. y t n a r r a W e m i t e f i L d e t i i m L o t r e f e R
. e t i m i i l e v e i t n a r a g e d s n o i t i d n o c r i o V
FR EN GALEOR Clavier cod Radio rtro-clair Illuminated RF keypad Range: Digicode /
Gamme: Digicode Group Products INSTALLATION MANUAL MANUEL DINSTALLATION FRANCAIS ENGLISH FR 77 MANUEL DINSTALLATION GALEOR Clavier cod radio rtro-clair Merci pour lachat de ce produit et pour la confiance que vous accordez notre entreprise. 1] PRESENTATION DU PRODUIT Clavier Radio sans fil. Alliage daluminium. Rtro-clair. Frquence : 433,92 Mhz. 2 canaux (touche A et B). Compatible avec les rcepteurs Erone. Faible encombrement. Pose en applique. Montage avec vis Torx. Partiellement rsin. 22 codes daccs 4 ou 5 termes. 1 code Matre 5 termes. Signalisation lumineuse et sonore. Modulation : AM/ASK. Encodage : Code tournant Keeloq. Alimentation : pile lithium 3,6V - LS14500*. Consommation :
- 28 mA en transmission,
- 0,8 uA en veille. 2] RAPPELS ET RECOMMANDATIONS Montage Afin doptimiser la fixation du GALEOR et de prvenir les tentatives darrachage, privilgiez les surfaces planes. 3] LMENTS FOURNIS HAUTE RESISTANCE AU VANDALISME 7 2 Test vibrations DEEE Test brouillard salin IP64 Certification CE
-25C +70C 2 1 1 FCC ID : PWN1002000029 The device complies with part 15 of the FCC Rules. Operation is subjected to the following 2 conditions:
(1) this device may not cause harmful interference and
(2) this device must accept any interference received, including interference that may cause undesired operation Composition des codes Par soucis de scurit, veillez modifier le code matre usine par celui de votre choix. Lors du changement du code matre usine et de la cration des codes utilisateurs, vitez les codes trop simples
(ex: les suites 3 4 5 6 7). Vis Torx tte fraise
(M4x10) Cl mle coude pour vis Torx
(T20) Cache vis plastique Vis tte fraise
(M4x30) Cheville plastique GALEOR 1 1 1 2 2 2 cdvigroup.com Pile 1 Joint dtanchit 1
* Fournie. Certification FCC CFR 47part 15 compliance MANUEL DINSTALLATION GALEOR Clavier cod radio rtro-clair 4] MONTAGE Percez les 2 trous de fixation (fort 5 mm et profondeur minimum. = 35 mm). Positionnez les 2 chevilles plastiques dans les trous. Collez le joint dtanchit sur la face arrire du socle du GALEOR (Important). Fixez le fond du GALEOR sur le support de votre choix, laide des vis ttes fraises. FR Enlevez la languette de protection de la pile et fixez le GALEOR son support par le haut avec le crochet suprieur. Bloquez le GALEOR sur son support par lintermdiaire de la vis TORX et de son outil spcifique (cl mle coude). Pour finaliser le montage de ce produit, placez le cache-vis. 5] TABLEAU UTILISATEURS Canal Canal Util.* A B Code Nom/Prnom Util.* A B Code Nom/Prnom 01 02 03 04 05 06 07 08 09 10 11
* Utilisateurs 12 13 14 15 16 17 18 19 20 21 22 cdvigroup.com 3 MANUEL DINSTALLATION GALEOR Clavier cod radio rtro-clair 6] PROGRAMMATION FR LES VALEURS DU GALEOR SONT PAR DFAUT:
- Sans codes.
- Buzzer activ
- Temporisation clairage : 3 s.
- Temporisation scurit mission radio : 25 secondes.
- Code matre usine : 1 2 3 4 5.
- Temporisation scurit programmation : 10 secondes.
