ATTACHMENT F.
- USERS MANUAL
CASTON
CRANE SCALE OO WW NN EE RR '' SS MM AA NN UU AA LL 2 Federal Communications Commission Requirements Warning : Changes or modifications not expressly approved by the party responsible for compliance with the FCCS rules could void the user's authority to operate the equipment. THIS DEVICE COMPLIES WITH PARTS 15 OF FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS
(1)THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. 3 CONTENTS 1. INTRODUCTION ......................................................................5 2. PRECAUTION ...........................................................................5 3. OVERALL VIEW.......................................................................6 4. SPECIFICATIONS.....................................................................6 5. DISPLY & KEY FUNCTIONS...................................................7 6. FUNCTION OF REMOTE CONTROL.....................................8 7. BATTERY USAGE.....................................................................9 8. USE OF BATTERY CHARGER ..............................................10 9. FUNCTIONS & DESCRIPTIONS ...........................................11 10. SET MODE.............................................................................12 11. TEST MODE ..........................................................................13 12. OPTIONS................................................................................14 13. PRODUCT SIZE.....................................................................15 14. ERROR MESSAGE................................................................16 4 1. INTRODUCTION We greatly appreciate your purchase of the CASTON-. These goods perform excellently and exhibit splendid properties through strike tests. The CASTON- is delicately designed to coincide with the special requirements of several industrial fields and includes many functions and various external interfaces. Also, it is programmed for the user's convenience and contains display functions that are easily accessible. Before using The CASTON-, it is recommended that you read this manual carefully so you may use this device to its full potential. 2. PRECAUTION When the CASTON- is installed, safety pin in hook should be fixed to prevent dropping out from lift eye bolt. Check the scale's stability. Do not press the keys with excessive force, the keys are to be pressed with a soft touch. Do not use ignitable material for cleaning. Keep the CASTON- away from the rain. Avoid sudden temperature change. The operating temperature range is 10 to 40 . Do not install CASTON- in a place with high voltage and excessive electrical noises. Keep it in dry place. Do not use under direct rays or in a dusty place. Do not use in an area with excessive electrical noises and vibration. Do not stand under the scale while weighing the load, and you should be careful to provide against a safety accident. If you don't use the scale for a long time, you should turn off POWER S/W on the rare panel. The load which hang on the hook should be a vertical load. (Refer to the next features.) LO AD LO AD 5 3. OVERALL VIEW 4. SPECIFICATIONS MAX. TARE WEIGHT FULL TARE DISPLAY TEMPERATURE RANGE POWER SOURCE POWER CONSUMPTION L.E.D.(1.5 inch) 10 < 40 6V 1.2W DISPLAY LAMP ZERO, TARE, HOLD, LOW BATTERY LAMP 6 5. DISPLAY & KEY FUNCTIONS DISPLAY
- WEIGHT DISPLAY : Displays weight or messages.
- ZERO LAMP : Indicates that scale is stable and at zero.
- TARE LAMP : Indicates that scale is currently using a tare.
- HOLD LAMP : Indicates that the HOLD feature has been activated.
- LOW BATTERY LAMP : Indicates that battery is low and must be changed soon. KEY FUNCTIONS key 6. FUNCTION OF REMOTE CONTROL ON Used to turn ON. Function OFF Used to turn OFF. ZERO Used to set the zero point to 0 . TARE Used to enter tare weight and to clear tare entries. HOLD Used to weigh unstable things. (Liquids, Livestock, etc.) 7
(1) Remote Control Operation RED LAMP : Blinks when keys are pressed. ON/OFF KEY: Same as ON/OFF key of Scale. ZERO KEY : Same as ZERO key of Scale. TARE KEY : Same as TARE key of Scale. HOLD KEY : Same as HOLD key of Scale. SET(Clear) KEY : Used to clear previously added weights. SUM KEY : Used to add weights. If you press SUM key, it will be showed the accumulated value, and then it will moved to WEIGHING MODE a few seconds later.
(2) Remote Control Specification Available Distance Available Angle Power 6 m < 10 m 60 3V (1.5V AMM 2) 8 7. BATTERY USAGE Open the battery lid located in back of the scale and turn main power switch off. Separate the battery connector and take out the discharged battery. Put a charged battery in rear and connect the battery connector. Turn main power switch on and cover the battery lid. Check the voltage of 8. USE OF BATTERY CHARGER battery charger before use.
(It is fixed to 220V before shipping) Insert charger A.C cord into the power source and connect the discharged battery to the connector. Turn ON the switch on the battery charger, charging will start. You can check charging condition with red L.E.D in charger. Estimated time for charging is 8 hours.
(Charging time can be varying according to the battery condition.) 9 9. FUNCTIONS & DESCRIPTIONS Turn the power switch before using the scale. Power switch is located on the rear panel.
(1) ON/OFF KEY Press the ON/OFF key then The scale will perform self-test on Weight Display and will be ready to weigh when ZERO lamp turns on.
(2) ZERO FUNCTION Used to remove small variations in the scale's zero.
(You can adjust the zero up to 2% or 10% of the maximum capacity) If the weight is not zero though there is nothing on the hook, you can press ZERO key to go to zero state.
(3) TARE FUNCTION Tare is the weight of container being used for a commodity. The TARE key subtracts the weight of the container. After hanging a container on the hook, press the TARE key. Then the scale will memorize the weight of the tare, and will display 0 kg with turning on the TARE lamp. If you weigh items, you will see the net weight. To release this function, remove everything from the hook and press the TARE key. Then the TARE LAMP will turn off and this function is terminated.
