User manual NO SWIP 41908 NO SWIP Manual 2 NO SWIP Manual Introduction NO SWIP GENERAL FEATURES NO SWIP (Ref. 41908)
- NO SWIP high-end biometric reader with capacitive sensor.
- Display with events and time.
- High resolution 508 dpi capacitive fingerprint sensor.
- Maximum security proximity for 13.56 MHz contactless MIFARE Plus, MIFARE DESFire EV1, MIFARE Classic and MIFARE Ultralight cards.
- Identifies fingerprint in less than 0.5 seconds when operating at 1:1, less than 1s at 1:20, and less than 1.5s at 1:100.
- Capacity for up to 100 fingerprints.
- Integrated door controller with digital output supplied for 24VDC / 250mA maximum locks. reader
- Wear-resistant surface finish with antibacterial treatment.
- Input for magnetic signal or door status sensor.
- Surface mounted for indoor use. REGULATIONS ISO/IEC 14443 A and B. AES128 NIST FIPS PUB 197 MIFARE Plus EAL4+ Common Criteria certification. NFC MIFARE emulation compliant. EN 60950-1 2001 and A1: 2004. EN 300 330-2 v1.3.1. 3 NO SWIP Manual NO SWIP Technical Specifications TECHNICAL SPECIFICATIONS NO SWIP:
INPUT VOLTAGE MAXIMUM POWER READING DISTANCE FINGERPRINT SENSOR TYPE Capacitive sensor SENSOR RESOLUTION MAX. NO. FINGERPRINTS 24VDC (11 - 28 VDC) 2 W without lock - 8 W lock activated 3 - 5 cm COMMUNICATIONS INPUTS OUTPUTS ILLUMINATION AUDIO MATERIALS INSTALLATION OPERATING TEMPERATURE DIMENSIONS 508 dpi 100 Fingerprints BYBUS RS-485 By Protocol: BYBUS high security communications. 1 Door sensor input 1 lock control output with 24 VDC power supply (250 mA maximum) Automatically regulated according to environmental lighting conditions. Colours according to status:
- Red/White: Terminal offline.
- Degraded Red/Pink: Terminal in card enrolment mode.
- Flashing blue: Terminal in firmware update mode.
- Blue: Normal security level.
- Purple: High security level.
- Light pink: Very high security level.
- Flashing yellow: Connected but not configured.
- Green: Access granted or Unrestricted.
- Red: Access denied or Door blocked.
- White: Card or fingerprint identification operation.
- Flashing white: Fingerprint enrolment.
- Green/Yellow: Door in emergency mode. Differentiated sound indicators for granted and denied access with two volume levels. Manufactured in high-quality, wear-resistant polycarbonate with antibacterial treatment. Surface mounted
-10 C to 50 C 130 x 50 x 36 mm (height x width x depth) 4 Introduction NO SWIP Manual NO SWIP TYPE OF WIRING AND WIRING DISTANCE:
The NO SWIP incorporates a male overhead connector. NO SWIP is supplied with a 3.5 metre piped cable with 4 wires (2 twisted pairs) and a female connector at one end to correctly connect it. The other end of the piped cable is connected to a single door controller or to the corresponding Wili following the simple colour coding. Naranja N/B Verde V/B
+
-
A B S U B Y B 3.5 metres of cable NO SWIP The wiring distance from the reader and the single door controller or Wili should not ex-
ceed 25 metres in length under any circumstances. WIRING SPECIFICATIONS:
The built-in piped cable used to connect the reader has the following technical characteristics:
- Gauge: 0.22 mm
- Arrangement: 2 twisted pairs
- Resistance: <2 Ohms
- Capacitance, core to earth: < 160pF/m
- Capacitance, core to core: < 100pF/m DISTANCE BETWEEN READERS:
A minimum distance of 12 cm must be maintained if installations are made with doors with 2 input/
output readers or with 2 readers that are very close together. 5 Introduction NO SWIP Manual Wall mounting
- TERMINAL MOUNTING:
1) Anchor the base piece to the wall using the screws and wall plugs provided. Make an opening for the cable. 2) Pass the reader connection cable through the hole in the base piece. X X X X The head of the figure in the drawing should be pointing upwards. Recommended height for installation: 1.2 - 1.5 m. 3) Place the reader by inclining it at an angle of about 45 C for the tabs on the base to hook together. 4) Screw the lower part using an allen key to secure it. 6 Installation NO SWIP Manual connections NO SWIP readers can be directly connected to two types of devices depending on the architecture of the installation:
- Connection to a Wili.
- Connection to a single door controller. The connection to be made for both types of devices is exactly the same. The colour code must be followed. For more detailed information, consult the equipment manuals referenced earlier. GND (0V)
+24 VDC RS-485 A RS-485 B Wire mesh READER WIRING:
COLOUR Orange Orange/White Green Green/White SIGNAL
+ 24VDC 0V / GND RS-485-A RS-485-B S U B Y B Install and connect the reader before powering the system. NO readers use the 24 VDC input voltage corresponding to the controller equipment to which they are connected, the power sources of which are rigorously prepared for such purpose. These signals must be perfectly isolated in order to prevent damaging the equipment or installation. 7 Installation Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. MT:16442 Version: 05 June 2018