- Choix des canaux :
Canal 1 = A, Canal 2 = B. SIGNAUx SONORES :
1 bip : En tension (Insertion de la pile) 1 long bip :
- Arrive dans le menu,
- Validation dun choix de programme,
- Sortie du menu. 2 bips : Entre dans le menu de retour la configuration usine. 3 bips : Confirmation du retour la configuration usine A+1 4 bips :
- Confirme le retour la configuration usine B+3,
- Erreur de canal,
- Erreur de code (Ex : Un code dj mmoris). TERMES UTILISS ET CODES DOUVERTURE:
- Toutes les touches du clavier sont autorises pour composer les codes, excepts les touches A et B.
- Les codes douverture de porte peuvent tre composs de 4 ou 5 termes.
- Le code matre doit tre compos de 5 termes
- Le code matre ne peut pas tre utilis comme code douverture. 7] DMARRAGE Le clavier est livr sans rglage du nombre de chiffres du code utilisateur. A linsertion de la batterie, les 12 touches commencent clignoter, en attendant ce rglage. Appuyez sur la touche 4 pendant 4 sec. Le rglage du code utilisateur 4 chiffres (4 bips). Appuyez sur la touche 5 pendant 5 sec. Le rglage du code utilisateur 5 chiffres (5 bips). Aprs ce rglage, le clavier acceptera les codes dutilisateur seulement composes de 4 ou 5 chiffres. Si aucun autre changement nest effectu (changer le code matre, mmorisation du code utilisateur,...), lextraction de la batterie du clavier permet de rinitialiser le GALEOR et lui permet de retrouver les rglages dusine par dfaut. Cette manipulation ncessite de redfinir le nombre de chiffres du code utilisateur. Une fois dfini le nombre de chiffres et quaucun autre changement nest t effectu, la base de donnes demeure dfinitive et ne peut tre modifi e sans quune procdure de remise aux paramtres dusine par dfaut soit effectue (voir procdure B +3). 4 cdvigroup.com Modification code Matre Programmation code utilisateur A0 A1 1 bip 1 bip Tapez les termes du CODE UTILISATEUR Tapez les 5 termes du nouveau CODE MATRE Tapez :
-A = canal 1 seul
-B = canal 2 seul
-A et B = Canal 1 ou 2 1 bip = OK
(4 bips = Erreur) Message derreur si le code Matre tap correspond un code utilisateur en mmoire Tapez 0 pour confirmer 1 bip = OK
(4 bips = Erreur) Message derreur si le code Matre tap correspond un code utilisateur en mmoire
-------- ou --------
Mmoire complte
-------- ou --------
Code 12345 interdit MANUEL DINSTALLATION GALEOR Clavier cod radio rtro-clair FR Tapez 2 fois le CODE MATRE RAPPEL :
Si le clavier clignote pendant 1 sec. au premier contact, verifiez la pile. Rtro-clairage touches teint sauf touche 5 allum fixe Enregistrement du canal sur le rcepteur Effacer tous les codes utilisateurs Effacer un seul code utilisateur Avec ou sans Buzzer Change User code channel A2 A4 A5 A6 A7 1 bip 1 bip 1 bip 1 bip 1 bip La touche 5 clignote Slection du canal sur le rcepteur (dans les 30 sec. suivantes max.) Tapez A et B en simultane Tapez les termes du code utilisateur Tapez les termes du code utilisateur Tapez A ou B 1 bip = OK 1 bip = OK
(4 bips = Erreur) B Message derreur si le code nest pas mmoris Sortie programmation*
Si le Buzzer est activ, cette manipulation le dsactive, si il est dsactiv, cette manipulation lactive Tapez le canal A ou B de modifier Si le canal est dj en mmoire il sera effac, sinon il sera mmoris. Canal supprim = 2 Bips Canal mmoris = 1 Bip cdvigroup.com 5 INSTALLATION MANUEL MANUEL DINSTALLATION GALEO GALEOR Illuminated RF Keypad Clavier cod radio rtro-clair 8] REMISE A ZRO FR Pour viter toutes les mauvaises manipulations (intentionnelles ou non), la remise aux paramtres dusine par dfaut, ne peut tre effectue quavec le code matre 5 chiffres ou laide dun des codes utilisateurs mmoriss (avec 4 ou 5 chiffres). Ensuite, suivez la procdure A +1 ou B +3. REMISE A ZRO Remise zro du code Matre 12345 A+1 EN SIMULTANE 30 SECONDES Remise zro usine B+3 EN SIMULTANE 30 SECONDES 2 bips 2 bips Tapez les 5 termes dun code en mmoire