; The weight including TARE weight can't exceed the maximum capacity.
(4) HOLD FUNCTION Automatic Hold Function (This function is performed whenever you weigh an item) Press the HOLD key when the hook is empty (in zero value condition) The Weight Display will display "AH on" sequentially. The scale will change from the Normal mode to Auto-hold mode, and HOLD lamp will turn on. If you weigh unstable things in Auto-hold mode, "HoLd" will display on the Weight Display. And then, the average value of the weight fluctuation will display. If the weight fluctuation range exceeds within 10% of weight, the scale will retry Auto-hold function. To escape from Auto-hold mode, press the HOLD key. It will be returned to the Normal mode and "AHoFF" will be displayed with HOLD lamp turning off. 10 Manual Hold Function (Execute when you press HOLD key) Press the HOLD key while weighing an unstable item.
"HoLd" will display and then, the average value of the weight fluctuation will display on the Weight Display. To escape from this mode, empty the hook or press HOLD key. Then the scale changes from Hold mode to Normal mode. 10. SET MODE
(1) How to enter Press the ON/OFF key while pressing the TARE key, and SET mode starts.
(2) Key Usage ZERO : Returns the display to 0. TARE : Increase the set value to 1. SET : Store and move into next menu.
(3) Set Menu(F1 - F5) F1 : Digital Filter Setting Set Value F1- 1 F1- 4 F1- 9 In high speed (Less vibration) In normal speed Very slowly (Much vibration) Description F2 : Automatic zero tracking compensation Set Value F2- 0 F2- 4 F2- 9 Description No compensation Compensation for gradual change below 2 divisions. Compensation for gradual change below 4.5 divisions. F3 : Weight backup (Power on actual weight) Set Value F3- 0 F3- 1 Weight backup is OFF Weight backup is ON Description NOTE. If you press SET key after F3 setting, it will display "bye" and enter to Normal mode. F4 : Zero key operation range set Set Value F4- 0 F4- 1 2% : Zero key operation within 2% of maximum weight. 10% : Zero key operation within 10% of maximum weight. Description F5 : Option select 11 Set Value F5- 0 F5- 1 TW-150 TW-100 11. TEST MODE Description
(1) How to enter Press the ON/OFF key while pressing the ZERO key and TEST mode starts.
(2) Key Usage SET : Move to the next menu. ZERO, TARE, HOLD : Perform the test.
(3) Test Menu (TEST 1 - TEST 3) TEST 1 : Display test Display Description 8.8.8.8.8. TEST 1 is performed. After display test completing, it will be moved to test 2 automatically. TEST 2 : Key & Remote control test ZERO TARE HOLD Key Code Description 1 2 3 Press the key to be tested and the code of the key is displayed. Press the key to be test and the No of key mode should be identify with code of key. If you press SET key, it will be moved to test 3. TEST 3 : A/D converter test (Load cell test) Display Description Digital value of current weight Ex) 5500 Display digital value of current weight. This value means converted digital value. If you press SET key after test 3 completing, it will enter to Normal mode. Check whether digital value changes. If the digital value is fixed or zero is displayed, Please request A/S to head office. 12 12. OPTIONS It is connected with CASTON(crane scale) by use of wireless communication.
(1) Option 1 : TW-100 Fig.1 TW-100 Fig.2 Charger Frequency Channel interval Channel Generating power 903.000Mhz < 918.500Mhz 500Khz 32 channel Max. 10mW Communication method FSK (Frequency Shift Keying fsk) Comm. speed Comm. distance Display Size of letter 9600bps Max. 100M LCD (5 digit) 12 mm (Height) Display below zero
- displayed Battery life time Approx. 10 hours Battery charging time Approx. 4 hours Power Power consumption Temperature range Function Product size(mm) TW-100 : Rechargeable DC Battery 7.2V 720mA Charger : AC220V/60Hz 0.5 W
-10 <+40 PC interface, zero, tare, gross, net, hold, print, clock, id setting, key tare setting, weight sum, peak hold. 62(W)28(D)147(H) 13 13. PRODUCT SIZE
(1) 10TON50TON
(UNIT : mm) MODEL 1THD 2THD 3THD 5THD CAPACITY 1000 0.5 2000 1 3000 2 5000 2 PRODUCT WEIGHT 26 28 31 31 14
(2) 10TON50TON
(UNIT : mm) MODEL CAPACITY A B C 10THD 15THD 20THD 30THD 50THD 10000 5 15000 10 20000 10 30000 20 50000 20 D 845 886 990 667 682 725 895 220 220 220 220 83 99 126 138 1200 1400 220 180 1520 15 E 57.2 63.5 86 108 106 F 42 50 60 92 112.7 PRODUCT WEIGHT 44 53 76 220 390 14. ERROR MESSAGE CH 01 Reason Internal RAM is erased. Please request A/S to head office. Trouble-shooting CH 02 Reason Load cell connection failure or error in A/D conversion part. Please request A/S to head office. Trouble-shooting CH 03 Reason The Zero range exceed from 10% of Max. Check that there is nothing on the hook. Trouble-shooting Over Reason The display weight is larger than the Maximum capacity you've set. Don't load the article whose weight is larger than the Max. Capacity on the platform. This may damage Load Cell. Trouble-shooting 16