R F C o m p o n e n t s September 2016 Multilayer Antenna For 2400-2484MHz ANT016008LCS2442MA1 1.6x0.8mm [EIA 0603]*
* Dimensions Code JIS[EIA]
R F C o m p o n e n t s Multilayer Antenna For 2400-2484MHz ANT016008LCS2442MA1 Conformity to RoHS Directive SHAPES AND DIMENSIONS
[Top view]
1.600.10 0.40max. 0 1
. 0 0 8
. 0
[Bottom view]
0.200.10
(0.1) 0 1
. 0 3 6
. 0
(1)
(2)
(3)
(6)
(5)
) 1
. 0
(4) Terminal functions 1 Radiator electrode 2 Dummy pad 3 Dummy pad 4 Feed point 5 Dummy pad 6 Dummy pad 0.250.10 0.2150.10 Dimensions in mm RECOMMENDED LAND PATTERN SOLDER RESIST PATTERN 1.60 0.90 0.60 1 2
. 0 1.53 0.90 0.60 3 7
. 0 0 8
. 0 Dimensions in mm 1 1
. 0 3 7
. 0 Dimensions in mm RoHS Directive Compliant Product: See the following for more details.https://product.tdk.com/info/en/environment/rohs/index.html All specifications are subject to change without notice.
Before using these products, be sure to request the delivery specifications. 20160926 / rf_ant_ant016008lcs2442ma1_summary R F C o m p o n e n t s ANT016008LCS2442MA1 EVALUATION BOARD Ft-1 ANT016008LCS2442MA1 PCB size : 50mm x 10mm x 1mm Antenna area : 5 x 3 mm Ft-1 Mt Component P/N 6.2pF 0.8pF Mt Measurement condition for Radiation Pattern Chip antenna PCB Z X Er E E Y
All specifications are subject to change without notice.
Before using these products, be sure to request the delivery specifications. 20160926 / rf_ant_ant016008lcs2442ma1_summary Max. 3.0 Typ. 1.60 Linear 5020 53 50 (Nominal) R F C o m p o n e n t s ANT016008LCS2442MA1 ELECTRICAL CHARACTERISTICS Frequency Range
(MHz) 2400 to 2484 Min. Item VSWR Polarization PCB size (mm) Antenna keep-out area (mm) Characteristic Impedance () This is typical antenna performance with the standard PCB. TEMPERATURE RANGE Operating temperature C 40 to +85 Storage temperature C 40 to +85 FREQUENCY CHARACTERISTICS EFFICIENCY AND VSWR 0 1 2 3 4 5 6 7 8
) B d
y c n e c i f f i E 9 10 2.300 11 10 9 8 7 6 5 4 3 R W S V 2.400 2.500 Frequency(GHz) 2 1 2.600 Efficiency Spec (VSWR) VSWR
Tested antenna has been soldered. Evaluation board size is 50x20x1 mm.
All specifications are subject to change without notice.
Before using these products, be sure to request the delivery specifications. 20160926 / rf_ant_ant016008lcs2442ma1_summary R F C o m p o n e n t s ANT016008LCS2442MA1 RADIATION PATTERNS 2.4GHz BAND 315 0 10(dBi) 0 10 20 30 40 45 315 90 270 0 10(dBi) 0 10 20 30 40 45 90 Y 270 270 Z 0 90 X 225 135 180 Horizontal polarization 2442 21.5 18.5 40.8 2400 21.5 16.9 46.0 Frequency(MHz) Average(dBi) Maximum(dBi) Minimum(dBi) 2400MHz 2442MHz 2484MHz 225 135 180 Vertical polarization 2400MHz 2442MHz 2484MHz 2484 21.3 17.2 36.4 Frequency(MHz) Average(dBi) Maximum(dBi) Minimum(dBi) 2400 0.0 1.3 2.4 2442 0.3 1.6 2.2 2484 0.2 1.2 3.0 315 0 10(dBi) 0 10 20 30 40 45 315 90 270 0 10(dBi) 0 10 20 30 40 50 45 90 270 90 Y 270 0 Z X 225 135 180 Horizontal polarization 2442 2.6 1.6 21.9 2400 2.9 1.3 21.5 Frequency(MHz) Average(dBi) Maximum(dBi) Minimum(dBi) 2400MHz 2442MHz 2484MHz 225 135 180 Vertical polarization 2400MHz 2442MHz 2484MHz 2484 3.1 1.2 23.6 Frequency(MHz) Average(dBi) Maximum(dBi) Minimum(dBi) 2400 24.1 20.2 39.2 2442 24.7 19.1 46.1 2484 24.8 21.5 34.9 315 0 10(dBi) 0 10 20 30 40 Z 270 45 315 90 270 0 10(dBi) 0 10 20 30 40 45 90 270 X 0 90 Y 225 135 180 Horizontal polarization 2442 2.7 0.6 28.5 2400 3.1 0.2 29.8 Frequency(MHz) Average(dBi) Maximum(dBi) Minimum(dBi) 2400MHz 2442MHz 2484MHz 225 135 180 Vertical polarization 2400MHz 2442MHz 2484MHz 2484 3.2 0.1 31.3 Frequency(MHz) Average(dBi) Maximum(dBi) Minimum(dBi) 2400 12.2 8.0 31.2 2442 11.8 7.5 30.5 2484 12.3 8.2 35.8
Tested antenna has been soldered. Evaluation board size is 50201 mm.
All specifications are subject to change without notice.
Before using these products, be sure to request the delivery specifications. 20160926 / rf_ant_ant016008lcs2442ma1_summary R F C o m p o n e n t s RECOMMENDED REFLOW PROFILE Preheating Soldering e r u t a r e p m e T
T T1 t1 6C/sec or lower T3 Peak T4 t3 t2 3C/sec or lower T3 T2 t: Time Preheating Temp. T1 150C T2 200C Time t1 60 to 120sec t3 : Time within 5C of actual peak temperature The maximum number of reflow is 3. Soldering Critical zone (T3 to T4) Time Temp. t2 T3 60 to 120sec 217C Peak Temp. T4 240 to 260C Time t3 30sec max.
All specifications are subject to change without notice.
Before using these products, be sure to request the delivery specifications. R F C o m p o n e n t s ANT016008LCS2442MA1 PACKAGING STYLE REEL DIMENSIONS 2.00.5 0 0
. 1 0
0 6 9.0 +1.0 0.0 13.01.0 Dimensions in mm 130.2 210.8 180 +0 1.5 TAPE DIMENSIONS Material of carrier the tape: PS J G H t E D C B A F K A B 0.970.05 1.80.05 C 8.00.2 D E 3.50.05 1.750.1 F 4.00.1 G 2.00.05 H J K t 4.00.1 1.5+0.1/-0 0.55max. 0.250.05 Dimensions in mm PACKAGE QUANTITY Standard package quantity
(pieces/reel) 4,000
All specifications are subject to change without notice.
Before using these products, be sure to request the delivery specifications. 20160926 / rf_ant_ant016008lcs2442ma1_summary R F C o m p o n e n t s REMINDERS FOR USING THESE PRODUCTS Before using these products, be sure to request the delivery specifications. SAFETY REMINDERS Please pay sufficient attention to the warnings for safe designing when using these products. REMINDERS The products listed on this catalog are intended for use in general electronic equipment (AV equipment, telecommunications equipment, home appliances, amusement equipment, computer equipment, personal equipment, office equipment, measurement equipment, industrial robots) under a normal operation and use condition. The products are not designed or warranted to meet the requirements of the applications listed below, whose performance and/or quality require a more stringent level of safety or reliability, or whose failure, malfunction or trouble could cause serious damage to society, person or property. Please understand that we are not responsible for any damage or liability caused by use of the products in any of the applications below or for any other use exceeding the range or conditions set forth in this catalog.
(1) Aerospace/Aviation equipment
(2) Transportation equipment (cars, electric trains, ships, etc.)
(3) Medical equipment
(4) Power-generation control equipment
(5) Atomic energy-related equipment
(6) Seabed equipment
(7) Transportation control equipment
(8) Public information-processing equipment
(9) Military equipment
(10) Electric heating apparatus, burning equipment
(11) Disaster prevention/crime prevention equipment
(12) Safety equipment
(13) Other applications that are not considered general-purpose applications When using this product in general-purpose applications, you are kindly requested to take into consideration securing protection circuit/
equipment or providing backup circuits, etc., to ensure higher safety.
All specifications are subject to change without notice.
Before using these products, be sure to request the delivery specifications. 20160926 / rf_ant_ant016008lcs2442ma1_summary