(dans les 20 sec. suivantes max.) Tapez les 5 termes dun code en mmoire
(dans les 20 sec. suivantes max.) 3 bip = OK 4 bip = OK Naffecte pas les codes en mmoires Suppression des codes en mmoire, suppression des liens avec le rcepteur et Remise zro du code Matre 12345 Standard Note : A la fin de la procdure B +3, le code utilisateur enregistr au pralable sera supprim et le clavier doit tre de nouveau enregistr sur le rcepteur correspondant. 6 cdvigroup.com INSTALLATION MANUEL MANUEL DINSTALLATION GALEO GALEOR Illuminated RF Keypad Clavier cod radio rtro-clair 9] GARANTIE VIE [ExTRAIT]*
FR Les socits CDVI garantissent que ce produit est dpourvu de tout vice cach, tant dans les matriaux que dans sa fabrication, la condition, quil soit install conformment aux prconisations du fabricant et quil ny ait pas eu dinterventions ou de modifications sur le produit. La responsabilit de CDVI se limite la rparation ou lchange du produit. CDVI nassume aucune responsabilit concernant les dommages sur les biens ou les personnes. Un produit reconnu dfectueux par CDVI doit tre retourn au service-aprs-vente de CDVI, aprs lobtention du numro dautorisation de Retour de Produit(s) Dfectueux (RMA). La responsabilit de CDVI se limite la rparation ou au remplacement dun produit ou pices dfectueuses, en ses ateliers. Lune ou lautre de ces interventions sont dfinis par le service-aprs-vente de CDVI. Le prjudice imputable CDVI ne saurait en aucun cas dpasser la valeur du produit. La responsabilit de CDVI ne peut tre engage auprs de lacheteur, installateur, client final ou qui que ce soit, lors de dommages conscutifs des imperfections ou mauvais fonctionnement du produit. Cette garantie prend effet la date denregistrement du produit auprs de CDVI, partir de linstant ou la date denregistrement est dment complte, dans la limite dun mois, aprs la date de livraison au client final. Pour obtenir les dtails complets de cette garantie et enregistrer votre/vos produit(s) pour bnficier de cette Garantie Vie limite . Veuillez complter la carte denregistrement prsente dans la boite du produit et nous la retourner, par email ou par courrier, ladresse de lentit CDVI la plus proche ou vous enregistrer en ligne ladresse www.cdvigroup.com. Les contacts des entits CDVI sont accessibles en ligne ladresse www.cdvigroup.com ou au dos de la notice dinstallation. ExCLUSIONS DE LA GARANTIE : A lEXCEPTION DES POINTS EVOQUES PRECEDEMMENT, CDVI NAPPLIQUE AUCUNE GARANTIE, NI DELIBEREE NI TACITE, A TOUS LES PROBLEMES INCLUANT LE CONDITIONNEMENT, LE TRANSPORT, LEUR COMMERCIALISATION OU LES CONDITIONS DUTILISATIONS PARTICULIRES. 10] NOTES The device complies with part 15 of the FCC Rules. Operation is subjected to the following 2 conditions: (1) this device may not cause harmful interference and (2) this deivice must accept any interference received, including interference that may cause undesired operation RF EXPOSURE WARNING This EUT is in compliance with MPE for general population / uncontrolled exposure limits and it had been tested in accordance with the measurement methods and procedures specified in FCC 47 CFR 1.1310 and 2.1091 To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance are not recommended. The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter.
