Description:
InstallingaBudderflyadaptertransformsyourbuildingsexistingwiringintotheBudderflyOpenNetworkandallowsthe adaptertomonitorenergyconsumptionandcommunicatethedatatoafacilitycontroller. Budderflyadaptorsusetheexistingpowerlineforcommunicationandthusrequirenorewiring. UsingourBudderflysoftware,youcanvisualizeconsumptiondataandmanageeachindividualadapter. TheBudderflyDualBandOutletisacomponentofBudderflysystemanddesignedtoworkwithallotherBudderflydevices. ItisaplugandplayreplacementforyourexistingOutlet.Onceinstalled,TheBudderflyoutletsalsoactasrepeatersto extendtherangeofthenetworkandincreaseefficiency. PartNoR0710021 WARNINGELECTRICALSHOCKHAZARD TheBudderflyDualBandOutletisintendedforinstallationinaccordancewiththe NationalElectricCodeandlocalregulationsintheUnitedStates. Ifyouarenotknowledgeableorcomfortablewithelectricalcircuitry,youshouldhavea qualifiedelectricianinstalltheBudderflyDualBandOutletforyou. Warning InstalltheBudderflyDualBandOutletsindooronly. NeverusetheBudderlyOutletstopowermedicaland/orlifesupportequipment. TheequipmentpluggedintothisBudderflyDualBandOutletmustnotexceed 2400Wat120VAC. Installation:
TheBudderflyDualBandOutletmaybeusedinnewinstallationsortoreplaceanexistingOutlet.Thewiringschematicwillbeasperbelow:
1. Atthecircuitbreakerorfusepanel,disconnectthepowerforallofthecircuits intheswitchjunctionbox. 2. DoubleCheckthatthepowerisOFFtotheOutletbytryingtoturnona deviceconnectedtotheplugbeforecontinuing. 3. Removethewallplatefromtheplugyouarereplacing.Then,unscrewthe outletitselfandpullitoutfromthejunctionbox. 4. Disconnectthewiresfromtheoutletyouarereplacing. 5. FollowtheWiringinformationprovidedbelowandconnectthewiresas follows:
ConnecttheGROUNDwire(usuallyBareCopperorGreen)totheGroundwire ofBudderflyDualBandOutlet(Yellow&Green). ConnecttheLINEwire(usuallyBlack)thatcomesfromtheelectricalservice paneltotheHOTwireofBudderflyDualBandOutlet(Black). ConnecttheNEUTRALwire(usuallyWhite)totheNeutralwireofBudderfly DualBandOutlet(White). 6. Afteryouhaveconnectedallofthewires,ensurethatallofthewire connectorsarefirmlyattachedandthatthereisnoexposedcopperexceptfor theGROUNDwire. 7. GentlyplaceBudderflyDualBandOutletintothejunctionbox.Then,screw theOutletintoplace. 8. Reinstallthewallplate 9. EnablepowertotheOutletfromthecircuitbreakerorfusepanel 10. AddthedeviceaddresstotheBudderflysoftware. WARNING:Ifyouarenotsureaboutanypartoftheaboveinstructions,consulta qualifiedelectrician. WARNINGELECTRICALSHOCKHAZARD TurnOFFthepowertothebranchcircuitfortheOutletatthe servicepanel. AllwiringconnectionsmustbemadewiththePOWEROFFto avoidpersonalinjuryand/ordamagetotheOutlet. WiringInformation Important:BudderflyOutletisratedforandintendedtoonly beusedwithcopperwire. Use12AWGorlargerwiressuitablefor80o. Remove3/4"(1.9cm)ofinsulationfromeachwire. Connectasfollows:Twiststrandsofeachendtightlytogether.Hold bareendsofwirestogetherandpushfirmlyintowireNut.ScrewNut clockwisemakingsurethatnobareconductorshowsbelowthe connector Features:
DeviceGrouping:
Abilitytocreateagroupofdevices Abilitytomonitorpowerconsumption LEDindicatortoshowthestateoftheOutlet UsingtheBudderflysoftware,itispossibletocreateaGroupof Outlets. Powerconsumption:
TheBudderflyDualBandOutletswillmeasurethecurrent,thevoltageandthe power consumed by the connected load, and will store the minimum, maximumandaveragedataforthepast7days. The data can be accessed at any time thru the Budderflysoftware. The user cangeneratereports,monitortheconsumptionorcheckexpenses. LEDIndicators:
TheBudderflyOutletsareequippedwith1biColorLEDthatwillindicatethe stateofthedevice. LEDisOff:TheBudderflyOutletisnotpowered. LEDisRed:TheBudderflyOutletisOnandnotmemberofagroup. LEDisGreen:TheBudderflyOutletisOnandismemberofagroup. Reset:
Ifthedevicestopsresponding,itcanberestartedbypushingtheResetButton. Anonmetallicpinshouldbeusedtopushtheresetbutton. Noneofthestoredparametersareaffected. WARNINGELECTRICALSHOCKHAZARD Neveruseametallicpintopresstheresetbutton. Specifications:
Power:120VAC/60Hz MaximumLoads:2400W,20A(max),1HP. OperatingTemperature:10oCto+40oC Certification:ULCertificationisinprogress Forindooruseonly Specificationssubjecttochangewithoutnoticeduetocontinuingproduct improvement. Communication:
The Budderfly Dual Band Outlets use the power line and radio frequency to communicatewiththeFacilityController. Theoutletscanreplytothefollowingcommands:
Join/DisjoingroupX:TheoutletwillJoin/DisjointhegroupX.Each outletcanbeamemberofseveralgroupsatthesametime. Direct RTC synchronization: The outlet can receive a command to synchronizeitsRealTimeClock the outlet receives a Get Get Actual Measurement: When Measurement command, it will send back to the facility controller a stringofdatathatcontains:
TheCurrentinAmpereA. ThePowerinWattW. ATimestamp. Get Stored Measurement: The outlet will send back to the Facility Controllerthestoredelectricalmeasurements. Direct Reset Commands: The outlet can receive 3 types of reset commands:
HardReset:Thiscommandwillrestartthedevicewithout affectinganystoredparameter. DataReset:Thiscommandwilleraseallthemeasurement andRTCdatastoredinthenonvolatilememory. GroupReset:Thiscommandwillremovethedevicefrom allthejoinedgroups. Group Reset Commands: The above reset commands can be directedtoagroupofdevicesinsteadofjustonedevice. Warranty:
Budderfly LLC warrants to the original consumer purchaser and not for the benefitofanyoneelsethatthisproductatthetimeofitssalebyBudderflyisfree of defects in material and workmanship under normal and proper use for a periodofthree(3)yearsfromdateofdeliverytoyou.Budderflysonlyobligation istocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuch three year period the product is returned prepaid via Budderflys Returned MaterialsAuthorization(RMA)processtoBudderflyLLC,Att:QualityAssurance Department, 2 Trap Falls Road, Suite 507, Shelton, CT 06484. In no case is producttobereturnedwithoutfirstobtaininganRMA. Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalof this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no otherorimpliedwarrantiesofanykind,includingmerchantabilityandfitness foraparticularpurpose,butifanyimpliedwarrantyisrequiredbytheapplicable jurisdiction, the duration of any such implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to three years. Budderfly is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. Budderflys liability on any claim for damages arising out of in connection with the manufacture, sales, installation delivery, or use of the product shall never exceed the purchase price of the product. The remedies providedhereinaretheexclusiveremediesunderthiswarranty,whetherbased oncontract,tortorotherwise. Changesormodificationsnotexpresslyapprovedbytheparty responsibleforcompliancecouldvoidtheusersauthoritytooperatethisequipment WARNING FCCComplianceStatement ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:
(1) Thisdevicemaynotcauseharmfulinterferenceand
(2) Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaclassBdigitaldevice,pursuanttopart15oftheFCCRules.Theselimits aredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcan radiateradiofrequencyenergyandifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradio communications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmful interferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotryto correcttheinterferencebyoneormoreofthefollowingmeasures:
Reorientorrelocatethereceivingantenna. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected. Theuseriscautionedthatchangesandmodificationsmadetotheequipmentwithouttheapprovalofmanufacturercouldvoidtheuser'sauthorityto operatethisequipment. FCCID:QCVR0710021 MadeinChina