
--- The measurement distance is 3 meter.
--- The EUT was set into operation. Premeasurement:
--- The turntable rotates from 0 to 315 using 45 steps.
--- The antenna is polarized vertical and horizontal.
--- The antenna height is 1.5 meter.
--- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the maximum of all emissions. Final measurement:
--- The final measurement will be performed with minimum the six highest peaks.
--- According to the maximum found antenna polarization and turntable position of the premeasurement the software maximizes the peaks by rotating the turntable position (0 to 360). This measurement is repeated for different EUT-table positions (0 to 150 in 30-steps). This procedure is repeated for both antenna polarizations.
--- The final measurement will be done in the position (turntable, EUT-table and antenna polarization) causing the highest emissions with Peak and RMS detector.
--- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the premeasurement with marked maximum final measurements and the limit will be stored. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 17 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 5.2.4. Test Setup Layout This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 18 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 5.2.5. EUT Operation during Test The EUT was programmed to be in continuously transmitting mode. 5.2.6. Results of Radiated Emissions (9 KHz~30 MHz) The low frequency, which started from 9 KHz to 30 MHz, was pre-scan and the result was 20dB lower than the limit line per 15.31(o) was not reported. Note: Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
Limit line = specific limits (dBuV) + distance extrapolation factor. 5.2.7. Results of Radiated Emissions (30MHz~1GHz) 23.8 Tx Wang Chuang Humidity Pol 53.3%
Horizontal Temperature Test Engineer Test Mode Horizontal Frequency
(MHz) 315.48 Peak Level
(dBV/m) 76.50 AV Factor(dBV/m)
(see Section 5.4)
-14.31 Fundamental and Harmonics Average Result Limit(dBV/m) Average Level
(dBV/m) 75.05
(average) 82.36 Margin(dB) Conclusion
-7.31 PASS This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 19 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA Vertical Temperature Test Engineer Wang Chuang 23.8 Test Mode Tx Humidity Pol 53.3%
Vertical Fundamental and Harmonics Average Result Average Level Limit(dBV/m) AV Factor(dBV/m)
(see Section 5.4)
(dBV/m)
(average) Margin(dB) Conclusion
-14.31 51.93 82.36
-30.43 PASS Frequency
(MHz) 315.48 Peak Level
(dBV/m) 66.24 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 20 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 5.2.8. Results of Radiated Emissions (1-5GHz) Temperature Test Engineer 24.1 Wang Chuang Humidity Test Mode 52.3%
Tx Frequency
(MHz) 1260.05 1575.74 1260.21 1575.60 Level (dBuV/m) Peak Value Limit Line (dBuV/m) 49.07 45.15 41.41 41.46 74.00 74.00 74.00 74.00 Margin (dB)
-24.93
-28.85
-32.59
-32.54 Polarization Horizontal Horizontal Vertical Vertical Frequency
(MHz) 1260.23 1574.94 1260.41 1575.75 Level
(dBuV/m) 49.07 45.18 41.46 41.45 Duty cycle factor
-14.31
-14.31
-14.31
-14.31 Average Value:
Average value
(dBuV/m) 34.76 30.87 27.15 27.14 Limit Line
(dBuV/m) Margin (dB) Polarization Horizontal 54.00 Horizontal 54.00 Vertical 54.00 54.00 Vertical
-19.24
-23.13
-26.85
-26.86 Remark:
1. Measuring frequencies from 9 KHz~10th harmonic (ex. 5GHz), No emission found between lowest internal used/generated frequency to 30MHz. 2. Radiated emissions measured in frequency range from 9 KHz~10th harmonic (ex. 5GHz) were made with an instrument using Peak detector mode. 3. Average values = Peak values + DC factor = Peak values 14.31 3. Data of measurement within this frequency range shown --- in the table above means the reading of emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be measured. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 21 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 5.3. AC Power line conducted emissions (Not Applicable) 5.3.1 Standard Applicable According to 15.207 (a): For an intentional radiator which is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at specific frequency range is listed as follows:
Limits (dBV) Quasi-peak 66 to 56 56 60
* Decreasing linearly with the logarithm of the frequency Frequency Range
(MHz) 0.15 to 0.50 0.50 to 5 5 to 30 5.3.2 Block Diagram of Test Setup Average 56 to 46 46 50 5.3.3 Test Results Not Applicable!!!!