* Voir les conditions de garantie vie limite compltes sur le site cdvigroup.com. cdvigroup.com 7 EN 77 INSTALLATION MANUEL INSTALLATION MANUAL GALEO GALEOR Illuminated RF Keypad Illuminated RF Keypad Thank you for buying our products and for the confidence you placed in our company. 7 2 HIGH RESISTANCE TO VANDALISM Environmental tests:
vibrations WEEE Environmental test:
Salt spray IP64 Certification CE
-25C a +70C 2 1 1 1] GENERAL INFORMATION Wireless RF keypad. Polished heavy duty Zamak cast alloy. Backlit keys. Frequency : 433,92 Mhz. 2 channels (buttons A and B). Compatible with Erone receivers. Compact. Surface mount. Mounting with Torx screws Partially sealed with epoxy. 22 User codes - 4 or 5 digits. 1 Master code - 5 digits. Audible and visual feedback. Modulation: AM/ASK. Encoding: Keeloq hopping code Dimensions (L x W x D):
GALEOR = 110 x 75 x 15mm, Supply: Lithium battery 3,6V - LS14500. Current consumption:
- 28 mA in transmission,
- 0,8uA in sleep-mode. 2] NOTES & RECOMMENDATIONS Mounting recommendations Mount the keypad on a flat surface to avoid any vandalism and to insure the best mounting. 3] MOUNTING KIT FCC ID : PWN1002000029 The device complies with part 15 of the FCC Rules. Operation is subjected to the following 2 conditions:
(1) this device may not cause harmful interference and
(2) this device must accept any interference received, including interference that may cause undesired operation Security advice For security advice reasons, change the factory default master code. When selecting a master code and user code avoid sequencial codes (example : 3 4 5 6 7).
(M4x10) Torx screw) T20 Torx Spanner Cache vis plastique
(M4x30) mounting screws Plastic anchors Battery Foam GALEOR 1 1 1 2 2 1 1
* Supplied. 8 cdvigroup.com Certification FCC CFR 47part 15 compliance INSTALLATION MANUEL INSTALLATION MANUAL GALEO GALEOR Illuminated RF Keypad Illuminated RF Keypad 4] MOUNTING Drill the 2 mounting holes (drill bit 5 mm and 35 MM hole depth) and the hole wiring access. Insert the 2 plastic anchors in the holes. Stick the foam to sealed The GALEOR on the back side of the base (Important). Place the back plate of the GALEOR and screw on the wall using the supplied (M4x30) mounting screws. EN Remove the plastic protection of the battery and then mount the keypad on the back plate, placing first the top in the hooks and then the bottom. Fasten the GALEOR keypad to the back plate by using the supplied (M4x10) Torx screw and T20 Torx spanner hardware. Place the screw cap at the bottom of the keypad. 5] USER CODES TABLE Channel Channel User A B Code Name User A B Code Name 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 cdvigroup.com 9 INSTALLATION MANUAL GALEOR Illuminated RF Keypad 6] PROGRAMMING EN GALEOR FACTORY SETTINGS :
- No user codes.
- Buzzer ON
- Time-out backlit : 3 Sec.
- Transmission time-out : 25 seconds
- Factory master code : 1 2 3 4 5.
- Programming time-out : 10 seconds.
- Channel choices :
Channel 1 = A, Channel 2 = B. AUDIBLE FEEDBACKS :
1 beep : Power-up ( battery insertion ) 1 long beep :
- Enter on menu,
- Validation of a programming choice,
- Exit from a menu choice. 2 beeps : Confirm enter in factory recovery 3 beeps : confirm factory recovery A+1 4 beeps :
- Confirm factory recovery B+3,
- Error for wrong channel,
- Error for insertion of a code already Memorized. USING RULES AND USER CODES:
- All the buttons can be used to compose the personal access code, except A and B.
- The master code must be composed by 5 digits.
- The user codes can be composed by 4 or 5 digits according to initial setting
- The master code cannot be used as transmission code. 7] GETTING STARTED The keypad comes without any setting for the user digit number. At the battery insertion the 12 leds start to blink, waiting for this setting. PRESS the key 4 for 4 sec. to set 4-digits user codes --> 4 beeps PRESS the key 5 for 5 sec. to set 5-digits user codes --> 5 beeps After this setting, the keypad will accept only user codes composed by 4 or 5 digits, according to the choice made. If no change is done ( change of the master code, user code memorization, etc ) just by removing the battery the keypad comes back the factory settings and requires again to set the number of digits. Once set the number of digits and made any change, the data-base remains definite and cannot be changed unless a factory default procedure is carried out ( see procedure B+3). 10 cdvigroup.com Change Master code User code programming A0 A1 1 beep 1 beep Type the 5 digits of the new Master code 1 beep = OK
(4 beeps = Error) Error message if the Master code typed corresponds to User code in memory Type the digits of the USER CODE Then press :
-A = Only channel 1
-B = Only channel 2
-A & B = Channel 1 or Channel 2 Press 0 to confirm 1 beep = OK
(4 beeps = Error) Error message if the User code typed corresponds to a user code in memory
-------- or --------
the memory is full
-------- or --------
is 12345 INSTALLATION MANUAL GALEOR Illuminated RF Keypad EN Type 2 times the MASTER CODE REMINDER:
if the keypad blinks during 1 sec. at the first touch, check the battery. Buttons backlit switch off except button 5 Memorization of the channel onto the receiver A2 Delete all user codes Delete a single user code Buzzer ON / OFF Change User code channel A4 A5 A6 A7 1 beep 1 beep 1 beep 1 beep 1 beep button 5 blinks Press A and B simultaneously Type the digits of the USER CODE Type the digits of the USER CODE Select the corresponding relay on the receiver
(within next 30 sec.) Press A or B 1 beep = OK 1 beep = OK
(4 beeps = Error) Press the channel to change ( A or B ) Error message if the code typed is not in memory If the buzzer is enabled it will be disabled and viceversa. B Programming exit*
the channel If was memorized it will be deleted, if not it will me memorized. CH DELETED : 2 Beeps CH MEMORIZED : 1 Beep
* The programming mode is limited to 10 sec. without any action on the keypad ( no buttons pressed ) cdvigroup.com 11 INSTALLATION MANUAL GALEOR Illuminated RF Keypad 8] FACTORY RECOVERY EN To avoid any damage action ( intentional or not ) the factory recovery can be carried out only by the owner of the 5-digit Master code or knowing any User code memorized ( with 4 or 5 digits) . According to that and the final purpose of the recovery, follow the procedure A+1 or B+3. FACTORY RECOVER Master code reset to factory value 12345 A+1 SIMULTANEOUSLY FOR 30 SECONDS Recover to factory settings B+3 SIMULTANEOUSLY FOR 30 SECONDS 2 beeps 2 beeps Within 20 sec. type the digits of a memorized code Within 20 sec. type the digits of a memorized code 3 beeps = OK 4 beeps = OK Doesnt affect the user codes memorized Deletes all User codes memorized on the keypad, recovers the choice to 4 or 5 digits, deletes the link with the receiver and resets the Master code to 12345. Normal mode NOTE : At the end of procedure B+3, even the user code typed within the procedure will be deleted and the keypad must be memorized again onto the corresponding receiver. 12 cdvigroup.com INSTALLATION MANUAL GALEOR Illuminated RF Keypad EN 9] LIMITED LIFETIME WARRANTY [ExTRACT]*
CDVI warrants this product to be free from defects in material and workmanship, when it has been installed in accordance with the manufacturers instructions and has not been modified or tampered with. Only product recognized by CDVI to be defective should be returned under these warranty terms if accompanied by an RMA (Return Material Authorization Number) provided by CDVI. CDVI, at its option, shall repair or replace the defective product at CDVI premises or at any CDVI approved service center. This warranty does not cover any damage due to accident, misuse, abuse or negligence. This warranty is valid only if the product is registered, within 1 month from delivery to the final costumer. To obtain full details of this warranty and to register the product to commence the Limited Lifetime Warranty, complete the enclosed registration card and return it, either by e-mail or post, to the relevant CDVI address or completion of the on line registration at www.cdvigroup.com. Repair or replacement of the defective product is the exclusive remedy. CDVI shall not be liable for any incidental or consequential damages arising from any defect in, or malfunction of, its product. In no event the entire liability can not exceed the purchase price of the product. The CDVI local country contact details can be found on line by visiting www.cdvigroup.com or on the back cover of the installation manual. DISCLAIMER OF WARRANTY: EXCEPT AS STATED ABOVE, CDVI MAKES NO WARRANTIES, EITHER EXPRESS OR IMPLIED, AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITION OF ITS PRODUCTS, THE TRANSPORTATION, THEIR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. 10] NOTES The device complies with part 15 of the FCC Rules. Operation is subjected to the following 2 conditions: (1) this device may not cause harmful interference and (2) this deivice must accept any interference received, including interference that may cause undesired operation RF EXPOSURE WARNING This EUT is in compliance with MPE for general population / uncontrolled exposure limits and it had been tested in accordance with the measurement methods and procedures specified in FCC 47 CFR 1.1310 and 2.1091. To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of 20 cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance are not recommended. The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter.
* Refer to complete limited lifetime warranty on cdvigroup website. cdvigroup.com 13 INSTALLATION MANUAL GALEOR Illuminated RF Keypad NOTES EN 14 cdvigroup.com INSTALLATION MANUAL GALEOR Illuminated RF Keypad NOTES EN cdvigroup.com 15 Reference : G0301FR0409V02 Extranet : EXE-CDVI_IM GALEOR CMYK A5 EN-FR 02 Creator of electronic access solutions
*G0301FR0409V02*
CDVI Group FRANCE (Headquarter/Sige social) Phone: +33 (0)1 48 91 01 02 Fax: +33 (0)1 48 91 21 21 i
) s n o i s n e m d d n a s n o i t a c fi i c e p s
, s e r u t a e f
, g n w a r d
, s o t o h p
t n e m u c o d s i h t n h t i i i i w d e n a t n o c n o i t a m r o f n i e h t l l A
. e c i t o n r o i r p t u o h t i w d e g n a h c e b n a c d n a t n e r e f f i d y b i t p e c r e p e b d u o c l l s e u q i t s i r t c a r a c
, s n i s s e d
, s o t o h p
t n e m u c o d t n e s r p e l r u s f i t a c i d n i e r t i t s e n n o i t n e m s n o i t a m r o f n i s e l s e t u o T l l i l
. e b a a r p n o i t a c fi i t o n s n a s s n o i t a c fi d o m e d s e b i t p e c s u s t n o s t e r e i r a v t n e v u e p
) s n o i s n e m d t e s e u q n h c e t i i CDVI FRANCE + EXPORT Phone: +33 (0)1 48 91 01 02 Fax: +33 (0)1 48 91 21 21 CDVI AMERICAS
[CANADA - USA]
Phone: +1 (450) 682 7945 Fax: +1 (450) 682 9590 CDVI BENELUX
[BELGIUM - NETHERLAND - LUXEMBOURG]
Phone: +32 (0) 56 73 93 00 Fax: +32 (0) 56 73 93 05 CDVI SUISSE Phone: +41 (0)21 882 18 41 Fax: +41 (0)21 882 18 42 CDVI CHINA Phone: +86 (0)10 62414516 Fax: +86 (0)10 62414519 CDVI IBRICA
[SPAIN - PORTUGAL]
Phone: +34 (0)935 390 966 Fax: +34 (0)935 390 970 CDVI ITALIA Phone: +39 0321 90573 Fax: +39 0321 908018 CDVI MAROC Phone: +212 (0)5 22 48 09 40 Fax: +212 (0)5 22 48 34 69 CDVI SWEDEN
[SWEDEN - DENMARK - NORWAY - FINLAND]
Phone: +46 (0)31 760 19 30 Fax: +46 (0)31 748 09 30 CDVI UK
[UNITED KINGDOM - IRELAND]
Phone: +44 (0)1628 531300 Fax: +44 (0)1628 531003 DIGIT FRANCE Phone: +33 (0)1 41 71 06 85 Fax: +33 (0)1 41 71 06 86 cdvigroup.com