TECHNICAL INFORMATION MANUAL Revision 0.3 04 July 2019 R4320C High Performance 4-port Embedded RAIN RFID Reader Visit the Hadron R4320C web page, you will find the latest revision of data sheets, manuals, certifications, technical drawings, software and firmware. All you need to start using your tag in a few clicks!
Scope of Manual The goal of this manual is to provide the basic information to work with the Hadron R4320C Reader. Change Document Record Date Revision 23 Oct 2018 0 12 Mar 2019 0.1 01 July 2019 0.2 04 July 2019 0.3 Changes Preliminary Release Added Federal Communications Commission (FCC) Notice (Preliminary) Added FCC Compliance paragraph in the Regulatory Compliance chapter Updated FCC Compliance paragraph in the Regulatory Compliance chapter Updated FCC Compliance paragraph in the Regulatory Compliance chapter Pages
-
2 24 24 24 Reference Document
[RD1]
EPCglobal: EPC Radio-Frequency Communications at 860 MHz 960 MHz, Version 2.0.1 (April, 2015). Identity Protocols Class-1 Generation-2 UHF RFID Protocol for CAEN RFID srl Via Vetraia, 11 55049 Viareggio (LU) - ITALY Tel. +39.0584.388.398 Fax +39.0584.388.959 info@caenrfid.com www.caenrfid.com CAEN RFID srl 2019 Disclaimer No part of this manual may be reproduced in any form or by any means, electronic, mechanical, recording, or otherwise, without the prior written permission of CAEN RFID. The information contained herein has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. CAEN RFID reserves the right to modify its products specifications without giving any notice; for up to date information please visit www.caenrfid.com. Federal Communications Commission (FCC) Notice (Preliminary) This device was tested and found to comply with the limits set forth in Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This device generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instruction manual, the product may cause harmful interference to radio communications. Operation of this product in a residential area is likely to cause harmful interference, in which case, the user is required to correct the interference at their own expense. The authority to operate this product is conditioned by the requirements that no modifications be made to the equipment unless the changes or modifications are expressly approved by CAEN RFID. Preliminary Product Information This document contains information for a new product. CAEN RFID reserves the right to modify this product without notice. Preliminary product information describes products that are ready for production, but for which full characterization data is not yet available. CAEN RFID believes that the information contained in this document is accurate and reliable. However, the information is subject to change without notice and is provided AS IS without warranty of any kind
(Express or implied). You are advised to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. No responsibility is assumed by CAEN RFID for the use of this information, including use of this information as the basis for manufacture or sale of any items, or for infringement of patents or other rights of third parties. Disposal of the product Do not dispose the product in municipal or household waste. Please check your local regulations for disposal/recycle of electronic products. Index 2 Scope of Manual ...........................................................................................................................................................................2 Change Document Record ............................................................................................................................................................2 Reference Document ....................................................................................................................................................................2 Index ........................................................................................................................................................................................... 4 List of Figures ................................................................................................................................................................................. 4 List of Tables .................................................................................................................................................................................. 5 1 INTRODUCTION ................................................................................................................................................................... 6 Product Description ......................................................................................................................................................................6 Development Kit ...........................................................................................................................................................................8 Ordering Options ..........................................................................................................................................................................9 HADRON R4320C ............................................................................................................................................................... 