The device was powered by DC battery. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 22 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 5.4. 20dB Bandwidth Emissions 5.4.1. Limit The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices operating above 70 MHz and below 900 MHz. Bandwidth is determined at the points 20 dB down from the modulated carrier. 5.4.2. Test Procedure With the EUTs antenna attached, the EUTs 20dB Bandwidth power was received by the test antenna which was connected to the spectrum analyzer with the START and STOP frequencies set to the EUTs operation band. 5.4.3. Test Data 23.2 Wang Chuang Temperature Test Engineer Transmit Frequency
(MHz) 315 Maximum allowed bandwidth:
RBW:
VBW:
Humidity Test Mode 53.4%
TX Limit
(kHz) 787.50 20dB Bandwidth
(kHz) 56.38 0.25% of the centre operating frequency 0.5% of the centre operating frequency 10kHz 30kHz other kHz other kHz 100kHz 300kHz Result PASS This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 23 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 5.5. Duty cycle 5.5.1. Limit No dedicated limit specified in the Rules. 5.5.2. Test Procedure 1. Place the EUT on the table and set it in transmitting mode. 2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the spectrum analyser. 3. Set centre frequency of spectrum analyser = operating frequency. 4. Set the spectrum analyser as RBW=100 KHz, VBW=100 KHz, Span=0Hz, Adjust Sweep=100ms to obtain the worst-case pulse on time 5. Repeat above procedures until all frequency measured was complete. 5.5.3. Test Data Ton = 0.11*1+0.44*25+0.22*37=19.25 (ms) Tp = 100 (ms) The duty cycle = 19.25/100=19.25%
Average Correction Factory = 20*log (Ton/Tp) =20*log (0.1925) = -14.31dB Note: The signal bandwidth (2/PW=2/ (0.42) = 4.76 KHz) was measured and less than 100 kHz RBW so PDCF factor is not required to correct the fundamental signal peak result. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 24 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 25 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 26 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 5.6. Antenna Requirement 5.6.1. Standard Applicable According to antenna requirement of 15.203. An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this Section. The manufacturer may design the unit so that a broken antenna can be re-placed by the user, but the use of a standard antenna jack or electrical connector is prohibited. This requirement does not apply to carrier current devices or to devices operated under the provisions of Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further, this requirement does not apply to intentional radiators that must be professionally installed, such as perimeter protection systems and some field disturbance sensors, or to other intentional radiators which, in accordance with Section 15.31(d), must be measured at the installation site. However, the installer shall be responsible for ensuring that the proper antenna is employed so that the limits in this Part are not exceeded. 5.6.2. Antenna Connected Construction 5.6.2.1. Standard Applicable According to 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. 5.6.2.2. Antenna Connector Construction The gains of antenna used for transmitting is 5.0 dBi, and the antenna is a PCB Antenna connect to PCB board and no consideration of replacement. Please see EUT photo for details. 5.6.2.3. Results: Compliance. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 27 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 6. LIST OF MEASURING EQUIPMENTS Item Equipment Manufacturer 1 2 3 4 5 6 7 8 9 10 11 12 13 14 MXA Signal Analyzer DC Power Supply Temperature & Humidity Chamber EMI Test Software 3m Semi Anechoic Chamber Positioning Controller Active Loop Antenna By-log Antenna Horn Antenna EMI Test Receiver RS SPECTRUM ANALYZER AMPLIFIER RF Cable-R03m RF Cable-HIGH Agilent Agilent GUANGZHOU GOGNWEN AUDIX SIDT FRANKONIA MF Model No. N9020A E3642A GDS-100 E3 SAC-3M MF-7082 SCHWARZBECK SCHWARZBECK SCHWARZBECK FMZB 1519B VULB9163 BBHA 9120D R&S R&S QuieTek Jye Bao SUHNER ESR 7 FSP40 QTK RG142 SUCOFLEX 106 Serial No. MY49100060 N/A 70932
/
Cal Date 2018-11-15 2018-11-15 Due Date 2019-11-14 2019-11-14 2018-10-10 2019-10-09
/
/
03CH03-HY 2018-06-16 2019-06-15
/
00005 9163-470 9120D-1925 101181 100503 2018-06-16 2018-07-26 2018-07-26 2018-07-02 2018-06-16 2019-06-15 2019-07-25 2019-07-25 2019-07-01 2019-06-15 2018-11-15 2019-11-14 CHM/0809065 CB021 2018-11-15 2018-06-16 2019-11-14 2019-06-15 03CH03-HY 2018-06-16 2019-06-15 Note: All equipment is calibrated through GUANGZHOU LISAI CALIBRATION AND TEST CO.,LTD. This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 28 of 29 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 7. TEST SETUP PHOTOGRAPHS OF EUT Please refer to separated files for Test Setup Photos of the EUT. 8. EXTERIOR PHOTOGRAPHS OF THE EUT Please refer to separated files for External Photos of the EUT. 9. INTERIOR PHOTOGRAPHS OF THE EUT Please refer to separated files for Internal Photos of the EUT.
----------------THE END OF REPORT---------------
This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 29 of 29
1 | Test setup photos | Test Setup Photos | 167.91 KiB | October 04 2019 |
SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AQPB-BAP0102 Report No.:LCS190221021AEA 1. TEST SETUP PHOTOGRAPHS 1.1. Photo of Radiated Emissions Measurement Fig. 1 Fig. 2 _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-04-10 | 315 ~ 315 | DSC - Part 15 Security/Remote Control Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-04-10
|
||||
1 | Applicant's complete, legal business name |
Boost Auto Parts LLC
|
||||
1 | FCC Registration Number (FRN) |
0027717719
|
||||
1 | Physical Address |
Boost Auto Parts 2948 Kirk Road.Suite 106, #324
|
||||
1 |
Aurora, IL
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@cetecom.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AQPB
|
||||
1 | Equipment Product Code |
BAP0102
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
A**** J****
|
||||
1 | Title |
Purchasing Manager
|
||||
1 | Telephone Number |
630 6********
|
||||
1 | Fax Number |
630 6********
|
||||
1 |
p******@boostautoparts.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSC - Part 15 Security/Remote Control Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | remote | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Shenzhen LCS Compliance Testing Laboratory Ltd.
|
||||
1 | Name |
G****** L******
|
||||
1 | Telephone Number |
0755-********
|
||||
1 | Fax Number |
0755-********
|
||||
1 |
g******@lcs-cert.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15.231 | 315.00000000 | 315.00000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC