Two-Year Limited Warranty CAD Audio hereby warrants that this product will be free of defects in material and workmanship for a period of two years from the date of purchase. In the unlikely event that a defect occurs CAD Audio will, at its option, either repair or replace with a new unit of equal or greater value. Retain proof of purchase to validate the purchase date and return it with any warranty claim. This warranty excludes exterior finish or appearance, damage from abuse, misuse of the product, use contrary to CAD Audios instructions or unauthorized repair. All implied warranties, merchantability, or fitness for a particular purpose is hereby disclaimed and CAD Audio hereby disclaims liability for incidental, special or consequential damages resulting from the use or unavailability of this product. This warranty gives you specific legal rights and you may have other rights that vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above exclusions and limitations may not apply to you. Note: No other warranty, written or oral is authorized by CAD Audio. Shipping Instructions Please call our customer service department at 440-349-4900 for a pre-approved return authorization number. Carefully repack the unit and return the insured package to:
CAD Audio, 6573 Cochran Road, Building I, Solon, Ohio 44139. RETURNS WITHOUT A PRE-APPROVED RETURN AUTHORIZATION NUMBER WILL BE REFUSED. If outside the United States, contact your local dealer or distributor for warranty details. 13 Individuals with cardiac pacemakers and other similar medical devices should consult with their physician before using any RF devices. Though the output level of this wireless system is below 50 milliwatts, the proximity of the transmitter to the implant device could pose a threat. As with any wireless product, environmental conditions can reduce or in some cases prohibit a successful connection between the transmitter and the receiver. This device complies with Part 15 of the FCC Rules. Most users of CAD Audio wireless products in the United States do not need a license for operation. However, the rules for unlicensed operation state that this device must not operate in excess of 50 milliwatts and it must not cause harmful interference to other wireless devices, and must accept interference received from other devices. Wireless products meeting CAD factory standards adhere to these rules. The FCC reserves the right to change these rules at any time. For more information contact the FCC at 1-888-CALL-FCC (TTY: 1-888-TELL-FCC) or visit the FCCs wireless microphone website at:
www.fcc.gov/cgb/wirelessmicrophones This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformment la rglementation dIndustrie Canada, le prsent metteur radio peut fonctionner avec une antenne dun type et dun gain maximal (ou infrieur) approuv pour lmetteur par Industrie Canada. Dans le but de rduire les risques de brouillage radiolectrique lintention des autres utilisateurs, il faut choisir le type dantenne et son gain de sorte que la puissance isotrope rayonne quivalente
(p.i.r.e.) ne dpasse pas lintensit ncessaire ltablissement dune communication satisfaisante. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autoris e aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. CADLiveTM WX3000 Introduction CADLiveTM is designed to outperform your expectations and deliver exceptional performance. Engineered to compliment the new generation of exceptional sound systems - The CADLive Series taps our Equitek studio heritage along with our live sound know-how in creating an impactful and easy-to-use line of mics. The CADLive 3000 series feature True Diversity operation to minimize multipath interference along with CADLock Automatic Tone Encoded Squelch to eliminate unauthorized transmissions in the signal path. Frequency agile design when partnered with ScanLink technology will precisely scan, select and link to the optimum channel allowing for an easy, flexible frequency plan. The CADLive handheld transmitter features metal construction and the CADLive D90 Supercardioid dynamic capsule provides a powerful, smooth and highly articulate profile. The handheld and body pack transmitters also include SoftTouch multi-function On-Off/Mute switches. CADLive bodypack transmitters are equipped with CADTone circuitry ensuring accurate reproduction of Hi-Z guitar and Lo-Z mic inputs. CADLive wireless features 10, 30, 50mW transmitter power adjustment and dynamic range up to 110dB. Receivers and transmitters are equipped with a high definition LCD display and full RF, AF, Battery Life, Mic Sensitivity and RF power metering. Receivers are housed in an all-metal chassis and supplied with single/
dual rack ears and a BNC relocation kit. Body pack systems include Equitek E19 earworn and E29 lavalier mics. Both systems are supplied with a heavy-duty carry case. The CADLiveTM WX3000 includes the following features:
True Diversity to minimize multipath interference CADLock Automatic Tone Encoded Squelch eliminates unauthorized interference Frequency agile operation for maximum frequency plan flexibility ScanLink technology for instantaneous and automatic channel configuration CADTone Body Pack input Optimized Impedance interface -
Hi-Z for Guitar and Lo-Z for mic Metal construction Handheld Transmitter equipped with CADLive D90 capsule High Contrast LCD displays on TX and RX Transmitters feature 10, 30, 50mW power adjustment to aid in multiple system applications 12 1 Simultaneous usage of up to 15 systems per frequency band Dynamic Range > 110dB AA Batteries with up to 15 Hrs of battery life Systems ship with rack ears single/dual BNC relocation kit and durable carry case BodyPack systems include miniature E19 Earworn, E29 Lav, WXGTR guitar cable XLR and " outputs on receiver Using the DA4090 Distribution Amplifier to Simplify Multiple-System Installations 1. BNC 50 ohm cable. 2. Power cable. 3. Power adapter. receiver menu. Startup Guide 1. Install new high quality alkaline batteries into transmitter, observing proper polarity. 2. Power up receiver by holding power button for one second. 3. Hold the SET button for one second to unlock the 4. Hold the SCAN button for one second to activate the ScanLinkTM environmental frequency analysis, which automatically selects a clear operating frequency. 5. Turn on the transmitter by holding the power button 6. Open the battery compartment to reveal the IR node. 7. Press the LINK button (note the IR node will illuminate). Align Your system is now ScanLink'd. the two IR nodes (transmitter and receiver) at a distance of 4"-12" (ambient room light can affect distance) for a few seconds while the receiver updates the transmitter. for one second. IR ScanLink LINK IR ScanLink LINK SET SCAN SET SCAN DA4090 DISTRIBUTION AMPLIFIER IR ScanLink LINK IR ScanLink LINK SET SCAN SET SCAN 2 11 Receiver RX3000 (Rear) 1. DC power input jack. 12-18VDC, 300mA min, center positive. 2. XLRM-type low-impedance balanced audio output. 3. 1/4" [6.35mm] high-level unbalanced ouput 4. BNC 50 ohm antenna inputs. 1 2 3 4 4 Simultaneous Use 580 - 600MHz Band R Group Channel 1 1 1 3 3 3 3 4 4 4 5 6 6 8 9 1 3 9 5 6 7 9 2 3 7 9 1 8 5 9 Frequency 580.000 584.600 600.000 586.900 588.800 590.900 597.400 581.000 583.300 588.600 598.100 581.300 595.700 591.200 599.400 Simultaneous Use 655 - 679MHz Band S Group Channel 1 9 12 1 4 5 10 12 1 5 12 6 2 12 3 1 1 1 2 2 2 2 2 3 3 5 6 8 8 10 Frequency 655.400 672.275 677.750 656.250 661.725 663.350 673.425 678.600 655.200 660.750 677.225 668.675 657.800 678.900 661.500 8 5 Channelization These frequencies have been approved for use within the United States and Canada as of the date of publication of this manual. It is the users responsibility to comply with local regulations. 580 - 600MHz Band R 582.500 583.500 584.900 586.100 586.900 588.800 590.900 594.400 597.400 580.500 581.000 583.300 584.700 585.900 586.700 588.600 590.700 594.200 580.600 581.100 582.400 583.400 584.800 586.000 586.800 594.300 597.300 CH Group 1 Group 2 Group 3 Group 4 Group 5 1 580.000 580.800 2 582.200 583.000 3 584.600 584.000 4 586.600 585.400 5 588.500 587.400 6 590.600 589.300 7 593.500 591.400 8 596.500 595.200 9 600.000 598.100 CH Group 6 Group 7 Group 8 Group 9 1 581.300 583.100 2 582.800 584.200 3 584.500 587.300 4 587.100 593.300 5 587.900 599.200 6 589.800 584.400 7 592.700 587.500 8 595.700 589.500 9 598.200 599.400 581.900 582.100 584.100 583.600 586.500 584.300 587.700 585.300 591.000 591.200 593.700 593.900 595.800 596.000 597.700 597.900 599.300 599.500 655 - 679MHz Band S CH Group 1 Group 2 Group 3 Group 4 Group 5 1 655.400 656.100 2 658.500 657.225 3 660.575 659.550 4 662.050 661.575 5 664.425 663.900 6 666.200 667.500 7 669.450 668.750 8 670.650 670.300 9 672.275 671.400 10 674.775 672.800 11 676.500 674.500 12 677.750 677.225 656.250 657.500 659.225 661.725 663.350 664.550 667.800 669.575 671.950 673.425 675.500 678.600 655.200 656.675 657.800 659.450 660.750 663.200 665.325 669.225 671.525 673.575 676.600 678.575 656.775 659.500 661.200 662.600 663.700 665.250 666.500 670.100 672.425 674.450 675.775 677.900 CH Group 6 Group 7 Group 8 Group 9 Group 10 1 655.425 657.075 2 657.400 659.800 3 660.425 661.500 4 662.475 662.900 5 664.775 664.000 6 668.675 665.550 7 670.800 666.800 8 673.250 670.400 9 674.550 672.725 10 676.200 674.750 11 677.325 676.075 12 678.800 678.200 655.700 656.550 658.800 657.800 660.875 659.825 662.350 662.025 664.725 663.650 666.500 664.850 669.750 668.100 670.950 669.875 672.575 672.250 675.075 673.725 676.800 675.800 678.050 678.900 655.500 656.975 658.100 659.750 660.050 663.500 665.525 669.525 671.825 673.875 676.900 678.875 6 7 FCC WARNING This device complies with Part 74 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE 2: This device complied with FCC radiation exposure limits as set forth for an uscontrolled environment. This device should be installed and operated so that its antenna(s) are not co-located or operating in conjunction with any other antenna or transmitter