10 Technical Specifications Table ....................................................................................................................................................10 External Connections ..................................................................................................................................................................11 Connector pinout ...........................................................................................................................................................11 Power supply and interface connector electrical characteristics ..................................................................................12 Power supply connection ...............................................................................................................................................13 General purpose I/O connections ..................................................................................................................................13 Shutdown pin .................................................................................................................................................................14 Communication interface selection ...............................................................................................................................14 UART connection ...........................................................................................................................................................14 FW Recovery/Upgrade ...................................................................................................................................................15 Antenna port specifications ...........................................................................................................................................16 Reader - Tag Link Profiles ...........................................................................................................................................................16 Firmware Upgrade ......................................................................................................................................................................16 HADRON R4320CEVB ......................................................................................................................................................... 19 Technical Specifications Table ....................................................................................................................................................19 Connection Diagram ...................................................................................................................................................................19 Installation Notice ..........................................................................................................................................................20 Technical drawings .....................................................................................................................................................................21 Electrical schematic ....................................................................................................................................................................22 External Connections ..................................................................................................................................................................23 LEDs ............................................................................................................................................................................................23 Firmware Upgrade ......................................................................................................................................................................23 REGULATORY COMPLIANCE............................................................................................................................................... 24 FCC Compliance ..........................................................................................................................................................................24 RoHS EU Directive .......................................................................................................................................................................25 3 4 List of Figures Fig. 1.1: Hadron reader (Model R4320C): top view .................................................................................................................................6 Fig. 1.2: Hadron reader (Model R4320C): bottom view ...........................................................................................................................6 Fig. 1.3: Hadron R4320CEVB Evaluation Board ........................................................................................................................................7 Fig. 1.4: R4320CXDK: Accessories kit with adapter, antennas, cable and demo tags ..............................................................................8 Fig. 2.1: Hadron R4320C Technical Drawings ........................................................................................................................................11 Fig. 2.2: Hadron R4320C Power Supply Connection ..............................................................................................................................13 Fig. 2.3: Hadron R4320C GPIO Connection Example .............................................................................................................................13 Fig. 2.4: Hadron R4320C SHUTDOWN pin connection ...........................................................................................................................14 Fig. 2.5: Hadron R4320C RS232 Connection ..........................................................................................................................................15 Fig. 2.6: Hadron R4320C ERASE Pin Connection ....................................................................................................................................15 Fig. 3.1: Hadron R4320CEVB Evaluation Board Connection Diagram ....................................................................................................19 Fig. 3.2: Connection of the R4320C module to the R4320CEVB evaluation board ................................................................................20 Fig. 3.3: Hadron R4320CEVB Technical Drawing ....................................................................................................................................21 Fig. 3.4: Hadron R4320CEVB Electrical Schematic ................................................................................................................................22 Index - Hadron Technical Information Manual 4 List of Tables Tab. 2.1: Hadron R4320C Technical Specifications ................................................................................................................................10 Tab. 2.2: Hadron R4320C Supply and Interface Connector Pinout ........................................................................................................11 Tab. 2.3: Hadron R4320C Supply and Interface Connector Electrical Characteristics...........................................................................12 Tab. 2.4: RF Port Pinout .........................................................................................................................................................................16 Tab. 2.5: RF Port Electrical Characteristics ............................................................................................................................................16 Tab. 2.6: Hadron R4320C Reader to Tag Link Profiles ...........................................................................................................................16 Tab. 3.1: Hadron R4320CEVB Technical Specifications ..........................................................................................................................19 Index - Hadron Technical Information Manual 5 1 INTRODUCTION Product Description The Hadron (Model R4320C), embedded module of the easy2read product line, is a RAIN RFID multiregional compact reader for high performances applications. With programmable output power from 10dBm to 31.5dBm, the reader reaches top reading performances being able to detect RAIN tags from a distance of 9 m (30 feet) depending on the antenna and the tag used. The radio frequency core of the module allows to achieve fast reading/writing operations and to work in dense reader and dense tag environments for top-class rated performances. Due to its compact form factor, the module is specifically designed to be easily embedded in battery powered devices such as high performances handhelds and sleds. Thanks to the 4-antenna ports and the high power capability, the Hadron module is the perfect RAIN RFID core component to design full size readers for portals, industrial automation readers or any RFID device requiring long reading distances. Fig. 1.1: Hadron reader (Model R4320C): top view Fig. 1.2: Hadron reader (Model R4320C): bottom view INTRODUCTION - Hadron Technical Information Manual 6 The Mod. R4320CEVB - R4320C Hadron Evaluation Board allows managing the Hadron R4320C reader directly via USB and RS232 interfaces. This board is particularly suited for Hadron R4320C reader evaluation and SW development purpose. Fig. 1.3: Hadron R4320CEVB Evaluation Board INTRODUCTION - Hadron Technical Information Manual 7 Development Kit A development kit with adapter, antennas, cable and demo tags is available:
Fig. 1.4: R4320CXDK: Accessories kit with adapter, antennas, cable and demo tags The kit includes:
n. 1 WR4320CXEVBX R4320C - Hadron - Evaluation Board n.1 Circular Polarized Quadrifilar Antenna MMCX (ETSI or FCC) n. 1 Set of Labels n. 1 A927Z Temperature Logger Tag n. 1 RT0005 Temperature Logger Tag n. 1 WALIM0000002 Power Supply for Hadron R4320C Adapter Board n. 1 USB cable The R4320C Hadron reader and its development kit are a complete set up for a quick implementation of RFID solutions. INTRODUCTION - Hadron Technical Information Manual 8 Ordering Options Code Reader WR4320CXAAAA Development kit Accessories WR4320CXDKEU WR4320CXDKUS WR4320CXEVBX WANT020XMMCX WANT021XMMCX WALIM0000002 Description R4320C - Hadron - High Performance 4-port Embedded UHF RFID Reader Hadron - ETSI Dev Kit with antenna, interface, power supply and tags
(reader not included) Hadron - FCC Dev Kit with antenna, interface, power supply and tags
(reader not included) R4320C - Hadron - Evaluation Board ANT020/MMCX - Quad - Circular polarized quadrifilar antenna (ETSI) -
MMCX ANT021/MMCX - Quad - Circular polarized quadrifilar antenna (FCC) -
MMCX Power Supply for Hadron R4320C Adapter Board INTRODUCTION - Hadron Technical Information Manual 9 2 HADRON R4320C Technical Specifications Table Frequency Range RF Power Output Power Accuracy Antenna VSWR Requirement Antenna Connectors Frequency Tolerance Number of Channels Standard Compliance Digital I/O Forward Link Characteristics Return Link Characteristics Connectivity Dimensions Power Consumption
(max) DC Power Operating Temperature Weight 865.600867.600 MHz (ETSI EN 302 208 v3.1.1) 902928 MHz (FCC part 15.247) Programmable from 10dBm to 31.5dBm (30dBm for FCC)
+/- 1dB1
< 2:1 for optimum performances Nr. 4 MMCX jacks 10ppm over the entire temperature range 4 channels (compliant to ETSI EN 302 208 v3.1.1) 50 hopping channels (compliant to FCC part 15.247) EPC C1G2 / ISO18000-63 4 I/O lines 3.3V out @ 3mA; 5V tolerant PR-ASK 40kBit/s; DSB-ASK 160kBit/s (FCC only) Miller encoding (M=4; LF=250kHz) Miller encoding (M=4; LF=300kHz) FM0 400kbit/s (FCC only) USB interface One USB 2.0 Full Speed (12 Mbit/s) device port UART Serial Port Baudrate: up to 115200 Databits: 8 Stopbits:1 Parity: none Flow control: none 3.3 V I/O voltage level
(L) 60 x (W) 42 x (H) 7,5 mm3 8.5W peak (TX/RX mode) 3,5 VDC 5.5 VDC
-20C to +60C 35 g Tab. 2.1: Hadron R4320C Technical Specifications Warning: The RF settings must match the country/region of operating to comply with local laws and regulations. The usage of the reader in different countries/regions from the one in which the device has been sold is not allowed. Y 1 For output power less than 14dBm the accuracy may exceed the specification HADRON R4320C- Hadron Technical Information Manual 10 External Connections The location of the connectors is shown in Fig. 2.1: Hadron R4320C Technical Drawings page 11. Their part numbers are listed here below:
Antenna Ports: RF Coax Connector Huber+Suhner type 82_MMCX-S50-0-2/111_K (to be used with Huber+Suhner type 11_MMCX-50-1-1/111_O) MOLEX Connector: PCB Header Molex type 53261-1571
(to be used with Molex Type 51021-1500 + 15pcs crimp terminal type 50058-8100) Fig. 2.1: Hadron R4320C Technical Drawings Connector pinout In the following table Hadron R4320C power supply and interface connector pinout is reported. Pin #
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Name GND GND VCC VCC GPIO0 GPIO1 GPIO2 GPIO3 RXD TXD USB DM USB DP 5V USB SHUTDOWN ERASE Direction
-
-
-
-
IN/OUT IN/OUT IN/OUT IN/OUT IN OUT IN/OUT IN/OUT IN IN IN Function Ground Ground Supply voltage Supply voltage General purpose I/O #0 General purpose I/O #1 General purpose I/O #2 General purpose I/O #3 UART RX (input to the module) UART TX (output from the module) USB DM signal USB DP signal USB supply voltage input Shutdown of the module FW recovery/upgrade enabling Tab. 2.2: Hadron R4320C Supply and Interface Connector Pinout The GPIO0-GPIO3 pins are 4 general purpose bidirectional pins, their default direction is IN. HADRON R4320C- Hadron Technical Information Manual 11 The RXD/TXD pins are used to communicate with the R4320C board via UART port; to establish a link with the device you must configure your COM port as follows2:
Baud rate:
115200 Parity:
None Data bits:
Stop bits:
8 1 Flow Control: none 5V USB signal is used to sense the presence of an USB host device connected to the module and not for supply the device. This pin shall be left unconnected for UART operation. Powering on the module with ERASE pin tied at high level for more than 220ms enables the internal microcontroller FW recovery/upgrade procedure. When SHUTDOWN pin is at high level the internal circuitry of the module is powered off and the current consumption is reduced down to less than 1mA. Power supply and interface connector electrical characteristics3 Pin name Pin No. Parameter VCC 3,4 GPIO[0:3]
5, 6, 7, 8 RXD TXD 9 10 USB DM 11 USB DP 12 5V USB 13 SHUTDOWN 14 ERASE GND 15 1,2 Supply DC voltage Supply DC current VOL VOH Output current VIL VIH Input current VIL VIH Input current VOL VOH Output current VIL VIH VOL VOH VIL VIH VOL VOH VIL VIH Input current VIL VIH Input current VIL VIH Input current Min 3.5 0.25 0 2.0
-0.3 2.0
-0.3 2.0 0 2.4 2 0 2.8 2 0 2.8
-0.3 2 0 2 0 2 Typ 4.25 Max Unit 5.5 2.4 0.4 3.3 3.0 0.8 5.5 1 0.8 5.5 1 0.4 3.3 1.5 0.8 0.3 3.3 0.8 0.3 3.3 0.8 5.5 1 0.8 5.5 40 0.8 5.5 6 V A V V mA V V A V V A V V mA V V V V V V V V V V A V V A V V mA Tab. 2.3: Hadron R4320C Supply and Interface Connector Electrical Characteristics 2 Since R4320C RX/TX are TTL level signals, in order to connect it with a PC, a TTL/RS232 translator shall be used. 3 Exceeding maximum values reported in the table may cause permanent damage to the model. HADRON R4320C- Hadron Technical Information Manual 12 Power supply connection In the following schematic suggested R4320C power supply connection is shown. The use of a resettable fuse (F1) is recommended since R4320C does not provide internal current limitation protection. Diode D1 avoid damage to the reader in case of reverse polarity connection. Fig. 2.2: Hadron R4320C Power Supply Connection General purpose I/O connections The GPIO0-GPIO3 pins are 4 general-purpose bidirectional pins. Their default direction after a power on reset or a general reset is set to input. GPIO, when configured as Outputs, can be used to drive indicators as LEDs or buzzers or to send trigger signal to others equipment. GPIO, when configured as Inputs, can accept control signals from other equipment or trigger signals from sensors (i.e. photocells). In the following schematic an example of application of GPIO is shown. Fig. 2.3: Hadron R4320C GPIO Connection Example HADRON R4320C- Hadron Technical Information Manual 13 Shutdown pin R4320C SHUTDOWN pin allows to set the module in power off mode (current consumption less than 1mA) and can be used also for manual reset operation. SHUTDOWN pin is pulled-down by an internal resistor. Fig. 2.4: Hadron R4320C SHUTDOWN pin connection Communication interface selection The communication with Hadron R4320C module can be performed via UART or USB interface. If at power up an USB host is already connected to the module the USB interface is selected otherwise if USB pins are not connected the UART interface is selected. UART connection The RXD/TXD pins are used to communicate with the R4320C module via UART port. Since R4320C RX/TX are TTL level signals, in order to connect it with a PC, a TTL/RS232 translator shall be used (please refer to the diagram below)4. To establish a link with the device host COM port shall be configured as follows:
Baud rate:
115200 Parity:
None Data bits:
Stop bits:
8 1 Flow Control: none 4 R4320C service board (R4320CEVB) hosts both RS232 and USB full interfaces. HADRON R4320C- Hadron Technical Information Manual 14 Fig. 2.5: Hadron R4320C RS232 Connection FW Recovery/Upgrade ERASE pin is reserved and shall be used only to perform the microcontroller FW recovery/upgrade procedure during which it must be forced at high level (3.3V or 5V). In the following diagram a manual recovery mechanism is shown: in order to perform the R4320C boot recovery the jumper JP shall be inserted, then R4320C module shall be switched on for 5s at least. After that the reader shall be switched off and the jumper removed: at the next switch on the reader will execute the boot recovery program. For further details please see Firmware Upgrade page 16. Fig. 2.6: Hadron R4320C ERASE Pin Connection HADRON R4320C- Hadron Technical Information Manual 15 Antenna port specifications In the following table the pinout of R4320C antenna ports is shown. Pin #
INNER OUTER Function RF OUT GND Tab. 2.4: RF Port Pinout Parameter RF output power (nominal) Output power vs. power setting accuracy RF port impedance Recommended antenna VSWR Tab. 2.5: RF Port Electrical Characteristics Direction OUT
-
Description RF output Ground Min 10 10 Typ. 50 Max 1400 31.5 1 2:1 Unit mW dBm dB5
-
Reader - Tag Link Profiles R4320C reader supports different modulation and return link profiles according to EPC Class1 Gen2 protocol [RD1]. In the following table are reported all profiles that have been tested for the compliance with ETSI and FCC regulations. Link profile #
Regulation 1 2 3 FCC ETSI FCC Tab. 2.6: Hadron R4320C Reader to Tag Link Profiles Modulation PR-ASK; f=40kHz PR-ASK; f=40kHz Return Link Miller (M=4); f = 250kHz Miller (M=4); f = 300kHz DSB-ASK; f=160kHz FM0; f = 400kHz Firmware Upgrade R4320C reader firmware upgrade can be performed via USB or RS232 interface. In the following procedure it is assumed to use the R4320CEVB adapter board and a PC as host. 1) With the board powered off insert the jumper J5 in the position shown below. 5 For output power less than 14dBm the accuracy may exceed the specification HADRON R4320C- Hadron Technical Information Manual 16 2) Power on the board for at least 5s. 3) Remove the power supply. 4) Place the jumper in the original position. 5) Connect the USB or the RS232 cable to the board. 6) Power on the board. 7) Launch the R4320C Upgrade Tool and click on Next button. 8) Select the COM port related to the device (the COM address of RS232 in case of use of the serial interface, the Bossa Program Port assigned by OS in case of use of the USB interface). Note that the driver identification name depends on the OS type version. 9) Select the R4320C FW image file. 10) Click on Upgrade Firmware button. 11) Wait for the progress bar to be full. HADRON R4320C- Hadron Technical Information Manual 17 12) Switch off the module; at the next power on the device will be operating with the new FW image. HADRON R4320C- Hadron Technical Information Manual 18 3 HADRON R4320CEVB Technical Specifications Table USB Port Digital I/O RS232 Port Four I/O lines 3.3 V out @ 3mA, 5 V tolerant USB B female connector USB 2.0 device It appears as R4320C Virtual COM Port device; drivers for all Windows OS Baudrate: 115200 Databits: 8 Stopbits: 1 Parity: none Flow control: none 9.6115 kbit/s data rate (settable) RED: Power GREEN: GPIO[0..3], USB connection YELLOW: RECOVERY procedure
(W)81 x (L)76 x (H)28 mm3
(3.2 x 3.0 x 1.1 inch3) DC Voltage 5V +/-5%
Current consumption: 2A max.
-20 C to +60 C Tab. 3.1: Hadron R4320CEVB Technical Specifications Operating Temperature Electrical Power Dimensions LED display Connection Diagram The following block diagram shows how to connect the Hadron R4320C with the PC host via the Hadron R4320CEVB service board. The board equipped with R4320C reader shall be powered by an external 5V 2A DC adapter. Fig. 3.1: Hadron R4320CEVB Evaluation Board Connection Diagram HADRON R4320CEVB - Hadron Technical Information Manual 19 Installation Notice Fix the Hadron R4320C reader to the R4320CEVB board using 3 M2x12 countersunk screws and 3 M2 screws nuts and connect the Molex connectors. The reader case shall be kept electrically isolated via thermal sildpad from the ground plane. The correct way to connect the R4320C module to the R4320CEVB evaluation board is shown in the following picture:
Fig. 3.2: Connection of the R4320C module to the R4320CEVB evaluation board HADRON R4320CEVB - Hadron Technical Information Manual 20 Technical drawings The following drawing shows the R4320CEVB components position. Fig. 3.3: Hadron R4320CEVB Technical Drawing HADRON R4320CEVB - Hadron Technical Information Manual 21 Electrical schematic The electrical schematic of the Hadron R4320CEVB is shown in the following figure:
Fig. 3.4: Hadron R4320CEVB Electrical Schematic HADRON R4320CEVB - Hadron Technical Information Manual 22 External Connections Please refer to Fig. 3.3: Hadron R4320CEVB Technical Drawing page 21. J1: free PTH pads for GPIO external connection J1-1 = GPIO0 (in/out) J1-2 = GPIO3 (in/out) J1-3 = GPIO1 (in/out) J1-4 = ERASE J1-5 = GPIO2 (in/out) J1-6 = Not Connected J2: Power Supply connector: central pin (2.54mm diam.) is the positive terminal. J3: RS232 DB9 female connector J4: USB Type B port J5: Connector for FW Recovery/Upgrade Procedure LEDs Please refer to Fig. 3.3: Hadron R4320CEVB Technical Drawing page 21. DL1 (red) = Power Supply DL2 (green) = GPIO0 DL3 (green) = GPIO1 DL4 (green) = GPIO2 DL5 (green) = GPIO3 DL6 (yellow) = ERASE DL7 (green) = USB connection Firmware Upgrade Please refer to Firmware Upgrade page 16. HADRON R4320CEVB - Hadron Technical Information Manual 23 4 REGULATORY COMPLIANCE FCC Compliance This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
a. Reorient or relocate the receiving antenna. b. Increase the separation between the equipment and receiver. c. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. d. Consult the dealer or an experienced radio/TV technician for help. This tansmitter module has been tested and found to comply with Part 15 of the FCC Rules. NOTE:
a. Any changes or modifications not approved by CAEN RFID could void the users authority to operate the equipment. b. Hadron R4320C module is approved for operation with the following antennas:
CAEN RFID antenna Mod. WANTENNAX020 Circular polarized antenna FCC with 5.5dBi gain CAEN RFID antenna Mod. WANT021XMMCX QUAD Circular Polarized Quadrifilar Antenna FCC with 0.7dBi gain c. Use of other than the approved antennas with this unit may result in harmful interference with other users and cause the unit to fail to meet regulatory requirements. d. The device requires professional installation since one of the approved antennas (CAEN RFID mod. WANTENNAX020) has a standard type N connector. e. The device shall be used such that a minimum separation distance of 25cm is maintained between each antenna and user's/nearby people's body. f. This transmitter module is authorized to be used in other devices only by OEM integrators under the following conditions:
1. The RFID Module antenna shall have a separation distance of at least 25 cm from all persons 2. The transmitter module must not be co-located with any other antenna or transmitter g. The host integrator installing this module into their product must ensure that the final composite product complies with the FCC requirements by a technical assessment or evaluation to the FCC rules, including the transmitter operation and should refer to guidance in KDB 996369. h. The module is authorized for FCC part 15.247 only, the host product manufacturer is responsible for compliance to any other FCC rules that apply to the host not covered by the modular transmitter grant of certification. i. The module has been tested and found to comply with the limits for a Class B digital device, however the final host product still requires Part 15 Subpart B compliance testing with the modular transmitter installed. REGULATORY COMPLIANCE - Hadron Technical Information Manual 24 j. If the FCC ID is not visible when the module is installed inside another device, the OEM integrator shall apply a label in a visible area on his product with the following statement:
Contains Transmitter Module FCC ID: UVECAENRFID027 or Contains FCC ID: UVECAENRFID027 RoHS EU Directive The Hadron R4320C RFID reader is compliant with the EU Directive 2011/65/CE on the Restriction of the Use of certain Hazardous Substances in Electrical and Electronic Equipment (RoHS2). REGULATORY COMPLIANCE - Hadron Technical Information Manual 25