all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 2 3 |
|
User Manual | Users Manual | 1.41 MiB | May 12 2013 | |||
1 2 3 |
|
Internal Photos | Internal Photos | 5.37 MiB | May 12 2013 | |||
1 2 3 |
|
External Photos | External Photos | 362.26 KiB | May 12 2013 | |||
1 2 3 |
|
Label and Location | ID Label/Location Info | 520.79 KiB | May 12 2013 | |||
1 2 3 |
|
Attestation (DFS Client Declaration) | Attestation Statements | 567.05 KiB | May 12 2013 | |||
1 2 3 |
|
Confidentiality Request (Shortterm) | Cover Letter(s) | 175.46 KiB | May 12 2013 | |||
1 2 3 |
|
Confidentiality Request | Cover Letter(s) | 240.11 KiB | May 12 2013 | |||
1 2 3 |
|
Cover Letter (Agent Authorization) | Cover Letter(s) | 200.49 KiB | May 12 2013 | |||
1 2 3 |
|
Operational Description | Operational Description | 12.05 KiB | May 12 2013 | |||
1 2 3 | RF Exposure Info | May 12 2013 | ||||||
1 2 3 | Test Report | May 12 2013 | ||||||
1 2 3 | Test Report | May 12 2013 | ||||||
1 2 3 | Test Report | May 12 2013 | ||||||
1 2 3 | Test Report | May 12 2013 | ||||||
1 2 3 | Test Setup Photos | May 12 2013 |
1 2 3 | User Manual | Users Manual | 1.41 MiB | May 12 2013 |
what it takes to connect. Capsule Neuron 2 Hardware Installation and Maintenance Guide DRAFT Copyright 2013 Capsule Technologie. DC-NU2-IM-DOC 0.8 October 30, 2013 Legal Notice Copyright 2013 Capsule Technologie. All rights reserved. h s i l g n E This product and related documentation are protected by copyright and distributed under licensing restricting their use, copying, distribution, and decompilation. No part of this product or related documentation may be reproduced in any form or by any means without prior written authorization of Capsule Technologie. While every precaution has been taken in the preparation of this documentation, the document is provided "as is" and Capsule Technologie assumes no responsibility for any typographical, technical, or other inaccuracies in this document. Capsule Technologie reserves the right to change, modify, transfer, or otherwise revise this publication without notice. Trademarks The DataCaptor and Capsule Neuron families of related marks, images, and symbols are the exclusive properties of Capsule Technologie. Corepoint Integration EngineTM is a trademark of Corepoint Health. DISPATCH is a registered trademark of Caltech Industries, Inc. Clorox is a registered trademark and Clorox Healthcare is a trademark of the Clorox Company. Sani-Cloth is a registered trademark of PDI, Inc. 2 Contents Contents Chapter 1: Introducing the Capsule Neuron 2 Overview Intended Use About this document Product Purpose Audience Notes, cautions, warnings Related documents Manufacturers information Getting additional information Table of abbreviations Chapter 2: Setting up the Capsule Neuron Whats in this chapter Unpacking and inspecting the package contents Contents of a product shipment Unpacking the cartons Hardware installation prerequisites Installing the batteries in the Capsule Neuron Installing the main battery in the Capsule Neuron Installing the optional extended battery in the Capsule Neuron Deploying the Capsule Neuron Precautions for all deployments Considerations for wall-mounted deployments Mounting the Capsule Neuron on the wall Mounting the Capsule Neuron on a roll stand Connecting the Capsule Neuron to the power supply Power requirements Connecting the Capsule Neuron to the power supply Before you use the Capsule Neuron for the first time Chapter 3: Operating the Capsule Neuron Components on the Capsule Neuron Connectivity Serial Ports USB Ports Ethernet Port Powering on the Capsule Neuron Power on the Capsule Neuron Power Off the Capsule Neuron Working with the Capsule Neuron touch screen Reading the status LED Working with the batteries Battery Lifetime Terminology Battery Summary E n g l i s h 5 5 5 6 6 6 6 6 7 7 8 8 9 9 9 9 10 10 11 11 11 13 13 13 13 14 14 14 15 15 16 16 18 19 19 19 19 19 20 20 20 21 21 21 3 Charging the batteries Removing a battery Swapping a battery Connecting the Capsule Neuron to the network Connecting a vital signs monitor to the Capsule Neuron Before you connect Connecting the cables Connecting the devices For more on using the Capsule Neuron with the vital signs monitor Chapter 4: Maintaining the Capsule Neuron Periodic cleaning and disinfection Cleaning Precautions Periodic maintenance of the Capsule Neuron Authorized Access Inspections Storing the Capsule Neuron Maintenance of the Capsule Neuron batteries Cleaning Short-term maintenance Long-term storage and maintenance Chapter 5: Technical Information Guidance and manufacturers declaration Capsule Neuron technical specifications Device Identification Module (DIM) technical specifications Regulatory Information Explanation of Device and Packaging Symbols Safety and Regulatory Compliance EN/IEC Federal Communications Commission Declaration CE RoHS and WEEE Compliance Recycling and the Environment E n g l i s h 22 22 22 23 23 23 24 24 24 25 25 25 26 26 26 26 26 26 26 27 29 29 33 34 35 35 37 37 37 38 38 38 4 Introducing the Capsule Neuron 2 Overview 1 E n g l i s h The Capsule Neuron 2 is Capsule's point-of-care hardware platform for device connectivity. It is a flexible and scalable platform that you can configure to operate in various care areas of the hospital. In high acuity environments, such as the ICU, the Capsule Neuron 2 typically runs Capsules Status Application to enable continuous collection of vital signs for one patient from multiple devices. In low acuity, non-critical care settings (such as med-surg), the Capsule Neuron 2 typically runs Capsule's Mobile Vitals Plus Application to enable the automatic collection, validation, and transmission of vital signs from multiple patients to the EMR directly from the point of care. Note: Do not operate the Capsule Neuron 2 until after you read and understand these instructions. Pay particular attention to all warnings and cautions. Note: For information about the administration of DataCaptor software, IT personnel should refer to the DataCaptor System Administrators Guide. Note: To operate the Capsule Neuron 2, clinicians require training in the procedures described in the Capsule Neuron Status Application Clinical Users Guide and the Capsule Neuron Mobile Vitals Plus Application Clinical Users Guide. Note: To operate any medical device that connects to the Capsule Neuron, clinicians must be separately trained in the use of that device. Intended Use The intended use of the DataCaptor system is for data collection and clinical information management, either directly or through networks with independent bedside devices. Capsule's hardware and software are not intended for monitoring purposes, nor is the software intended to control any of the clinical devices (independent bedside devices/information systems) to which it is connected. There is no other known contraindication for the use of the Capsule Neuron 2 system. Caution: Do not modify the Capsule Neuron 2, cables, or any part of the DataCaptor Connectivity software, or mount the device in any way other than instructed in Capsule documents. Any modification to the hardware or software can prevent proper functioning and cause damage to the connected medical device. Installation and Maintenance Guide [Chapter 1]
5 About this document E n g l i s h Product The product described in this document is the Capsule Neuron 2 (part number: DC-NU2-UMPC). For brevity and clarity, that product is referred to in the rest of this document as the Capsule Neuron. This means that all references to Capsule Neuron in this document shall be understood as applying to part number DC-NU2-UMPC. Purpose This document provides:
instructions for installing, mounting, and connecting the Capsule Neuron hardware instructions for maintaining, cleaning, and storing the device and its accessories details of technical characteristics and regulatory compliance of the device Audience The target audiences for this document are:
Audience Description Biomedical staff The biomedical staff ensures that the medical equipment is safe, functional, and properly configured for the clinical environment. They install, inspect, and maintain biomedical devices and support systems to adhere to medical standard guidelines. Clinicians Clinicians are health care providers who interact with patients in a medical environment, such as a registered nurse, nurse technician, respiratory therapist, or anesthesiologist. Notes, cautions, warnings Where necessary, Capsule documents highlight any applicable warnings, cautions, and notes to avoid risk of injury to individuals or damage to equipment. There are three levels of information:
Warning:
Indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Caution:
Indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury or severe damage or malfunctioning of the equipment. Note:
Directions to clarify specific information to assist the user, and to avoid the risk of damage to the equipment described in this guide and/or any other equipment or goods, and/or cause environmental pollution. 6 Introducing the Capsule Neuron 2 [Chapter 1]
Related documents Capsule provides the following additional documents for use with the Capsule Neuron. Document DataCaptor System Administrator's Guide
(English only) Capsule Neuron Status Application Clinical User's Guide Capsule Neuron Mobile Vitals Plus Application Clinical Users Guide Description provides information on deployment scenarios and instructions on how to install, upgrade, and configure the DataCaptor software solution, including troubleshooting tips. Available from the:
Help menu of the Web Administration Console Capsule Customer Portal provides information on how to use the Status application, along with troubleshooting advice and hardware cleaning instructions. Available from the:
Help menu of the Web Administration Console Capsule Customer Portal icon in the application provides information on how to use the MVP application, along with troubleshooting advice and hardware cleaning instructions. Available from the:
Help menu of the Web Administration Console Capsule Customer Portal icon in the application Audience Hospital IT staff E n g l i s h Clinicians Clinicians Manufacturers information Capsule Tech, Inc. Capsule Technologie 300 Brickstone Square, Suite 203 Andover, MA 01810 USA Phone: 1-978-482-2300 Toll Free: 1-800-260-9537 9 Villa Pierre Ginier 75018, Paris France Phone: (+33) 1 5334 1400 Introducing the Capsule Neuron 2 [Chapter 1]
7 Getting additional information For more information, or to order additional products (Capsule Neurons, or accessories including batteries, power cables, printed copies of documents), contact your reseller or Capsule directly:
E n g l i s h USA EMEA & APAC Capsule Tech, Inc. 300 Brickstone Square, Suite 203 Andover, MA 01810 USA Phone: 1-978-482-2300 Toll Free: 1-800-260-9537 US Technical Support Phone: 1-800-260-9537 E-mail: support@capsuletech.com Table of abbreviations Capsule Technologie 9 Villa Pierre Ginier 75018, Paris France Phone: (+33) 1 5334 1400 EMEA & APAC Technical Support Phone: (+33) 1 5334 1400 E-mail: emea.support@capsuletech.com The table provides an alphabetical list of the main abbreviations used in this document. Abbreviation Meaning AC CE CISPR DIM DTS EN/IEC FCC GB LAN LED MVP RoHS VAC WEEE WLAN WPA Alternating Current Conformit Europenne (= European Conformity) Comit International Spcial des Perturbations Radiolectriques
(= Special international committee on radio interference) Device ID Module DataCaptor Terminal Server European Norm / International Electrotechnical Commission Federal Communications Commission Gigabyte Local Area Network Light Emitting Diode Mobile Vitals Plus Restriction of the use of Hazardous Substances Voltage in Alternating Current Waste Electrical and Electronic Equipment Directive Wireless Local Area Network Wireless Protected Access 8 Introducing the Capsule Neuron 2 [Chapter 1]
Setting up the Capsule Neuron Whats in this chapter Follow the instructions in this chapter to setup the Capsule Neuron. Deployment follows these steps, in this order:
2 E n g l i s h Unpacking and inspecting the package contents Installing the batteries in the Capsule Neuron Deploying the Capsule Neuron Mounting the Capsule Neuron on the wall Mounting the Capsule Neuron on a roll stand Connecting the Capsule Neuron to the power supply Before you use the Capsule Neuron for the first time Note: This document does not describe the configuration of the Capsule Neuron on a local network. Refer to the DataCaptor System Administrator's Guide. Unpacking and inspecting the package contents Before you install the Capsule Neuron in a clinical setting, you must inspect and set it up according to instructions. Contents of a product shipment The table describes the contents of a Capsule Neuron shipment. Item Capsule Neuron Shipment characteristics In one carton, you find the Capsule Neuron itself, wrapped in plastic and sandwiched between two blocks of polyethylene foam. Each Capsule Neuron is shipped along with:
Main battery The main battery is in position inside the Capsule Neuron, but the battery pins are not yet in contact with the battery socket on the Capsule Neuron, and the battery is not yet fixed in place. Power brick The power brick is shipped wrapped in plastic. Screws and washers Four M4 Phillips-head screws and their associated washers are shipped in a plastic bag with the Capsule Neuron. These screws are available for attaching the Capsule Neuron to a mounting bracket, depending on the deployment selected. Installation and Maintenance Guide [Chapter 2]
9 Item Power Cable h s i l g n E Extended battery
(optional) This document Shipment characteristics The electrical cable that is used to connect the Capsule Neuron power brick to the electrical mains outlet is shipped in a separate carton from the Capsule Neuron. This cable is always adapted to local requirements. If ordered, extended batteries are shipped in a separate carton, where possible, the same carton as for the cables. Each extended battery is packed in its own unit box. Printed copies of this Capsule Neuron 2 Hardware Installation and Maintenance Guide are shipped separately, in the same carton as the cables, where possible. The number of copies depends on the number of Capsule Neurons in the shipment. Additional elements Depending on the contents of your order, other connectivity elements such as serial cables, patch cables, and DIMs, could be present in the shipment. If yes, these are typically shipped in the same carton as for the cables. Unpacking the cartons Note:
If the carton is broken, open, or damaged in any way, do not accept the shipment. 1. Turn the carton so that the arrow on the package is pointing up. 2. Cut the tape on the carton. Caution: Be careful to cut only the tape and not, for example, the Capsule Neuron. 3. Take each item out of the carton. 4. Check all items against the packing list, and against the list in Contents of a product shipment above. 5. Remove the packing material and examine each item for any signs of shipping damage. 6. Save all packing materials, the invoice and the bill of lading. You will require them if you need to process a claim with the carrier. Hardware installation prerequisites You need the following tools (not included) to install the Capsule Neuron:
a cruciform-tip screwdriver a Phillips-head PH0 screwdriver In addition, depending on how you intend to mount the Capsule Neuron, you could require certain hardware:
If you select to deploy the Capsule Neuron on a roll stand, you must source a roll stand pole extension with VESA 75 or VESA 100 interface suitable for the model of your roll stand. Contact your roll stand manufacturer for options. 10 Setting up the Capsule Neuron [Chapter 2]
If you select to deploy the Capsule Neuron on a wall-mount, then you require a mounting solution that is VESA 75/100-compatible. Installing the batteries in the Capsule Neuron Installing the main battery in the Capsule Neuron The Capsule Neuron is shipped with the main battery in position but not yet fixed in place. E n g l i s h 1. Push the main battery towards its connection port. 2. Use a screwdriver or other tool to screw in the two screws that hold the main battery in place. 3. Tighten the screws until the battery is connected to its pins. Do not overtighten. Installing the optional extended battery in the Capsule Neuron 1. Turn the Capsule Neuron so that the screen is facing away from you. 2. Use a screwdriver to unscrew the screw that holds the extended battery faceplate in position. 3. Push the loose faceplate to the left, then lift the faceplate away from the Capsule Neuron. Setting up the Capsule Neuron [Chapter 2]
11 h s i l g n E 4. Position the extended battery at the same point where you lifted the faceplate. Because of the arrangement of the pins, you cannot position the extended battery incorrectly. 5. Slide the extended battery to the right. Continue sliding until the left side of the extended battery is flush with the left side of the extended battery slot. 6. Push the locking button on the extended battery to the down position. 12 Setting up the Capsule Neuron [Chapter 2]
Deploying the Capsule Neuron In typical deployments of the Capsule Neuron, you can mount it on the wall, or mount it on a roll stand or other mobile configuration. Note: For compliance with EN/IEC 60601-1, the Capsule Neuron is not classified as a portable device. Instead, the Capsule Neuron must be deployed as one of:
- Mobile device
- Fixed device E n g l i s h Precautions for all deployments Caution:
Do not place the Capsule Neuron inside furniture or inside any enclosed space. This could prevent correct cooling of the device and interfere with radio communications. Operate the Capsule Neuron only within these environmental conditions:
- Temperature: +10C to +40C (+32F to +104F)
- Atmospheric pressure: Atmospheric pressure: 700 hPa to 1060 hPa
- Altitude: -100 meters to +2000 meters (-328 feet to +6560 feet)
- Humidity: 10% to 95% RH non-condensing Do not stack the Capsule Neuron or place it next to other equipment. If you do, then check it for normal operation running its usual configuration. In semi-private rooms, connectors must be placed or labeled so that they clearly indicate the bed for which they collect data. Considerations for wall-mounted deployments When you are deciding where to place the Capsule Neuron at the point of care, Capsule recommends that you take account of the following considerations. Mount the Capsule Neuron near the head of the bed or on the head wall in the patient room. To allow clinicians easy access to the Capsule Neuron touch screen, mount the Capsule Neuron no more than 1.5 meters (5 feet) or less than 1 meter (3 feet, 3 inches) from the ground. If there are medical devices connected to the ports on the Capsule Neuron, position the Capsule Neuron on the same side of the bed as those devices. Make sure that you take account of the length of the cables required to connect the Capsule Neuron and the medical devices. Mounting the Capsule Neuron on the wall Caution: For Capsule Neurons that are installed above the patient, take adequate precautions to prevent them from falling on the patient. Attach the Capsule Neuron to your selected VESA 75/100 wall-mounted solution. Refer to the instructions from the solution manufacturer. Setting up the Capsule Neuron [Chapter 2]
13 Mounting the Capsule Neuron on a roll stand 1. Mount the Capsule Neuron to the roll stand. Refer to the manufacturers instructions for the roll stand as required. 2. To fix the device to the mounting bracket, use the four screws and washers that are delivered with your Capsule Neuron, or the screws delivered with your roll stand pole extension. h s i l g n E Connecting the Capsule Neuron to the power supply Once deployed, on a wall or roll stand for example, you can connect the Capsule Neuron to the power supply. Power requirements The Capsule Neuron is designed to use the IEC 60601-1-compliant, external DC power supply and power cables that are provided with the Capsule Neuron. For precise information, refer to the Technical Information in chapter 5 of this document. Cautions:
Always use the hospital-grade, AC power cable delivered with the product to connect the Capsule Neuron to an AC power source. Do not, under any circumstances, use any other cable than the one provided, even to provide extra cable length. The use of any other cable can result in increased emissions or decreased immunity of the device with regards to electromagnetic interference. Do not connect the Capsule Neuron to an AC outlet that is controlled with a switch or dimmer. Do not, under any circumstances, remove the grounding conductor from the power plug. Do not use extension cords or adapters of any type. The power cable, supply, and plug must remain intact and undamaged. The power plug must remain accessible to unplug the device from the power supply mains if necessary. 14 Setting up the Capsule Neuron [Chapter 2]
Connecting the Capsule Neuron to the power supply 1. The power brick that was shipped with your Capsule Neuron has a power cable on one end, and an open plug on the other end. Plug that power cable into the Capsule Neuron at the DC-in power connector (as illustrated). 2. Tighten the locking mechanism on the DC-in power connector to lock the power plug in place. 3. Plug the power cable that was shipped with your Capsule Neuron into the open plug on the power brick. 4. Plug the other end of that power cable into a grounded electrical outlet (generally 3-prongs). The Capsule Neuron switches on automatically. E n g l i s h Caution: For safety, cables are designed to prevent inadvertent disconnection if someone accidentally pulls on them. However, make sure that you route cables so that they do not present a tripping hazard. Warning:
You must only connect the Capsule Neurons power brick to an appropriate power source. To avoid risk of electric shock, use a grounded (3-prong) electrical power outlet. Before you use the Capsule Neuron for the first time For all deployments, before you use the Capsule Neuron for the first time, you must completely charge its battery. 1. Set up the Capsule Neuron as described in this chapter:
install the main battery install the extended battery, if you use one connect the Capsule Neuron to the electrical mains 2. The battery/ies start to charge as soon as you plug the Capsule Neuron into the electrical mains. Allow the main battery to charge for about two hours. If you have installed both the main battery and the optional extended battery, allow the two batteries to charge for about six hours. For a fuller description of the batteries, and the charging / discharging process, refer to Working with the batteries on page 21. Setting up the Capsule Neuron [Chapter 2]
15 Operating the Capsule Neuron 3 Components on the Capsule Neuron h s i l g n E Legends on the drawings In the legend for the drawings that follow:
Individual components keep the same numbers on each drawing. For example, the USB ports on
, 6
. When you see the number the bottom of the Capsule Neuron are shown with the number you know that it represents only these ports. 6 Colors have meaning. A blue circle indicates a medical-grade connector. A yellow circle indicates network connection (Ethernet). All other components are indicated with red circles. View from the front 1 1 2 3 4 5 6 Light sensor Touch screen Status LED RFID badging area Serial ports USB ports 2 3 4 5 6 16 Operating the Capsule Neuron [Chapter 3]
View from the bottom 5 6 5 6 7 8 Serial ports (4) - front-accessible USB ports (2) - front-accessible USB ports (2) - rear-accessible Serial port (1) - rear-accessible 9 Ethernet connection E n g l i s h 7 8 9 10 10 DC power-in connector 3/4 view from the back 8 7 5 Serial ports (4) - front-accessible 6 USB ports (2) - front-accessible 7 8 9 USB ports (2) - rear-accessible Serial port (1) - rear-accessible Ethernet connection 10 DC power-in connector 10 9 6 5 Operating the Capsule Neuron [Chapter 3]
17 View from the back h s i l g n E 11 12 12 13 12 12 16 15 Views from the side 11 Extended battery emplacement Mounting plate screwholes 12
(VESA 75/100 configuration) 14 13 Main battery 14 Covered USB port 15 Aeration vents 16 Speaker 17 13 14 13 14 Main battery Covered USB port 17 Anti-theft slot Connectivity The ports on the Capsule Neuron are used to connect medical or other devices. A blue line on these ports indicates a medical-grade connection port. A yellow line indicates the Ethernet connection port. The tables describe the ports. 18 Operating the Capsule Neuron [Chapter 3]
Serial Ports Location Characteristics Number Purpose Galvanic isolated RS-232 with RJ45 connector Galvanic isolated RS-232 with RJ50 connector 4 1 Used to connect medical devices with serial interfaces Used to connect medical devices with serial interfaces E n g l i s h Front Rear USB Ports Location Characteristics Number Purpose Front Rear Side (left) Galvanic isolated, Type A USB 2.0 full-speed Galvanic non-isolated, Type A USB 2.0 high-speed Galvanic non-isolated, Type A USB 2.0 high-speed 2 2 1 Used to connect medical devices with USB interfaces Used to connect external USB, non-medical devices such as barcode scanners Additional USB, non-medical device connection Ethernet Port Location Characteristics Number Purpose Back RJ45 connector 1 Used to connect to the hospital-internal, wired network (Ethernet) Powering on the Capsule Neuron For information on connecting the Capsule Neuron to the power supply, refer to Connecting the Capsule Neuron to the power supply on page 14. Power on the Capsule Neuron The Capsule Neuron switches on automatically when you plug it into any power source. For manual operation, press the Power On/Off button, shown at position on this illustration of the top view of a Capsule Neuron:
A Operating the Capsule Neuron [Chapter 3]
19 h s i l g n E A Power On/Off button Power Off the Capsule Neuron To power off the Capsule Neuron, press the On/Off button again. If the Capsule Neuron does not shut down properly for any reason, you can do a hard shutdown. Press and hold the power button for four seconds. Working with the Capsule Neuron touch screen The Capsule Neuron screen is a 10.1-inch (25.6-centimeter) touch screen. It is antiglare treated, and readable from multiple angles. Screen brightness adjusts automatically to the level of ambient light, dimming or brightening in parallel with the current level of luminosity in the room. If the screen goes completely dark, the Capsule Neuron is said to be in sleep mode, and you can wake it up by touching the screen. Reading the status LED The Capsule Neuron provides a single LED, located on the front of the device below the screen. LED Capsule Neuron Status Off Capsule Neuron is not running. Blue - Blinking Capsule Neuron is booting. Blue Red Capsule Neuron has finished booting, and is EMR-connected. Capsule Neuron has finished booting, and is not EMR-connected. 20 Operating the Capsule Neuron [Chapter 3]
Working with the batteries For instructions on installing the main battery, and the optional extended battery, refer to Installing the batteries in the Capsule Neuron on page 11. Note: Before you use each Capsule Neuron for the first time, you must fully charge its battery/ies, as described in Before you use the Capsule Neuron for the first time on page 15. E n g l i s h Battery Lifetime Terminology When describing the Capsule Neuron, the following terms are used:
Battery autonomy refers to the amount of time that the Capsule Neuron can remain fully functional in case of a disconnect from the electrical mains. Battery life span refers to the total time that the battery lasts before you must replace it. Battery Summary Characteristic Main Battery Extended Battery Autonomy 150 minutes (2 hours 30 minutes) of functional operation when unplugged from AC mains, with a new, fully-
charged battery 240 minutes (4 hours) of functional operation when unplugged from AC mains, with a new, fully-charged battery Charging time 120 minutes (2 hours) When used together, the two batteries together provide about 360 minutes (6 hours) of autonomy. 240 minutes (4 hours) for the extended battery alone 360 minutes (6 hours) to charge both batteries Charging Life span First charged / Last discharged Last charged / First discharged After 500 complete charging cycles, remaining capacity is about 80%. After 500 complete charging cycles, remaining capacity is about 80%. Alternatively, after 12 months of continuous use, remaining capacity is about 50%. Alternatively, after 12 months of continuous use, remaining capacity is about 50%. Shelf-life 3 months 3 months Replaceability By biomed user - requires no tools other than a screwdriver By clinical user - requires no tools other than a screwdriver Operating the Capsule Neuron [Chapter 3]
21 Charging the batteries To charge the batteries, plug the cable from the Capsule Neuron power brick into the AC power mains (wall socket). h s i l g n E To monitor the batteries during the charging process, check the battery information displayed on the screen, and described in the Capsule document, Clinical Users Guide for the Mobile Vitals Plus application. Removing a battery Caution: Before you remove a battery, make sure that the Capsule Neuron is receiving power, either from the electrical mains, or from at least one charged battery that is installed in the Capsule Neuron. Removing the main battery Refer to the illustrations for Installing the main battery in the Capsule Neuron on page 11. 1. Use a screwdriver or similar tool to unscrew the two screws that hold the battery in place. 2. Pull the battery gently away from the Capsule Neuron to disconnect the battery from the pins. 3. Remove the battery. Removing the extended battery Refer to the illustrations for Installing the optional extended battery in the Capsule Neuron on page 11. 1. To release the extended battery, push the locking button to the up position. 2. Slide the extended battery to the left. 3. Lift the battery out and away. 4. If desired, and if you have retained the faceplate, you can replace the faceplate on the empty battery slot. Use a screwdriver and the screw that you removed when you installed the extended battery. Swapping a battery To swap a charged battery in place of a discharged battery, or to swap a new replacement battery for a depleted battery:
1. Make sure that the Capsule Neuron is plugged into the electrical mains outlet. Alternatively, if you are working with both the main battery and an extended battery, make sure that the battery that you are not replacing is charged and continues to supply power to the Capsule Neuron at all times. 2. Remove the battery, as described above under Removing a battery. 3. Install the new battery, as described in Installing the batteries in the Capsule Neuron on page 11. 22 Operating the Capsule Neuron [Chapter 3]
E n g l i s h Connecting the Capsule Neuron to the network Connecting to a wired network 1. Plug one end of the LAN cable into the Ethernet connector, located on the rear panel of the Capsule Neuron, and marked with a yellow line. In the illustrations, on page 17 for example, this connector is labeled 9
. 2. Plug the other end of the same cable into the network socket (typically on the wall). Connecting to a wireless network No special procedures are required on the Capsule Neuron for wireless connection. However, each Capsule Neuron must be configured in the Web Administration Console to use the wireless network. Refer to the DataCaptor System Administrators Guide for more. Checking the wired connection On the Ethernet jack, there are two small LEDs. When you plug in the Ethernet connection cable, you can check the connection through the behavior of these LEDs:
LEDs State Meaning Link/Act Off The Capsule Neuron is not connected to the LAN Blinking Network activity 10/100/1000 On Off Link is active Connected to the LAN at 10 MB speed, or Not connected Green Orange Connected at 100 MB speed Connected at 1000 MB speed Checking the wireless connection You cannot check the wireless connection using Capsule Neuron hardware components. You must use the network connection information displayed on the screen, and described in the Clinical Users Guide for the Mobile Vitals Plus application or the Status application. Connecting a vital signs monitor to the Capsule Neuron Before you connect Before you connect a vital signs monitor to the Capsule Neuron, you must program its Capsule Device ID Module (DIM). A Capsule DIM is required for all devices connected to the Capsule Neuron. For information on how to program a Capsule DIM, refer to the DataCaptor System Administrators Guide. The Device ID Module (DIM) supports plug-and-play connectivity. Its automatic device identification feature allows users to connect and re-connect any biomedical device to the Capsule Neuron with ease. The separate DIM attached to each device through a cable assembly allows the Capsule Neuron to:
automatically identify the attached device Operating the Capsule Neuron [Chapter 3]
23 initialize the appropriate DataCaptor Device Interface (DDI) detect when the device is disconnected and re-connected Caution:
If you use unapproved cables to connect medical devices to the Capsule Neuron, you could cause damage to or malfunctioning of the medical device. h s i l g n E Connecting the cables 1. Attach the device cable from the device to the DIM (Device ID Module). 2. Attach the DIM patch cable to the RJ45-end of the DIM. Device cable DIM DIM patch cable Connecting the devices 1. Attach the RJ45-end of the cable assembly into one of the ports of the Capsule Neuron. Refer to the description of Connectivity on page 18 for the set of available ports. 2. Connect the other end of the cable assembly to the back of the vital signs monitor. 3. Tighten the thumb screws and secure the assembly behind the monitor. For more on using the Capsule Neuron with the vital signs monitor This manual does not describe the use of the Capsule Neuron with vital signs monitors. Instead, refer to the following documents:
Subject Where to look How to configure Capsule Neuron DataCaptor System Administrators Guide How to operate Capsule Neuron Capsule Neuron Status Application Clinical Users Guide Capsule Neuron Mobile Vitals Plus Application Clinical Users Guide 24 Operating the Capsule Neuron [Chapter 3]
Maintaining the Capsule Neuron 4 Capsule recommends that you carry out regular maintenance activities as described in this guide to ensure correct operation of the device. E n g l i s h Periodic cleaning and disinfection Caution: When cleaning or disinfecting the Capsule Neuron, batteries, and cables, you must power off the device first. However, you can use standard computer screen solution to wipe down the Capsule Neuron touch screen (for example, to remove fingerprints) during normal operation, while it is powered on. Periodically clean and disinfect the elements in the Capsule Neuron, including cables and batteries, by wiping the outer case with a lint-free cloth, lightly moistened with warm water and a mild, non-abrasive cleaning solution containing any of the compatible cleaning agents below
(follow the manufacturers guidelines):
70% isopropyl alcohol CaviCide 10% bleach solution Clorox Disinfecting Wipes Clorox Healthcare Bleach Germicidal Cleaner Sani-Cloth, Sani-Cloth Plus, Super Sani-
Cloth, Sani-Cloth HB, Sani-Cloth Bleach Wipe ANIOSURF Premium, Bacteranios SF, SURFASAFE, WIPANIOS Cleaning Precautions Caution:
To avoid damage to the Capsule Neuron, try to limit contamination and minimize the need for disinfectants. Since the Capsule Neuron is not completely watertight:
- Do not spray cleaning liquid or foam on the Capsule Neuron, or submerge or soak it for cleaning.
- Never spray or squirt any type of liquid directly on the Capsule Neuron; spray the liquid, gel, or foam on a cloth and then use that cloth to rub on the device.
- Do not spill liquids on or around the unit.
- Do not expose the power cable or power brick to liquid.
- Make sure that the cover on the USB port is securely fastened. Do not use any other agent than those listed. (Contact Capsule for assistance if your cleaning agent is not on the list.) Do not use harsh solvents. Do not clean, disinfect, or sterilize any part of the system by autoclaving or with the use of ethylene Do not touch, press, or rub the display panel with abrasive cleaning compounds, instruments, oxide gas (gas sterilization). brushes or rough-surface materials. Installation and Maintenance Guide [Chapter 4]
25 Periodic maintenance of the Capsule Neuron Authorized Access Certain components on the Capsule Neuron are only accessible to Capsule technical support personnel. These elements are held in place using special screws referred to as hexalobular internal. h s i l g n E However, other components on the Capsule Neuron, such as the main battery, can be removed by biomed staff, for purposes of maintenance or cleaning, for example. These elements are held in place using Philips screws. Inspections Caution: Power off the Capsule Neuron before you inspect the power cable and power brick. Once per year, carry out an inspection of:
the power cable the power brick Look for any visible or other damage, overheating, or corrosion. A damaged power cable or power brick can affect the operation of the Capsule Neuron. Replace damaged components with new components. Storing the Capsule Neuron If the Capsule Neuron is not in use, make sure that you respect its storage conditions:
Temperature: -20C to +60C (-4F to +140F) Humidity: 0% to 95% RH non-condensing Atmospheric pressure: 500 hPa to 1060 hPa Maintenance of the Capsule Neuron batteries Cleaning When cleaning the Capsule Neuron batteries, apply the cleaning procedures and precautions described above under Periodic cleaning and disinfection. Short-term maintenance For daily usage purposes, it is recommended that you keep the batteries in charge mode; that is, keep the batteries installed in the Capsule Neuron, and keep the Capsule Neuron connected to the electrical mains. 26 Maintaining the Capsule Neuron [Chapter 4]
Long-term storage and maintenance Shelf life of the batteries Both the main and the extended batteries for Capsule Neuron have a shelf life of three months. This limit applies to batteries that are not in use (that is, if they are not either in the process of charging, or being used to supply power to the Capsule Neuron). If the battery fully discharges, during storage for example, then you must replace it. E n g l i s h Caution: Both the main battery and the extended battery have shelf lives of three months from the date of manufacture. You must install a newly received battery in a Capsule Neuron, and fully charge the battery within three months of receipt. Refer to the Capsule Neuron packaging for the battery expiration date. Storing the batteries If the Capsule Neuron is not in use for an extended period of time, we recommend that you:
1. Charge the battery completely. 2. Remove the fully charged battery from the Capsule Neuron (refer to Removing a battery on page 22). 3. To maximize the battery life span, make sure that you store the battery within the recommended parameters:
Temperature: -20C to +60C (-4F to +140F) Humidity: 0% to 95% RH non-condensing Atmospheric pressure: 500 hPa to 1060 hPa 4. Store the battery and the Capsule Neuron separately. Maintaining the Capsule Neuron [Chapter 4]
27 h s i l g n E 28 Maintaining the Capsule Neuron [Chapter 4]
Technical Information Guidance and manufacturers declaration 5 E n g l i s h Electromagnetic Effects The Capsule Neuron radiates and consumes radio frequency energy. It has been designed and evaluated to comply with the emission and immunity requirements of EN/IEC 60601-1-2, but electromagnetic interference may occur if not installed correctly and used in accordance with the instructions in this manual. Refer to the Tables in this chapter for detailed information regarding declaration and guidance related to emission, immunity, and separation distances. Caution:
Portable and mobile radio frequency devices, such as mobile phones, can impact the correct functioning of this device and should not be used in close proximity of this device. Use of accessories, power adapters and cables other than those specified may result in increased emission and/or decreased immunity of the Capsule Neuron. Electromagnetic Emissions The Capsule Neuron is intended for use in the electromagnetic environment specified below. The customer or the user of the Capsule Neuron should make sure that it is used in such an environment. Emissions test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 RF emissions CISPR 11 Harmonic emissions IEC 61000-3-2 Class A Class A Voltage fluctuations/
flicker emissions IEC 61000-3-3 Complies The Capsule Neuron uses RF energy only for its internal function; its RF emissions are therefore very low and are not likely to cause any interference to nearby electronic equipment Class A: The Capsule Neuron is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Note: UT is the AC mains voltage prior to application of the test level. Electromagnetic Immunity (ESD, EFT, Surge, Dips and Magnetic Field) The Capsule Neuron is intended for use in the electromagnetic environment specified below. The Installation and Maintenance Guide [Chapter 5]
29 customer or the user of the Capsule Neuron should ensure that it is used in such an environment. Immunity Test IEC 60601 test level Compliance level Electromagnetic environment -
Guidance h s i l g n E Electrostatic discharge (ESD) IEC 61000-4-2 6 kV contact 6 kV contact 8 kV air 8 kV air Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%. Electrical fast transient/burst IEC 61000-4-4 2 kV for power supply lines 1 kV for input/
output Lines Surge IEC 61000-4-5 1 kV line(s) to line(s) Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 2 kV line(s) to earth
<5% UT (>95% dip in UT) for 0.5 cycle 40% UT (60% dip in UT) for 5 cycles 70% UT (30% dip in UT) for 25 cycles
<5% UT (>95% dip in UT) for 5 sec 2 kV for power supply lines Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. Mains power quality should be that of a typical commercial or hospital environment. If the user of the Capsule Neuron requires continued operation during power mains interruptions, it is recommended that the Capsule Neuron be powered from an uninterruptible power supply. 1 kV for input/output Lines 1 kV line(s) to line(s) 2 kV line(s) to earth
>95% voltage dips in UT for 0.5 cycles 60% voltage dips in UT for 5 cycles 30% voltage dips in UT for 25 cycles
>95% voltage interruption in UT for 5 seconds Power frequency
(50/60 Hz) magnetic field IEC 61000-4-8 3 A/m 3 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical hospital environment. 30 Technical Information [Chapter 5]
Electromagnetic Immunity (RF Conducted and Radiated) The Capsule Neuron is intended for use in the electromagnetic environment specified in the table. The customer or the user of the Capsule Neuron should make sure that it is used in such an environment. Immunity Test IEC 60601 test level Compliance level Electromagnetic environment - Guidance E n g l i s h Conducted RF IEC 61000-4-6 3 V 3 Vrms 150 kHz to 80 MHz Portable and mobile RF communications equipment should be used no closer to any part of the Capsule Neuron, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance Radiated RF IEC 61000-4-3 3 V/m 80 MHz to 2.5 GHz 3 V/m 80 MHz to 800 MHz 800 MHz to 2.5 GHz Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters). Field strengths from fixed RF transmitters, as determined by an electromagnetic site surveya, should be less than the compliance level in each frequency rangeb. Interference may occur in the vicinity of equipment marked with this symbol:
Note: At 80 MHz and 800 MHz, the higher frequency range applies. Note: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be pre-
dicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF trans-
mitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Capsule Neuron is used exceeds the applicable RF compliance level above, the Capsule Neuron should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the Capsule Neuron 2. b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. Technical Information [Chapter 5]
31 Recommended Separation Distances Between Portable and Mobile RF Communications Equipment and the Capsule Neuron The Capsule Neuron is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Capsule Neuron can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Capsule Neuron as recommended below, according to the maximum output power of the communications equipment. h s i l g n E Rated maximum output power of transmitter (W) Separation distance in meters according to frequency of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz 0.01 0.1 1 10 100 0.12 0.37 1.17 3.70 11.70 0.12 0.37 1.17 3.70 11.70 0.23 0.74 2.33 7.37 23.30 Note: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. Note: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. 32 Technical Information [Chapter 5]
E n g l i s h Capsule Neuron technical specifications Dimensions Weight Mounting options Electrical ratings Capsule Neuron Part Number: DC-NU2-UMPC Width: 265 mm (10.4 inches) Height: 210 mm (8.3 inches) Depth: 45 mm (1.8 inches) 2.3 kg (3.5 kg with batteries) VESA 75/100 standard mounting bracket 20 V DC, 3.53 A External power supply 100-240 V AC, 1.22-0.68 A, 47-63 Hz, 60 W max Battery Main: Lithium-lon Battery Pack 3S1P 2600 mA Extended: Lithium-lon Battery Pack 3S2P 5200 mA Operation conditions Continuous Protection against ingress of water IPX2 EN60601-1 Classification No classification, no applied parts Display size 10.1 inch (25.6 centimeter), resistive touch screen, resolution 1024x600 Display brightness 375 cd/m Contrast Memory Storage 400:1 1 GB 16 GB SSD Network connectivity 10/100/1000 base-T LAN WLAN IEEE 802.11 a/b/g/n WLAN security Wireless range Cooling Operating environment Transport and storage environment WPA & WPA2 personal, WPA & WPA2 enterprise Encryption: TKIP, AES 10-20 meters, depending on Wi-Fi network configuration Passive cooling system (fanless) Temperature: 0C to +40C (+32F to +104F) Humidity: 10% to 95% RH non-condensing Atmospheric pressure: 700 hPa to 1060 hPa Temperature: -20C to +60C (-4F to +140F) Humidity: 0% to 95% RH non-condensing Atmospheric pressure: 500 hPa to 1060 hPa Technical Information [Chapter 5]
33 Device Identification Module (DIM) technical specifications DIMs do not require an external power supply and use standard DB9 and RJ45 connections. The Device ID Module is a medical grade product compliant with IEC 60601-1 requirements. h s i l g n E Features Device ID Module P/N B1-DIM-CT-01 Provides Automatic Device Identification DB9 Serial Port Input RJ45 Serial Port Output Powered from the Capsule Neuron, Terminal Server, or DTS and RTS lines Dimensions Power requirements Temperature Relative humidity Atmospheric pressure Certifications Length: 69 mm (2.7 inches) Width: 38 mm (1.5 inches) Height: 22 mm (0.9 inches) Weight: 50 grams (1.76 ounces)
+/- 6V output voltage 3 to 8 milliamp power consumption Operating: 0 C - 55 C (32 F to 130 F) Storage: -30 C to +85 C (-22 F to +185 F) Operating: 0 to 99% non-condensing Storage: 0 to 99% non-condensing Operating: 700 hPa to 1060 hPa Storage: 500 hPa to 1060 hPa EN60601-1, EN60601-1-2 CE Marking, RoHS-compliant 34 Technical Information [Chapter 5]
Regulatory Information Explanation of Device and Packaging Symbols Symbol Description Read the operating instructions before using the medical device. E n g l i s h Lot number Quantity Product part number Product serial number Product revision Gross weight Net weight Temperature limitation for transport and storage Air pressure limitation for transport and storage Shelf-life of Capsule Neurons battery (with date three months after manufacture) 2017-06 Manufactured date Manufactured for Do not use if package is damaged Technical Information [Chapter 5]
35 Symbol Description Fire hazard h s i l g n E Relative humidity (non-condensing) for transport and storage Ethernet MAC address Ethernet Wi-Fi MAC address Caution: consult accompanying documents before using Power symbol Non-ionizing radiation Compliance with FCC Regulations Compliance with European directives Rx Only Caution: United States Federal Law restricts this device to sale by or on the order of a physician or licensed practitioner Separate collection for electrical and electronic waste (WEEE directive and Battery directive) Direct current (DC) USB connection Serial connection 36 Technical Information [Chapter 5]
E n g l i s h Symbol Description Address of the legal representative for the European market Safety and Regulatory Compliance EN/IEC Capsule Neuron complies with EN/IEC 60601-1 and EN/IEC 60601-1-2. Data Integrity: Capsule Neuron does not compromise the data coming from the medical device. This does not include data not being delivered or delays in data delivery. Medical Device Integrity: Capsule Neuron does not compromise the operation of the connected medical devices. Federal Communications Commission Capsule Neuron complies with Part 15 of the FCC Rules. Operation is subject to two conditions:
This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Note: For operation within 5.15 ~ 5.25GHz / 5.47 ~5.725GHz frequency range, Capsule Neuron 2 is restricted to indoor environment. The band from 5600-5650 MHz will be disabled by the software during the manufacturing and cannot be changed by the end user. This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules. Caution: Capsule is not responsible for any radio or television interference caused by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the users authority to operate the equipment. FCC Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Technical Information [Chapter 5]
37 Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. Note: The country code selection is for non-US model only and is not available on all US models. Per FCC regulation, all Wi-Fi products marketed in the USA must fixed to US-operation channels only. h s i l g n E Declaration CE The Capsule Neuron are class I devices that comply with the requirement of the Council Directive 93/42/EEC of June 14, 1993 concerning medical devices and carry CE-marking accordingly. The Capsule Neuron complies with the requirement of the Council Directive 1999/5/EC of March 9, 1999 concerning radio equipment and telecommunications terminal equipment and carry CE-
marking accordingly. The DataCaptor ID Module (DIM) complies with the requirement of the Council Directives 2006/95/
EC of December 12, 2006 concerning electrical equipment designed for use within certain voltage limits and 2004/108/EC of December 15, 2004 concerning electromagnetic compatibility. Batteries in the Capsule Neuron are not based on mercury, lead or cadmium technologies. The batteries used in this product are in compliance with the Council Directive 2006/66/EC. Chromium, lead, mercury, or cadmium are not intentionally added to packaging materials and are not present in a cumulative concentration greater that 100 ppm as incidental impurities. No halogenated plastics or polymers are used for packaging material. Packaging is compliant with the Council Directive 94/62/EC. RoHS and WEEE Compliance The Capsule Neuron, and DIM do NOT contain any of the following substances (in concentrations exceeding legal threshold limits):
Lead Mercury Cadmium Hexavalent Chromium Polybrominated Biphenyls (PBB) Polybrominated Diphenyl Ethers (PBDE) In the European Union, Capsule Neuron, DIM and cables should be collected separately and not disposed of with household waste. Refer to the next section on Recycling and the Environment for more details. Recycling and the Environment Improper disposal of IT equipment can have a negative impact on health and the environment. The Capsule Neuron, DIM and serial cables should be deposited at an appropriate facility to enable recovery and recycling. Packaging and manuals can also be recycled according to your local recycling 38 Technical Information [Chapter 5]
scheme. E n g l i s h Technical Information [Chapter 5]
39
1 2 3 | Attestation (DFS Client Declaration) | Attestation Statements | 567.05 KiB | May 12 2013 |
capsul>
defining connectivity at the point-of-care DFS client device channel plan and software operational declaration Date: 2013-11-25 We, Capsule Technologie SAS, declare that the device, FCC ID: 2AA69001 Model Name: Capsule Neuron 2, does not have Ad Hoc on non-US frequencies and/or on DFS frequencies. Also, the client software and associated drivers will not initiate any transmission on DFS frequencies without initiation by a master. This includes restriction on transmissions for beacons and support for ad-hoc peer-to-peer modes. Below is the channel / frequency plan for the device 5180 : 5190 : 5200 : 5210 : 5220 : 5240 : 5260 : 5270 Capsule Technologie www.capsuletech.com S.A.S. au capital de 1 376 616 Euros 9B Villa Pierre Ginier Copyright 2013 R.CS. Paris B 412 015 299 APE 6201 Z Tl, : +33 153 34 14 00. Fax : +33 153 3414.09 N de TVA intracommunautaire : FR32412015299 capsul>
defining connectivity at the point-of-care Also, on DFS channels, the WLAN driver in the device operates under the control of an AP at all times, except when in ad-hoc mode, on US non-DFS channels. The device passively scans DFS frequencies until a master device is detected. The control of this functionality is not accessible to anyone under any conditions. Furthermore, the firmware is protected by special signature and CRC checksum. Signature and CRC checksum will be calculated and verified before firmware upgrade. Unauthorized modification to firmware will lead the failure of verification thus firmware upgrade is not allowed. Technologie villa Pierre Ginier F-75618 PARIS Sincerely yours, 14 00 Stephane Mazet Capsule Technologie SAS Tel: 01.84.17.12.89 Fax: 01.53.34.14.09 E-mail : stephanem @capsuletech.com Capsule Technologie www.capsuletech.com S.A.S. au capital de 1 376 616 Euros OB Villa Pierre Ginier Copyright 2013 R.C.S. Paris B 412 015 299 75018. Paris, France APE 6201 Z Tl. : +33 15334 14 00. Fax : +33 153 341409 N de TVA intracommunautaire : FR32412015299
1 2 3 | Confidentiality Request (Shortterm) | Cover Letter(s) | 175.46 KiB | May 12 2013 |
capsul>
defining connectivity at the point-of-care Date: 2013-11-25 FCC ID: 2AA69001 To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to DA 04-1705 of the commissions public notice, we request short-term confidential treatment for the following information until 2014/02/22 in order to ensure sensitive business information remains confidential until the actual marketing of the device:
External photos Test Setup photos Users manual Internal Photos Capsule Technologie ila Pierre Gini RIS Sincerely yours, 53 34 14 00 3153341409 Stephane Mazet Capsule Technologie SAS Tel: 01.84.17.12.89 Fax: 01.53.34.14.09 E-mail : stephanem @capsuletech.com Capsule Technologie www.capsuletech.com S.A.S. au capital de 1 376 616 Euros OB Villa Pierre Ginier Copyright 2013 R.C.S. Paris B 412 015 299 75018. Paris, Franc APE 6201 Z Tl. : +33 153 34 14 00. Fax : +33 153 34.14.09 N de TVA intracommunautaire ; FR32412015299
1 2 3 | Confidentiality Request | Cover Letter(s) | 240.11 KiB | May 12 2013 |
capsul defining connectivity at the point-of-care FCC ID: 2AA69001 Date: 11/25/2013 To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commissions Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below:
Schematics Block Diagram The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this ap mseure DFechnologie 9, villa Piers Ginier 4 Sincerely yours,
& PARIS 34 14 00 34 14 09 Stephane Mazet Capsule Technologie SAS Tel: 01.84.17.12.89 Fax: 01.53.34,14.09 E-mail : stephanem@capsuletech.com www.capsuletech.com S.A.S. au capital de 1 376 616 Euros Copyright 2013 R.CS. Paris B 412.015 299 T5018. Pi ari APE 6201 Z Tl. : +33 153 34 14.00. Fax : +33 1 53 341409 N de TVA intracommunautaire : FR32412015299
1 2 3 | Cover Letter (Agent Authorization) | Cover Letter(s) | 200.49 KiB | May 12 2013 |
capsul>
ring conmmectivity at the paint of care Power of Attorne To whom it may concern:
Date: December 3, 2013 We, the undersigned Capsule Technologie SAS hereby authorize Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch (BV CPS Taoyuan) of Taiwan to act on our behalf in all matters relating to all processes required in FCC Part 15C/15E and any communication needed with the national authority. Any and all acts carried out by BV CPS Taoyuan on our behalf shall have the same effects as acts of our own. PCC ID DC-Nu2-uMPC___2AA69001 If you have any questions regarding the authorization, please dont hesitate to contact us. Thank you!
Sincerely yours, Stephane Mazet Capsule Technologie SAS Tel: 01.84.17.12.89 Fax: 01.53.34.14.09 E-mail : stephanem @capsuletech.com
1 2 3 | Operational Description | Operational Description | 12.05 KiB | May 12 2013 |
FCC ID: 2AA69001 Operational Description This device is an IPC with built-in a WLAN IEEE802.11a/b/g/n module and RFID module. For WLAN IEEE802.11a/b/g/n card:
The device is including a WLAN module. The WLAN module is power by host equipment
(IPC). The type of the antenna is PCB antenna. Under normal use condition, the user has to keep at least 20cm separation distance between radiator and the body of the user. The WLAN card is operates in both of the 5GHz (OFDM technique) and 2.4GHz (DSSS and OFDM technique) bands. The EUT operates in the 2.4GHz frequency spectrum with throughput of up to 300Mbps. The EUT incorporates a MIMO function. Physically, the card provides two completed transmitters and two receivers. For the 802.11n, the EUT is 2 * 2 spatial MIMO (2Tx &
2Rx) without beam forming function. When the EUT operating in 802.11b, 802.11g, 802.11a, the software operation, which is defined by manufacturer, only set single Tx. The EUT complies with draft 802.11n standards and backwards compatible with 802.11b, 802.11g, 802.11a products. FCC 15.407(c) states: The device shall automatically discontinue transmission in case of either absence of information to transmit or operational failure. These provisions are not intended to preclude the transmission of control or signaling information or the use of repetitive codes used by certain digital technologies to complete frame or burst intervals. Applicants shall include in their application for equipment authorization a description of hoe this requirement is met. Data transmission is always initiated by software, which is then pass down through the MAC, through the digital and analog baseband, and finally to the RF chip. Several special packets (ACKs, CTS, PSPoll, etc) are initiated by the MAC. There are the only ways the digital baseband portion will turn on the RF transmitter, which it then turns off at the end of the packet. Therefore, the transmitter will be on only while one of the aforementioned packets are being transmitted. Report No.: RF130923D14/-1/-2/-3 FCC ID: 2AA69001 For RFID Module:
The transmitter of the EUT (IPC) is powered by 3.3Vdc from host equipment. The type of antenna is PCB antenna. The output power of this device is very low. Under normal use condition, the transmitter and the receiver are quite close, so high EIRP power is neither necessary nor allowed because of interference. Report No.: RF130923D14/-1/-2/-3
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2013-12-05 | 5745 ~ 5825 | DTS - Digital Transmission System | Original Equipment |
2 | 5660 ~ 5700 | NII - Unlicensed National Information Infrastructure TX | ||
3 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 3 | Effective |
2013-12-05
|
||||
1 2 3 | Applicant's complete, legal business name |
Capsule Technologie S.A.S.
|
||||
1 2 3 | FCC Registration Number (FRN) |
0023173099
|
||||
1 2 3 | Physical Address |
76-78 Avenue de France
|
||||
1 2 3 |
Paris
|
|||||
1 2 3 |
Paris, N/A
|
|||||
1 2 3 |
France
|
|||||
app s | TCB Information | |||||
1 2 3 | TCB Application Email Address |
c******@curtis-straus.com
|
||||
1 2 3 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
1 2 3 |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
|||||
app s | FCC ID | |||||
1 2 3 | Grantee Code |
2AA69
|
||||
1 2 3 | Equipment Product Code |
001
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 3 | Name |
S**** M********
|
||||
1 2 3 | Title |
Engineer
|
||||
1 2 3 | Telephone Number |
01841********
|
||||
1 2 3 | Fax Number |
01533********
|
||||
1 2 3 |
s******@capsuletech.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 3 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 3 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 3 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 02/22/2014 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 3 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 3 | Equipment Class | DTS - Digital Transmission System | ||||
1 2 3 | NII - Unlicensed National Information Infrastructure TX | |||||
1 2 3 | DXX - Part 15 Low Power Communication Device Transmitter | |||||
1 2 3 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Neuron 2 | ||||
1 2 3 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 3 | Modular Equipment Type | Does not apply | ||||
1 2 3 | Purpose / Application is for | Original Equipment | ||||
1 2 3 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 3 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 3 | Grant Comments | Power listed is the maximum combined conducted output power. End users and installers must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. | ||||
1 2 3 | Power listed is the maximum combined conducted output power. End users and installers must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product guidelines. Operations in the 5.15GHz - 5.25GHz band are restricted to indoor usage only. This device complies with the Dynamic Frequency Selection (DFS) requirements of Report and Order FCC 03-287 as a Client only without Radar Detection. | |||||
1 2 3 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 3 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 3 | Firm Name |
Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch
|
||||
1 2 3 | Name |
R**** C******
|
||||
1 2 3 | Telephone Number |
+886-******** Extension:
|
||||
1 2 3 | Fax Number |
+886-********
|
||||
1 2 3 |
r******@tw.bureauveritas.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC MO | 2412 | 2462 | 0.14 | |||||||||||||||||||||||||||||||||||
1 | 2 | 15C | CC MO | 5745 | 5825 | 0.126 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15E | CC MO | 5180 | 5240 | 0.039 | |||||||||||||||||||||||||||||||||||
2 | 2 | 15E | CC MO ND | 5260 | 5320 | 0.038 | |||||||||||||||||||||||||||||||||||
2 | 3 | 15E | CC MO ND | 5500 | 5580 | 0.036 | |||||||||||||||||||||||||||||||||||
2 | 4 | 15E | CC MO ND | 5660 | 5700 | 0.034 | |||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
3 | 1 | 15C | CC | 13.56000000 | 13.56000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC