Outdoor Powering Up Configure Management PC Quick Link Setup Hardware Overview Hardware Overview 1. 2. 3. Connect the Ethernet cable from Ethl/PoE-IN of e700 to the PoE port of Gigabit Data + Power Connect an Ethernet cable from your LAN or Computer to the Gigabit Data port of the PoE adapter. Connect the Power Cord to the adapter, and then plug the Power Cord into a power outlet. Once powered ON Power LED should illuminate continuously on PoE Adapter.
**Shielded Category 5 (or above) cabling should be used for all outdoor wired Ethernet connections and should be grounded through the AC ground of the PoE. 1. Select Properties for the Ethernet port. In Windows it is found in Control Panel > Network and Internet > Network Connections > Local Area Connection. 4 Local Area Connection Properties Navnxking Authentication | Sharing Connect using:
IntetfR) Ethernet Connection 1217-LM a CaetQM... This connection uses thefdowung items 0 '^ Qert for Microsoft Networks 0 JJunr Network Service 0 JSjOoS Packet Scheduler 0 Hemet Protocol Veron S (TCP/lPv6) 0 Hemet Protocol Version 4 (TCP/lPv4) Punter Sharing for Microsoft Networks 2. IP Address Configuration Default IP address received via DHCP. cnPilot e700 will use a default static IP address of 192.168.0.1, If there is no DHCP server Internet Protocol Version 4 (TCP/IPv4) Properties General You car get IP settings assigned automatically if your network supports this capability. Otherwise, you need to ask your network administrator for tho appropriate IP settings. Obtain an IP address automatically 9.i Use the following IP address:
IP address:
Subnet mask:
Default gateway:
3. Default Login information
- Username: admin
- Password: admin Management Protocols enabled by default -http or https (webpage management interface access), SSH (CLI management interface access). 1. 2. 3. 4. 5. 6. 7. Using a web browser, navigate to 169.254.1.1 and login with username: admin and password: admin Navigate to the Quick Start menu and click the GoTo Next Page. Configure your Region and Country of operation. Click the GoTo Next Page. Configure the Carrier Frequency. Click the GoTo Next Page. Select the Synchronization source. Click the GoTo Next Page. Configuration - IP Address, a Subnet Mask, and a Gateway IP Address OR DHCP state to Enabled to have the IP address, subnet mask, and gateway IP address automatically configured by a DHCP server. Click the Go To Next Page. Click the Save Changes button. Click the Reboot button. CD A System LED Network LED LED Colour Status Indication System LED colour is "Amber E700 is Powering up (Initializing) D System LED colour is "Green"
A Network LED colour is "Amber"
E700 is fully powered E700 is not connected to cnMaestro Network LED colour is "Blue"
E700 is connected to cnMaestro Reset E Main Port Secondary Port Secondary Port The Secondary port is a Gigabit Ethernet port used for bridging. Reset The Reset button serves two functions for e700:
- To restart, press and release the Reset button quickly.
- To restore to factory default settings, press and hold the Reset button for more than 10 seconds. Main Port The Main port is a Gigabit Ethernet port used to connect the power should be connected to the LAN and DHCP server. Specifications Safety Notice FCC Compliance RoHS/WEEE/CE Compliance 1C Statement Product Dimension Weight with Mounting Kit Networking Interface Operating Frequency 2.4 GHz 5 GHz Bluetooth Antenna Gain Beamwidth Max Power Consumption Max TX Power (Conducted*) 2.4 GHz 5 GHz Bluetooth Power Supply Wi-Fi Standards Wireless Security Operating Modes Mounting Supported Pole Size IP Rating Operating Temperature Operating Humidity Certification
*Regulatory dependent Model: cnPilot e700 315 x 215 x 66mm 3.74 lbs. (1700 grams) 10/100/1000 Mbps Ethernet ports (Two RJ45s) 2412 - 2472 MHz 5180 - 5850 MHz 2402 - 2480 MHz 7.8 dBi (2.4 GHz) and 7.8 dBi (5 GHz) 360 Omni directional 24.5W, 37.5W (with Auxiliary device powered) 25 dBm 28 dBm 9 dBm 56V/60W Gigabit passive PoE Adapter or 802.3at PSE 802.11a/b/g/n/ac WPA/WPA2 Pre-shared keys, WPA2 Enterprise Wireless Client Connectivity,Mesh Wall/Poie (Kits included) 38.1 to 76.2 (mm) 1.5" to 3.0" (Inch) IP 67 (completely protected from dust and can also withstand being submerged in lm of static water for up to 30 minutes)
-40C to +65C 5-95% Noncondensing CE, FCC, 1C Warning:
To prevent loss of life or physical injury, observe the following safety guidelines. In no event shall Cambium Networks be liable for any injury or damage caused during the installation of e700 platform. Ensure that only qualified personnel install. Only use attachments/accessories specified by the manufacturer. Electrical Safety Information l. Compliance with manufacturers label for voltage, frequency, and current requirements. Connecting to a different power source than those specified may result in improper operation, damage to equipment or pose a fire hazard if the limitations are not followed. 2. 3. There are no serviceable parts inside this equipment. Service should be provided only by a qualified service technician. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet. a. b. c. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment. d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection. e. Protective bonding must be installed in accordance with local national wiring rules and regulations. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For product available in the USA/Canada market, only channel 1-11 can be operated. Selection of other channels is not possible. Professional installation is required. IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distancecm the radiator &
your body. Caring for the Environment: RoHS/WEEE European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product. CE Marking This equipment complies with EU radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator
& your body. All operational modes:
2.4GHz: 802.11b, 802.11g, 802.11n (HT20), 802.11n (HT40) 5GHz: 802.11a, 802.11ac (VHT20), 802.11ac (VHT40), 802.11ac (VHT80) The frequency, mode and the maximum transmitted power in EU are listed below:
2412-2472MHZ (802.11n HT40 MCSO): 18.48 dBm 5500-5700MHZ (802.11ac VHT80 MCSO/NssI): 28.14 dBm 5745-5825 MHz (802.11ac (VHT20)-(ChS-20MHz): 28.04 dBm Hereby, [Cambium Networks Inc.] declares that the radio equipment type [cnPilot e700] is in compliance with Directive 2014/53/EU. C This device complies with Industry Canada license-exempt RSS standard(s). Operation is subje following two conditions: (1) this device may not cause interference, and (2) this device must a interference, including interference that may cause undesired operation of the device. Le present appareil est conforme aux CNR d'lndustrie Canada applicables aux appareils radio ex licence. L'exploitation est autorisee aux deux conditions suivantes : (1) 1'appareil ne doit pas proc brouillage, et (2) I'utilisateur de /'appareil doit accepter tout brouillage radioelectrique subi, men brouillage est susceptible d'en compromettre le fonctionnement. For product available in the USA/Canada market, only channel 1-11 can be operated. Selection <
channels is not possible. Pour les produits disponibles aux Etats-Unis / Canada du marche, seul le canal 1 a 77 peuvent etre Selection d'autres canaux n'est pas possible. IMPORTANT NOTE:
1C Radiation Exposure Statement:
This equipment complies with 1C RSS-102 radiation exposure limits set forth for an uncontrollec environment. This equipment should be installed and operated with minimum distance 28 cm t radiator & your body. Cet equipement est conforme aux limites d'exposition aux rayonnements 1C etablies pour un en\
non controle. Cet equipement doit etre installe et utilise avec un minimum de 28 cm de distance source de rayonnement et votre corps. Online Resources User Guide and software downloads:
https://support.cambiumnetworks.com/files/e700/
Support:
http://www.cambiumnetworks.com/support/
Contact us:
http://www.cambiumnetworks.com/support/contact-support/